Search NASA⌕ Search

SEARCH · Search NASA

Results for “substeps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Optimization of COMPASS-U Support Structure

The global support structure for Compass Upgrade (COMPASS-U) employs many bolted and pinned components to improve the manufacturability of the whole structures. This is a departure from other designs used for highly loaded tokamaks, like Alcator C-Mod which used large forgings. Modeling of the numerous connections and interfaces was a challenge. This article will describe how to optimize the C-frame support structure with the goal to eliminate differential displacements at those interfaces and, importantly, minimize toroidal mutual displacement at the sliding joint of the toroidal field (TF) coils. The global support structure consists of 16 C-frames, and it can be simplified as a 1/8th cyclic symmetry model due to the eight vertical rods mounting that connect bottom CS and PF1-3 assemblies to the C-frames. Structure variants with different connection webs between two neighboring C-frames have been analyzed. The preloading of bolts can be split into several preload substeps to simulate the real assembly process of the COMPASS-U support structure. Additionally, the TF crown and the wedge plate can be further improved to become a solid part to better hold the TF coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Procedure Parsing: A Method for Parsing Handwritten Documents into Computer-Based Procedures

The nuclear industry is heavily procedure driven, where almost everything has a step-by-step instruction that is expected to be followed in detail. Historically, these procedures were printed on paper copies. Recently, the industry transitioned towards electronic copies (i.e., PDFs on tablets). One major drive for this transition is the introduction of human error and loss of situation awareness when using paper copies. However, electronic copies of documents inherently have the same error traps as their paper cousins. Therefore, there is an increased interest in a way to utilize the information in the step-by-step guidance, but to present it in a dynamic manner that guides the user and adapts to any encountered conditions. Researchers at Idaho National Laboratory propose a flexible, automated method based on document parsing and augmented by natural language processing (NLP) techniques, to address these shortcomings and capitalize on these recent advancements in machine learning. The proposed method provides a cost-effective solution for computer-assisted procedure parsing of hand-written control room procedures, originally authored in Word or PDF formats, into instructions that can be displayed as computer-based procedures (CBP) in a modern graphical user interface. The researchers devised, implemented and demonstrated the Operating Procedure Extender for Novel Systems (OPENS) method in 2020. The key to OPENS is to map the original procedure text into a context-free grammar, tying content to equipment, locations, and other steps, actions, etc. This formal grammar is then used to isolate and define keywords and actions verbs, such as “measure” or “evaluate” and tie them to specific equipment referenced within that step or located in other steps, substeps, actions, subactions and tables throughout the procedure. OPENS generates an abstract syntax tree from the document which it uses to store a copy of this information in the open-standard, machine-readable and human-readable file formats XML and JSON. The XML is useful to preserve the relational aspects of the procedure for referencing tables and branching information so the user can be directed to the next appropriate active step based on the values entered for that step and previous steps. The JSON is useful for storing and exchanging data objects used to track responses to previous steps and state changes in simulated environments. In future iterations, these formats can also be used for storing more detailed information about input during plant operation or simulation. The techniques the researcher developed could further be improved by integration of recent advancements in machine learning. NLP methods could standardize documents, correct for grammatical error, and provide automated semantic validation. The researcher expects that self-supervised techniques applied to collections of natural language instructions could strengthen the model with broader context. All these methods together give us a practical way to automatically extract protocols from documents and user interactions, empowering researchers, procedure writers and nuclear operators while moving the industry forward.

99 GENERAL AND MISCELLANEOUS↗

Investigation of CCD-digicon detector system characteristics

The reported investigation was undertaken with the aim to develop state-of-the-art detector technology for use in astronomical observations. Basic properties of the Digicon concept are to be extended to the two-dimensional capabilities of CCDs. The basic CCD-Digicon tube configuration utilizes a thinned, backside-illuminated CCD in place of the linear, discrete diode array at the back end of a windowed space telescope (ST) design Digicon tube. It is pointed out that the detector system built around the considered device promises to exhibit high photometric accuracy in combination with large numbers of uniform independent resolution elements. Potential applications include space astronomy missions with capability for observations extending into the extreme ultraviolet spectral region. Attention is given to continuing investigations into the characteristics of CCD response to backside photoelectron bombardment, taking into account the development of charge pulse centroiding readout techniques in combination with magnetic deflection substepping.

Hier, R. G.↗

The benefits of bottom-up design

An inconsistency is examined in generic top-down design methods and standards employed in the implementation of reliable software. Many design approaches adopt top-down ordering when defining the structure, interfaces, and processing of a system. However, strict adherence to a top-down sequencing does not permit accurate description of a system's error handling functions. The design of the system response to errors is becoming critical as the reliability requirements of systems increase. How top-down methods such as object oriented design and structured design do not adequately address the issues of error handling is described, and it is suggested using a bottom-up substep within these methods to eliminate the problem.

Mcfarland, Gregory↗

Resolution and noise properties of the Goddard High-Resolution Spectrograph

The Goddard High-Resolution Spectrograph (GHRS) observation characteristics and data analysis procedures, including deconvolution, are discussed. Particular attention is given to the detection of weak absorption lines in low-signal-to-noise observations. It is found that observations with the GHRS large aperture provide greater sensitivity for the detection of weak, isolated spectral features than does the small aperture for equal observing times. The noise characteristics are well represented by a Poisson distribution at low signal-to-noise characteristics. It is proposed that GHRS observations should be routinely structured with the use of comb-addition, quarter-substepping, FP-SPLITS, and multiple repeats to enable the proper discrimination against noise events capable of mimicking spectral features.

Gilliland, Ronald L.↗

Properties of the highly ionized disk and halo gas toward two distant high-latitude stars

Goddard High Resolution Spectrograph (GHRS) intermediate -resolution observations of S III, Si III, Al III, Si IV, C IV, and N V absorption along the sight lines to HD 18100 (l = 217.9 deg, b = -62.7, d = 3.1 kpc, z = -2.8 kpc) and HD 100340 (l = 258.9 deg, b = +61.2 deg, d = 5.3 kpc, z = 4.6 kpc) are presented. These small science aperture spectra have resolutions ranging from 11 to 20 km/s full width at half maximum (FWHM) and S/N from 30 to 65 per diode substep. Strong absorption by moderately and highly ionized gas is seen in each direction. The absorption in the direction of the south Galactic polar region (HD 18100) is kinematically simple, while the absorption in the direction of north Galactic polar region (HD 100304) is kinematically complex. In each case the absorption by the highly ionized gas lies within the velocity range of absorption by neutral and weakly ionized gas. Along each sight line, the velocity dispersion determined from the unsaturated absorption lines increases with the energy required to create each ion. The logarithmic column densities for Al III, Si IV, C IV, and N V are log N(atoms/sq cm = 12.71, 13.10, 13.58, and 12.75 toward HD 18100 and log N = 12.88, 13.31, 13.83, and 13.04 toward HD 100340. Average ionic ratios among these species are very similar along the two sight lines. Differences in profile shape between the absorption for AL II, Si IV, C IV, and N V provide additional support for the claim of Savage, Sembach, & Cardelli (1994) that there exists two types of highly ionized gas in the interstellar medium. One type of highly ionized gas is responsible for the structured Si IV absorption and part of the C IV absorption. In this gas N(C IV)/N(Si IV) approximately 3.0 and N(C IV)/N(N V) greater than 6. The absorption by this gas seems to be associated with some type of self-regulating interface or mixing layer between the warm and hot interstellar medium. The other type of highly ionized gas is responsible for most of the N V absorption, part of the C IV absorption, and has very little associated Si IV absorption. In this gas N(C IV)/N(N V) is approximately 1 to 3. This gas is hot (T greater than 2 x 10(exp 5) K) and may be tracing the cooling gas of supernova (SN) bubbles or a Galactic fountain. The relative mixture of these two types of highly ionized gas varies from one sight line to the next. The two sight lines in this study sample halo gas in the solar neighborhood and have a smaller percentage of the more highly ionized gas than inner Galaxy sight lines.

Savage, Blair D.↗

Computerized procedures system

An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

Lipner, Melvin H↗