Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗

Optimization of Asynchronous Communication Operations through Eager Notifications

UPC++ is a C++ library implementing the Asynchronous Partitioned Global Address Space (APGAS) model. We propose an enhancement to the completion mechanisms of UPC++ used to synchronize communication operations that is designed to reduce overhead for on-node operations. Our enhancement permits eager delivery of completion notification in cases where the data transfer semantics of an operation happen to complete synchronously, for example due to the use of shared-memory bypass. This semantic relaxation allows removing significant overhead from the critical path of the implementation in such cases. We evaluate our results on three different representative systems using a combination of microbenchmarks and five variations of the the HPCChallenge RandomAccess benchmark implemented in UPC++ and run on a single node to accentuate the impact of locality. We find that in RMA versions of the benchmark written in a straightforward manner (without manually optimizing for locality), the new eager notification mode can provide up to a 25% speedup when synchronizing with promises and up to a 13.5x speedup when synchronizing with conjoined futures. We also evaluate our results using a graph matching application written with UPC++ RMA communication, where we measure overall speedups of as much as 11% in single-node runs of the unmodified application code, due to our transparent enhancements.

Kamil, Amir↗

Investigation on Tuning Power–Frequency Droop for Improved Grid–Forming Inverter and Synchronous Generator Transient Load Sharing

Poor transient load sharing has been observed during the parallel operation of synchronous generators (SGs) and droop-controlled grid-forming (GFM) inverter-based resources (IBRs) in islanded microgrids. This can result in overcurrent protections, causing the inverters to trip, which leads to the collapse of voltage and frequency. In this article, small-signal analysis supported by electromagnetic transients (EMTs) simulation is performed on a detailed model of a microgrid containing IBRs and an SG to identify underdamped modes and their sensitivities to the power–frequency (P-F) droop parameter. Further EMT simulation of a more complex microgrid model with multiple GFM IBRs and SGs is performed to determine whether trends identified from the modal analysis extend to cases where the number of SGs in operation may vary. The objective is to investigate the effectiveness of tuning this parameter to reduce the likelihood of overcurrents in response to load and generation disturbances. The work uncovers both fast and slow modes of concern. Primarily, the findings show that increasing the P-F droop value improves the damping of the slower mode while degrading the damping of the faster mode, leading to an upper limit on the damping improvement of the GFM IBR output current. In EMT simulations of the more complex microgrid, the greatest damping improvement still exhibits significant maximum overshoot. Furthermore, the optimal value of the P-F droop parameter is sensitive to the number of SGs in operation. The conclusion is that tuning the P-F droop parameter is not an effective means to avoid the overcurrent tripping of GFM IBRs during response to large load or generation disturbances when operating in parallel to SGs in islanded microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

control↗

Four-phase interleaved TCM DC-DC buck converter with matrix inductor in battery charging application

In this paper, a 1-kW DC-DC buck converter with a four-phase interleaved matrix inductor is proposed for battery charging applications. It is well-known that the DC bias on the inductor will cause high core loss as it changes the B–H characteristic. Typically, the transient conduction mode employed in high voltage applications for zero-voltageswitching of devices would cause higher inductor current ripple. The conventional approach to reduce the effect of DC bias and inductor current ripple is employing multi-phases. However, the cost and size of the converter will increase significantly. This paper proposes the matrix inductor which has a small volume and reduces the effect of the DC bias by flux sharing and flux cancellation at the same time, results in low inductor core loss. With the interleaved operations the output current ripple can be lower which is suitable for battery charging application. Besides, the comparison of the synchronous and interleaved operation is presented. A 1-kW prototype is built and the experimental results show that the peak efficiency is 99.1% and 99.2% for synchronous and interleaved control, respectively. Additionally, the output current ripple of the interleaved operation is reduced by 85% in comparison with the synchronous operation.

14 SOLAR ENERGY↗

Dispatch Manager for NEML2 Constitutive Model Calculations Embedded in MOOSE

This report describes the extended capabilities of the NEML2 constitutive modeling library, including a flexible and efficient work dispatching system designed to leverage both CPU and GPU resources. This enhancement addresses one of the primary computational challenges in large-scale simulations: the ability to distribute and execute batches of material model evaluations across heterogeneous computing devices. The new dispatch system introduces a modular set of dispatcher and scheduler classes that coordinate the flow of data and execution between devices. The dispatcher is responsible for efficiently packaging work, managing device-specific memory operations, and synchronizing results. This modularity allows for extensibility, making it straightforward to integrate additional computing backends in the future. From an implementation standpoint, the dispatcher system interfaces seamlessly with NEML2's existing models. They handle device-aware tensor operations, optimize memory transfers, and support asynchronous execution when applicable. This design ensures that batches of material points can be evaluated concurrently, substantially improving throughput compared to previous single-device or serial implementations. These improvements not only enhance the raw performance of NEML2 but also improve its usability in multiscale and high-fidelity simulations, where the simultaneous evaluation of large material point batches is critical. Benchmarks included in the report demonstrate the system’s scalability, highlighting its effectiveness when leveraging modern GPU architectures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control and synchronization of rapid nanoscale DNA heat engine by local heating

To further activate devices based on DNA nanotechnology, we introduce an approach that notably enhances both the speed and force of DNA powered machines and artificial hinge machine. A microheater, with millisecond response, heats or recools DNA origami constructs, hybridizing or dehybridizing sticky ends. Because anything within 20 micrometers of the heater equilibrates to a programmed temperature change in milliseconds, sticky ends of a compound DNA origami machine can open and close synchronously and operate cooperatively, in phase, additively increasing the drive force compared to single pair of sticky ends DNA machine (the six-helix bundle DNA origami hinge machine). In our demonstrations, we fold and unfold two square origami with 10 pairs of complementary sticky ends to drive a bead on the end of a rod like origami to speeds exceeding 30 micrometers per second. Our device envisions the creation of complex, synchronized DNA machines.

Science & Technology - Other Topics↗

LEBT Buncher / Feed Forward / Frequency Generation: System Design Document (SDD)

The LAMP Low Energy Beam Transport (LEBT) transfers a continuous beam at 100 keV from the ion source to RFQ in LEBT. A LEBT buncher imposes an energy tilt to initiate velocy bunching in the chopped beam pulse about 25 ns long to form a short MPEG bunch. One possible option for the LEBT buncher based on a two-gap LC-circuit driven structure was considered, which is similar to the existing LANSCE low-frequncy buncher (LFB). Another possible option is a non-resonant element driven by a pulse-forming-network that provides a single pulse at the repetition frequency of MPEG beam, with a period of 1.8 µs. The LEBT operation is synchronized with the accelerator timing system.

43 PARTICLE ACCELERATORS↗

Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review

The relative share of renewable energy, specifically the solar photovoltaic (PV), is increasing exponentially in the world electric energy sector. This is a cumulative result of reduction in the cost of solar panels, improvement in the panel efficiency, and advancement in the associated power electronics. Among different types of PV plants, installation of small-scale rooftop PV is growing rapidly due to direct end-user benefits and lucrative governmental incentives. There are various standards developed in regards to grid integration of PVs and other distributed generations (DGs). Different power converter topologies are developed to interface the PV panel with the utility grid. To keep up with the stringent regulations imposed by the standards, various control strategies and grid synchronization methods have been developed. This review article amalgamates and summarizes all of the aforementioned aspects of a grid-integrated PV system including various standards, power stage architectures, grid synchronization methods, operation under extreme events, and control methodologies, pertaining to small-scale PV plants. This article will help freshman researchers to gain some familiarity with the topic and introduce them to some of the key issues encountered in this field.

14 SOLAR ENERGY↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.3)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.5)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Design Document (Rev. 0.2)

This design document proposes an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.6)

This document specifies an interface to support the multi-image parallelism features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a solution in which a runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. The Fortran compiler is responsible for transforming the invocation of Fortran-level multi-image parallelism features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.4)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗