Search NASASearch

SEARCH · Search NASA

Results for “synchrotron X-ray analyses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

428 records · Page 2

Ion Transport and Crystal Rotation in Plastic Crystal Electrolytes Under Applied Electric Fields

Organic ionic plastic crystal electrolytes, containing a plastic crystal and lithium salt, offer a potential balance between mechanical and electrochemical properties for solid state lithium-ion battery electrolytes. These electrolytes contain multiple mobile ionic species (three or four), resulting in complex transport mechanisms which have not yet been established. Plastic crystals are defined by long-range positional order and short-range rotational disorder. It is therefore necessary to quantify changes in the local crystal structure of the electrolyte as current flows through it. Herein, we examine the electrochemical properties of pyrrolidinium-based plastic crystal electrolytes containing lithium salt and zwitterion additives, including measurements of current fraction and limiting current. We obtain species-specific insight into electrolyte transport using pulsed-field gradient nuclear magnetic resonance spectroscopy and find that, while the zwitterion additive increases ionic conductivity, it decreases lithium diffusivity with respect to other ionic components. With operando spatiotemporally resolved wide-angle X-ray scattering we observe location-specific crystal rotations due to the passage of ionic current. In conclusion, we posit that reducing energy dissipation due to rotation is essential for using plastic crystal electrolytes in practical applications.

Yap, Kyra M. K. [University of California, Berkele

Dynamic nanodomains dictate macroscopic properties in lead halide perovskites

Lead halide perovskites have emerged as promising materials for solar energy conversion and X-ray detection owing to their remarkable optoelectronic properties. However, the microscopic origins of their superior performance remain unclear. Here we show that low-symmetry dynamic nanodomains present in the high-symmetry average cubic phases, whose characteristics are dictated by the A-site cation, govern the macroscopic behaviour. We combine X-ray diffuse scattering, inelastic neutron spectroscopy, hyperspectral photoluminescence microscopy and machine-learning-assisted molecular dynamics simulations to directly correlate local nanoscale dynamics with macroscopic optoelectronic response. Our approach reveals that methylammonium-based perovskites form densely packed, anisotropic dynamic nanodomains with out-of-phase octahedral tilting, whereas formamidinium-based systems develop sparse, isotropic, spherical nanodomains with in-phase tilting, even when crystallography reveals cubic symmetry on average. We demonstrate that these sparsely distributed isotropic nanodomains present in formamidinium-based systems reduce electronic dynamic disorder, resulting in a beneficial optoelectronic response, thereby enhancing the performance of formamidinium-based lead halide perovskite devices. By elucidating the influence of the A-site cation on local dynamic nanodomains, and consequently, on the macroscopic properties, we propose leveraging this relationship to engineer the optoelectronic response of these materials, propelling further advancements in perovskite-based photovoltaics, optoelectronics and X-ray imaging.

Materials Science

Lunar and Planetary X-Ray Diffraction Program: Progress Report of Research and Instrument Development, July 1964 to March 1965

The Lunar and Planetary X-Ray Diffraction Program consists of three concurrent efforts aimed at rapid development of a first-generation flight-instrument system, evaluation of potential advances in diffractometer components for a possible second-generation instrument, and full investigation of the capabilities and limitations of rock analysis by X-ray diffraction. More complete descriptions of each of these studies are given below; the papers which follow are grouped according to these subjects in Sections II through V.

PETROLOGY

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN

Stabilization Of The CN 3 5− Anion In Recoverable High‐pressure Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) Oxoguanidinates

Abstract A series of isostructural Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) oxoguanidinates was synthesized under high‐pressure (25–54 GPa) high‐temperature (2000–3000 K) conditions in laser‐heated diamond anvil cells. The crystal structure of this novel class of compounds was determined via synchrotron single‐crystal X‐ray diffraction (SCXRD) as well as corroborated by X‐ray absorption near edge structure (XANES) measurements and density functional theory (DFT) calculations. The Ln 3 O 2 (CN 3 ) solids are composed of the hitherto unknown CN 3 5− guanidinate anion—deprotonated guanidine. Changes in unit cell volumes and compressibility of Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) compounds are found to be dictated by the lanthanide contraction phenomenon. Decompression experiments show that Ln 3 O 2 (CN 3 ) compounds are recoverable to ambient conditions. The stabilization of the CN 3 5− guanidinate anion at ambient conditions provides new opportunities in inorganic and organic synthetic chemistry.

Chemistry

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas

X-Ray Polarization From the Atoll 4U 1735−44 Suggests a Low Inclination

X-ray polarimetry is a new tool capable of probing the geometry of accretion onto weakly magnetized neutron stars. Here we present the first X-ray spectro-polarimetric results from coordinated observations of the atoll source 4U 1735−44, conducted with the Imaging X-ray Polarimetry Explorer (IXPE), NICER, and NuSTAR . Over the 2–8 keV energy range, we obtained a marginal detection of polarization with the polarization degree of 1.4% ± 0.7% and polarization angle of −29◦ ± 14◦, corresponding to a 3σ upper limit on the polarization degree of 3.5%. The best-fit model to describe the spectrum comprises a thermal component associated with the accretion disk, a Comptonized black body component, and a relativistic reflection component. From the reflection model, we infer a disk inclination of ∼40◦. The spectroscopic and polarimetric properties of 4U 1735−44 are consistent with those observed in other atoll sources studied by IXPE, with its low polarization likely due to its low inclination

X-rays: binaries

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber