Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dual-RF Phase Control for Adiabatic Energy Ramping in the EIC Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) Rapid Cycling Synchrotron (RCS) accelerates electrons from 750 MeV to 10 GeV over approximately 64.7 ms. While the baseline design simultaneously ramps both RF voltage and phase, this study evaluates an alternative where RF cavities are divided into two groups, each operating at a fixed 6.5 MV, with the effective voltage synthesized through phase control. In the symmetric scheme (Option A), both groups vary symmetrically about the synchronous phase to provide exact matching of energy gain and synchrotron tune throughout the ramp. Conversely, the asymmetric scheme (Option B) pins one group at the final operating phase while the other varies to supply the required energy gain. The feasibility of Option B is determined by the adiabaticity of the resulting synchrotron tune evolution, with ramp profiles, phase trajectories, and adiabaticity metrics analyzed for both implementations.

Gamage, B. [Thomas Jefferson National Accelerator ↗

Reconnection-driven Flares in M87*: Proton–Synchrotron-powered GeV Emission

Magnetic reconnection in current layers that form intermittently in radiatively inefficient accretion flows onto black holes is a promising mechanism for particle acceleration and high-energy emission. It has been recently proposed that such layers, arising during flux eruption events, can power the rapid TeV flares observed from the core of M87. In this scenario, inverse-Compton scattering of soft radiation from the accretion flow by energetic electron–positron pairs produced near the reconnection layer was suggested as the primary emission mechanism. However, detailed calculations show that radiation from pairs alone cannot account for the GeV emission detected by the Fermi observatory. In this work, we combine analytic estimates with 3D radiative particle-in-cell simulations of pair–proton plasmas to show that the GeV emission can be naturally explained by synchrotron radiation from protons accelerated in the current sheet. Although the exact proton content of the layer is uncertain, our model remains robust across a broad range of proton-to-pair number density ratios. While protons are subdominant in number compared to pairs, our simulations demonstrate that they can be accelerated more efficiently, leading to a self-regulated steady state in which protons dominate the energy budget. Ultimately, proton synchrotron emission accounts for approximately 5%–20% of the total dissipation power. The majority is radiated as MeV photons via pair synchrotron emission, with a smaller fraction emitted as TeV photons through inverse-Compton scattering.

Active galactic nuclei↗

Melting temperature of bismuth to 55 GPa using synchrotron X-ray phase contrast imaging

The melting temperature of elemental bismuth under high pressure has been measured to 55 GPa using synchrotron X-ray phase-contrast imaging in the laser-heated diamond anvil cell. Imaging of solid-liquid interface formation, combined with radiometric temperature and X-ray diffraction measurements, reveals a pronounced reduction in melting boundary slope in Bi-V with pressure. The unusually steep initial slope is attributed to low configurational entropy of melting, arising from structural ordering and coordination matching in the cool liquid, while slope reduction is driven by entropy increase correlated with significant liquid structure changes with rising pressure and temperature. Finally, the data rule out kinetic effects on melting in shock compression experiments and demonstrate the need for improved theoretical phase diagrams.

Materials science↗

In situ Synchrotron X‐ray Metrology Boosted by Automated Data Analysis for Real‐time Monitoring of Cathode Calcination

Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.

36 MATERIALS SCIENCE↗

Oil-Pressure Based Apparatus for In-Situ High-Energy Synchrotron X-Ray Diffraction Studies During Biaxial Deformation

Background: Understanding biaxial loading response at the microstructural level is crucial in helping better design sheet manufacturing processes and calibrate/validate material deformation models. Objective: The objective of this work was to develop a low-cost testing apparatus to probe, with sufficient spatial resolution, the micro-mechanical response of a sheet material in-situ under biaxial loading conditions. Methods: The testing apparatus fabricated as a part of this study operates in a similar fashion to a standard bulge test and uses oil pressure to generate biaxial loading conditions. This biaxial testing apparatus was operated within a synchrotron beamline to characterize the mechanical response of a flash-processed steel sheet using in-situ high-energy X-ray diffraction (XRD) measurements. Further, the GSAS-II package was utilized to develop a workflow for the analysis of the large volume of diffraction data acquired. The workflow was then used to extract the peak position, width, and integrated intensity of the XRD peaks corresponding to the major body-centered cubic phase. Results: The equi-biaxial nature of the loading in the measured area was independently corroborated using experimental (XRD) and simulation (finite element analysis) methods. Furthermore, we discuss the evolution of elastic strain in the major body-centered cubic phase as a function of applied oil pressure and location on the steel sheet. Conclusions: A key advantage of the biaxial apparatus fabricated in this synchrotron study is demonstrated using the results obtained for the flash-processed steel sheet – i.e., mapping the lattice plane-dependent response to biaxial loading for a relatively large sample area in a spatially resolved manner.

36 MATERIALS SCIENCE↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗

Exploring the tempering behaviour of additively manufactured high-alloy tool steel using synchrotron X-ray and neutron techniques

Post-processing heat treatment provides a critical pathway toward the commercialisation of additively manufactured (AM) S390 high-speed steel, which is a representative high-alloy tool steel employed in precision manufacturing, offering up to 1.5 times longer tool life and over 20% higher cutting speeds compared to conventional grades. In this study, the phase evolution of AM S390 steel during heat treatment, with particular emphasis on carbide precipitation behaviour, was systematically investigated using a combination of synchrotron X-ray and neutron techniques. The metastable M2C carbides were found to dissolve during austenitisation, while the stable primary carbides MC and M6C experienced coarsening with an average size increase of about 60 nm after just 2 min of tempering. Moreover, the austenite lattice parameters reduced from 3.618 to 3.608 Å within the first 10 min of tempering, suggesting carbon depletion in the steel matrix was likely associated with the formation of secondary carbides. This interpretation was substantiated by small-angle scattering results, which revealed the presence of nanoscale precipitates with a volume fraction of 3.1% after 60 min of tempering. These microstructural evolutions collectively accounted for the observed peak hardness of 921 HV. Furthermore, a comparative analysis of synchrotron and neutron small-angle scattering data highlighted the complementary strengths of each technique, offering critical insight into their suitability for characterising nanoscale features in AM high-alloy steels.

Synchrotron X-ray diffraction↗

Understanding the deformation behavior of the γ rich transformative Fe 38.5 Mn 20 Co 20 Cr 15 Si 5 Cu 1.5 complex concentrated alloy using in situ synchrotron diffraction

In situ tensile testing coupled with synchrotron x-ray diffraction was used to study the deformation behavior of metastability-engineered Fe 38.5 Mn 20 Co 20 Cr 15 Si 5 Cu 1.5 complex concentrated alloy. Monitoring the evolution of phase fraction and strain hardening response allowed the determination of true critical stress for the onset of the transformation-induced plasticity (TRIP) to be ∼375 MPa, preceded by slip starting at ∼255 MPa. In situ EBSD was used to validate the critical stress for transformation at the microstructure level and observe slip traces to confirm prior slip activity before the transformation. Further, a modeling framework based on stacking fault energy (SFE) was developed to predict the critical stress for transformation. Modeling suggested the SFE of the alloy to fall nearly 15 mJ/m 2 , which agrees well with SFE values calculated using synchrotron peak shifting (12 mJ/m 2 ) and thermodynamic calculation (11 mJ/m 2 ). As a result of γ-fcc to ε-hcp phase transformation, new {0002} ε planes emerged parallel to unaligned {111} γ planes with the tensile loading following S-N orientation relationship. Such selective emergence of new diffraction rings corresponding to ε phase is understood based on the reorientation of γ crystals with reference to tensile axis. In conclusion, this approach can be extended to effectively design alloys based on critical stress required for activating different deformation mechanisms to further push the limits of the strength-ductility envelope.

Complex concentrated alloy↗

Probing the Mechanism of Selective Phosphate Adsorption from Wastewater Using Aqueous and Synchrotron X-ray Characterization

Ion exchange shows promise for recovering phosphate from wastewater as value-added products, but requires high phosphate selectivity to compete with conventional treatment. Hybrid anion exchange (HAIX) resins, which contain non-selective basic functional groups and selective iron oxide nanoparticles (FeOnp), can effectively remove phosphate from wastewater. However, knowledge gaps remain regarding the mechanisms of phosphate selectivity and influence of competing ions, hindering needed efforts to model adsorption dynamics and design scalable adsorption processes for varying wastewaters. To address these gaps, we integrated aqueous-phase adsorption analysis with solid-phase, synchrotron-based X-ray characterization; this integration facilitated elucidation of the distribution and speciation of iron, phosphate, and competing anions on HAIX resins. We compared a quaternary ammonium-functionalized HAIX resin (SBA) to a tertiary amine version (WBA) to determine the role of functional groups. X-ray radiography revealed differences in FeOnp speciation (goethite vs. ferrihydrite) and distribution (peripheral vs. homogeneous) between the resins, resulting in varied phosphate affinity and intraparticle diffusion resistance. Using micro-X-ray fluorescence (μ-XRF) and micro-X-ray absorption near-edge structure (μ-XANES) spectroscopy, we identified differences in where and how phosphate binds across resin types and wastewaters. Across wastewater compositions, FeOnp sites in WBA contribute more to phosphate adsorption than in SBA, possibly due to variations in Fe distribution and speciation. Phosphate adsorption densities calculated from quantitative μ-XRF maps matched those from aqueous analysis, demonstrating the effectiveness of this integrated approach. Altogether, results demonstrate the use of synchrotron-based X-ray characterization for investigating adsorption mechanisms and advance HAIX as a phosphate recovery technology from complex wastewaters.

Nutrient recovery↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Synchrotron-driven Instabilities in Relativistic Plasmas of Arbitrary Opacity

Recent work has shown that synchrotron emission from relativistic plasmas leads the electron distribution to form an anisotropic ring in momentum space, which can be unstable to both kinetic and hydrodynamic instabilities. Fundamental to these works was the assumption that the plasma was optically thin, allowing all emitted radiation to escape. Here, we examine the behavior of these instabilities as the plasma becomes more optically thick. To do this, we extend a recently developed Fokker–Planck operator for synchrotron emission and absorption in mildly relativistic plasmas to ultrarelativistic plasmas. For a given set of plasma parameters, photons emitted by higher-energy electrons tend to be higher frequency, and thus more easily escape the plasma. As a result, the ratio of the photon emission rate (radiative drag) to absorption rate (radiative diffusion) for a given electron is extremely energy dependent. Given this behavior, we determine the critical parameters that control the opacity, and show how the plasma gradually transitions to become more isotropic and stable at higher opacity.

79 ASTRONOMY AND ASTROPHYSICS↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

Rotating synchrotron radiation: Photon emission from magnetized and rotating quark-gluon plasma

This paper investigates the production of nonprompt photons originating from rotating synchrotron radiation (RoSyRa), specifically the emission of photons by a rigidly rotating quark-gluon plasma in thermal equilibrium, in the presence of an external magnetic field. We compute the nonprompt photon spectrum and its elliptic flow (𝑣 2 ) at midrapidity. In particular, we investigate the finite-volume effects. We find that at low transverse momentum, the magnetic field induces a significant 𝑣 2 , while the plasma rotation boosts the synchrotron radiation of negatively charged quarks. These findings make RoSyRa a viable candidate mechanism to resolve the “direct photon puzzle.”

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure refinement and anisotropic atomic displacement parameters of 1M Illite: Rietveld and pair distribution function analysis using synchrotron X-ray radiation

Illite, a widespread clay mineral, plays a pivotal role in geological processes, notably as an indicator in diagenetic and hydrothermal alteration environments, and possesses significant industrial relevance in applications including ceramics, construction and catalysis. However, challenges including its nanoscale crystallinity, structural disorder and frequent interstratification with other clay minerals have hindered detailed structural characterization using conventional X-ray diffraction (XRD) techniques. This study employs integrated synchrotron XRD and pair distribution function (PDF) analysis to elucidate the crystal structure of the 1M illite polytype, yielding the first determination of its anisotropic atomic displacement parameters (U aniso ). TheseU aniso parameters provide critical insights into atomic dynamics and static disorder within the structure, enabling a more refined understanding of structure–property relationships. This integrated approach, combining synchrotron XRD, Rietveld refinement and PDF analysis, yields a comprehensive structural characterization, capturing both average crystallographic and local atomic arrangements. Considering illite's widespread geological occurrence and industrial importance, this high-precision structural dataset, especially the determinedU aniso values, provides a crucial benchmark for future modeling and simulation efforts targeting accurate prediction of its physicochemical behavior.

Chemistry↗

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗