Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

RESULTS FOR THE FOURTH QUARTER TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, the DDA (Deliquification, Dissolution, and Adjustment) process, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are listed in the current Saltstone WAC. SRS Liquid Waste Operations (LWO) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2009 Fourth Quarter samples collected from Tank 50 on October 2, 2009 and discusses those results in further detail than the previously issued results report. This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (3) The reported detection limits for {sup 59}Ni and {sup 94}Nb are above the requested limits from Reference 4. However, they are each below the limits established in Reference 3. (4) The reported detection limit for isopropanol is greater than the requested limit from Table 4 of the WAC. (5) The reported detection limits for {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FOR THE FIRST QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (3) The reported detection limits for {sup 59}Ni and {sup 94}Nb are above the requested limits from Reference 4. However, they are each below the limits established in Reference 6. (4) The reported detection limit for isopropanol is greater than the requested limit from Table 4 of the WAC. (5) The reported detection limits for 247Cm and 249Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 6. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-Induced Carbon-Based Smart Flexible Sensor Array for Multiflavors Detection

We report a flexible sensor array electronic tongue system that is fabricated on a polymer substrate by the laser direct writing process for multiflavor detection. Electronic tongue is a sensing system that is applied to detect different elements with the same sensor array. By analyzing responses from different measurement units, it enables a cross-sensitivity, namely, the ability of the system to responding to a range of different analytes in solution without specific functionalization of sensors. In this article, a six-unit sensing array system was fabricated by a laser direct writing process. Sensing units were introduced on a flexible polyamide surface. A high surface–volume ratio porous carbon structure was created by a laser-induced carbonization process, which provides stable conductive carbon electrodes with high sensitivity. Different surface treatments, such as gold plating, reduced-graphene oxide coating, and polyaniline coating, were accomplished for different measurement units. By applying principal component analysis, this sensing system shows a promising result for the detection of multiple flavors. The detection limit for each element is about 0.1 mM for NaCl and sugar solutions. Also, it is able to detect 10 –4 times diluted commercial table vinegar solution, which originally contains 5% acetic acid. The detection limit is theoretically lower than the human threshold of 10 mM for NaCl and sugar. Besides, the sensing system shows a high sensitivity and selectivity for mixed elements. Here, by mapping the data points, the sensor system could detect flavor combinations and provide a reliable prediction of analyte concentration ratios.

47 OTHER INSTRUMENTATION↗

Epi Archive: Automated Synthesis of Global Notifiable Disease Data

ObjectiveLANL has built software that automatically collects global notifiable disease data, synthesizes the data, and makes it available to humans and computers within the Biosurveillance Ecosystem (BSVE) as a novel data stream. These data have many applications including improving the prediction and early warning of disease events.IntroductionMost countries do not report national notifiable disease data in a machine-readable format. Data are often in the form of a file that contains text, tables and graphs summarizing weekly or monthly disease counts. This presents a problem when information is needed for more data intensive approaches to epidemiology, biosurveillance and public health.While most nations likely store incident data in a machine-readable format, governments are often hesitant to share data openly for a variety of reasons that include technical, political, economic, and motivational issues1.A survey conducted by LANL of notifiable disease data reporting in over fifty countries identified only a few websites that report data in a machine-readable format. The majority (>70%) produce reports as PDF files on a regular basis. The bulk of the PDF reports present data in a structured tabular format, while some report in natural language.The structure and format of PDF reports change often; this adds to the complexity of identifying and parsing the desired data. Not all websites publish in English, and it is common to find typos and clerical errors.LANL has developed a tool, Epi Archive, to collect global notifiable disease data automatically and continuously and make it uniform and readily accessible.MethodsWe conducted a survey of the national notifiable disease reporting systems notating how the data are reported and in what formats. We determined the minimal metadata that is required to contextualize incident counts properly, as well as optional metadata that is commonly found.The development of software to regularly ingest notifiable disease data and make it available involves three or four main steps: scraping, detecting, parsing and persisting.Scraping: we examine website design and determine reporting mechanisms for each country/website, as well as what varies across the reporting mechanisms. We then designed and wrote code to automate the downloading of the data for each country. We store all artifacts presented as files (PDF, XLSX, etc.) in their original form, along with appropriate metadata for parsing and data provenance.Detecting: This step is required when parsing structured non-machine-readable data such as tabular data in PDF files. We combined the Nurminen methodology of PDF table detection with in-house heuristics to find the desired data within PDF reports2.Parsing: We determined what to extract from each dataset and parsed these data into uniform data structures, correctly accommodating the variations in metadata (e.g., time interval definitions) and the various human languages.Persisting: We store the data in the Epi Archive database and make it available on the internet and through the BSVE. The data is persisted into a structured and normalized SQL database.ResultsThe Epi Archive tool currently contains national and/or subnational notifiable disease data from twenty nations. When a user accesses the Epi Archive site, they are prompted with four fields: country, subregion, disease of interest, and date duration. Upon form submission, a time series is generated from the users’ specifications. The generated graph can then be downloaded into a CSV file if a user is interested in performing personal analysis. Additionally, the data from Epi Archive can be reached through a REST API (Representational State Transfer Application Programming Interface).ConclusionsLANL, as part of a currently funded DTRA effort, is automatically and continually collecting global notifiable disease data. While 20 nations are in production, more are being brought online in the near future. These data are already being utilized and will have many applications including improving the prediction and early warning of disease events.References[1] van Panhuis WG, Paul P, Emerson C, et al. A systematic review of barriers to data sharing in public health. BMC Public Health. 2014. 14:1144. doi:10.1186/1471-2458-14-1144[2] Nurminen, Anssi. "Algorithmic extraction of data in tables in PDF documents." (2013).

Khalsa, Hari S.↗

SU-E-T-465: Implementation of An Automated Collision Detection Program Using Open Source Software for the Pinnacle Treatment Planning System

Purpose: Potential collisions between the gantry head and the patient or table assembly are difficult to detect in most treatment planning systems. We have developed and implemented a novel software package for the representation of potential gantry collisions with the couch assembly at the time of treatment planning. Methods: Physical dimensions of the Varian Edge linear accelerator treatment head were measured and reproduced using the Visual Python display package. A script was developed for the Pinnacle treatment planning system to generate a file with the relevant couch, gantry, and isocenter positions for each beam in a planning trial. A python program was developed to parse the information from the TPS and produce a representative model of the couch/gantry system. Using the model and the Visual Python libraries, a rendering window is generated for each beam that allows the planner to evaluate the possibility of a collision. Results: Comparison against heuristic methods and direct verification on the machine validated the collision model generated by the software. Encounters of <1 cm between the gantry treatment head and table were visualized as collisions in our virtual model. Visual windows were created depicting the angle of collision for each beam, including the anticipated table coordinates. Visual rendering of a 6 arc trial with multiple couch positions was completed in under 1 minute, with network bandwidth being the primary bottleneck. Conclusion: The developed software allows for quick examination of possible collisions during the treatment planning process and helps to prevent major collisions prior to plan approval. The software can easily be implemented on future planning systems due to the versatility and platform independence of the Python programming language. Further integration of the software with the treatment planning system will allow the possibility of patient-gantry collision detection for a range of treatment machines.

60 APPLIED LIFE SCIENCES↗

Product Consistency Test and Vapor Hydration Test Comparisons of a Radioactive Hanford Waste Glass with its Non-Radioactive Simulant Glass

Product Consistency Tests (PCT) and Vapor Hydration Tests (VHT) were performed on a radioactive glass made from Hanford tank AP-107 waste (i.e., R-AP-107) and its non-radioactive equivalent glass made from simulated tank waste (i.e., S-AP-107). The radioactive and non-radioactive experiments were conducted in parallel with identical equipment, protocols, and staff to remove additional experimental uncertainties. PCT and VHT results are reported for all samples and are shown in Table S.1. Average normalized mass loss of B ( NL B ) and Na ( NL Na ) calculated from the three replicate test results for each glass with their respective standard deviations (SD) are presented for PCT results while individual VHT rates ( r VHT ) with their propagated errors ( σ r prop ) from individual thickness measurements on each sample are presented for the VHT results. Some VHT samples experienced more than 50% evaporation loss during the experiments. However, no visible alteration was detected on any VHT samples regardless on the amount of evaporation loss detected as shown in Table S.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-sample discrimination of Poisson means

This paper presents a statistical test for detecting significant differences between two random count accumulations. The null hypothesis is that the two samples share a common random arrival process with a mean count proportional to each sample's exposure. The model represents the partition of N total events into two counts, A and B, as a sequence of N independent Bernoulli trials whose partition fraction, f, is determined by the ratio of the exposures of A and B. The detection of a significant difference is claimed when the background (null) hypothesis is rejected, which occurs when the observed sample falls in a critical region of (A, B) space. The critical region depends on f and the desired significance level, alpha. The model correctly takes into account the fluctuations in both the signals and the background data, including the important case of small numbers of counts in the signal, the background, or both. The significance can be exactly determined from the cumulative binomial distribution, which in turn can be inverted to determine the critical A(B) or B(A) contour. This paper gives efficient implementations of these tests, based on lookup tables. Applications include the detection of clustering of astronomical objects, the detection of faint emission or absorption lines in photon-limited spectroscopy, the detection of faint emitters or absorbers in photon-limited imaging, and dosimetry.

Lampton, M.↗

Axion detection via topological Casimir effect

We propose here a new table-top experimental configuration for the direct detection of dark matter QCD axions in the traditional open mass window 10 - 6 eV ≲ m a ≲ 10 - 2 eV using nonperturbative effects in a system with nontrivial spatial topology. Different from many experimental setups found in literature on direct dark matter axion detection, which relies on θ ˙ or ∇ → θ , we found that our system is in principle sensitive to a static θ ≥ 10 - 14 and can also be used to set limit on the fundamental constant θ QED which becomes the fundamental observable parameter of the Maxwell system if some conditions are met. Furthermore, the proposed experiments can probe entire open mass window 10 - 6 eV ≲ m a ≲ 10 - 2 eV with the same design, which should be contrasted with conventional cavity-type experiments being sensitive to a specific axion mass. Connection with Witten effect when the induced electric charge e ' is proportional to θ and the magnetic monopole becomes the dyon with nonvanishing e ' = - e θ 2 π is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Erratum to “Systematic Trends of $0^+_2$, $1^-_1$, $3^-_1$ and $2^+_1$ Excited States in Even-Even Nuclei” [Nucl. Phys. A 1027 (2022) 122511]

In our publication [Nucl. Phys. A 1027 (2022) 122511, https://doi.org/10.1016/j.nuclphysa.2022.122511] we have detected typographical errors in Table 4 [List of $2^+_1$ States in Even-Even Nuclei]. The misprints of decimals with one or more trailing zeros are not central to our findings, however, they may confuse the journal readers and require corrections. In addition, we have included recent results for the $0^+_2$ and $2^+_1$ first excited states that are not available in the ENSDF library as of April, 2021 or B(E2) tables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding papers in this area were addressed. Errors in the measured T gas values were found for given errors in the experimental and spectroscopic values. The ionization energy of the neutral polyatomic ion was included in calculations to prove the validity of ignoring more complicated equilibria. Work was begun on the question of agreement between kinetics of the plasma and interface and the increase and depletion seen in certain polyatomic ions. This dissertation was also the first to report day to day ranges for T gas values and to use a statistical test to compare different operating conditions. This will help guide comparisons of previous and future work. Chapter 4 was the first attempt to include the excited electronic state 2 in the partition function of ArO + as well as the first to address the different dissociation products of the ground and first electronic levels of ArO + . Chapter 5 reports an interesting source of memory in ICP-MS that could affect mathematical corrections for polyatomic ions. For future work on these topics I suggest the following experiments and investigations. Clearly not an extensive list, they are instead the first topics curiosity brings to mind. (1) Measurement of T gas values when using the flow injection technique of Appendix B. It was believed that there was a fundamental difference in the plasma when the auto-sampler was used versus a continuous injection. Is this reflected in T gas values? (2) The work of Chapter 3 can be expanded and supplemented with more trials, new cone materials (i.e. copper, stainless steel) and more cone geometries. Some of this equipment is already present in the laboratory, others could be purchased or made. (3) T gas values from Chapter 3 could be correlated with instrument pressures during the experiment. Pressures after the skimmer cone were recorded for many days but have yet to be collated with the measured T gas values. (4) The work in Chapter 5 could be expanded to include more metals. Does the curious correlation between measured T gas and element boiling point persist? (5) Investigate non-linear correlations to T gas values of the MO + memory in Chapter 5. Temperatures along the skimmer walls are not a linear gradient. Ring deposits have been observed on the cone and photographs of the interface show light intensities shaping a sort of tailing peak along the outside skimmer wall. Is there a physical property of the metals or metal oxides that would give this peak with the T gas values? (6) Chemical state speciation of the metal deposits on the skimmers of Chapter 5. There may be a more logical correlation between Tgas and a physical property of the deposit-ing chemical if all the metals do not deposit in the same form. (7) A collaboration with our computational collegues would be most welcome. Newer calculations for ArO + and RuO + would be very helpful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ratio of solid to gas phase CO in the line of sight to W33A

Spectroscopic observations of the IR source W33A, obtained in the M band (4.6 microns) at resolution 0.057/cm using the Fourier-transform spectrometer at the Cassegrain focus of the Canada-France-Hawaii Telescope on July 12-13, 1987, are reported. The spectrum is shown, and equivalent widths and CO column densities are presented in tables. The absorption lines detected indicate the presence of gas at both 23 and 120 K, attributed to the molecular-cloud core and gas near the source, respectively, but very little solid-phase CO.

Mitchell, George F.↗

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

Demonstrating the Safety and Reliability of a New System or Spacecraft: Incorporating Analyses and Reviews of the Design and Processing in Determining the Number of Tests to be Conducted

Design Safety/Reliability is associated with the probability of no failure-causing faults existing in a design. Confidence in the non-existence of failure-causing faults is increased by performing tests with no failure. Reliability-Growth testing requirements are based on initial assurance and fault detection probability. Using binomial tables generally gives too many required tests compared to reliability-growth requirements. Reliability-Growth testing requirements are based on reliability principles and factors and should be used.

Vesely, William E.↗

Radar-Sounding Characterization of the Subglacial Groundwater Table Beneath Hiawatha Glacier, Greenland

Radar-sounding surveys associated with the discovery of a large impact crater beneath Hiawatha Glacier, Greenland, revealed bright, flat subglacial reflections hypothesized to originate from a subglacial groundwater table. We test this hypothesis using radiometric and hydrologic analysis of those radar data. The dielectric loss between the reflection from the top of the basal layer and subglacial reflection and their reflectivity difference represent dual constraints upon the complex permittivity of the basal material. Either ice-cemented debris or fractured, well-drained bedrock explain the basal layer's radiometric properties. The subglacial reflector's geometry is parallel to isopotential hydraulic head contours, located 7.5–15.3 m below the interface, and 11 ± 7 dB brighter than the ice–basal layer reflection. We conclude that this subglacial reflection is a groundwater table and that its detection was enabled by the wide bandwidth of the radar system and unusual geologic setting, suggesting a path for future direct radar detection of subglacial groundwater elsewhere.

Johnathan T. Bessette↗

MMIC Amplifiers and Wafer Probes for 350 to 500 GHz

A wireless avionics interface exploits the constrained nature of data networks in flight systems to use a lightweight routing method. This simplified routing means that a processor is not required, and the logic can be implemented as an intellectual property (IP) core in a field-programmable gate array (FPGA). The FPGA can be shared with the flight subsystem application. In addition, the router is aware of redundant subsystems, and can be configured to provide hot standby support as part of the interface. This simplifies implementation of flight applications requiring hot stand - by support. When a valid inbound packet is received from the network, the destination node address is inspected to determine whether the packet is to be processed by this node. Each node has routing tables for the next neighbor node to guide the packet to the destination node. If it is to be processed, the final packet destination is inspected to determine whether the packet is to be forwarded to another node, or routed locally. If the packet is local, it is sent to an Applications Data Interface (ADI), which is attached to a local flight application. Under this scheme, an interface can support many applications in a subsystem supporting a high level of subsystem integration. If the packet is to be forwarded to another node, it is sent to the outbound packet router. The outbound packet router receives packets from an ADI or a packet to be forwarded. It then uses a lookup table to determine the next destination for the packet. Upon detecting a remote subsystem failure, the routing table can be updated to autonomously bypass the failed subsystem.

Samoska, Lorene A.↗

Interface Supports Lightweight Subsystem Routing for Flight Applications

A wireless avionics interface exploits the constrained nature of data networks in flight systems to use a lightweight routing method. This simplified routing means that a processor is not required, and the logic can be implemented as an intellectual property (IP) core in a field-programmable gate array (FPGA). The FPGA can be shared with the flight subsystem application. In addition, the router is aware of redundant subsystems, and can be configured to provide hot standby support as part of the interface. This simplifies implementation of flight applications requiring hot stand - by support. When a valid inbound packet is received from the network, the destination node address is inspected to determine whether the packet is to be processed by this node. Each node has routing tables for the next neighbor node to guide the packet to the destination node. If it is to be processed, the final packet destination is inspected to determine whether the packet is to be forwarded to another node, or routed locally. If the packet is local, it is sent to an Applications Data Interface (ADI), which is attached to a local flight application. Under this scheme, an interface can support many applications in a subsystem supporting a high level of subsystem integration. If the packet is to be forwarded to another node, it is sent to the outbound packet router. The outbound packet router receives packets from an ADI or a packet to be forwarded. It then uses a lookup table to determine the next destination for the packet. Upon detecting a remote subsystem failure, the routing table can be updated to autonomously bypass the failed subsystem.

Lux, James P.↗

The Shuttle Orbital Maneuvering System P-V-T Propellant Quantity Gaging Accuracy and Leak Detection Allowance for Four Instrumentation Conditions

The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.

Duhon, D. D.↗

RESULTS FOR THE FIRST QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2009 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the chemical and radioactive contaminants were all less than their respective WAC Targets or Limits except for Am-242m. (2) The radionuclide Am-242m was not detected; however, its detection limit is above the WAC Target given in Attachment 8.4. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (3) The reported detection limit of isopropanol was lower than its WAC Limit for accident analysis but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit was expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of these analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗