Search NASA⌕ Search

SEARCH · Search NASA

Results for “tablet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of Tablet-Based Methods for Assessment of Contrast Sensitivity

Some astronauts have suffered degradation of vision during long-duration space flight, suffering from a condition that has come to be known as Spaceflight Associated Neuro-ocular Syndrome (SANS). While related morphological changes can be observed with imaging technologies such as optical coherence tomography (OCT), it may be useful to have a rapid method for functional vision assessment. In this paper, we compare three tablet-based methods for rapid assessment of contrast sensitivity. First, a relatively novel method developed expressly for touch screens, in which the subject ”swipes” a frequency/contrast sweep grating to indicate the boundary between visible and invisible patterns; second, a method-of-adjustment task in which the subject adjusts the contrast of a grating patch up and down to bracket the visual threshold; and third, a traditional temporal two-alternative forced choice (2AFC) task, in which the subject is presented with a near-threshold stimulus in one of two intervals, and must report the interval containing the stimulus. The swipe method shows variability comparable to the 2AFC method, and shows good agreement in estimates of the spatial frequency of peak sensitivity. The absolute sensitivity estimated with the swipe method is higher than that of the other methods, perhaps because subjects are biased to trace outside of the visible pattern region, or perhaps due to stimulus differences.

Mulligan, Jeffrey B.↗

Tablet based distributed intelligent load management

A facility is connected to an electricity utility and is responsive to Demand Response Events. A plurality of devices is each individually connected to the electricity grid via an addressable switch connected to a secure network that is enabled to be individually switched off by a server. An occupant of a room in control of the plurality of devices provides via a Human Machine Interface on a tablet a preferred order of switching off the plurality of devices in case of a Demand Response Event. A configuration file based at least partially on the preferred order and on a severity of the Demand Response Events determines which devices which of the plurality devices will be switched off. The server accesses the configuration file and switches off the devices included in the configuration file.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor Suitcase Tablet Software

The Retrocommissioning Sensor Suitcase is targeted for use in small commercial buildings of less than 50,000 square feet of floor space that regularly receive basic services such as maintenance and repair, but don't have in-house energy management staff or buildings experts. The Suitcase is designed to be easy-to-use by building maintenance staff, or other professionals such as telecom and alarm technicians. The software in the hand-held is designed to guide the staff to input the building and system information, deploy the sensors in proper location, configure the sensor hardware, and start the data collection.

Source record↗

The use of laser-induced shock wave plasma spectroscopy (LISPS) for examining physical characteristics of pharmaceutical products

An experimental study has been performed to examine the physical characteristics of pharmaceutical products, such as tablet, by employing an emission plasma induced by Nd-YAG laser at a low pressure of Helium gas. The hardness of tablet is one of the parameters that examined during the production process for standard quality of pharmaceutical products. In the Laser-Induced Shock Wave Plasma Spectroscopy (LISPS), the shock wave has a significant role in inducing atomic excitation. It was known that, the speed of the shock wavefront depends on the hardness of the sample, and it correlates with the ionization rate of the ablated atoms. The hardness of the tablet is examined using the intensity ratio between the ion of Mg (II) 275.2 nm and the neutral of Mg (I) 285.2 nm emission lines detected from the laser-induced plasma. It was observed that the ratio changes with respect to the change in the tablet hardness, namely the ratio is higher for the hard tablet. Besides the ratio measurements, we also measured the depth profile of a tablet by focusing 60 shots of irradiation of laser light at a fixed position on the surface of the tablet. It was found that the depth profile varies differently with the hardness of the tablet. These experiment results show that the technique of LISPS can be applied to examine the quality of pharmaceutical products.

36 MATERIALS SCIENCE↗

Urine Pretreat Injection System

A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate providing the proper concentration in the collected urine. To implement the solid tablet in a bag approach, a design concept was completed with prototype drawings of the complete urine pretreat prefilter assembly. A successful fabrication technique was developed for retaining the Oxone tablets in a fabric casing attached to the end of the existing Space Station Waste Collection System urine prefilter assembly. The final pretreat prefilter configuration held sufficient Oxone in a tablet form to allow normal scheduled daily (or twice daily) change out of the urine filter depending on the use rate of the Space Station urine collection system. The actual tests to prove the concept were conducted using the Urine Fan/Separator assembly that was originally used in the STS-52 Design Test Objective (DTO) urinal assembly. Other related tests were conducted to demonstrate the actual minimum ratio of Oxone to urine that will control microbial growth.

Source record↗

Supervisory Control with Dual Tasking in Post G-Transition Vehicle Landings

BACKGROUND Landing during exploration spaceflight may consist of both planned automated supervisory control and unplanned crew override. Supervisory control, particularly when performed under cognitive load with additional monitoring tasks, is essential for ensuring overall mission success during landing contingencies. Evaluating performance in a relevant Human Landing System (HLS) supervisory landing task after long-duration microgravity exposure can help identify potential risks from human error and sensorimotor alterations. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. Although training and landing aids facilitate successful landings despite disorientation, these adaptive changes may heighten cognitive demand, which must be considered in the landing strategy. It is important to characterize these effects as soon as possible following the G-transition while the sensorimotor system remains in a state of adaptive flux to inform appropriate countermeasures. METHODS A Multi-attribute Lunar Table Battery (MALTB) task was developed for an iOS tablet device to provide flexible crew testing and training capabilities in-flight and on the ground. Elements of the tablet task were derived from the Multi-Attribute Task Battery (MATB, Cegarra et al. 2020). The task requires crew members to study a map of a planned landing site and memorizing the terrain and surface landmarks to inform potential divert maneuvers during landing. The user will oversee a series of approaches through touchdown simulations on the tablet with an external camera view of the Lunar surface. The primary responsibility of the crew member will be to execute a divert if the guidance recommended site is erroneous (e.g., the guidance projected landing target is not within 10m of the planned landing site center), or the projected landing site is no longer suitable due to surface obstacles. Considering vehicle maneuverability and fuel reserves, the divert capabilities will diminish as the task progresses. In cases where a divert is initiated, a new landing target will need to be designated by the user and will be evaluated for the proximity to the original pre-planned site. A secondary operational monitoring task will challenge the user's cognitive reserve by requiring the user to maintain several gauges within acceptable limits and respond to a visual indicator while completing the landing approach. Outcome measures include distance from the planned landing site to the user-initiate divert landing location, ground slope at the new landing site, time to divert, the ability to accomplish the secondary monitoring tasks, and perceived workload. The tablet task is being evaluated in a ground-based study to determine the learning effect of first-time users. The tablet task will be utilized in a flight study to test performance multiple times postflight. Future potential testing in-flight have been identified for capsules with iOS tablet devices. Multi-attribute Lunar Table Battery Task MALTB comprises video footage of thirty distinct landing conditions. The landing scenarios feature various landing sites (n = 3), hazardous object sizes (n = 6), sun azimuth degrees (n = 4), camera modes (i.e., fixed or gimbaled), and navigation bias (i.e., true or false). Each seventy second trial uses a sixty-degree constant glideslope trajectory. The application architecture and layout include user identification setup and data storing, a guided walkthrough of the task and interface components, practice mode for task familiarization, and a modified Bedford workload scale administered following task completion. The time-based dependent measures are saved locally to the iOS Files application and post-processing scripts have been developed to evaluate the remaining measures of performance. RELEVANCE This project will deliver an operational demonstration of crew monitoring capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew performance will help better characterize the landing risks associated with sensorimotor alterations. ACKNOWLEDGEMENTS: This project is funded by NASA’s Human Research Program Human Health Countermeasures Element. REFERENCES Cegarra J, Valery B, Avril E, Calmettes C, Navarro J (2020) OpenMATB: A Multi-Attribute Task Battery promoting task customization, software extensibility and experiment replicability. Behav Res Methods 52:1980-1990 doi: 10.3758/s13428-020-01364-w

Matthew McDonnell↗

The mesoscale order of nacreous pearls

A pearl’s distinguished beauty and toughness are attributable to the periodic stacking of aragonite tablets known as nacre. Nacre has naturally occurring mesoscale periodicity that remarkably arises in the absence of discrete translational symmetry. Gleaning the inspiring biomineral design of a pearl requires quantifying its structural coherence and understanding the stochastic processes that influence formation. By characterizing the entire structure of pearls (~3 mm) in a cross-section at high resolution, we show that nacre has medium-range mesoscale periodicity. Self-correcting growth mechanisms actively remedy disorder and topological defects of the tablets and act as a countervailing process to long-range disorder. Nacre has a correlation length of roughly 16 tablets (~5.5 µm) despite persistent fluctuations and topological defects. For longer distances (>25 tablets ~8.5 µm), the frequency spectrum of nacre tablets follows f –1.5 behavior, suggesting that growth is coupled to external stochastic processes—a universality found across disparate natural phenomena, which now includes pearls.

36 MATERIALS SCIENCE↗

Relative Bioavailability of Scopolamine Dosage Forms and Interaction with Dextroamphetamine

The NASA Reduced Gravity Office (RGO) uses scopolamine (SCOP) and in combination with dextoamphetamine (DEX) to manage motion sickness symptoms during parabolic flights. The medications are dispensed as custom dosage forms as gelatin capsules. Anecdotal evidence of efficacy suggests that these formulations are unreliable and less efficacious for the treatment of motion sickness. We estimated bioavailability of four different oral formulations used by NASA for the treatment of motion sickness. Twelve healthy, non-smoking subjects between 21and 48 years of age received four treatments on separate days in a randomized fashion; the treatments were 0.8 mg SCOP alone as tablet, 0.8 mg SCOP alone in gel cap, 0.8 mg SCOP and 10 mg DEX as tablets, and 0.8 mg SCOP and 10 mg DEX in gel cap. After each treatment, blood, saliva, and urine samples were collected at scheduled time intervals for 24 h after dosing. Bioavailability and pharmacokinetic parameters were calculated and compared using ANOVA. After administration of SCOP tablets alone, maximum concentration (C(sub max)) and time for maximum concentration (t(sub max)) were 0.26 plus or minus 0.04 ng/mL and 0.71 plus or minus 0.02 h, respectively; volume of distribution, and clearance were 47.6 plus or minus 4.72 L/kg and 23.0 plus or minus 4.58 L/h/kg, respectively. SCOP t(sub max) after administration as gelcaps was significantly longer than that with tablets (1.04 h, p less than 0.05), but no significant differences in other pharmacokinetic parameters of SCOP were observed between the two dosage forms. When coadministered with DEX, the area underneath the concentration versus time curve (AUC) of SCOP was significantly reduced to 0.61 plus or minus 0.09 and 0.64 plus or minus 0.11 ng (raised dot) h/mL after administration as a tablet or gelcap formulation, respectively; SCOP C(sub max) was lower after coadministration with DEX, this difference, however, was not statistically significant. Delayed absorption with gelcaps coupled with reduced bioavailability with DEX coadministration may have resulted in the observed treatment failure with some of these formulations. This could result from failure to reach minimum effective concentrations after treatment with gelcap formulations before parabolic flights. A new nomogram for dosing is proposed for treatment with SCOP gelcaps or SCOP-DEX combination.

Boyd, Jason L.↗

Urine Pretreatment Configuration and Test Results for Space Applications

Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

Howard, Stanley G.↗

Hazardous Product Detection and Environmental Clean-up Removal in Spacecraft Vehicles from Fire Induced Li-Ion Fires

A fire on-board the International Space Station (ISS) resulting from a commercial Surface Pro tablet Lithium-Ion (Li-ion) battery can be detrimental to the spacercraft and the astronauts. The Spacecraft Fire Safety Demonstration (Saffire) program is focused on identifying and quantifying the risks that potentially arise inside a space vehicle by conducting large fire experiments inside the Cygnus cargo vehicle upon re-entry to Earth. The potential candidate that will be flown on the ISS is a 4- cell Li-ion battery pack Surface Pro tablet (42 Wh). The tablets were tested at the White Sands Test Facility (WSTF) using a localized heating method to emulate the failing mechanism that leads the unit into thermal runaway. Measurements inside the test chamber were performed on aerosol mass concentrations and for specific toxic products (i.e. from CO, HCN, HCl and CO2). These toxic products depend on the size of the fire and energy content of the tablet. Comparisons will be made with the Dell XPS (97 Wh). The concentrations are then used to extrapolate to laptop fires on a vehicle at the approximate volumetric size of the Orion spacecraft. The presentation provides an analysis on the detection capability and the response time to trigger fire alarms aboard a vehicle by using the mass concentration levels. These results will consider the rate at which the life support system is able to filter the atmosphere in order to provide a hazardous free environment.

Padilla, Rosa E.↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗