Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Compensatory islet response to insulin resistance revealed by quantitative proteomics

Compensatory islet response is a distinct feature of the pre-diabetic insulin resistant state in humans and rodents. To identify alterations in the islet proteome that characterize the adaptive response, we analyzed islets from five-month-old male control, high-fat diet fed (HFD) or obese ob/ob mice by LC-MS(/MS) and quantified ~1,100 islet proteins (at least two peptides) with a false discovery rate <1%. Significant alterations in abundance were observed for ~350 proteins between groups. A majority of alterations were common to both models, and the changes of a subset of ~40 proteins and 12 proteins were verified by targeted quantification using selected reaction monitoring and Western blots, respectively. The insulin resistant islets in both groups exhibited reduced expression of proteins controlling energy metabolism, oxidative phosphorylation, hormone processing, and secretory pathways. Conversely, an increased expression of molecules involved in protein synthesis and folding suggested effects in endoplasmic reticulum stress response, cell survival, and proliferation in both insulin resistant models. In conclusion, we report a unique comparison of the islet proteome that is focused on the compensatory response in two insulin resistant rodent models that are not overtly diabetic. In conclusion, these data provide a valuable resource of candidate proteins to the scientific community to undertake further studies aimed at enhancing β-cell mass in patients with diabetes. The data are available via the MassIVE repository, with accession MSV000079093.

59 BASIC BIOLOGICAL SCIENCES↗

Uncertainty Quantification of Monolithic Tungsten Target Block Fatigue

The current STS spallation target design consists of 21 water cooled, tantalum clad, monolithic tungsten blocks. The target wheel assembly rotates such that each target block receives a direct proton pulse every 1.4 seconds (21 blocks / 15 Hz pulses). The quasi-steady heating induced by the repetitive beam pulses creates a significant mean stress distribution in the target. On top of this, the rapid energy deposition from a proton pulse induces dynamic stress waves that are of the same order of magnitude as the mean stresses. Over the design goal of 5,000 operational hours per year for a decade, each target must withstand over 130 million repetitions of these dynamic stress events. The fatigue life prediction of the target blocks is a complex sequence of simulations that depend upon a set of input parameters. For the tungsten block, the end goal is the fatigue factor-of-safety (FOS). This study documents a new structural analysis routine using software available to U.S. national laboratories (e.g. CUBIT, Sierra Multiphysics, Dakota) that enables more rapid target fatigue analysis. The increased throughput is amenable to parameter sensitivity and uncertainty quantification (UQ) studies. A set of input parameters (ultimate strength, fatigue strength, density, elastic modulus, Poisson’s ratio, thermal conductivity, coefficient of thermal expansion, specific heat, flow rate) with expected ranges are documented based on literature data, recent experimental testing, and engineering judgement. UQ bounds the resulting fatigue FOS at [0.5, 3.4] using epistemic interval analysis. These bounds are expected to be wider due to model effects (discretization) and beam effects (focus, offset) that were not included. Parameter sensitivity underscores the importance of ultimate strength and fatigue strength of irradiated tungsten on the fatigue calculations.

43 PARTICLE ACCELERATORS↗

SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection and principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.

60 APPLIED LIFE SCIENCES↗

Lipidomic Analysis of Endocannabinoid Signaling: Targeted Metabolite Identification and Quantification

The endocannabinoids N -arachidonoylethanolamide (or anandamide, AEA) and 2-arachidonoylglycerol (2-AG) belong to the larger groups of N -acylethanolamines (NAEs) and monoacylglycerol (MAG) lipid classes, respectively. They are biologically active lipid molecules that activate G-protein-coupled cannabinoid receptors found in various organisms. After AEA and 2-AG were discovered in the 1990s, they have been extensively documented to have a broad range of physiological functions. Along with AEA, several NAEs, for example, N -palmitoylethanolamine (PEA), N -stearoylethanolamine (SEA), and N -oleoylethanolamine (OEA) are also present in tissues, usually at much larger concentrations than AEA. Any perturbation that involves the endocannabinoid pathway may subsequently alter basal level or metabolism of these lipid mediators. Further, the altered levels of these molecules often reflect pathological conditions associated with tissue damage. Robust and sensitive methodologies to analyze these lipid mediators are essential to understanding how they act as endocannabinoids. The recent advances in mass spectrometry allow researchers to develop lipidomics approaches and several methodologies have been proposed to quantify endocannabinoids in various biological systems.

59 BASIC BIOLOGICAL SCIENCES↗

jialiu232/MetaFunPrimer_paper_info

Genes belonging to the same functional group may include numerous and variable gene sequences, making characterizing and quantifying difficult. Therefore, high-throughput design tools are needed to simultaneously create primers for improved quantification of target genes. We developed MetaFunPrimer, a bioinformatic pipeline, to design primers for numerous genes of interest. This tool also enables gene target prioritization based on ranking the presence of genes in user-defined references, such as environment-specific metagenomes. Given inputs of protein and nucleotide sequences for gene targets of interest and an accompanying set of reference metagenomes or genomes, MetaFunPrimer generates primers for ranked genes of interest. To demonstrate the usage and benefits of MetaFunPrimer, a total of 78 primer pairs were designed to target observed ammonia monooxygenase subunit A (amoA) genes of ammonia-oxidizing bacteria (AOB) in 1,550 publicly available soil metagenomes. We demonstrate computationally that these amoA-AOB primers can cover 94% of the amoA-AOB genes observed in the 1,550 soil metagenomes compared with a 49% estimated coverage by previously published primers. Finally, we verified the utility of these primer sets in incubation experiments that used long-term nitrogen fertilized or unfertilized soils. High-throughput quantitative PCR (qPCR) results and statistical analyses showed significant differences in relative quantification patterns between the two soils, and subsequent absolute quantifications also confirmed that target genes enumerated by six selected primer pairs were significantly more abundant in the nitrogen-fertilized soils. This new tool gives microbial ecologists a new approach to assess functional gene abundance and related microbial community dynamics quickly and affordably.

Liu, Jia↗

Motif-centric phosphoproteomics to target kinase-mediated signaling pathways

Identifying cellular phosphorylation pathways based on kinase-substrate relationships is a critical step to understanding the regulation of physiological functions in cells. Mass spectrometry-based phosphoproteomics workflows have made it possible to comprehensively collect information on individual phosphorylation sites in a variety of samples. However, there is still no generic approach to uncover phosphorylation networks based on kinase-substrate relationships in rare cell populations. Here, we describe a motif-centric phosphoproteomics approach combined with multiplexed isobaric labeling, in which in vitro kinase reactions are used to generate targeted phosphopeptides, which are spiked into one of the isobaric channels to increase detectability. Proof-of-concept experiments demonstrate selective and comprehensive quantification of targeted phosphopeptides by using multiple kinases for motif-centric channels. More than 7,000 tyrosine phosphorylation sites were quantified from several tens of micrograms of starting materials. This approach enables the quantification of multiple phosphorylation pathways under physiological or pathological regulation in a motif-centric manner.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer

Single-cell proteomics (SCP) has emerged as a powerful approach for understanding cellular heterogeneity and biological processes at unprecedented resolution. However, the extremely limited protein content of individual cells (femtogram to picogram levels) pushes current mass spectrometry instrumentation to its sensitivity limits, creating a critical analytical bottleneck. While selected reaction monitoring (SRM) using triple quadrupole (QqQ) instruments 1 offers advantages in sensitivity and reproducibility for targeted proteomics quantification, SRM still struggles with sensitivity for quantification of moderate- or low-abundance proteins from single-cell sample amounts. Here, we report the development and systematic evaluation of a dual ion funnel interface designed to address the sensitivity limitation by significantly enhancing ion transmission efficiency in commercial QqQ mass spectrometers. The dual ion funnel interface, composed of a curved S-funnel followed by a conventional ion funnel, improves ion transmission efficiency while reducing chemical noise through selective ion focusing. The performance of the dual ion funnel interface was systematically compared to standard interface on a TSQ Vantage platform across samples with different levels of complexity. The dual funnel interface demonstrated to provide up to 25-fold improvement in sensitivity across a wide range of protein concentrations in different biological matrices (low complex mouse macrophage and high complex human cells). Critically, enhanced sensitivity was accompanied by increased analytical reproducibility with lower coefficient of variations. Most importantly, the dual funnel interface enabled reliable quantification of low-abundance proteins that were barely detectable or not detected by the standard interface, extending analysis to single-cell equivalent amounts while maintaining excellent reproducibility. These results demonstrate that the dual funnel interface addresses the critical bottleneck in quantitative targeted proteomics, providing a technological foundation for ultrasensitive targeted SCP that requires both high sensitivity and robust quantitative performance.

Min, Sehong↗

Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.

Environmental Molecular Sciences Laboratory↗

Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Targeted metabolomic analysis identifies increased serum levels of GABA and branched chain amino acids in canine diabetes

Introduction Dogs with naturally occurring diabetes mellitus represent a potential model for human type 1 diabetes, yet signifcant knowledge voids exist in terms of the pathogenic mechanisms underlying the canine disorder. Untargeted metabolomic studies from a limited number of diabetic dogs identifed similarities to humans with the disease. Objective To expand and validate earlier metabolomic studies, identify metabolites that difer consistently between diabetic and healthy dogs, and address whether certain metabolites might serve as disease biomarkers. Methods Untargeted metabolomic analysis via liquid chromatography-mass spectrometry was performed on serum from diabetic (n=15) and control (n=15) dogs. Results were combined with those of our previously published studies using identical methods (12 diabetic and 12 control dogs) to identify metabolites consistently diferent between the groups in all 54 dogs. Thirty-two candidate biomarkers were quantifed using targeted metabolomics. Biomarker concentrations were compared between the groups using multiple linear regression (corrected P<0.0051 considered signifcant). Results Untargeted metabolomics identifed multiple persistent diferences in serum metabolites in diabetic dogs compared with previous studies. Therefore, targeted metabolomics showed increases in gamma amino butyric acid, valine, leucine, isoleucine, citramalate, and 2-hydroxyisobutyric acid in diabetic versus control dogs while indoxyl sulfate, N-acetyl-L-aspartic acid, kynurenine, anthranilic acid, tyrosine, glutamine, and tauroursodeoxycholic acid were decreased. Conclusion Several of these fndings parallel metabolomic studies in both human diabetes and other animal models of this disease. Given recent studies on the role of GABA and branched chain amino acids in human diabetes, the increase in serum concentrations in canine diabetes warrants further study of these metabolites as potential biomarkers, and to identify similarity in mechanisms underlying this disease in humans and dogs.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functional Enzyme-Based Approach for Linking Microbial Community Functions with Biogeochemical Process Kinetics

The kinetics of biogeochemical processes in natural and engineered environmental systems are typically described using Monod-type or modified Monod-type models. These models rely on biomass as surrogates for functional enzymes in microbial community that catalyze biogeochemical reactions. A major challenge to apply such models is the difficulty to quantitatively measure functional biomass for constraining and validating the models. On the other hand, omics-based approaches have been increasingly used to characterize microbial community structure, functions, and metabolites. Here we proposed an enzyme-based model that can incorporate omics-data to link microbial community functions with biogeochemical process kinetics. The model treats enzymes as time-variable catalysts for biogeochemical reactions and applies biogeochemical reaction network to incorporate intermediate metabolites. The sequences of genes and proteins from metagenomes, as well as those from the UniProt database, were used for targeted enzyme quantification and to provide insights into the dynamic linkage among functional genes, enzymes, and metabolites that are necessary to be incorporated in the model. The application of the model was demonstrated using denitrification as an example by comparing model-simulated with measured functional enzymes, genes, denitrification substrates and intermediates

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

TU-AB-201-11: A Novel Theoretical Framework for MRI-Only Image Guided LDR Prostate and Breast Brachytherapy Implant Dosimetry

Purpose: To propose a novel framework for accurate model-based dose calculations using only MR images for LDR prostate and breast seed implant brachytherapy. Methods: Model-based dose calculation methodologies recommended by TG-186 require further knowledge about specific tissue composition, which is challenging with MRI. However, relying on MRI-only for implant dosimetry would reduce the soft tissue delineation uncertainty, costs, and uncertainties associated with multi-modality registration and fusion processes. We propose a novel framework to address this problem using quantitative MRI acquisitions and reconstruction techniques. The framework includes three steps: (1) Identify the locations of seeds(2) Identify the presence (or absence) of calcification(s)(3) Quantify the water and fat content in the underlying tissueSteps (1) and (2) consider the sources that limit patient dosimetry, particularly the inter-seed attenuation and the calcified regions; while step (3) targets the quantification of the tissue composition to consider the heterogeneities in the medium. Our preliminary work has shown that the seeds and the calcifications can be identified with MRI using both the magnitude and the phase images. By employing susceptibility-weighted imaging with specific post-processing techniques, the phase images can be further explored to distinguish the seeds from the calcifications. Absolute quantification of tissue, water, and fat content is feasible and was previously demonstrated in phantoms and in-vivo applications, particularly for brain diseases. The approach relies on the proportionality of the MR signal to the number of protons in an image volume. By employing appropriate correction algorithms for T1 - and T2*-related biases, B1 transmit and receive field inhomogeneities, absolute water/fat content can be determined. Results: By considering calcification and interseed attenuation, and through the knowledge of water and fat mass density, accurate patient-specific implant dosimetry can be achieved with MRI-only. Conclusion: The proposed framework showed that model-based dose calculation is feasible using MRI-only state-of-the-art techniques.

60 APPLIED LIFE SCIENCES↗

PPI DataHub Project Data Package: S. elongatus PCC 7942 Circadian Control Bioproduction Metabolomics (PB-DP5)

The purpose of this experiment was to evaluate how circadian clock regulation impacts carbon partitioning between storage, growth, and product synthesis in Synechococcus elongatus PCC 7942 in providing insights to strategies for enhanced bioproduction. Culture samples were collected at 0, 0.5, 1, 2, 4, 6, and 8 hours for extracellular sucrose analysis. Circadian metabolomics data was acquired using a Agilent single quadrupole gas chromatography-mass spectrometer and processed using Agilent Mass Hunter for targeted sucrose quantification. Metabolomic analysis of PCC 7942 light-dark cycle cultures transitioned to constant light revealed distinct temporal patterns in sucrose production. Processed metabolomic datasets are openly accessible from the PNNL DataHub project dataset download page and contain secondary processed GC-MS results files and supporting metadata materials linked to relevant source code information supporting data transparency and reuse.

59 BASIC BIOLOGICAL SCIENCES↗

AUTOMATED RADIOANALYTICAL CHEMISTRY: APPLICATIONS FOR THE LABORATORY AND INDUSTRIAL PROCESS MONITORING

The identification and quantification of targeted α- and β-emitting radionuclides via destructive analysis in complex radioactive liquid matrices is highly challenging. Analyses are typically accomplished at on- or off-site laboratories through laborious sample preparation steps and extensive chemical separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, alpha energy spectroscopy, mass spectrometry). Analytical results may take days or weeks to report. When an industrial-scale plant requires periodic or continuous monitoring of radionuclides as an indication of the composition of its feed stream, diversion of safeguarded nuclides, or of plant operational conditions (for example), radiochemical measurements should be rapid, but not at the expense of precision and accuracy. Scientists at Pacific Northwest National Laboratory have developed and characterized a host of automated radioanalytical systems designed to perform reproducible and rapid radioanalytical processes. Platforms have been assembled for 1) automation and acceleration of sample analysis in the laboratory and 2) automated monitors for monitoring industrial scale nuclear processes on-line with near-real time results. These methods have been applied to the analysis of environmental-level actinides and fission products to high-level nuclear process fluids. Systems have been designed to integrate a number of discrete sample handling steps, including sample pretreatment (e.g., digestion and valence state adjustment) and chemical separations. The systems have either utilized on-line analyte detection or have collected the purified analyte fractions for off-line measurement applications. One PNNL system of particular note is a fully automated prototype on-line radioanalytical system designed for the Waste Treatment Plant at Hanford, WA, USA. This system demonstrated nearly continuous destructive analysis of the soft β-emitting radionuclide 99Tc in nuclear tank waste feed solutions. The system is compact, fully self-calibrating, and analytical results can be immediately transmitted to on- or off-site locations. This platform exemplifies how automation can be integrated into reprocessing facilities to support the needs of international nuclear safeguards and reprocessing plant operational monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum

The detection and quantification of proteins at sub-ng/mL concentrations in plasma/serum is of critical importance for candidate biomarker verification. Sensitive detection of serum proteins has typically been achieved by immunoassays; however, de novo development of antibodies is associated with high cost and long lead time. To address this challenge, we developed an antibody-free strategy, termed high-pressure high-resolution separations with intelligent selection and multiplexing (PRISM), for achieving accurate detection of proteins at ~50 pg/mL level in plasma/serum using selected reaction monitoring (SRM). This strategy is based on high resolution reversed phase liquid chromatographic separations for analyte enrichment along with intelligent selection of target fractions via on-line SRM monitoring of internal standards and fraction multiplexing prior to SRM quantification. Our work represents a major technological advance for achieving pg/mL level of serum protein quantification without specific affinity reagents and holds great promise for broad applications in biomarker verification and systems biology studies.

biomarker verification↗