Search NASA⌕ Search

SEARCH · Search NASA

Results for “techno-economic energy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Updating PV and Battery Bill Savings Calculations for Net Billing: New Best Practices for Input Data and Uncertainty

Jurisdictions are increasingly adopting compensation structures for distributed PV and PV-battery systems that price exported energy lower than energy consumed onsite (net billing rates). Standard methods for calculating the bill savings from PV and PV-battery systems were developed for net metering structures, and applying these same methods to net billing structures (such as using Typical Meteorological Year weather with actual year load) introduces bias errors that underestimate PV-battery system bill savings by between 1.5\% and 9\%, depending on the utility rate. We assess the magnitude of these errors and compare them to other sources of uncertainty when estimating the bill savings from PV and PV-battery systems under more complex utility rates.

14 SOLAR ENERGY↗

Are the U.S. Biorefineries Over the Hurdle of 2000 Ton Daily Throughput Yet?

The efficient utilization of lignocellulosic biomass for biofuel and biochemical production is hindered by material handling issues such as clogging and segregation among other challenges. Preprocessing methods such as drying, screening, and milling have improved conversion yield but have not sufficiently enhanced flowability, especially herbaceous biomass. The poor flowability of herbaceous biomass is rooted in some particle attributes that remain less altered by those methods, e.g., irregular particle shape, high roughness, and high compressibility, making it hard to scale up throughput to a key benchmark for a biorefinery – 2000 ton per day. Applying additional preprocessing methods like pelletization and torrefaction to drastically change those particle attributes can improve flow and handling but has not been comprehensively verified through test. The flowability of herbaceous biomass feedstock formats generated by three different preprocessing methods was recently assessed at Idaho National Laboratory’s Biomass Feedstock National User Facility: first, loose particles size reduced from as-received materials; second, pellets produced from an efficient densification process; and third, powders milled from torrefied pellets. Benchmarking tests including static angle of repose, basic flow energy measured in a powder rheometer, and discharge flow in an adjustable hopper, were conducted to evaluate those feedstock formats. Beyond the capacity of existing experimental apparatuses, a digital engineering approach involving flow simulations and AI models were used to identity the material attributes and processing parameters that have dominant influences on flow throughput. Techno-economic analysis focusing on hopper flow as a typical material handling operation was conducted for those feedstock formats. Perspectives will be discussed on whether the 2000-ton daily throughput for a biorefinery is achievable at an acceptable cost by using any of the tested preprocessing methods.

09 - BIOMASS FUELS↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

What Is the Best Use of Biomass? A Harmonized LCA-TEA Framework Quantifying Economic and Environmental Metrics for Bioenergy Pathways

Bioresource utilization is expected to play a pivotal role in complementing existing energy pathways and enhancing energy resilience. This study develops a harmonized life cycle assessment (LCA) and techno-economic analysis (TEA) framework to evaluate the greenhouse gas (GHG) reduction potential, minimum fuel selling price (MFSP), and marginal abatement cost (MAC) of bioenergy pathways. We analyze 19 pathways, including liquid biofuels (via catalytic fast pyrolysis, Fischer–Tropsch synthesis, and gasification), bioelectricity, and biomass-to-hydrogen, with and without carbon capture and storage (CCS). The GHG impacts are assessed using the GREET 2022 model, while U.S. Billion-Ton 2016 biomass availability projections are used to estimate scale-up potential. Additionally, we evaluate the influence of a low-carbon electricity grid on pathway performance. Our results show that CCS implementation reduces carbon intensities (CI) to net-negative values for several pathways, with MAC ranging from $\$$32 to $\$$600 per metric ton (MT) CO2e avoided. Bioelectricity pathways with CCS achieve the lowest MAC ($\$$32–$\$$68/tCO2e), while liquid biofuels and hydrogen pathways remain critical for hard-to-abate sectors like aviation and heavy industry. Pathways with net-positive electricity demand benefit from a low-carbon grid, whereas those co-producing electricity experience increased MAC under lower electricity grid CI scenarios. This open-source framework provides a robust tool for harmonized evaluation of bioenergy pathways, enabling policymakers and stakeholders to identify cost-effective strategies for biomass utilization and carbon abatement at scale. The findings underscore the importance of CCS, co-product credits, and feedstock availability in optimizing bioenergy deployment for a low-carbon economy.

09 BIOMASS FUELS↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Combined Nitrogen and Phosphorous Recovery via Electrochemical Technology Integration into Municipal Wastewater Treatment Plants

This project developed electroN-P, an electrochemical technology for recovering nitrogen and phosphorus as a fertilizer product from anaerobic digester centrate, targeting an advancement from TRL 4 to 6. The reactor was scaled 220× from a 250 mL batch cell to a continuous 4-channel system treating 55 L of wastewater, recovering >80% of phosphorus. Energy consumption under constant-voltage operation was lower than the embedded energy of conventional fertilizers, while constant-current operation produced a cost-competitive product with a smaller reactor footprint. TEA and LCA outcomes were highly sensitive to the magnesium source; alternative magnesium salt configurations projected reduced costs and embedded energy compared to sacrificial rods, but at the expense of significantly longer operation times. The recovered fertilizer performed comparably to diammonium phosphate and triple superphosphate in soil and plant trials. Integrating the technology into a whole-plant model reduced aeration energy by nearly 50%, lowering the levelized cost of water treatment from $0.668/m 3 to $0.648/m 3 . Results support targeting commercialization at smaller (≤1 MGD) facilities with high-strength digester streams. Further investigation into the transport and corrosion kinetics governing sacrificial anode wear is recommended to support continuous, longer-term operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Evaluation of Electrified Vehicle Options in Drayage Fleets

The electrification of drayage fleets offers potential economic and operational benefits, but the financial viability of electrified vehicles remains sensitive to battery cost, energy price, and fleet usage patterns. While total cost of ownership (TCO) is a useful benchmark, fleet operators and investors are equally concerned with investment performance metrics such as payback period (PB) and Internal Rate of Return (IRR), which better reflect financial risks and investment return timelines. This study develops a unified techno-economic framework that jointly evaluates TCO, PB, and IRR to determine when electrified trucks become cost-effective alternatives to diesel trucks. Building on a previously developed cost modeling tool and using real-world telematics data from a Class 8 drayage fleet at the Port of Savannah, the analysis incorporates projected battery cost trajectories, electricity and diesel price trends, vehicle efficiency improvements, and multiple battery capacities. Parameter ranges reflect widely cited projections and observed drayage-duty-cycle variability. A surrogate-modeling method approximates economic performance across thousands of battery cost–electricity price combinations, enabling high-resolution identification of conditions that achieve TCO parity, acceptable PB thresholds, and target IRR levels. Additionally, the study estimates the evolving share of the fleet that can feasibly electrify over time under multiple economic metrics. This integrated framework offers a novel, data-driven approach to inform risk-aware decision-making for fleet electrification and supports investment planning under evolving cost and operational conditions.

Sun, Ruixiao [ORNL] (ORCID:0000000341768676)↗

Charging Hub Scenario Sheet Screenshot

The Excel-based CHECT tool estimates the LCOC ($/kWh) by charger type (Level 1, Level 2, and DC fast charging) for a given charging hub scenario. CHECT requires users to input certain charging hub scenario parameters, including the number of chargers, daily utilization, and charger replacement frequency by charger type. Additional inputs such as the charging schedule, local utility rates, capital/operational costs, and financial inputs can be customized by the user, or the tool can generate results using appropriate default values from literature for the charging hub scenario and service location(s). Using the above inputs, CHECT performs a robust techno-economic analysis to generate the LCOC by charger type, broken down by cost category (e.g., capital, operational, utility, taxes) for various combinations of charging hub types (multiunit dwelling or public) and ownership models (residential, utility, or private company). It also outputs the annual discounted cash flows and determines the most sensitive input variables. In addition, the tool allows users to easily compare the LCOC across various ownership models or across different states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SimH 2 : an integrated techno-economic modeling framework for hydrogen pipeline infrastructure and network optimization

Large-scale hydrogen (H 2 ) pipeline transport design and network optimization have seldom been reported due to the lack of a cost model accounting for the relationship between transport cost and hydrogen mass flow rate. Here, this work introduced a system-level cost model for hydrogen pipeline transport at supercritical state and integrated it with an existing CO 2 pipeline network tool, SimCCS, for hydrogen-specific pipeline design and optimization. The Intermountain West (I-West) region of the U.S., historically dependent on fossil fuel-based economies, is chosen to demonstrate the capabilities of our H 2 pipeline cost model and transport network optimization platform called SimH 2 . Two scenarios are examined: one where the pipeline is not allowed to pass through disadvantaged communities and the other where it is permitted. The results highlight that incorporating disadvantaged-community constraints lead to longer pipeline routes and increased transport costs, reflecting the trade-offs involved in equitable infrastructure development. It is demonstrated that the newly developed SimH 2 tool not only enables the efficient design of H 2 transportation pipelines but also optimizes the network by accounting for local terrain and the presence of disadvantaged areas.

08 HYDROGEN↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

An Analysis of Future Wind Energy Resources and Cost Uncertainties Across the United States

Wind power is a growing source of energy generation that relies on complex global atmospheric and earth system processes. There has been evidence of reductions in average wind speeds over land in North America since the 1980s, and several models project that average wind speeds will continue to decrease. Concurrently, the cost of wind energy systems in the United States has been decreasing since around 2010, a trend also projected to continue. There is considerable uncertainty in these future projections, with quantitative estimates of future wind resource and system costs varying widely. To study this, we run wind energy models with possible future system costs, turbine designs, and meteorological inputs from multiple downscaled earth system models over the contiguous United States. Changes in mean annual energy production from 2000-2019 to 2040-2059 can be as high as +10% in South Texas or as low as -20% in Iowa. Larger turbines and moderate reductions in system costs can offset the largest projected decreases in wind resource, but much uncertainty remains in the extent to which wind resources will change and to what extent system costs can be reduced. An analysis of variance shows, in several states in the Midwest, uncertainty in future wind resources can influence the cost of wind energy nearly as much as uncertainty in future system costs.

17 WIND ENERGY↗

Heliostat Sizing Methodology for Solar Heat for Industrial Processes

This study presents a method to obtain a heliostat size that minimizes the levelized cost of a heliostat-based concentrating solar thermal system for industrial process heat (IPH) applications at operating temperatures from 565 to 1550 degrees Celsius. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWhth. Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the levelized cost of heat (LCOH), producing a characteristic U-shaped trend with a robust near-optimal window of 8 - 12 m2; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats under deployment at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

Alcoholysis of nylon 6 waste to ε-caprolactam promoted by phosphoric acid

Nylon 6 is widely used in high-performance materials. However, the inherent structural rigidity of nylon 6 inhibits catalytic depolymerization to its monomer, ε-caprolactam. Here, in this study, we demonstrate an acid-catalyzed alcoholysis process that depolymerizes nylon 6 to ε-caprolactam, achieving yields up to 74% using n-propanol as solvent and phosphoric acid as catalyst at 220°C for 2 h. We further applied the process to commercial nylon-containing products, demonstrating ε-caprolactam yields of 67% to 76%. Process modeling and techno-economic analysis estimated a minimum selling price of recycled nylon 6 at $\$$1.79/kg, 30% lower than the 5-year average market price of virgin nylon 6. These estimates depend on assumed costs and process performance and may vary with future conditions. Life cycle assessment indicated that nylon 6 produced via alcoholysis can reduce greenhouse gas emissions by up to 63% compared with primary production. Overall, this study demonstrates a facile, cost-effective, and environmentally beneficial process for nylon 6 chemical recycling.

09 BIOMASS FUELS↗

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

Model-based economic analysis under uncertainty for PFAS treatment by granular activated carbon and ion exchange technologies

Recent drinking water regulations have imposed the need for per- and polyfluoroalkyl substances (PFAS) remediation. In response, treatment facilities may be required to retrofit existing treatment schemes to treat PFAS below maximum contaminant levels (MCLs). Adsorption technologies such as granular activated carbon (GAC) and ion exchange (IX) have been demonstrated to be effective; however, there are limited techno-economic metrics available which provide guidance on technology selection and design for diverse PFAS-containing source water conditions. Process systems engineering (PSE) tools which can traditionally perform these analyses are hindered by the data availability, model validity, and understanding of treatment phenomena for emerging contaminants. This work employs published data regressions, statistical models, process models, techno-economic analyses, and other process systems tools in a model-based uncertainty framework to consider the limitations of emerging contaminant research. Through this analysis framework, economic results are provided as probabilistic distributions based on the uncertainty of the models and diverse conditions that treatment facilities experience.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗