Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of temperature changes in a cell culture plate well with absorbing walls containing a 3D model of tumour spheroid under irradiation in the optical range

The temperature conditions for photodynamic therapy of the culture of tumour cells organised in 3D spheroids are studied. The spheroids are placed in the cell culture medium in the well of a special cell culture plate with absorbing walls. A mathematical model is presented that describes the temperature distribution in a well with a cell culture plate heated by optical radiation. It is shown that the temperature in the well volume is not uniformly distributed, and the temperature on the well surface can differ significantly from the temperature in its volume. (laser medicine)

60 APPLIED LIFE SCIENCES↗

Investigation of Rapid, Moderate Temperature Change Thermal Cycles of a Micro-Tubular Flame-Assisted Fuel Cell

Despite many efforts and improvements over the last few decades, two of the major challenges facing solid oxide fuel cells (SOFCs) are slow heating rates to operating temperature (typically < 5 °C · min–1) and a limited ability to thermal cycle (<200 cycles). Recently, a novel hybrid setup that combines a fuel-rich combustion reformer with a SOFC was developed and utilized to investigate rapid heating, cooling, and thermal cycling of a micro-tubular SOFC. In this work, 3000 moderate thermal cycles are conducted at a heating rate exceeding 140 °C · min–1 and a cooling rate that exceeded 100 °C · min–1. The open-circuit voltage (OCV) was analyzed over the 150 h test, and a low degradation rate of ~0.0008 V per 100 cycles per fuel cell was observed in the absence of the current collector degradation. Unlike a previous test, which was conducted at lower temperatures, significant degradation of the current collector was observed during this test. Electrochemical impedance spectroscopy shows that degradation in the SOFC was due to increases in ohmic losses, activation losses at the cathode, and increased concentration losses.

Electrochemistry↗

Design Guidelines for Predicting Stress in Cemented Doublets Undergoing Temperature Change, Part 2

This work builds on prior work that developed a methodology for evaluating thermal stress in cemented doublets. The prior studies were limited by a paucity of actual test data, particularly from thermally tested cemented doublets. This follow-on study uses the existing methodology to estimate stresses in cemented doublets that have been tested for a temperature range from –40°C to 85°C and establishes safe stress levels using actual data. We also discuss limitations and concerns that we need to address to improve our understanding of cemented doublet failure.

36 MATERIALS SCIENCE↗

The Response of Precipitation Extremes to the Twentieth- and Twenty-First-Century Global Temperature Change in a Comprehensive Suite of CESM1 Large Ensemble Simulation: Revisiting the Role of Forcing Agents Vs. the Role of Forcing Magnitudes

The response of precipitation extremes (PEs) to global warming is found to be nonlinear in Community Earth System Model version 1 (CESM1) and other global climate models (Pendergrass et al., 2019), which led to the concern that it is not accurate to approximate the response of PE to a single forcing as the difference between simulations with all forcing agents and those that exclude one specific forcing. This calls into question previous model-based results that the sensitivity of PE with warming due to aerosol forcing is significantly larger than that due to greenhouse gases (GHGs). We reevaluate the PE sensitivity to GHGs and aerosols using available CESM1 ensemble simulations. We show that although the PE response to warming is nonlinear in CESM1, especially for the high warming projected in the twenty-first-century, PE sensitivity to aerosols is still significantly stronger than that due to GHGs when the comparison is made within similar warming regimes to avoid the bias induced by the nonlinear behavior. But the difference is smaller than previously estimated. We also conclude that the additivity assumption is largely valid to isolate the PE response due to aerosol forcing from the paired simulations including the “all forcing” experiment when the warming regime is small (e.g., 1°C–2°C in the next few decades when aerosol forcing is projected to decline and becomes a major source of uncertainty for model projection).

58 GEOSCIENCES↗

Data Mining of Polymer Phase Transitions upon Temperature Changes by Small and Wide-Angle X-ray Scattering Combined with Raman Spectroscopy

The complex physical transformations of polymers upon external thermodynamic changes are related to the molecular length of the polymer and its associated multifaceted energetic balance. The understanding of subtle transitions or multistep phase transformation requires real-time phenomenological studies using a multi-technique approach that covers several length-scales and chemical states. A combination of X-ray scattering techniques with Raman spectroscopy and Differential Scanning Calorimetry was conducted to correlate the structural changes from the conformational chain to the polymer crystal and mesoscale organization. Current research applications and the experimental combination of Raman spectroscopy with simultaneous SAXS/WAXS measurements coupled to a DSC is discussed. In particular, we show that in order to obtain the maximum benefit from simultaneously obtained high-quality data sets from different techniques, one should look beyond traditional analysis techniques and instead apply multivariate analysis. Data mining strategies can be applied to develop methods to control polymer processing in an industrial context. Crystallization studies of a PVDF blend with a fluoroelastomer, known to feature complex phase transitions, were used to validate the combined approach and further analyzed by MVA.

36 MATERIALS SCIENCE↗

Acoustic diagnostic system and method for superconducting devices operating in gas or liquid

A novel system and method for detecting a quench of a superconducting conductor and detecting abnormal behavior of a superconducting conductor using acoustic sensor technology in the coolant of a superconducting cable and/or magnet is disclosed. This system and method is not only limited to use for superconductors, but also may be used for any device disposed in liquid and gas. Acoustic sensors are installed along a coolant space of a superconducting conductor and monitor coolant conditions. By monitoring acoustic changes, temperature changes or coolant flow disruption can be detected very quickly by an acoustic sensor array. By disposition of the acoustic sensor array in a coolant flow channel, the acoustic sensor system can quickly detect a local condition, such as the thermal status (temperature) of a superconducting cable and magnet with precise spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Revisiting the Role of Ocean Circulation Changes in Polar Ocean Heat Transport Anomalies under Global Warming

In response to greenhouse gas forcing, climate models predict that poleward ocean heat transport (OHT) weakens in the Southern Ocean but increases in the Arctic. The role of ocean circulation changes in this OHT response has been evaluated by decomposing OHT anomalies into a dynamic component (holding ocean temperature fixed while circulation evolves) and a thermodynamic component (holding ocean circulation fixed while temperature evolves). However, ocean temperature changes are themselves shaped by circulation changes through redistribution of the existing heat reservoir and subsequent effects on air–sea heat fluxes. The thermodynamic component can therefore be influenced by circulation changes, making the standard thermodynamic–dynamic decomposition incomplete for isolating the role of circulation changes in OHT anomalies. To address this issue, we use a passive–active decomposition to assess the relative contributions of ocean circulation and passive ocean temperature changes to polar OHT anomalies in a fully coupled climate model. Passive temperature changes are defined as those thermally forced by the atmosphere in the absence of circulation changes. In this passive–active decomposition, an advective term involving both circulation and passive temperature changes remains ambiguous—classifying it as active implies circulation changes dominate Southern Ocean OHT anomalies, whereas classifying it as passive implies temperature changes dominate. However, both interpretations imply that ocean circulation changes have a much weaker effect on polar OHT anomalies than inferred from the standard decomposition. In conclusion, these results help reconcile conclusions from studies using the standard decomposition with those using passive tracer methods to assess the role of circulation changes in polar OHT anomalies.

Arctic↗

Temperature-driven changes in the Fermi surface of graphite

Here we report on temperature-dependent size and anisotropy of the Fermi pockets in graphite revealed by magnetotransport measurements. The magnetoresistances (MRs) obtained in fields along the c axis obey an extended Kohler's rule, with the carrier density following the prediction of a temperature-dependent Fermi energy, indicating a change in the Fermi pocket size with temperature. The angle-dependent magnetoresistivities at a given temperature exhibit a scaling behavior. The scaling factor that reflects the anisotropy of the Fermi surface is also found to vary with temperature. Our results demonstrate that temperature-driven changes in Fermi surface can be ubiquitous and need to be considered in understanding the temperature-dependent carrier density and MR anisotropy in semimetals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interpretation of Fracture Initiation Points by In-Well Low-Frequency Distributed Acoustic Sensing in Horizontal Wells

Summary Low-frequency distributed acoustic sensing (LF-DAS) exploits the optical phase shift of Rayleigh backscatter in fiber-optic cables to obtain distributed measurements of changes in strain and temperature. Fiber-optic cables are often installed for multistage hydraulic fracture diagnostics in horizontal wells. LF-DAS in an untreated well provides far-field strain measurements, while offset wells are hydraulically fractured. Such a configuration is called crosswell LF-DAS sensing. Crosswell LF-DAS measurements have proved useful in diagnosing fracture hits, fracture azimuth, planarity, cluster efficiency, fracture propagation rates, and the dynamic distance to the fracture front. In contrast, in-well LF-DAS is conducted on the actively fractured well. Due to cool fracture fluid being injected at high injection rates, the strain component of the LF-DAS response is largely obscured by temperature changes. In permanent fiber-optic cable installations, distributed temperature sensing (DTS) is often conducted simultaneously with LF-DAS. An opportunity exists to decouple the temperature and strain components of LF-DAS sensors to observe strain changes on in-well LF-DAS. The LF-DAS response is modeled as linearly dependent on strain and temperature changes. Theoretical LF-DAS temperature and strain sensitivity coefficients are derived based on the changes to the index of refraction and length of the fiber. Using the DTS measurements, temperature changes are computed, smoothed, filtered, and compared to the LF-DAS response. Crossplots of the in-well LF-DAS measurements and temperature changes from DTS measurements far from the actively fractured region are used to validate the theoretical sensitivity coefficients. Uncertainty in the temperature component of the LF-DAS response is quantified. The difficulty in corresponding the different spatial and temporal resolutions of the DTS and LF-DAS measurements is overcome by comparing the responses over a moving temporal and spatial window. If the LF-DAS response at the center of the window agrees with the DTS response within uncertainty, the measurement is filtered out. After filtering, the remaining nonzero in-well LF-DAS measurements are due to changes in strain. The data are then visualized in waterfall plots. The results indicate that the theoretical and observed strain and temperature coefficients agree within 10%. After the temperature component of the in-well LF-DAS response is extracted, the remaining nonzero measurements are located primarily within the actively treated region. Locations with peaks in the strain response are interpreted to indicate fracture initiation points. These fracture initiation points are compared with in-well DTS and high-frequency DAS noise measurements across multiple stages to better understand fracture initiation along the horizontal well.

Engineering↗

Temperature-induced changes in the synthesis gas composition in a high-temperature H 2 O and CO 2 co-electrolysis system

Solid oxide electrolysis cell (SOEC) is an attractive renewable technology capable of producing synthesis gas (H 2 + CO) from H 2 O and CO 2 . An SOEC consists of a solid oxide electrolyte and two ceramic or metal-ceramic electrodes. H 2 O and CO 2 are electrolyzed at the cathode producing H 2 and CO, releasing O 2- ions, which travel through the electrolyte to the anode side and recombine to produce pure oxygen gas as the byproduct. In the present study, a La 0.7 Sr 0.2 Ni 0.2 Fe 0.8 O 3 cathode was used to co-electrolyze H 2 O and CO 2 at three different operating temperatures- 700 °C, 750 °C and 800 °C. Synthesis gas was produced at all three operating temperatures with 100% Faradaic efficiency. The composition of the syngas, however, was found to be a function of the operating temperature. In general, the H 2 /CO ratio in the syngas decreased with increased temperature. This was partially due to CO 2 electrolysis becoming more favorable compared to H 2 O electrolysis at higher temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intraspecific Reaction Norm Variation Controls the Eco-Evolutionary Consequences of Environmental Change

As environmental change accelerates globally, understanding concurrent organismal, species, and community responses is increasingly vital. Here, we examine these collective responses by incorporating genotype-specific thermal reaction norms into an eco-evolutionary predator-prey model, allowing us to track simultaneous phenotypic, ecological, and evolutionary responses to environmental change within ecological communities. We show that the reaction norms expressed by genotypes within a population determine how a community switches between different eco-evolutionary outcomes with changes in temperature. We identify how different components of phenotypic variation in thermal reaction norms—environmental (E), additive environmental and genetic (E + G), and gene-by-environment interactions (G × E)—influence eco-evolutionary dynamics and outcomes as temperature changes. Furthermore, our findings underscore how complex eco-evolutionary responses to environmental change ultimately emerge from variation in reaction norms among genotypes, offering new mechanistic insights into environmental impacts on adaptation, the maintenance of phenotypic and genetic variation, and ecological stability, which is crucial for understanding and predicting eco-evolutionary effects of rapid environmental change in the future.

Eco-evolutionary↗

A New Scheme of Redundant Timing Crosschecking for Frontend Systems

In high energy physics experiments, frontend digitization modules are usually driven by a common clock. At the frontend electronics and digitization modules of the detector, a precise timing reference must establish in order to make a useful timing measurement. It would be very useful for the frontend digitization system to include a feature of redundant timing crosschecking. The inspiration for the timing crosschecking scheme came from the long-abandoned analog mean-timer schemes. In this scheme, several Front-end modules are connected together through a cable set with taps connected to the digitization modules. Pulses are driven from every FE modules alternately without overlapping. The arrival times of pulses sent from FE modules are digitized at the timing crosschecking module. The mean times will change as temperature changes, but their difference between two FE modules are cancelled mathematically. This feature enables easy achievement of good timing precision without the need for complex hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗