Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Orion MPCV Service Module Avionics Ring Pallet Testing, Correlation, and Analysis

The NASA Orion Multi-Purpose Crew Vehicle (MPCV) is being designed to replace the Space Shuttle as the main manned spacecraft for the agency. Based on the predicted environments in the Service Module avionics ring, an isolation system was deemed necessary to protect the avionics packages carried by the spacecraft. Impact, sinusoidal, and random vibration testing were conducted on a prototype Orion Service Module avionics pallet in March 2010 at the NASA Glenn Research Center Structural Dynamics Laboratory (SDL). The pallet design utilized wire rope isolators to reduce the vibration levels seen by the avionics packages. The current pallet design utilizes the same wire rope isolators (M6-120-10) that were tested in March 2010. In an effort to save cost and schedule, the Finite Element Models of the prototype pallet tested in March 2010 were correlated. Frequency Response Function (FRF) comparisons, mode shape and frequency were all part of the correlation process. The non-linear behavior and the modeling the wire rope isolators proved to be the most difficult part of the correlation process. The correlated models of the wire rope isolators were taken from the prototype design and integrated into the current design for future frequency response analysis and component environment specification.

Staab, Lucas↗

Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

Yager, Thomas J.↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Analytical Modeling and Test Correlation of Variable Density Multilayer Insulation for Cryogenic Storage

A unique foam/multilayer insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated using a large-scale hydrogen tank. The foam substrate insulates for ground-hold periods and enables a gaseous nitrogen purge as opposed to helium. The MLI, designed for an on-orbit storage period for 45 days, includes several unique features including a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or tank heat leak is reduced by about half in comparison with standard MLI. The focus of this effort is on analytical modeling of the variable density MLI (VD-MLI) on-orbit performance. The foam/VD-MLI model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three different MLI layer densities. The last segment is an environmental boundary or shroud that surrounds the last MLI layer. Two approaches are considered: a variable density MLI modeled layer by layer and a semiempirical model or "modified Lockheed equation." Results from the two models were very comparable and were within 5-8 percent of the measured data at the 300 K boundary condition.

Hastings, L. J.↗

Pitch Control Margin at High Angle of Attack - Quantitative Requirements (Flight Test Correlation With Simulation Predictions)

Aircraft designs that employ relaxed static stability (RSS) have the following problem: reduced pitching moments associated with RSS at high angle of attack (AOA) require a minimum pitch recovery moment or margin to guarantee a safe return from high AOA maneuvers at the most aft center of gravity (CG) encountered during a mission. Recent incidents and mishaps on Class IV aircraft have demonstrated a need for establishing quantitative longitudinal high AOA pitch control margin design guidelines for future aircraft. The Naval Air Warfare Center - Aircraft Division (NA WC-AD) is currently supporting an effort in conjunction with NASA Langley Research Center (NASA LaRC) to quantify such requirements. NASA LaRC has conducted a series of extensive simulation evaluations to define these design guidelines. The purpose of flight tests were to validate the overall research test methodology by comparing pilot comments, pilot ratings, and aircraft response characteristics gathered during inflight recoveries from high AOA conditions to those gathered during the fixed-base simulation sessions. Tests were completed on an F/A-18A in six flights for a total of 9.8 flight hours using an AOA and CG buildup sequence. Flight test results have validated the simulation studies in that pilot rating of high AOA nose-down recoveries were based on the short-term response interval in the forms of pitch acceleration and rate. In addition, flight test has demonstrated that high AOA pitch control margin can be evaluated using a stabilized pushover method.

Flight Testing↗

Detailed analysis and test correlation of a stiffened composite wing panel

Nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings supplied by the Bell Helicopter Textron Corporation, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain (ANS) elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain displacements relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis. Strain predictions from both the linear and nonlinear stress analyses are shown to compare well with experimental data up through the Design Ultimate Load (DUL) of the panel. However, due to the extreme nonlinear response of the panel, the linear analysis was not accurate at loads above the DUL. The nonlinear analysis more accurately predicted the strain at high values of applied load, and even predicted complicated nonlinear response characteristics, such as load reversals, at the observed failure load of the test panel. In order to understand the failure mechanism of the panel, buckling and first ply failure analyses were performed. The buckling load was 17 percent above the observed failure load while first ply failure analyses indicated significant material damage at and below the observed failure load.

Davis, D. Dale, Jr.↗

Squeeze Film Damper Experimental and Numerical Correlation: Test Setup Description and Parameter Identification of Dry System

The process of characterizing a damper involves both experimental techniques and model simulation. Experiments characterize dynamic behavior of a system through empirical modal analysis using impact and shaker testing. The layout of the test setup is crucial for a low-mass, nonlinear system. Physical arrangement, orientation of the system, and instrumentation affect the results that are discussed in this paper. These results can be used to validate a numerical simulation of the same system. With a validated model, important physical input parameters and modeling techniques can be determined and implemented in future designs. In other words, this modeling can be used with confidence to design alternative dampers that may be difficult, costly, and time-consuming to characterize experimentally.

Cook, Jason↗

Detailed analysis and test correlation of a stiffened composite wing panel

New finite element analysis methods are examined by application to a complicated composite wing panel from the V-22 rotorcraft. A detailed FEM model with a relatively coarse mesh of 9-node elements was generated, and linear and nonlinear stress analyses, first-ply failure analyses, and buckling analyses were conducted. At low values of applied load, i.e., up to the design ultimate load of the panel, the linear stress analysis accurately predicted the strains and structural response characteristics of the panel.

Davis, D. D., Jr.↗

An accurate nonlinear finite element analysis and test correlation of a stiffened composite wing panel

State-of-the-art nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain-displacement relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis.

Davis, D. D., Jr.↗

Correlation Tests of the Ditching Behavior of an Army B-24D Airplane and a 1/16-size Model

Behaviors of both model and full-scale airplanes were ascertained by making visual observations, by recording time histories of decelerations, and by taking motion picture records of ditchings. Results are presented in form of sequence photographs and time-history curves for attitudes, vertical and horizontal displacements, and longitudinal decelerations. Time-history curves for attitudes and horizontal and vertical displacements for model and full-scale tests were in agreement; maximum longitudinal decelerations for both ditchings did not occur at same part of run; full-scale maximum deceleration was 50 percent greater.

Jarvis, George A.↗

Test Analysis Correlation of the Single Stringer Bending Tests for the Space Shuttle ET-137 Intertank Stringer Crack Investigation

On November 5, 2010, Space Shuttle mission STS-133 was scrubbed due to a hydrogen leak at the Ground Umbilical Carrier Plate (GUCP). After the scrub, a crack in the foam thermal protection system (TPS) was observed on the External Tank (ET) near the interface between the liquid oxygen (LOX) tank and the Intertank. When the damaged foam was removed, two 9-in. long cracks were found on the feet of Intertank stringer S7-2, and the stringer failure was the cause of the TPS crack. An investigation was conducted to determine the root cause of the cracks, establish a remedy/repair for the stringers, and provide flight rationale for the damaged tank, ET-137. The Space Transportation System (STS) Super Lightweight ET (SLWT) is comprised of two propellant tanks (an aft liquid hydrogen (LH2) tank and a forward LOX tank) and an Intertank. The Intertank serves as the structural connection between the two propellant tanks and also functions to receive and distribute all thrust loads from the solid rocket boosters . The Intertank is a stiffened cylinder structure consisting of eight mechanically joined panels (two integrally-stiffened, machined thrust panels to react the booster loads and six stringer-stiffened skin panels). There are one main ring frame, four intermediate ring frames, and forward and aft flange chords that mate to the respective propellant tanks.. The skin/stringer panels utilize external hat-section stringers that are mechanically attached with rivets along most of their length and with specialty fasteners, such as GP Lockbolts and Hi-Loks, at the forward and aft ends where the stringers attach to the flange chords. During the STS-133 Intertank stringer crack investigation, cracks were found on a total of five stringers. All of the cracks were at the LOX end, in the feet of the stringers, and near the forward fasteners (GP Lockbolts). Video of tanking for the November 5 launch attempt was used to determine that the TPS failure, and thus the stringer failure, occurred as the LOX liquid level crossed the LOX tank / Intertank interface ring frame. Hence, cryogenically-induced displacements were suspected as a contributing cause of the stringer cracks. To study the behavior of Intertank stringers subjected to similar displacements, static load tests of individual stringers, colloquially known as "single stringer bending tests" were performed. Approximately thirty stringers were tested, many of which were cut from the partially completed Intertank for what would have been ET-139. In addition to the tests, finite element (FE) analyses of the test configuration were also performed. In this paper, the FE analyses and test-analysis correlation for stringer test S6-8 are presented. Stringer S6-8 is a "short chord" configuration with no doubler panels.

Phillips, Dawn R.↗