Testing function techniques in system identification
Linear time invariant differential method for testing functions in system identification and control
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Linear time invariant differential method for testing functions in system identification and control
A system for the functional testing and simulation of custom and semicustom very large scale integrated (VLSI) chips that are designed using the integrated UNIX-based computer-aided design (CAD) system is described. The testing and simulation system consists of two parts. One of these is a special purpose hardware device that is capable of controlling the digital imputs and outputs on a custom chip. This device, the Digital Microcircuit Functionality Tester (DMFT) system, can be operated by itself or in conjunction with the VAX host computer on the CAD system. The DMFT is integrated into a microprobe station so that these signals can be injected or read from nodes inside the chip, as well as at the pins. The second part of the system is a software package that is installed on the VAX. This software package, logic, includes a full-screen editor for developing chip test sequences and drivers for both the DMFT and the esim logic simulator.
This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.
Autonomic dysfunction is a feature of some neuropathies and not others. It has been suggested that some clinical and electrophysiologic attributes are predictable of autonomic impairment detected using laboratory testing; however, dear guidelines are unavailable. We evaluated 138 relatively unselected patients with peripheral neuropathy who underwent neurologic evaluation, electromyography (EMG), nerve conduction studies, and autonomic function tests to determine which variables were predictive of laboratory findings of autonomic failure. The variables evaluated were 1) clinical somatic neuropathic findings, 2) clinical autonomic symptoms, and 3) electrophysiologic findings. Autonomic symptoms were strongly predictive (Rs = 0.40, p < 0.001) of autonomic failure. Among the non-autonomic indices, absent ankle reflexes were mildly predictive (Rs = 0.19, p = 0.022) of autonomic impairment, but all others were not (duration, clinical pattern, severity, weakness, sensory loss). Electrophysiologic changes of an axonal neuropathy predicted autonomic impairment while demyelinating neuropathy did not. We conclude that autonomic studies will most likely be abnormal in patients who have symptoms of autonomic involvement and those who have an axonal neuropathy.
The Actiwatch Spectrum (AWS) is a wrist-worn device that may be used for obtaining ground or on-orbit light exposure patterns and movement data. The objective of this project was to prepare AWS devices for launch on STS-133/ULF5 by a means of implementing functional tests and engineering evaluations. The data obtained from these tests and evaluations served as a means for detecting any plausible issues that the AWS may encounter while on-orbit. Subsequent steps after detecting anomalies with AWS devices encompassed identifying their root causes and taking the steps needed to mitigate them. As a result of this study, the overall success of sleep/wake research studies for STS-133/ULF5 and future missions will be enhanced.
An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.
The modification to the methodology of profile analysis to accommodate the testing of differences between two functions with a single test, rather than multiple tests at various values of the abscissa, is described and demonstrated for two sets of simulation-performance data. The first application was to a flight-simulation comparison of pilot-vehicle performance with a three-element refractive display to performance with a more widely used beam-splitter-reflective-mirror display system. The results demonstrate that the refractive system for out-the-window scene display provides equivalent performance to the reflective system. The second application demonstrates the detection of significant differences by modified profile-analysis procedures. This application compares the effects of two sets of pitch-axis force-feel characteristics on the sink rate at touchdown performance utilizing the refractive system. This experiment demonstrates the dependence of simulator sink-rate performance on force-feel characteristics.
A recent modification of the methodology of profile analysis, which allows the testing for differences between two functions as a whole with a single test, rather than point by point with multiple tests is discussed. The modification is applied to the examination of the issue of motion/no motion conditions as shown by the lateral deviation curve as a function of engine cut speed of a piloted 737-100 simulator. The results of this application are presented along with those of more conventional statistical test procedures on the same simulator data.
Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the adaptive remodeling of the full-body gaze control systems following exposure to visual-vestibular conflict. Subjects walked on a treadmill before and after a 30- minute exposure to 0.5X minifying during which self-generated sinusoidal vertical head rotations were performed while seated. Following exposure to visual-vestibular conflict subjects showed a restriction in compensatory head movements, increased knee and ankle flexion after heel-strike and a decrease in the rate of body loading during the rapid weight transfer phase after the heel strike event. Taken together, results from both studies provide evidence that the full body contributes to gaze stabilization during locomotion, and that different functional elements are responsive to changes in visual task constraints and are subject to adaptive alterations following exposure to visual-vestibular conflict. This information provides the basis for the design of a new generation of integrative tests that incorporate the evaluation of multiple neural control systems relevant to astronaut operational performance.
Explore the source record for details and available documents.
Ionospheric transfer function (ITF) algorithms determine the effects of the ionosphere on an electromagnetic (EM) signal as it propagates through. In this report, analytic formulas are derived which can be used to compare results of ITF calculations from certain algorithms.
A FORTRAN program was instrumened to produce structural coverage measures. The structural coverage profiles of functionally generated acceptance tests and operational usage are used to examine two areas in software engineering: the examination of faults and the applicability of reliability models.
A series of operational tests was performed on the Joy longwall shearer located at the Bureau of Mines in Bructon, Pennsylvania. The purpose of these tests was to determine the transfer function and operational characteristics of the system. These characteristics will be used to generate a simulation model of the longwall shearer used in the development of the closed-loop vertical control system.
Software to evaluate functions of one or two arguments is too often tested or certified, or the accuracy assessed, by ad hoc methods. Systematic methods to test, certify or assess the accuracy of single- or double-precision functions of one or two arguments, and supporting software, are described here.
After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.
This 70‐day bed rest campaign was comprised of 6 integrated studies and conducted at the NASA Flight Analogs Research Unit (FARU). The FARU is located at the University of Texas Medical Branch, Galveston, Texas and is a satellite unit of the Institute for Translational Sciences - Clinical Research Center. This presentation will describe the FARU, discuss the utility of the bed rest platform for use in these studies, and introduce the studies that participated in the CFT 70 bed rest campaign. Information in this presentation will serve as the background for subsequent talks from each individual study. Individual study presentations will discuss preliminary results from completed subjects. Studies included in CFT70 were: Physiological Factors Contributing to Post Flight Changes in Functional Performance. J. Bloomberg, NASA Integrated Resistance and Aerobic Training Study. L. Ploutz‐Snyder, USRA Testosterone Supplementation as a Countermeasure Against Musculoskeletal losses during Space Exploration. R. Urban, University of Texas Medical Branch Effects of Retronasal Smelling, Variety and Choice on Appetite & Satiety. J. Hunter, Cornell University AD ASTRA: Automated Detection of Attitudes and States through Transaction Recordings Analysis. C. Miller, Smart Information Flow Technologies, LLC Bed Rest as a Spaceflight Analog to Study Neuro‐cognitive Changes: Extent, Longevity, and Neural Bases. R. Seidler, University of Michigan
Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.
Changes in plasma volume and protein concentration have been reported when normal subjects are bedrested or centrifuged. Since thyroid hormones are transported by specific plasma proteins, each of these procedures could be expected to change plasma levels of these hormones. In this study centrifugation of normal healthy human subjects produced an increased concentration of total protein and albumin. When these same subjects were bedrested for six days, no change in total protein, albumin or thyroxine binding globulin were found although there was an eight per cent decrease in plasma volume. Centrifugation and, to a lesser extent, bedrest produced changes in serum T-4 levels and the T-3 test results. The direction of these changes (decreased % T-3 values and increased T-4 levels) indicate that these two situations produce an increased plasma concentration of thyroxine binding sites.