Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Establishing a Ballistic Test Methodology for Documenting the Containment Capability of Small Gas Turbine Engine Compressors

A test methodology currently employed for large engines was extended to quantify the ballistic containment capability of a small turboshaft engine compressor case. The approach involved impacting the inside of a compressor case with a compressor blade. A gas gun propelled the blade into the case at energy levels representative of failed compressor blades. The test target was a full compressor case. The aft flange was rigidly attached to a test stand and the forward flange was attached to a main frame to provide accurate boundary conditions. A window machined in the case allowed the projectile to pass through and impact the case wall from the inside with the orientation, direction and speed that would occur in a blade-out event. High-peed, digital-video cameras provided accurate velocity and orientation data. Calibrated cameras and digital image correlation software generated full field displacement and strain information at the back side of the impact point.

Heady, Joel↗

Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

fatigue testing machines↗

A New Test Methodology for Evaluating Fire Risk Due to Electrical Faults in Oxygen-Enriched Environments

This paper discusses a new test methodology for assessing the safe use of materials found in spacecraft that may be exposed to electrical faults, as performed at the NASA White Sands Test Facility. “Wire-break” testing, modeled after the Cleveland Open Cup method, identifies the conditions under which pyrolyzed material transitions from a brief flash to a propagating flame. The approach focuses on fuel mass liberated through pyrolysis, mixed with oxygen, and ignited by a piloted ignition (spark due to fusion of wire) to achieve flame propagation with the least energy. The test approach attempts to find energy density thresholds derived using I²t values from current-induced heating of various test materials and wire characteristics. The application of the data provides a useful approach to mitigating fire risks in space systems by correlating threshold data to real-world designs and scaling factors, including oxygen pressure, wire diameter, heat sinking, and contained smoke volume. Several case studies, including Apollo missions and hypothetical scenarios, illustrate practical applications of these thresholds to enhance fire safety design considerations in space environments.

methodology↗

Development of test methodology for dynamic mechanical analysis instrumentation

Dynamic mechanical analysis instrumentation was used for the development of specific test methodology in the determination of engineering parameters of selected materials, esp. plastics and elastomers, over a broad range of temperature with selected environment. The methodology for routine procedures was established with specific attention given to sample geometry, sample size, and mounting techniques. The basic software of the duPont 1090 thermal analyzer was used for data reduction which simplify the theoretical interpretation. Clamps were developed which allowed 'relative' damping during the cure cycle to be measured for the fiber-glass supported resin. The correlation of fracture energy 'toughness' (or impact strength) with the low temperature (glassy) relaxation responses for a 'rubber-modified' epoxy system was negative in result because the low-temperature dispersion mode (-80 C) of the modifier coincided with that of the epoxy matrix, making quantitative comparison unrealistic.

Allen, V. R.↗

Constellation Program Flight Test Methodology and Strategy

Main projects elements: a) Orion & Ares b) New & Modified heritage hardware. c) Shuttle retirement in 2010. Methodology: a) Flight test objectives. b) Risk reduction. Strategy a) Mapping Flight Test Objectives. b) Build incremental capability.

Vigil, Art↗

Test methodology for validation of multi-frequency models of renewable energy generators using small-signal perturbations

Providing trustworthy and accurate multi-frequency (or harmonic) models for renewable energy generators (REG) is an ongoing challenge for harmonic studies. There have been effective attempts to propose and design a test device to validate the harmonic models, mainly based on shunt current perturbations. However, using additional devices for perturbations is costly for converter-based test sites. This paper provides the test specifications to extend the application of the grid emulators for voltage perturbations and appropriate harmonic model validation. Besides, the effects of the sequence couplings, initial emissions, and power set-points on the test results have been overlooked in the literature. Considering these effects, this paper proposes a generic test methodology to obtain more accurate models in the sequence domain. The experimental verification of the proposed methodology is demonstrated using a 7 MVA grid emulator for testing of a 2 MVA photo-voltaic converter and a 2 MVA Type 3 wind turbine. This way, the test challenges, specifications, and recommendations are presented using the MW-scale experiments on different REGs. Furthermore, the effects of sequence couplings and initial emissions on the calculation results are investigated and compared. The proposed methodology is applicable for harmonic model validation as well as empirical modelling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of hydrogen sensor performance are being developed. Various commercial sensor platforms (e.g., thermal conductivity, catalytic and metal semiconductor) were used to demonstrate the advantages and issues with the flow through methodology.

14 SOLAR ENERGY↗

Survival analysis of colorectal cancer patients with tumor recurrence using global score test methodology

Colorectal cancer is the third and the second most common cancer worldwide in men and women respectively, and the second in Malaysia for both genders. Surgery, chemotherapy and radiotherapy are among the options available for treatment of patients with colorectal cancer. In clinical trials, the main purpose is often to compare efficacy between experimental and control treatments. Treatment comparisons often involve several responses or endpoints, and this situation complicates the analysis. In the case of colorectal cancer, sets of responses concerned with survival times include: times from tumor removal until the first, the second and the third tumor recurrences, and time to death. For a patient, the time to recurrence is correlated to the overall survival. In this study, global score test methodology is used in combining the univariate score statistics for comparing treatments with respect to each survival endpoint into a single statistic. The data of tumor recurrence and overall survival of colorectal cancer patients are taken from a Malaysian hospital. The results are found to be similar to those computed using the established Wei, Lin and Weissfeld method. Key factors such as ethnic, gender, age and stage at diagnose are also reported.

60 APPLIED LIFE SCIENCES↗

Single event test methodology for integrated optoelectronics

A single event upset (SEU), defined as a transient or glitch on the output of a device, and its applicability to integrated optoelectronics are discussed in the context of spacecraft design and the need for more than a bit error rate viewpoint for testing and analysis. A methodology for testing integrated optoelectronic receivers and transmitters for SEUs is presented, focusing on the actual test requirements and system schemes needed for integrated optoelectronic devices. Two main causes of single event effects in the space environment, including protons and galactic cosmic rays, are considered along with ground test facilities for simulating the space environment.

Label, Kenneth A.↗

Laboratory test methodology for evaluating the effects of electromagnetic disturbances on fault-tolerant control systems

Control systems for advanced aircraft, especially those with relaxed static stability, will be critical to flight and will, therefore, have very high reliability specifications which must be met for adverse as well as nominal operating conditions. Adverse conditions can result from electromagnetic disturbances caused by lightning, high energy radio frequency transmitters, and nuclear electromagnetic pulses. Tools and techniques must be developed to verify the integrity of the control system in adverse operating conditions. The most difficult and illusive perturbations to computer based control systems caused by an electromagnetic environment (EME) are functional error modes that involve no component damage. These error modes are collectively known as upset, can occur simultaneously in all of the channels of a redundant control system, and are software dependent. A methodology is presented for performing upset tests on a multichannel control system and considerations are discussed for the design of upset tests to be conducted in the lab on fault tolerant control systems operating in a closed loop with a simulated plant.

Belcastro, Celeste M.↗

Progress Report on Modified Burst Testing and Alternative Test Methodologies

Performance of accident-tolerant fuel candidates must be assessed during the pellet-cladding mechanical interaction (PCMI) phase of a design-basis reactivity-initiated accident (RIA). Therefore, in this report, we describe Fiscal Year (FY) 2019 research activities on the development of separate-effects testing for ATF cladding candidate iron-chromium-aluminum (FeCrAl) tube specimens under loading conditions comparable to the PCMI. The first section of this report provides modified-burst test (MBT) results of unirradiated FeCrAl tubes at various pressurization-rates and an RIA-relevant temperature (275°C). The failure strain of FeCrAl was observed and calculated using a high-speed digital-image correlation (DIC) technique developed recently under the Department of Energy (DOE)’s Advanced Fuel Campaign (AFC). To overcome the complexities of performing MBT in a hot-cell environment on irradiated samples, a “plane-strain tension” (PST) test was proposed as an alternative methodology for PCMI testing. The relevance of the PST test as an alternative to MBT for irradiated specimens was explicated using the data available in the literature. The design of hot-cell compatible PST fixtures and a specific holder for PST hot-cell specimen machining were developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Life-test methodology for mechanical components

System is based on examining and testing each part of item under evaluation to determine whether aging processes, wear, or other inherent failure modes are likely to limit life to less than that required. Procedure may be applied to many long-life devices where statistical reliability analysis would be impractical.

Dufrane, K. F.↗

Development of Testing Methodologies for the Mechanical Properties of MEMS

This effort is to investigate and design testing strategies to determine the mechanical properties of MicroElectroMechanical Systems (MEMS) as well as investigate the development of a MEMS Probabilistic Design Methodology (PDM). One item of potential interest is the design of a test for the Weibull size effect in pressure membranes. The Weibull size effect is a consequence of a stochastic strength response predicted from the Weibull distribution. Confirming that MEMS strength is controlled by the Weibull distribution will enable the development of a probabilistic design methodology for MEMS - similar to the GRC developed CARES/Life program for bulk ceramics. However, the primary area of investigation will most likely be analysis and modeling of material interfaces for strength as well as developing a strategy to handle stress singularities at sharp corners, filets, and material interfaces. This will be a continuation of the previous years work. The ultimate objective of this effort is to further develop and verify the ability of the Ceramics Analysis and Reliability Evaluation of Structures Life (CARES/Life) code to predict the time-dependent reliability of MEMS structures subjected to multiple transient loads.

Ekwaro-Osire, Stephen↗

Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity

For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.

Buhler, Charles↗

Software production methodology tested project

The history and results of a 3 1/2-year study in software development methodology are reported. The findings of this study have become the basis for DSN software development guidelines and standard practices. The article discusses accomplishments, discoveries, problems, recommendations and future directions.

Tausworthe, R. C.↗