Search NASA⌕ Search

SEARCH · Search NASA

Results for “texture segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination of the myocardial ischemia.

60 APPLIED LIFE SCIENCES↗

Accurate segmentation of localized corrosion in structural alloys via deep learning

This study presents a deep learning-based approach for the automated segmentation of corrosion damage in scanning electron microscopy (SEM) images. The proposed method enables rapid and accurate segmentation of corrosion features in these SEM images, making it highly suitable for real-time applications such as automated microscopy. Specifically, a dedicated corrosion segmentation database tailored for this task is constructed. The newly constructed dataset, alongside data from two public databases, are employed to jointly train a deep learning-based model modified with a texture refinement module. Compared to the same model without the texture refinement module, the refined model substantially enhances the efficacy and efficiency of corrosion segmentation. Furthermore, the methodology developed here is extendable to segmentation tasks for other materials with similar resolution, texture, and contrast characteristics, thereby paving the way for accelerated and automated analysis in corrosion science and beyond.

Artificial Intelligence↗

SU-E-J-265: Feasibility Study of Texture Analysis for Prognosis of Local Tumor Recurrence Within 5-Years for Pharyngeal-Laryngeal Carcinoma Patients Received Radiotherapy Treatment

Purpose: Pharyngeal and laryngeal carcinomas (PLC) are among the top leading cancers in Asian populations. Typically the tumor may recur and progress in a short period of time if radiotherapy fails to deliver a successful treatment. Here we used image texture features extracted from images of computed tomography (CT) planning and conducted a retrospective study to evaluate whether texture analysis is a feasible approach to predict local tumor recurrence for PLC patients received radiotherapy treatment. Methods: CT planning images of 100 patients with PLC treated by radiotherapy at our facility between 2001 and 2010 are collected. These patients were received two separate CT scans, before and mid-course of the treatment delivery. Before the radiotherapy, a CT scanning was used for the first treatment planning. A total of 30 fractions were used in the treatment and patients were scanned with a second CT around the end of the fifteenth delivery for an adaptive treatment planning. Only patients who were treated with intensity modulated radiation therapy and RapidArc were selected. Treatment planning software of Eclipse was used. The changes of texture parameters between two CT acquisitions were computed to determine whether they were correlated to the local tumor recurrence. The following texture parameters were used in the preliminary assessment: mean, variance, standard deviation, skewness, kurtosis, energy, entropy, inverse difference moment, cluster shade, inertia, cluster prominence, gray-level co-occurrence matrix, and gray-level run-length matrix. The study was reviewed and approved by the committee of our institutional review board. Results: Our calculations suggested the following texture parameters were correlated with the local tumor recurrence: skewness, kurtosis, entropy, and inertia (p<0.0.05). Conclusion: The preliminary results were positive. However some works remain crucial to be completed, including addition of texture parameters for different image features, sensitivity of tumor segmentation variations, and effect of image filtering.

60 APPLIED LIFE SCIENCES↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

TH-E-BRF-08: Subpopulations of Similarly-Responding Lesions in Metastatic Prostate Cancer

Purpose: In patients with multiple lesions, resistance to cancer treatments and subsequent disease recurrence may be due to heterogeneity of response across lesions. This study aims to identify subpopulations of similarly-responding metastatic prostate cancer lesions in bone using quantitative PET metrics. Methods: Seven metastatic prostate cancer patients treated with AR-directed therapy received pre-treatment and mid-treatment [F-18]NaF PET/CT scans. Images were registered using an articulated CT registration algorithm and transformations were applied to PET segmentations. Midtreatment response was calculated on PET-based texture features. Hierarchical agglomerative clustering was used to form groups of similarly-responding lesions, with the number of natural clusters (K) determined by the inconsistency coefficient. Lesion clustering was performed within each patient, and for the pooled population. The cophenetic coefficient (C) quantified how well the data was clustered. The Jaccard Index (JI) assessed similarity of cluster assignments from patient clustering and from population clustering. Results: 188 lesions in seven patients were identified for analysis (between 6 to 53 lesions per patient). Lesion response was defined as percent change relative to pre-treatment for 23 uncorrelated PET-based feature identifiers. . High response heterogeneity was found across all lesions (i.e. range ΔSUVmax =−95.98% to 775.00%). For intra-patient clustering, K ranged from 1–20. Population-based clustering resulted in 75 clusters, of 1-6 lesions each. Intra-patient clustering resulted in higher quality clusters than population clustering (mean C=0.95, range=0.89 to 1.00). For all patients, cluster assignments from population clustering showed good agreement to intra-patient clustering (mean JI=0.87, range=0.68 to 1.00). Conclusion: Subpopulations of similarly-responding lesions were identified in patients with multiple metastatic lesions. Good agreement was found between population- and patient-level clustering, indicating that PET-based response features may be used to quantify disease heterogeneity in advanced metastatic disease. This method for categorizing lesion response could help in identifying lesions with similar phenotypic- or genetic-based resistances to therapy. Research Supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Constrained GAN-Generated X-Ray CT Data For Self-Supervised And Foundation-Model Segmentation Of Concrete Microstructures

Three-dimensional characterization of materials using X-ray computed tomography (XCT) is challenging due to the complexity of internal structures, noise, and variations in resolution. Traditional computer vision models often struggle to accurately segment these images, particularly in domain-specific applications like materials science. While supervised deep learning approaches have been developed to address the limitations of conventional algorithms, they typically require large amounts of labeled training data and often fail to generalize across different datasets. Self-supervised, few-and zero-shot learning methods have gained prominence in natural image processing and segmentation tasks, but their application to scientific imaging remains limited due to the unique structural complexity, noise, and textural artifacts present in materials science data. In this work, we investigate how domain adaptation, leveraging physics-based and GAN-generated synthetic data, impacts segmentation performance. We introduce a modified Contrastive Unpaired Translation (CUT) model designed to generate realistic labeled data, which can be used for training, pre-training, and fine-tuning segmentation models for real XCT microstructure data. We evaluate the performance of two segmentation approaches: a self-supervised network (SSL-ALPNet) and a foundation model (Segment Anything Model), assessing their improvements when pre-trained and/or fine-tuned on the synthesized data. Our results demonstrate that leveraging synthetic data significantly enhances segmentation performance, particularly in challenging materials science applications.

Ziabari, Amir [ORNL] (ORCID:000000034776457X)↗

SU-E-QI-17: Dependence of 3D/4D PET Quantitative Image Features On Noise

Purpose: Quantitative imaging is a fast evolving discipline where a large number of features are extracted from images; i.e., radiomics. Some features have been shown to have diagnostic, prognostic and predictive value. However, they are sensitive to acquisition and processing factors; e.g., noise. In this study noise was added to positron emission tomography (PET) images to determine how features were affected by noise. Methods: Three levels of Gaussian noise were added to 8 lung cancer patients PET images acquired in 3D mode (static) and using respiratory tracking (4D); for the latter images from one of 10 phases were used. A total of 62 features: 14 shape, 19 intensity (1stO), 18 GLCM textures (2ndO; from grey level co-occurrence matrices) and 11 RLM textures (2ndO; from run-length matrices) features were extracted from segmented tumors. Dimensions of GLCM were 256×256, calculated using 3D images with a step size of 1 voxel in 13 directions. Grey levels were binned into 256 levels for RLM and features were calculated in all 13 directions. Results: Feature variation generally increased with noise. Shape features were the most stable while RLM were the most unstable. Intensity and GLCM features performed well; the latter being more robust. The most stable 1stO features were compactness, maximum and minimum length, standard deviation, root-mean-squared, I30, V10-V90, and entropy. The most stable 2ndO features were entropy, sum-average, sum-entropy, difference-average, difference-variance, difference-entropy, information-correlation-2, short-run-emphasis, long-run-emphasis, and run-percentage. In general, features computed from images from one of the phases of 4D scans were more stable than from 3D scans. Conclusion: This study shows the need to characterize image features carefully before they are used in research and medical applications. It also shows that the performance of features, and thereby feature selection, may be assessed in part by noise analysis.

60 APPLIED LIFE SCIENCES↗

MAMA Software User Guide: Tips for Segmenting with MAMA

This document reviews the six ways to segment with the MAMA software. Mama is not a threshold based segmentation system, like many of the image analyses programs you may be have used in the past. The MAMA software is set up to allow you to segment iteratively, and do so in a variety of ways. Six different ways are show below. They can be used in almost any combination—sometimes the choice depends on the image, sometimes it depends on user preferences for what type of interactions a user is willing to do. In the examples below, by “easy”, we mean an image for which MAMA segmentation works great and little clean-up is needed. By hard image, we mean an image for which accurate segmentation is very challenging. Many metal micrographs, and particles with rough textures fall into this class.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-AB-BRA-05: Repeatability of [F-18]-NaF PET Imaging Biomarkers for Bone Lesions: A Multicenter Study

Purpose: Quantifying the repeatability of imaging biomarkers is critical for assessing therapeutic response. While therapeutic efficacy has been traditionally quantified by SUV metrics, imaging texture features have shown potential for use as quantitative biomarkers. In this study we evaluated the repeatability of quantitative {sup 18}F-NaF PET-derived SUV metrics and texture features in bone lesions from patients in a multicenter study. Methods: Twenty-nine metastatic castrate-resistant prostate cancer patients received whole-body test-retest NaF PET/CT scans from one of three harmonized imaging centers. Bone lesions of volume greater than 1.5 cm{sup 3} were identified and automatically segmented using a SUV>15 threshold. From each lesion, 55 NaF PET-derived texture features (including first-order, co-occurrence, grey-level run-length, neighbor gray-level, and neighbor gray-tone difference matrix) were extracted. The test-retest repeatability of each SUV metric and texture feature was assessed with Bland-Altman analysis. Results: A total of 315 bone lesions were evaluated. Of the traditional SUV metrics, the repeatability coefficient (RC) was 12.6 SUV for SUVmax, 2.5 SUV for SUVmean, and 4.3 cm{sup 3} for volume. Their respective intralesion coefficients of variation (COVs) were 12%, 17%, and 6%. Of the texture features, COV was lowest for entropy (0.03%) and highest for kurtosis (105%). Lesion intraclass correlation coefficient (ICC) was lowest for maximum correlation coefficient (ICC=0.848), and highest for entropy (ICC=0.985). Across imaging centers, repeatability of texture features and SUV varied. For example, across imaging centers, COV for SUVmax ranged between 11–23%. Conclusion: Many NaF PET-derived SUV metrics and texture features for bone lesions demonstrated high repeatability, such as SUVmax, entropy, and volume. Several imaging texture features demonstrated poor repeatability, such as SUVtotal and SUVstd. These results can be used to establish response criteria for NaF PET-based treatment response assessment. Prostate Cancer Foundation (PCF)

60 APPLIED LIFE SCIENCES↗

SU-E-J-245: Sensitivity of FDG PET Feature Analysis in Multi-Plane Vs. Single-Plane Extraction

Purpose: Sensitivity of PET-derived texture features to reconstruction methods has been reported for features extracted from axial planes; however, studies often utilize three dimensional techniques. This work aims to quantify the impact of multi-plane (3D) vs. single-plane (2D) feature extraction on radiomics-based analysis, including sensitivity to reconstruction parameters and potential loss of spatial information. Methods: Twenty-three patients with solid tumors underwent [{sup 18}F]FDG PET/CT scans under identical protocols. PET data were reconstructed using five sets of reconstruction parameters. Tumors were segmented using an automatic, in-house algorithm robust to reconstruction variations. 50 texture features were extracted using two Methods: 2D patches along axial planes and 3D patches. For each method, sensitivity of features to reconstruction parameters was calculated as percent difference relative to the average value across reconstructions. Correlations between feature values were compared when using 2D and 3D extraction. Results: 21/50 features showed significantly different sensitivity to reconstruction parameters when extracted in 2D vs 3D (wilcoxon α<0.05), assessed by overall range of variation, Rangevar(%). Eleven showed greater sensitivity to reconstruction in 2D extraction, primarily first-order and co-occurrence features (average Rangevar increase 83%). The remaining ten showed higher variation in 3D extraction (average Range{sub var}increase 27%), mainly co-occurence and greylevel run-length features. Correlation of feature value extracted in 2D and feature value extracted in 3D was poor (R<0.5) in 12/50 features, including eight co-occurrence features. Feature-to-feature correlations in 2D were marginally higher than 3D, ∣R∣>0.8 in 16% and 13% of all feature combinations, respectively. Larger sensitivity to reconstruction parameters were seen for inter-feature correlation in 2D(σ=6%) than 3D (σ<1%) extraction. Conclusion: Sensitivity and correlation of various texture features were shown to significantly differ between 2D and 3D extraction. Additionally, inter-feature correlations were more sensitive to reconstruction variation using single-plane extraction. This work highlights a need for standardized feature extraction/selection techniques in radiomics.

60 APPLIED LIFE SCIENCES↗

Anatomical Fraction segmentation in the biomass bales

The U.S. Department of Energy Bioenergy Technologies Office (BETO) is committed to the development of sustainable, nationwide, commercial biofuel production to displace petroleum-derived fuels, increase domestic energy production, and encourage the creation of a domestic bioenergy and bioproducts industry. Operating a commercial-scale bioenergy operation requires significant technological advancements for determining biomass feedstock quality during the preprocessing stage. Usage of non-food feedstocks- e.g., corn-stover, pine residue, and forest residue - at the biorefineries reduces strain on the food supply chain. But the non-food feedstock heterogeneity- physical size, shape, and chemical composition-poses a significant challenge during milling, conveyance, feeding, and biofuel conversion processes. 3D X-Ray imaging (CT) is capable of distinguishing material features by detecting density and compositional differences. But the inherent complexity introduced during harvesting and bailing makes the reconstruction and interpretation of baled biomass materials from x-ray data time consuming, laborious, and expensive. Feedstocks are low-density materials that produce small contrast differences in the x-ray images. This paper focuses on using the shape and texture properties, using 3D image processing techniques like 3D skeletonization, directional statistics to characterize and extract volumetric content of the different tissue samples in the biomass bales.

09 BIOMASS FUELS↗

Computer-Assisted Diagnosis System for Breast Cancer in Computed Tomography Laser Mammography (CTLM)

Computed tomography laser mammography (Eid et al. Egyp J Radiol Nucl Med, 37(1): p. 633–643, 1) is a non-invasive imaging modality for breast cancer diagnosis, which is time-consuming and challenging for the radiologist to interpret the images. Some issues have increased the missed diagnosis of radiologists in visual manner assessment in CTLM images, such as technical reasons which are related to imaging quality and human error due to the structural complexity in appearance. The purpose of this study is to develop a computer-aided diagnosis framework to enhance the performance of radiologist in the interpretation of CTLM images. The proposed CAD system contains three main stages including segmentation of volume of interest (VOI), feature extraction and classification. A 3D Fuzzy segmentation technique has been implemented to extract the VOI. The shape and texture of angiogenesis in CTLM images are significant characteristics to differentiate malignancy or benign lesions. The 3D compactness features and 3D Grey Level Co-occurrence matrix (GLCM) have been extracted from VOIs. Multilayer perceptron neural network (MLPNN) pattern recognition has developed for classification of the normal and abnormal lesion in CTLM images. The performance of the proposed CAD system has been measured with different metrics including accuracy, sensitivity, and specificity and area under receiver operative characteristics (AROC), which are 95.2, 92.4, 98.1, and 0.98%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.

60 APPLIED LIFE SCIENCES↗

Computed tomography-based texture analysis of bladder cancer: differentiating urothelial carcinoma from micropapillary carcinoma

Purpose: The purpose of the study is to determine the feasibility of using computed tomography-based texture analysis (CTTA) in differentiating between urothelial carcinomas (UC) of the bladder from micropapillary carcinomas (MPC) of the bladder. Methods: Regions of interests (ROIs) of computerized tomography (CT) images of 33 MPCs and 33 UCs were manually segmented and saved. Custom MATLAB code was used to extract voxel information corresponding to the ROI. The segmented tumors were input to a pre-existing radiomics platform with a CTTA panel. A total of 58 texture metrics were extracted using four different texture extraction techniques and statistically analyzed using a Wilcoxon rank-sum test to determine the differences between UCs and MPCs. Results: Of the 58 texture metrics extracted using the gray level co-occurrence matrix (GLCM) and gray level difference matrix (GLDM), 28 texture metrics were statistically significant (p < 0.05) for differences in tumor textures and 27 texture metrics were statistically significant (p < 0.05) for peritumoral fat textures. The remaining nine metrics extracted using histogram and fast Fourier transform analyses did not show significant differences between the textures of the tumors and their peritumoral fat. Conclusions: CTTA shows that MPC have a more heterogeneous texture compared to UC. As visual discrimination of MPC from UC from clinical CT scans are difficult, results from this study suggest that tumor heterogeneity extracted using GLCM and GLDM may be a good imaging aid in segregating MPC from UC. This tool can aid clinicians in further sub-classifying bladder cancers on routine imaging, a process which has potential to alter treatment and patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

pnnl/SAMIAm

We apply semantic boosting to the Segment Anything Model (SAM) to obtain microstructure segmentation for transmission electron microscopy. Our booster, SAM-I-Am, extracts geometric and textural features of various intermediate masks to perform mask removal and mask merging operations

Mesfin, Waqwoya↗

Nuclear Forensics Scanning

Explore the source record for details and available documents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

Prediction of spin polarized Fermi arcs in quasiparticle interference in CeBi

We predict that CeBi in the ferromagnetic state is a Weyl semimetal. Our calculations within density functional theory show the existence of two pairs of Weyl nodes on the momentum path (0,0,k z ) at 15meV above and 100meV below the Fermi level. Two corresponding Fermi arcs are obtained on surfaces of mirror-symmetric (010)-oriented slabs at E=15meV and both arcs are interrupted into three segments due to hybridization with a set of trivial surface bands. By studying the spin texture of surface states, we find the two Fermi arcs are strongly spin polarized but in opposite directions, which can be detected by spin-polarized ARPES measurements. Here, our theoretical study of quasiparticle interference (QPI) for a nonmagnetic impurity at the Bi site also reveals several features related to the Fermi arcs. Specifically, we predict that the spin polarization of the Fermi arcs leads to a bifurcation-shaped feature only in the spin-dependent QPI spectrum, serving as a fingerprint of the Weyl nodes.

36 MATERIALS SCIENCE↗