Scaling Electric Machines to a Megawatt and Material Options

Megawatt (MW) electric aircraft propulsion (EAP) is seen as a significant contributor toward achieving the goals set forth by the Sustainable Flight National Partnership. A large part of enabling MW EAP is developing specific-power-dense electric machines. As specific-power-dense electric machines are scaled up from kW to MW power levels, the thermal stresses on the machines increase in both magnitude and performance-affecting characteristics. This is particularly true for the stators of these machines. Analysis via thermal resistance network modeling and multiscale modeling reveals that increasing amounts of heat will be trapped in the stator windings as the power levels increase. The challenges this presents can be addressed through material advancements whereby materials gain multifunctionality. Specifically, the electrical insulation and potting materials, along with the electrical conductor, that compose the stator slot must work together (gain multifunctionality) to relieve the increased thermal stress. Materials research at the NASA Glenn Research Center points to some useful solutions in this trade space.

Electric Machine↗

Scaling Electric Machines to a Megawatt and Material Options

Megawatt (MW) electric aircraft propulsion (EAP) is seen as a significant contributor toward achieving the goals set forth by the Sustainable Flight National Partnership. A large part of enabling MW EAP is developing specific-power-dense electric machines. As specific-power-dense electric machines are scaled up from kW to MW power levels, the thermal stresses on the machines increase in both magnitude and performance-affecting characteristics. This is particularly true for the stators of these machines. Analysis via thermal resistance network modeling and multiscale modeling reveals that increasing amounts of heat will be trapped in the stator windings as the power levels increase. The challenges this presents can be addressed through material advancements whereby materials gain multifunctionality. Specifically, the electrical insulation and potting materials, along with the electrical conductor, that compose the stator slot must work together (gain multifunctionality) to relieve the increased thermal stress. Materials research at the NASA Glenn Research Center points to some useful solutions in this trade space.

Electric Machine↗

Apparatus and method for measuring the Seebeck coefficient and resistivity of materials

An apparatus for measuring the thermoelectric properties of materials under high pressure is described that includes a pair of force transmitting assemblies constructed of thermally and electrically conductive material positioned between the ram and anvil of a press. Each force transmitting assembly has a small diameter pressing portion for contacting a face of the sample so that the sample can be squeezed between them. Each assembly also includes a heat exchanger to maintain the sample face at a controlled temperature, and an electrical conductor to carry current generated by the sample. A sleeve of thermally and electrically insulative material closely surrounds the pressing portions of the two assemblies.

Hadek, V.↗

Perforating Thin Metal Sheets

Sheets only few mils thick bonded together, punched, then debonded. Three-step process yields perforated sheets of metal. (1): Individual sheets bonded together to form laminate. (2): laminate perforated in desired geometric pattern. (3): After baking, laminate separates into individual sheets. Developed for fabricating conductive layer on blankets that collect and remove ions; however, perforated foils have other applications - as conductive surfaces on insulating materials; stiffeners and conductors in plastic laminates; reflectors in antenna dishes; supports for thermal blankets; lightweight grille cover materials; and material for mockup of components.

Davidson, M. E.↗

Hierarchical thermal-conductive polymer nanocomposites for thermal management

Managing heat in electrical conductors is a major challenge to meet the demands for sustainable energy use and electrical reliability, most notably power electronics and energy-critical electrical machines. Achieving such disparate functionalities, such as high temperature thermal and electrical reliability, require rational design and manufacturing of thermal conductor material and its hierarchical structures. Here we present hierarchical thermal-conductive nanocomposites, consisting of nanostructured ceramic conformal coating and aligned ultrahigh molecular weight polyethylene fiber, to tailor heat dissipation in electric conductors. The hybrid aligned thermal interface exhibits a highly desirable temperature dependent anisotropic high thermal conductivity with 0.98W m –1 K –1 and dielectric strength with 3.4. In addition, electrically insulating thermal interfaces demonstrate high-performing and reliable electrical systems under the dynamic load conditions. The surface temperature of heterogeneous ceramic-polymer encapsulated conductor is 17.8 °C lower than that of polymer-encapsulated conductor at the same electrical load. Consequently, the findings shown here hold great promises for directing heat extraction in electrical machine systems, advancing thermal management for emerging electronic applications.

36 MATERIALS SCIENCE↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Power Density Cost-Effective MVDC Aircraft Cable

To make the power density of electric aircraft closer to conventional aircraft, an electric power system (EPS) with high power delivery and low system mass is necessary. As an essential component of aircraft EPS, cables are necessary to transmit power from one node to another. Virginia Tech will design high-power density, cost-effective ±5 kV cables for twin-aisle all-electric aircraft. Innovations include conductors with increased current-carrying capacity and a multilayer, multifunctional insulation system made of exceptionally high thermal conductivity materials. Designed for DC voltage, the new insulator will allow fewer partial discharge events and provide improved electromagnetic interference protection.

42 ENGINEERING↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

High-temperature electric stator

Thermal vacuum tests are conducted on high-temperature stator without a rotor. Electrical characteristics remained satisfactory during tests, insulation improved slightly, and conductor resistance remained constant. The assembly included a bore seal for hermetically sealing the stator from the rotor cavity.

Kueser, P.↗

On the mechanism of radiation and thermal-induced degradation of the insulation cables in nuclear power plants-the presence of long-lived polyenyl C-centered radicals

Radiolytically and thermally produced long-lived polyenyl C-centered radicals in the nuclear power plants’ insulation cables are detected and measured after more than 45 months of aging since the irradiation and the thermal treatment. Electron Paramagnetic Resonance (EPR) results of the irradiated Cross-linked Polyethylene (XLPE) and Ethylene Propylene Rubber (EthProRu), used as primary insulation materials at Nuclear Power Plants (NPP), clearly demonstrate the presence of polyenyl radicals along with allyl and peroxyl radicals. The yields of these free radicals are dose-rate dependent. EPR results also show the presence of the long-lived polyenyl along with allyl and peroxyl free radicals in the thermally treated XLPE, and EthProRu. These free radicals can cause a major failure in the performance of these cables in NPPs. Besides, the results showed the enhancement in the oxidation reactions due to the migration of copper ions from the conductor to the bulk of the insulation. Further, this study also shows that the oxidation index (OI) and Elongation at Break (EAB) increases and decreases respectively at higher doses and temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

Evaluating Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381) with Ultrasound

A series of experiments to investigate the use of ultrasound for measuring wire insulation have been conducted. Initial laboratory tests were performed on MIL-W-81381/7,/12, and /21 aviation wire, a wire that has polyimide (Kapton Registered Trademark) layers for insulation. Samples of this wiring were exposed to 370C temperatures for different periods of time to induce a range of thermal damage. For each exposure, 12 samples of each gauge (12, 16, and 20 gauges) were processed. The velocity of the lowest order axisymmetric ultrasonic guided mode, a mode that is sensitive to the geometry and stiffness of the wire conductor and insulation, was measured. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 +/- 78 m/s. After exposure to the high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 +/- 20 m/s after 100 hours exposure. Similar behavior was measured for the 16 gauge MIL-W-81381/21 wire and 12 gauge MIL-W-81381/12 wire which had baseline values of 3225 +/- 22 m/s and 3403 +/- 33 m/s respectively, and reached asymptotic values of 3668 +/- 19 m/s, and 3679 +/- 42 m/s respectively. These measured velocity changes represent changes of 19, 14, and 8 percent respectively for the 20, 16, and 12 gauge wires. Finally, some results for a wire with an ethylene tetrafluoroethylene insulation are reported. Qualitatively similar behaviors are noted ultrasonically.

Madaras, Eric I.↗

Chemical spray pyrolysis of Tl-Ba-Ca-Cu-O high-T(sub c) superconductors for high-field bitter magnets

The deposition of Tl-Ba-Ca-Cu-O thick films by spray pyrolyzing a Ba-Ca-Cu-O precursor film and diffusing thallium into the film to form the superconducting phase is examined. This approach was taken to reduce exposure to thallium and its health and safety hazards. The Tl-Ba-Ca-Cu-O system was selected because it has very attractive features which make it appealing to device and manufacturing engineering. Tl-Ba-Ca-Cu-O will accommodate a number of superconducting phases. This attribute makes it very forgiving to stoichiometric fluctuations in the bulk and film. It has excellent thermal and chemical stability, and appears to be relatively insensitive to chemical impurities. Oxygen is tightly bound into the systems, consequently there is no orthorhombic (conductor) to tetragonal (insulator) transition which would affect a component's lifetime. More significantly, the thallium based superconductors appear to have harder magnetic properties than the other high-Tc oxide ceramics. Estimates using magnetoresistance measurements indicate that at 77 K Tl2Ba2CaCu2O10 will have an upper critical field, H(sub c2) fo 26 Tesla for applied fields parallel to the c-axis and approximately 1000 Tesla for fields oriented in the a-b plane. Results to date have shown that superconducting films can be reproducibly deposited on 100 oriented MgO substrates. One film had a zero resistance temperature of 111.5 K. Furthermore, x ray diffraction analysis of the films showed preferential c-axis orientation parallel to the plane of the substrate. These results have now made it possible to consider the manufacture of a superconducting tape wire which can be configured into a topology useful for high-field magnet designs. The research which leads to the preparation of these films and plans for further development are reviewed.

Derochemont, L. Pierre↗

Space Shuttle Columbia Aging Wiring Failure Analysis

A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

McDaniels, Steven J.↗

Analysis of Defect Irrelevancy in a Non-Insulated REBCO Pancake Coil Using an Electric Network Model

High-temperature superconducting REBCO coated conductor is one of the main candidates for next-generation high field magnets in fusion reactors and particle accelerators owing to their high current-carrying capability. Although these materials can operate at higher temperatures and generate higher magnetic fields than their counterparts with lower critical temperatures, protecting the REBCO magnet against quench is challenging. A variety of candidate technologies that may be able to enable self-protection, including no-insulation technology and insulative coatings with temperature-dependent resistance, are in development. Here, in order to understand current sharing and thermal processes during a quench, we model a REBCO pancake coil as an electrical circuit, considering power generation and heat transfer along conductor turns, and study the current distribution around a local defect with lower critical current. The magnetic field and coil terminal voltage predicted by the simulation was compared to published experimental results. Our results provide useful insights into how current sharing occurs around defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flow separation detector

An arrangement for sensing the fluid separation along a surface which employs a thermally insulating element having a continuous surface blending into and forming a part of the fluid flow surface is described. A sudden decrease in the temperature of the downstream sensor conductor and concomitant increase in the temperature of the upstream sensor conductor is an indication of the separation. When the temperatures are returned to the state achieved during normal flow, the indicator thereby indicates the normal, attached fluid flow. The conductors may be, for example, wires or thin films, and should be within the viscous sub-layer of the expected fluid flow. A single heater and several pairs of sensors and corresponding sensor conductors may be used to detect not only the fluid flow and the separation, but the direction of the fluid flow, over the fluid flow surface.

Mateer, G. C.↗

Study of the Heater-Coil Electrical Insulation for the HL-LHC Low Beta Quadrupoles

In the framework of the HL-LHC project, the present LHC low-β superconducting quadrupoles will be substituted with higher performance Nb 3 Sn magnets (MQXF) with 11.4 T coil peak field. MQXF coils are impregnated with epoxy resin to reduce risk of stress concentration on the brittle conductor. The magnet quench protection is provided by CLIQ and quench heaters to ensure a redundant system. Quench heaters are impregnated with the coils in order to have suitable thermal contact with them, and to prevent the hot spot temperature from exceeding 350K during normal operation in case of a quench. Quench heaters are insulated from the coil by S-2 Glass and polyimide. Here, the test of the first MQXF prototype (4 m long) MQXFAP1 was stopped by a coil-to-ground short circuit triggered by a heater-to-coil short. This issue triggered a root analysis of the causes of this short. Here we prove that the use of a non-conforming cloth in coil impregnation, further weakened by non-conforming high voltage test, has triggered the shorts. Moreover, we present an analysis of the heater-to-coil insulation strength, showing the role of blistering phenomena and how they are triggered by a combination of magnet powering and heater firing.

43 PARTICLE ACCELERATORS↗