Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar Receiver with Integrated Thermal Storage for a Supercritical Carbon Dioxide Power Cycle

This project endeavors to design and demonstrate an integrated CSP system that meets the Department of Energy’s 6¢/kW-hr LCOE goal. This design is based on the 10 MW e Supercritical Transformational Electric Power (STEP) engine specifications, but adaptable to any sCO 2 power module up to 10 MW e . The enabling technology to be tested is a new class of metal hydride based thermal energy storage materials which can store thermal energy in the hydrogen bonds between the metal hydride and hydrogen. This thermochemical energy storage solution provides a much greater energy density than sensible and latent energy storage enabling an integrated system design that closely linked the metal hydride to the power block. This allows the entire system to be mounted up tower to provide cost reductions.

14 SOLAR ENERGY↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

A proposed methodology to reduce heat pump size with integrated thermal energy storage

Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.

Hirschey, Jason↗

Techno-Economic Optimization of Advanced Energy Plants with Integrated Thermal, Mechanical, and Electro-Chemical Storage (Final Report)

The increasing use of renewable energy sources is leading to increased cycling of fossil-fueled power plants (FFPP) that are designed to operate at base-loaded conditions. Integrating energy storage facilities with the FFPPs can be helpful in reducing load-following operation of FFPPs. Decentralized deployment of energy storage facilities at the FFPP level has considerable advantages due to possibilities of smaller storage capacities, immediate benefits realized by the host power plant due to the increase in the efficiency, cleaner emission and higher plant life to name a few. Most importantly, deployment at the FFPP level can exploit the existing equipment items and facilities at the host power plant, thus reducing the CAPEX and reducing the storage capacity. However, realization of these benefits will critically depend on novel configuration/integration strategies with the least impact on the power plant operation and its configuration. Furthermore, dynamics of the entire integrated system including both the FFPP and the storage technologies must be taken into account to obtain the cost-optimal solution. With these motivations, the objective of this project was to complete a focused evaluation of decentralized deployments of energy storage facilities at the FFPP level. Promising thermal, chemical, mechanical, and electro-chemical storage technologies were evaluated with due consideration of their transient response to obtain various optimal system concepts that can minimize the levelized cost of storage. For thermal storage, cryogenic energy storage along with high temperature heat storage in molten salt as well as phase change material were evaluated. For mechanical storage, cryogenic air storage and pumped hydro storages were evaluated. For chemical storage, hydrogen storage was evaluated. For electrochemical storage, the team evaluated sodium sulfur, vanadium redox flow battery as well as Li-ion batteries. Integration of these storage technologies with the natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants was considered. Six technologies, namely molten salt, cryogenics, compressed air, pumped hydro, H2 storage and Li-ion battery storage, were downselected based on their levelized cost of storage. It was observed that the ranking of the optimal storage technology can differ based on the host power plant technology even when same demand/supply/price profile for electricity are considered. It was also observed that as the variability in power demand varies, the ranking of the optimal storage technologies vary. However, for the same demand and LMP profile, top six optimal storage technologies for NGCC vs SCPC plants did not differ much even though LCOS for the same technology and optimal size of a given storage technology did differ. Detailed techno-economic assessment of these six technologies was undertaken.

01 COAL, LIGNITE, AND PEAT↗

Growth Strategy of a Hybrid Yb3Rh4Sn13/LaRuSn3 Structure Type: Integrating Thermal Analysis, In Situ Diffraction, and Geometric Descriptors

Remeika phases form a versatile family of cage like intermetallics built from transition metal–centered trigonal prisms linked into three dimensional frameworks that generate two characteristic voids: a large [AX₁₂] cuboctahedral cage hosting the rare earth ion and an [XX′₁₂] icosahedral cage accommodating the tetrel atom. In this work, we present a tool driven approach for targeted solid state synthesis of Remeika phases, integrating differential scanning calorimetry, in situ neutron diffraction, and a geometric tolerance factor that quantifies rare earth size compatibility within these polyhedral cages. When combined with arc melting and metallic flux crystal growth, this framework enables prediction, verification, and isolation of specific Remeika phases. Applying this strategy, we obtain single crystals of the predicted pseudo-perovskite Fe based Remeika compound Yb0.9FeGe3.1. More broadly, this perspective highlights how coupling real time structural probes with simple geometric descriptors provides a general pathway for designing synthesis conditions and accessing potentially metastable structure types in complex intermetallic systems.

36 MATERIALS SCIENCE↗

Performance Validation of a Thermally Integrated 50 kW High Temperature Electrolyzer System

In the proposed project, INL and OxEon seek to improve the value proposition of hydrogen production by integrating reversible fuel cell operations at relatively small scale for distributed energy applications. This goal will be accomplished by converting a 50 kW solid oxide electrolysis cell or SOEC system into a reversible system that operates at 30 kW in electrolysis mode and approximately 10 kW in fuel cell mode. The reversible SOC system will be operated for over 3,000 hours using an improved catalyst in the fuel electrode. Steam for the electrolysis will come from an electric boiler Thermal Energy Distribution System that will be configured to mimic an industrial source of low-grade heat. Thermodynamic analysis will be performed to demonstrate the potential of the system to achieve >85% system efficiency in electrolysis mode. Finally, a technoeconomic analysis will be completed to show potential to produce hydrogen at a cost of $2/kg. The figure at the right indicates a target cost breakdown to achieve that goal.

08 HYDROGEN↗

Superstructure Optimization of Waste Plastic Pyrolysis, Integrating Thermal, Catalytic, and Plasma Technologies with Machine Learning

Global plastic waste generation exceeds 430 million tonnes per year, yet fewer than 9% are recycled in the United States. Pyrolysis offers a chemical recycling route at scale, but existing techno-economic and life cycle assessments fix product yields to single pure polymers, producing economic and environmental outputs that break down when the feed composition changes. Here, we present a superstructure optimization framework that addresses this by embedding a composition-aware random forest yield predictor, trained on 566 pyrolysis experiments, within a full-scale process simulation. Product distributions update automatically as feed allocation shifts across four reactor chemistries: conventional thermal, catalytic (HZSM-5), thermal oxo-degradation, and nonequilibrium CO2 plasma. The optimal superstructure achieves minimum selling prices of −0.56 to −0.76/kg feed and global warming potentials of −0.276 to −0.322 kg CO2-eq/kg feed across four commodity price scenarios, confirming profitable, carbon-negative operation without tipping fees. Carbon abatement costs of $\$$0.46 to $\$$1.25/kg CO2-eq are competitive with direct air capture. Sensitivity analysis shows that the catalytic-plasma split fraction is the single largest driver of both economic and climate performance, while hydrocracking allocation in the wax upgrading stage is emission-neutral across the full variable range. Mixed plastic waste streams, evaluated as composition-variable feedstocks rather than pure resins, are profitable and carbon-negative across realistic market conditions. These results give a quantitative basis for reactor selection, circular economy investment, and policy design targeting chemical recycling on a large scale.

Life cycle assessment↗

Development of an autothermal formate-based hydrogen generator: From optimization of formate dehydrogenation conditions to thermal integration with Fuel Cells

Formate received significant attention for storing H2 in chemical bonds using the concept of H2 carriers. In this report, hydrogen generation from formate was optimized systematically by varying reaction variables. Initial mass activity with a turnover frequency of 3200 molH2 molPd–1 h–1 and 92% H2 yield were obtained in sodium formate (7 M 2.0 mL) dehydrogenation over Pd(3 wt %)/C at 80 °C. Influence of formate cations (Na, K, and NH4) on dehydrogenation was also elucidated, presenting that the fastest initial reaction kinetics was achieved with ammonium formate, whereas the highest H2 yield was obtained with potassium formate (PF) in multiple catalyst recycle tests. Finally, an on-site power generation system was integrated, where a proton exchange membrane fuel cell (PEMFC) was operated in conjunction with H2 produced from the custom developed semibatch dehydrogenation reactors. The system operation was demonstrated with continuous feeding of PF to generate H2 and power on demand without an external heat source by utilizing waste heat produced from the PEMFC in a highly efficient manner.

formate dehydrogenation, optimization of reaction ↗

Development of an Integrated Thermal Energy Storage Heat Exchanger for Concentrating Solar Power

In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.

14 SOLAR ENERGY↗

Thermal Integration of Advanced Nuclear Reactors with a Reference Refinery, Methanol Synthesis, and a Wood Pulp Plant (Rev.1)

The present report is intended to provide process flow diagrams (PFDs) and energy and mass balance data sheets for a U.S. industrial sector subset with which nuclear heat and power could be integrated—a subset that includes the oil refining, methanol and pulp and paper industries. Coupling options for integrating nuclear energy into these industries are quantitatively outlined for reference systems, and future work will extend this analysis in greater detail. Opportunities for integrating small modular nuclear reactors (SMNRs) were investigated for each of the industrial process configurations. Aspen HYSYS and Cycle-Tempo models for a high-temperature gas-cooled reactor were developed to evaluate the proposed integration. This introductory evaluation provides a general description and assessment of the operating principles, reactor coolant core outlet temperature, and reactor size to be integrated with industry. The industrial processes of oil refining and the production of methanol, pulp and paper were simulated by using Aspen HYSYS, Aspen Plus, and the PRELIM (Petroleum Refinery Life Cycle Inventory Model) tool to develop process details. Cycle-Tempo models then extend the process modeling results to obtain net energy demands (e.g., heat, steam, and electricity) when accounting for process steam and waste heat recovery. This information is intended to foster the analysis of integrating an SMNR to decarbonize industrial facilities. The SMNR would provide reliable, competitive, and sustainable clean energy while reducing carbon emissions and other environmental impacts, such as water withdrawals, consumption, and contamination. The refining industry, exhibited in Figure ES1, is a leading consumer of fossil -fuel-based heat, power, and hydrogen in the U.S. industrial sector, generating over 164 million metric tons (MMT) of CO 2 emissions in 2023. The overall mass and energy pertaining to a generalized complex refinery in the United States is reflected in Figure ES1, along with energy metrics regarding integration with a nuclear power plant (NPP). Data sheets were developed to indicate the energy requirements for the overall refinery and each refinery process. The data sheet for the overall refinery is shown in Table ES2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Disk-integrated Thermal Properties of Ceres Measured at Millimeter Wavelengths

We observed Ceres at three epochs in 2015 November and 2017 September and October with Atacama Large Millimeter/submillimeter Array (ALMA) 12 m array and in 2017 October with the ALMA Compact Array (ACA), all at ∼265 GHz continuum (wavelengths of ∼1.1 mm) to map the temperatures of Ceres over a full rotation at each epoch. We also used 2017 October ACA observations to search for HCN. The disk-averaged brightness temperature of Ceres is measured to be between 170 and 180 K during our 2017 observations. The rotational light curve of Ceres shows a double-peaked shape with an amplitude of about 4%. Our HCN search returns a negative result with an upper limit production rate of ∼2 × 10{sup 24} molecules s{sup −1}, assuming globally uniform production and a Haser model. A thermophysical model suggests that Ceres’s top layer has higher dielectric absorption than lunar-like materials at a wavelength of 1 mm. However, previous observations showed that the dielectric absorption of Ceres decreases toward longer wavelengths. Such distinct dielectric properties might be related to the hydrated phyllosilicate composition of Ceres and possibly abundant micrometer-sized grains on its surface. The thermal inertia of Ceres is constrained by our modeling as likely being between 40 and 160 thermal inertia units, much higher than previous measurements at infrared wavelengths. Modeling also suggests that Ceres’s light curve is likely dominated by spatial variations in its physical or compositional properties that cause changes in Ceres’s observed thermal properties and dielectric absorption as it rotates.

79 ASTRONOMY AND ASTROPHYSICS↗

Oscillating heat pipe integrated thermal management system for power electronics

Disclosed is a thermal management system for removing heat from a power electronic heat source, the system comprising: a base plate having a plurality of fluid passages there through and extending between and inlet side of the base plate and an outlet side of the base plate; and a plurality of heat transfer pipe segments respectively attached to one or more of the plurality of fluid passages at the inlet side of the base plate and the outlet side of the base plate, the plurality of heat transfer pipe segments arranged adjacent one another, the plurality of heat transfer pipe segments containing a two-phase working fluid, and the plurality of heat transfer pipe segments forming a continuous flow path through and back into the base plate for the two-phase working fluid.

Wang, Jim↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗