At least 37 records · Page 2

Transition Edge YBa_2Cu_3O_(7-x) Microbolometers for Infrared Staring Arrays

A potentially important application of high-temperature superconducting microbolometers is infrared staring arrays. In many such staring arrays, sensitivity is more important than speed of response. Thus, it is desirable to design low-thermal-mass pixels that are thermally isolated from the substrate. To this end, Johnson, et al. at Honeywell have fabricated meander lines of YBa_2Cu_3O_7(-x) (YBCO) sandwiched between layers of Si_3N_4 (SN). The silicon was etched out from under each YBCO meander line to form low-thermal-mass, thermally isolated microbolometers. These devices showed responsivities up to 60 kV/W with a 16 micro-A bias, and a noise equivalent power of 9x10^(-13) W/Hz^(1/2) at 7 Hz with a 5 micro-A bias (neglecting contact noise)...

Foote, M. C.↗

Transition Edge YBa(sub 2)Cu(sub 3)O(sub 7-x) Microbolometers for Infrared Staring Arrays

High-temperature superconducting staring arrays are potentially important for both space and terrestrial applications which require the combination of high sensitivity over a broad wavelength range and relatively high temperature operation. In many such array applications sensitivity is more important than speed of response. Thus, it is desirable to design low-thermal-mass pixels that are thermally isolated from the substrate. To this end, Johnson, et al. at Honeywell have fabricated meander lines of YBCO sandwiched between layers of silicon nitride on silicon substrates. The silicon was etched out from under each YBCO meander line to form low-thermal-mass, thermally isolated microbolometers.

infrared staring arrays↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stable Chlorine Isotopes and Elemental Chlorine by Thermal Ionization Mass Spectrometry and Ion Chromatography; Martian Meteorites, Carbonaceous Chondrites and Standard Rocks

Recently significantly large mass fractionation of stable chlorine isotopes has been reported for terrestrial and lunar samples [1,2]. In addition, in view of possible early solar system processes [3] and also potential perchlorate-related fluid/microbial activities on the Martian surface [4,5], a large chlorine isotopic fractionation might be expected for some types of planetary materials. Due to analytical difficulties of isotopic and elemental analyses, however, current chlorine analyses for planetary materials are controversial among different laboratories, particularly between IRMS (gas source mass spectrometry) and TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1,6,7] for isotopic analyses, as well as between those doing pyrohydrolysis and other groups [i.e. 6,8]. Additional careful investigations of Cl isotope and elemental abundances are required to confirm real chlorine isotope and elemental variations for planetary materials. We have developed a TIMS technique combined with HF-leaching/ion chromatography at NASA JSC that is applicable to analysis of small amounts of meteoritic and planetary materials. We present here results for several standard rocks and meteorites, including Martian meteorites.

Nakamura, N.↗

Thermal Aspects of Lithium-Ion Cells

Objective of this investigation is to provide the necessary inputs for a thermal model of the Li-ion battery for the Mars 2001 Lander. Two alternate configurations of this battery are under development: a) prismatic parallel plate, and b) cylindrical spiral wound. Required thermal inputs for both consist of the following: a) heat generation rates, b) thermal mass, and c) thermal conductivity. Thermal mass and conductivity were computed on the basis of known properties and configuration of the cell components. The heat generation rates were taken as the product of current and difference between open circuit voltage (OCV) and operating voltages (CCV) at a given state-of charge (SOC). Herein, it was assumed that the enthalpy voltage was equal to the OCV. OCV vs SOC data were obtained experimentally and CCV vs SOC were taken from previously obtained discharge data.

Frank, H.↗

Temperature Oscillations in Loop Heat Pipes - A Revisit

Three types of temperature oscillation have been observed in the loop heat pipes. The first type is an ultra-high frequency temperature oscillation with a period on the order of seconds or less. This type of temperature oscillation is of little significance in spacecraft thermal control because the amplitude is in the noise level. The second type is a high frequency, low amplitude temperature oscillation with a period on the order of seconds to minutes and an amplitude on the order of one Kelvin. It is caused by the back-and-forth movement of the vapor front near the inlet or outlet of the condenser. The third type is a low frequency, high amplitude oscillation with a period on the order of hours and an amplitude on the order of tens of Kelvin. It is caused by the modulation of the net heat load into the evaporator by the attached large thermal mass which absorbs and releases energy alternately. Several papers on LHP temperature oscillation have been published. This paper presents a further study on the underlying physical processes during the LHP temperature oscillation, with an emphasis on the third type of temperature oscillation. Specifically, equations governing the thermal and hydraulic behaviors of LHP operation will be used to describe interactions among LHP components, heat source, and heat sink. The following sequence of events and their interrelationship will also be explored: 1) maxima and minima of reservoir and thermal mass temperatures; 2) the range of the vapor front movement inside the condenser; 3) rates of change of the reservoir and thermal mass temperatures; 4) the rate of heat absorption and heat release by the thermal mass and the rate of vapor front movement; and 5) inflection points of the reservoir and thermal mass temperatures.

Fluid Mechanics and Thermodynamics↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

Apparatus Regulates Temperature Between -170 And 100 Degrees C

Temperature-control apparatus mixes pulses of liquid nitrogen into smoothly flowing nitrogen gas to produce flow of nitrogen gas at controlled low temperature. Mixing chamber provides turbulence, thermal mass, and thermal conductance to promote thermal and mechanical mixing of liquid and gaseous flows and thereby suppresses large transient deviations from set-point temperature.

Johnson, Kenneth R.↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Implementing Ordinary Differential Equation Solvers in Rust Programming Language for Modeling Vehicle Powertrain Systems: Preprint

Efficient and accurate ordinary differential equation (ODE) solvers are necessary for powertrain and vehicle dynamics modeling. However, current commercial ODE solvers can be financially prohibitive, leading to a need for accessible, effective, open-source ODE solvers designed for powertrain modeling. Rust is a compiled programming language that has the potential to be used for fast and easy-to-use powertrain models, given its exceptional computational performance, robust package ecosystem, and short time required for modelers to become proficient. However, of the three commonly used (>3,000 downloads) packages in Rust with ODE solver capabilities, only one has more than four numerical methods implemented, and none are designed specifically for modeling physical systems. Therefore, the goal of the Differential Equation System Solver (DESS) was to implement accurate ODE solvers in Rust designed for the component-based problems often seen in powertrain modeling. DESS is a text-based software package that provides a flexible framework for building and solving systems of ODEs. This allows DESS to be included as a dependency for automotive powertrain models that require a variety of solvers and solver configurations. Seven explicit ODE solver methods have been implemented in DESS: Euler’s, Heun’s, midpoint, Ralston’s, classic Runge-Kutta, Bogacki-Shampine, and Cash-Karp. These represent five fixed-step methods and two adaptive-step methods. This paper shows that the solver implementations increase accuracy and computational efficiency compared to Euler's method when modeling a system of three thermal masses in Rust. DESS also includes features designed for modeling component-based physical systems. Users can define relationships between nodes in their system, which the package then translates into a system of equations, leading to simpler and more intuitive code. In the case of a three-thermal-mass system, the user can specify node thermal properties (e.g., thermal capacitance), how nodes are interconnected, and thermal conductance between nodes rather than providing a system of equations. The core contribution from this work is an open-source, text-based Rust package with ODE solvers for automotive powertrain modeling to support cost-free, fast, and accurate simulation.

ADVANCED PROPULSION SYSTEMS↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of Uranium Ionization Efficiencies Using Zn-MOF-74 Derived Nanoporous Ion Emitters for Thermal Ionization Mass Spectrometry

The recent introduction of nano-porous ion emitters (nano-PIEs) formed from metal organic frameworks (MOFs) has demonstrated the potential to enhance sensitivity for thermal ionization mass spectrometry (TIMS). Nano-PIEs take advantage of the parent MOF’s chemical and structural tunability to form scaffolds for ion emitters. A study by Barpaga et al. 2023 on MOF-74 as the parent material found that with high volatility metals in their framework uranium sample utilization efficiency (SUE) increases by up to nine-fold (e.g., Zn-MOF-74) compared to that of the analyte on a bare filament (~0.05%). Here, in this study, we investigate the performance of Zn-MOF-74 to maximize uranium efficiencies at the trace level (= 10 -12 g) by altering the parent MOF morphology and chemistry (i.e., MOF crystal sizes and thermal degradation) and optimizing its integration with TIMS (i.e., MOF mass on a filament and ramp conditions). We observed improvement in SUE up to 20 times (≤1.0%) that of a bare filament load when nano-PIEs derived from nanocrystals of Zn-MOF-74 were heated under a specific current ramp condition. This demonstrates that rates of nano-PIE structural collapse during TIMS analysis and the subsequently formed nanomaterials (and their features) can be tuned to control analyte ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing Porous Ion Emitters for Thermal Ionization Mass Spectrometry: Evaluating Metal-Organic Frameworks

In this work we describe the first exploration of metal-organic frameworks (MOFs) as ‘next generation’ ion emitters for thermal ionization mass spectrometry (TIMS). MOFs were identified as promising candidates for this application given the synthetic control over their desired structural properties. This tunability results in well-ordered, high surface area, high porosity frameworks with targeted sorption affinities. Here we explored an aluminum-based, bipyridine-containing MOF (MOF-253) with and without incorporating the high work function metal, rhenium (Re). After analysis of a Nd-bearing MOF, we hypothesized that the well-dispersed, sponge-like interconnected network of the degraded structure would enhance Nd ionization more than traditional TIMS loading activators (i.e., phosphoric acid). Compared to filaments loaded with phosphoric acid that require an additional benzene carburization step, the Nd ionization efficiencies (atoms detected relative to atoms loaded) for heated filaments loaded with MOF-253 were similar (~1%). Electron microscopy after TIMS analysis demonstrated that the MOF was retained on the filament and, as hypothesized, preserved sub-micron porosity post analysis. While these results are preliminary, they demonstrate that MOFs have potential to enhance ionization and exceed the performance of traditional loading techniques by forming nano-porous ion emitters (nano-PIEs). Thus, further experimentation is likely to exceed this performance through more specific selection of the base MOF structure and modifications to porosity and composition. This work represents a novel application of MOFs and a next step in the pursuit of advanced thermal ionization with potential to expand across the periodic table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗