Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fundamental Needs for Dynamic and Interactive Thermal Storage Solutions for Buildings (2019 Workshop)

The 2019 Workshop on Fundamental Needs for Dynamic and Interactive Thermal Storage Solutions for Buildings was held at Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California, on November 19–20, 2019. The workshop convened 47 individuals involved in thermal, building, and materials science to present and discuss the use of thermal energy storage (TES) associated with buildings. The goals of the event were to revisit recent breakthroughs and identify future research opportunities in scientific areas.

25 ENERGY STORAGE↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Actively controlled coolant tank to increase thermal storage capacity of hybrid electric vehicles

An engine and cabin thermal management system for use with a vehicle having an engine, a cabin heating system configured to thermally heat a cabin of the vehicle, a coolant system operably coupled to the engine and to the cabin heating system to thermally manage a temperature of the engine and a temperature of the cabin. The coolant system having one or more coolant thermal storage units fluidly coupled with a radiator and heater core of the coolant system forming a coolant loop. The system further having a control system configured to monitor and maintain at least a predetermined coolant temperature at the cabin heating system even during a coolant temperature decrease at the engine stops.

Amini, Mohammad Reza↗

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

A ranking methodology for the coupling of pressurized water nuclear reactors and molten salt thermal energy storage

Thermal energy storage (TES) systems are a proposed solution to electricity market demand fluctuations and can be coupled to nuclear power plants to enable load following. Here, this work focuses on developing a methodology for evaluating potential designs for integrating a TES system into an existing pressurized water nuclear power plant. The proposed ranking methodology allows a group of experts to postulate and weigh designs based on ranking criteria derived from literature. The methodology developed in this study can aid in the final selection of a TES design for an existing nuclear power plant. The same process could be used to analyze other TES and nuclear reactor designs. The determined optimum design from this methodology was to place the TES system after the steam generator and to utilize the steam generated from the nuclear power plant to heat a molten salt TES unit. Another conclusion of this research was that human bias is prevalent during design selection, and actions such as standardized ranking criteria and large groups of experts should be used to minimize this error.

25 ENERGY STORAGE↗

Dynamic tunability of phase-change material transition temperatures using ions for thermal energy storage

Thermal energy storage (TES) based on phase-change materials (PCMs) has many current and potential applications, such as climate control in buildings, thermal management for batteries and electronics, thermal textiles, and transportation of pharmaceuticals. Despite its promise, the adoption of TES has been limited, in part due to limited tunability of the transition temperature, which hinders TES performance for varying use temperatures. Transition temperature tuning of a material using an external stimulus, such as pressure or an electric field, typically requires very large stimuli. To circumvent this problem, here, we report on the dynamic transition temperature tunability of a PCM using ions. We achieve a transition temperature tunability up to 6°C in polyethylene glycol (PEG) by using the salt lithium oxalatodifluoroborate at a low voltage of 2.5 V, which may enable simpler and safer devices/system designs. We also explain the thermal properties of the salt/PCM solution using the Flory-Huggins theory.

25 ENERGY STORAGE↗

A proposed methodology to reduce heat pump size with integrated thermal energy storage

Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.

Hirschey, Jason↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

A Novel High Energy Density Sorption-based Thermal Battery for Low-grade Thermal Energy Storage

Thermal energy storage (TES) can alleviate peak demand on the electricity grid by offsetting building thermal loads, increasing the grid’s reliability and resilience. However, low energy density and poor energy performance of existing TES technologies limit their applications. Sorption-based thermal battery (STB) system is thus developed using three-phase sorption technology to harvest low-temperature heat, store it with a much higher energy density than common TES systems and dehumidify air or provide space cooling in buildings. Although STB has been experimentally proved to be feasible, influencing factors on its performance are still unknown by far. Therefore, this paper conducted a parametric analysis on crystallization and crystal dissolution performance of a developed STB test rig. The crystallization results showed that the energy density of the STB increased with reducing the solution flow rate and the cooling water temperature. The dissolution results showed that a higher discharge rate of the STB can be achieved with increasing the flow rate and temperature of inlet diluted solution. The work in this study is helpful to the optimal design and operation of the STB system.

Wang, Lingshi↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Smart and Efficient Building Envelopes: Thermal Switches and Thermal Storage for Energy Savings and Load Flexibility

The building envelope has traditionally been seen as a static component. Much of the past thermal advancements in building envelopes has consisted of developing higher R/inch insulation. While a suitable approach for static situations, it does not consider the dynamic nature of the ambient environment or the varying needs of the electrical grid. This paper will examine three possible ways that building envelopes can be actively managed: 1. thermal switches, 2. thermal storage, and 3. the coupling of the two. Spurring innovation to make building envelopes smarter will help reduce building energy consumption and peak energy usage and contribute to flexibility in energy demand in the future.

Mumme, Sven↗

Finned-tube-integrated modular thermal storage systems for HVAC load modulation in buildings

While there is considerable focus on latent-based thermal energy storage (TES) systems, the low thermal conductivity of phase change materials (PCMs) remains a critical concern. Many approaches to enhance PCM conductivity either require complicated synthesis processes or are cost prohibitive. In this study, we investigate finned-tube modular TES systems, which are simple in design, easy to manufacture, and cost-effective due to their standard materials and components. The study includes detailed modeling and experimentation of two devices containing similar amounts of PCM but different fin spacings. The study reveals that having more fins does not necessarily increase the TES thermal performance because the reduction in the PCM volume fraction can reduce the TES volumetric and specific energy densities. We find that larger fin spacings provide a higher specific energy for lower C rates (<1C), while smaller fin spacings provide a higher specific energy for higher C rates (>1C).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ceramic encapsulated metal phase change material for high temperature thermal energy storage

Thermal energy storage (TES) is a broad-based technology for reducing CO₂ emissions and advancing concentrating solar, fossil, and nuclear power through improvements in efficiency and economics. Phase change materials (PCMs) are of interest as TES media because of their ability to store large amounts of heat in relatively small volumes. The volume expansion during a phase change, typically between a solid and liquid, can cause breakage of protective coatings. This paper reports on the fabrication of a ceramic encapsulated metal (CEM) high temperature TES technology using a rotary calcining furnace and a fluidized bed chemical vapor deposition coating technique. Aluminum beads were chosen as the PCM because Al has a high melting point (660 °C), low cost, high heat of fusion, and an ability to form a thin, strong alumina layer capable of supporting the Al melt for subsequent processing. Quite remarkably, this study shows that 1 mm diameter Al can be fluidized up to at least 1500 °C in an appropriate atmosphere while maintaining a spheroid geometry. This allowed for producing a first of a kind CEM whereby Al particles were encapsulated in pyro-carbon (PyC) and high purity, dense chemical vapor deposited SiC. The CEM with a PyC only coating was exposed to thermal cycling to test the performance with a differential scanning calorimeter; the melting point and latent heat were measured to be 648.4 ± 2.8 °C and 293.3 ± 6.2 J/g respectively. It was demonstrated that the CEM design is possible to produce, laying the foundation for manufacturing of high temperature, tunable, TES media.

25 ENERGY STORAGE↗