Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

GaN-based threshold switching device and memory diode

A switching device including a GaN substrate; an unintentionally doped GaN layer on a first surface of the GaN substrate; a regrown unintentionally doped GaN layer on the unintentionally doped GaN layer; a regrowth interface between the unintentionally doped GaN layer and the regrown unintentionally doped GaN layer; a p-GaN layer on the regrown unintentionally doped GaN layer; a first electrode on the p-GaN layer; and a second electrode on a second surface of the GaN substrate.

Fu, Kai↗

Automated Radiation Targeting in Head-and-Neck Cancer Using Region-Based Texture Analysis of PET and CT Images

Purpose: A co-registered multimodality pattern analysis segmentation system (COMPASS) was developed to automatically delineate the radiation targets in head-and-neck cancer (HNC) using both {sup 18}F-fluoro-deoxy glucose-positron emission tomography (PET) and computed tomography (CT) images. The performance of the COMPASS was compared with the results of existing threshold-based methods and radiation oncologist-drawn contours. Methods and Materials: The COMPASS extracted texture features from corresponding PET and CT voxels. Using these texture features, a decision-tree-based K-nearest-neighbor classifier labeled each voxel as either 'normal' or 'abnormal.' The COMPASS was applied to the PET/CT images of 10 HNC patients. Automated segmentation results were validated against the manual segmentations of three radiation oncologists using the volume, sensitivity, and specificity. The performance of the COMPASS was compared with three PET-based threshold methods: standard uptake value of 2.5, 50% maximal intensity, and signal/background ratio. Results: The tumor delineations of the COMPASS were both quantitatively and qualitatively more similar to those of the radiation oncologists than the delineations from the other methods. The specificity was 95% {+-} 2%, 84% {+-} 9%, 98% {+-} 3%, and 96% {+-} 4%, and the sensitivity was 90% {+-} 12%, 93% {+-} 10%, 48% {+-} 20%, and 68% {+-} 25% for the COMPASS, for a standard uptake value of 2.5, 50% maximal intensity, and signal/background ratio, respectively. The COMPASS distinguished HNC from adjacent normal tissues with high physiologic uptake and consistently defined tumors with large variability in {sup 18}F-fluoro-deoxy glucose uptake, which are often problematic with the threshold-based methods. Conclusion: Automated segmentation using texture analysis of PET/CT images has the potential to provide accurate delineation of HNC. This could lead to reduced interobserver variability, reduced uncertainty in target delineation, and improved treatment planning accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Thresholds

ADAPT is a topological analysis code that allow to compute local threshold, in particular relevance based thresholds for features defined in scalar fields. The initial target application is vortex detection but the software is more generally applicable to all threshold based feature definitions.

Bremer, P. -T.↗

Prediction of the energetic particle redistribution by an improved critical gradient model and analysis of the transport threshold

Based on the theory of critical gradient model (CGM) and following the simulation method proposed by Waltz et al., a combination of TGLFEP and EPtran code is employed to predict the energetic particle (EP) transport induced by Alfvén eigenmodes (AEs). To be consistent with the experiment, recent improvements to the simulation method include consideration of threshold evolution and orbit loss due to finite orbit width. The revised CGM is applied to simulate two DIII-D experimental discharges (#142111 and #153071). It well reproduces the experimental profiles with multiple unstable AEs and large-scale EP transport. Discharge #142111 had previously been simulated using a nonlinear MHD-kinetic code MEGA with a transport mechanism based on stochasticity induced by overlapping AE. By comparing the simulated EP profiles, we find that the AE transport threshold is approximated by both the MEGA nonlinear stability threshold and the proposed CGM threshold (error <5% for single n and <17% for multiple n simulation). Both of them are larger than the linear stability threshold of the most unstable AE mode by a quantity of the order of the flux needed to sustain EP transport by the background turbulence. Additionally, we have also applied the improved CGM to simulate the α particle redistribution for a China Fusion Engineering Test Reactor steady state scenario. Because of the clear separation between the AE unstable region and the loss cone, only a moderate α particle loss of ~9.6% is predicted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gains From Real-Time Tracking of Prostate Motion During External Beam Radiation Therapy

Purpose: To study the gains from real-time tracking of prostate motion and threshold-based intervention and the feasibility of margin reduction for external beam radiation therapy of prostate cancer. Methods and Materials: Prostate intrafractional motion data from 775 randomly selected treatment fractions (105 prostate patients) were analyzed. Statistical distributions of prostate intrafractional displacement from baseline were used for treatment margin calculation together with other geometrical uncertainties for all patients and a subset of 7 patient who exhibited the largest intrafractional motion. Compared with treatment without any intrafractional intervention, potential reductions in treatment margins were evaluated for treatments with 5-mm and 3-mm threshold-based intervention and four-dimensional (4D) treatments with and without prostate rotation correction. Results: The percentage of time of prostate displacement from the baseline by 3 mm and 5 mm in any direction was 13.4% and 1.8%, respectively, for the general patient population. The ratios were 41% and 15% for the 7 selected patients. Reductions in the posterior margin were 0.2, 0.5, 1.3, and 3.1 mm from the original 7.7 mm, respectively, for 5-mm and 3-mm threshold-based treatments and 4D treatments with and without prostate rotation correction for all patients. They were 1.3, 1.9, 3.1 and 4.9 mm from the original 9.5 mm, corresponding to the 7 selected patients. The treatment margin reductions in other directions were even smaller. Conclusions: Real-time motion tracking and threshold-based intrafractional intervention may play a significant roll in treatment margin reduction for a small fraction of patients but not for the general patient population. Four-dimensional treatments with prostate rotation correction can reduce the treatment margin more significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Information From Prior Satellite Scans to Improve Cloud Detection Near the Day-Night Terminator

With geostationary satellite data it is possible to have a continuous record of diurnal cycles of cloud properties for a large portion of the globe. Daytime cloud property retrieval algorithms are typically superior to nighttime algorithms because daytime methods utilize measurements of reflected solar radiation. However, reflected solar radiation is difficult to accurately model for high solar zenith angles where the amount of incident radiation is small. Clear and cloudy scenes can exhibit very small differences in reflected radiation and threshold-based cloud detection methods have more difficulty setting the proper thresholds for accurate cloud detection. Because top-of-atmosphere radiances are typically more accurately modeled outside the terminator region, information from previous scans can help guide cloud detection near the terminator. This paper presents an algorithm that uses cloud fraction and clear and cloudy infrared brightness temperatures from previous satellite scan times to improve the performance of a threshold-based cloud mask near the terminator. Comparisons of daytime, nighttime, and terminator cloud fraction derived from Geostationary Operational Environmental Satellite (GOES) radiance measurements show that the algorithm greatly reduces the number of false cloud detections and smoothes the transition from the daytime to the nighttime clod detection algorithm. Comparisons with the Geoscience Laser Altimeter System (GLAS) data show that using this algorithm decreases the number of false detections by approximately 20 percentage points.

Yost, Christopher R.↗

Assessment of integral models for non-Boussinesq lazy plumes using numerical simulations

Integral modelling of turbulent buoyant plumes is crucial for rapid predictions of plume characteristics. While the governing equations are typically derived using self-similarity and a Boussinesq approximation, these assumptions may not hold for plumes originating from finite-area sources with large density ratios. Here, this work evaluates the accuracy of integral-scale models for non-Boussinesq lazy plumes using high-fidelity numerical simulations of turbulent helium plumes. We analyse the plume kinematics by computing vertical fluxes, plume radius and radial profiles, establishing some disparities between common practice and physical accuracy. We identify how the definition of the plume radius changes the perception of the plume structure when the flow is not self-similar and derive a relationship between the flux-based and threshold-based definitions without requiring self-similarity. We then examine the plume dynamics by evaluating the source terms from the governing plume equations. Our results support neglecting diffusive and viscous effects but emphasise the importance of the mean pressure gradient, even in the self-similar regime. Two coefficients need to be modelled: the well-known entrainment coefficient and the lesser-known momentum correction coefficient, which is a correction required for the momentum equation to account for self-similar and slender approximations. The momentum correction coefficient is found to be approximately constant and slightly greater than the assumed value of 1. The standard entrainment coefficient models perform well up to a local Richardson number three times the asymptotic value but overpredict entrainment for larger Richardson numbers. We propose a correction using the known finite limit of entrainment at infinite Richardson number.

Meehan, Michael Alexander [Sandia National Laborat↗

Autonomous Correction of Sensor Data Applied to Building Technologies Utilizing Statistical Processing Methods

Autonomous detection and correction of potentially missing or corrupt sensor data is a essential concern in building technologies since data availability and correctness is necessary to develop accurate software models for instrumented experiments. Therefore, this paper aims to address this problem by using statistical processing methods including: (1) least squares; (2) maximum likelihood estimation; (3) segmentation averaging; and (4) threshold based techniques. Application of these validation schemes are applied to a subset of data collected from Oak Ridge National Laboratory s (ORNL) ZEBRAlliance research project, which is comprised of four single-family homes in Oak Ridge, TN outfitted with a total of 1,218 sensors. The focus of this paper is on three different types of sensor data: (1) temperature; (2) humidity; and (3) energy consumption. Simulations illustrate the threshold based statistical processing method performed best in predicting temperature, humidity, and energy data.

building technologies.↗

SU-F-J-32: Do We Need KV Imaging During CBCT Based Patient Set-Up for Lung Radiation Therapy?

Purpose: To evaluate the role of 2D kilovoltage (kV) imaging to complement cone beam CT (CBCT) imaging in a shift threshold based image guided radiation therapy (IGRT) strategy for conventional lung radiotherapy. Methods: A retrospective study was conducted by analyzing IGRT couch shift trends for 15 patients that received lung radiation therapy to evaluate the benefit of performing orthogonal kV imaging prior to CBCT imaging. Herein, a shift threshold based IGRT protocol was applied, which would mandate additional CBCT verification if the applied patient shifts exceeded 3 mm to avoid intraobserver variability in CBCT registration and to confirm table shifts. For each patient, two IGRT strategies: kV + CBCT and CBCT alone, were compared and the recorded patient shifts were categorized into whether additional CBCT acquisition would have been mandated or not. The effectiveness of either strategy was gauged by the likelihood of needing additional CBCT imaging for accurate patient set-up. Results: The use of CBCT alone was 6 times more likely to require an additional CBCT than KV+CBCT, for a 3 mm shift threshold (88% vs 14%). The likelihood of additional CBCT verification generally increased with lower shift thresholds, and was significantly lower when kV+CBCT was used (7% with 5 mm shift threshold, 36% with 2 mm threshold), than with CBCT alone (61% with 5 mm shift threshold, 97% with 2 mm threshold). With CBCT alone, treatment time increased by 2.2 min and dose increased by 1.9 cGy per fraction on average due to additional CBCT with a 3mm shift threshold. Conclusion: The benefit of kV imaging to screen for gross misalignments led to more accurate CBCT based patient localization compared with using CBCT alone. The subsequently reduced need for additional CBCT verification will minimize treatment time and result in less overall patient imaging dose.

60 APPLIED LIFE SCIENCES↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Current-induced electrical self-oscillations across out-of-plane threshold switches based on VO{sub 2} layers integrated in crossbars geometry

Electrically activated metal-insulator transition (MIT) in vanadium dioxide (VO{sub 2}) is widely studied from both fundamental and practical points of view. It can give valuable insights on the currently controversial phase transition mechanism in this material and, at the same time, allows the development of original MIT-based electronic devices. Electrically triggered insulator-metal transitions are demonstrated in novel out-of-plane, metal-oxide-metal type devices integrating a VO{sub 2} thin film, upon applying moderate threshold voltages. It is shown that the current-voltage characteristics of such devices present clear negative differential resistance effects supporting the onset of continuous, current-driven phase oscillations across the vanadium dioxide material. The frequencies of these self-sustained oscillations are ranging from 90 to 300 kHz and they may be tuned by adjusting the injected current. A phenomenological model of the device and its command circuit is developed, and allows to extract the analytical expressions of the oscillation frequencies and to simulate the electrical oscillatory phenomena developed across the VO{sub 2} material. Such out-of-plane devices may further contribute to the general understanding of the driving mechanism in metal-insulator transition materials and devices, a prerequisite to promising applications in high speed/high frequency networks of oscillatory or resistive memories circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections

Purpose: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. Methods: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Results: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). Conclusions: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

60 APPLIED LIFE SCIENCES↗

FN-DFE: Fuzzy-Neural Data Fusion Engine for Enhanced State-Awareness of Resilient Hybrid Energy System

Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFE is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer

Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRI intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose measurement based on threshold shift in MOSFET arrays in commercial SRAMS

A new method using an array of MOS transistors isdescribed for measuring dose absorbed from ionizingradiation. Using the array of MOSFETs in a SRAM, a direct measurement of the number of MOS cells which change as a function of applied bias on the SRAM. Since the input and output of a SRAM used as a dosimeter is completely digital, the measurement of dose is easily accessible by a remote processing system.

SRAM dosimetry microdosimetry threshold shift↗