Search NASA⌕ Search

SEARCH · Search NASA

Results for “timekeeping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Homeostasis in Primates in the Hyperdynamic Environment

The influence of chronic centrifugation upon the homestatic regulation of the circadian timekeeping system was examined. The interactions of body temperature regulation and the behavioral state of arousal were studied by evaluating the influence of cephalic fluid shifts induced by lower body positive air pressure (LBPP), upon these systems. The small diurnal squirrel monkey (Saimiri sciureus) was used as the non-human primate model. Results show that the circadian timekeeping system of these primates is functional in the hyperdynamic environment, however, some of its components appear to be regulated at different homeostatic levels. The LBPP resulted in an approximate 0.7 C decrease in DBT (p 0.01). However, although on video some animals appeared drowsy during LBPP, sleep recording revealed no significant changes in state of arousal. Thus, the physiological mechanisms underlying this lowering of body temperature can be independent of the arousal state.

Fuller, C. A.↗

Laser clocks and near field gravity of rotating objects

This work explores the feasibliity of using high performance laser clocks to detect effects of rotation in the near field region of the Earth's gravitational field. According to general relativity, the time recorded by an independent clock is the proper time of the space-time metric that applies to the system under consideration. If the gravitational source is stationary (nonrotating), proper time involves only the speed of the clocks and the scalar gravitational potential at the position of the clocks. However, if the source is rotating, the motion of the source could have an effect on the metric. Previous attempts to calculate the relativistic timekeeping for terrestrial clocks have used the metric for a nonrotating system, primarily because metrics for a rotating system were not available. This work investigates the specific effects of rotation on the Earth's gravitational field and the corresponding effect on timekeeping of laser clocks in the near field environment.

Hafele, Joseph C.↗

Time Distribution Using SpaceWire in the SCaN Testbed on ISS

A paper describes an approach for timekeeping and time transfer among the devices on the CoNNeCT project s SCaN Testbed. It also describes how the clocks may be synchronized with an external time reference; e.g., time tags from the International Space Station (ISS) or RF signals received by a radio (TDRSS time service or GPS). All the units have some sort of counter that is fed by an oscillator at some convenient frequency. The basic problem in timekeeping is relating the counter value to some external time standard such as UTC. With SpaceWire, there are two approaches possible: one is to just use SpaceWire to send a message, and use an external wire for the sync signal. This is much the same as with the RS- 232 messages and l pps line from a GPS receiver. However, SpaceWire has an additional capability that was added to make it easier - it can insert and receive a special "timecode" word in the data stream.

Lux, James P.↗

Extraordinary frequency stabilization by resonant nonlinear mode coupling

Here, we show that a self-sustained oscillator with a frequency-selective element operating with two nonlinearly coupled modes can achieve a level of frequency stability well beyond that available using single-mode operation. The system of interest consists of a self-sustained oscillator based on a nonlinear primary mode that is coupled via an internal resonance to a passive secondary mode. Analysis of a generic model for this resonance with both additive and multiplicative noises reveals that the stability improvements accrue from two sources: (i) nonlinear frequency veering in the primary mode, a classical analogue to quantum-level repulsion, that eliminates amplitude-to-frequency noise conversion; and (ii) phase cleaning of the oscillator through an intrinsic phase constraint arising from synchronization of the modes. This latter effect can significantly reduce the effects of intrinsic frequency fluctuations of the primary mode, which are not accessible by any known strategy using single-mode operation. The theoretical predictions are supported by experimental measurements of a microelectromechanical systems-based oscillator that demonstrate a reduction in oscillator line width of several orders of magnitude. This approach offers a means of optimizing frequency stability in self-sustained oscillators, which has direct implications for applications in timekeeping and sensing.

36 MATERIALS SCIENCE↗

Mitigating the Effects of Au-Al Intermetallic Compounds Due to High-Temperature Processing of Surface-Electrode Ion Traps

Stringent physical requirements need to be met for the high-performing surface-electrode ion traps used in quantum computing and timekeeping. In particular, these traps must survive a high-temperature environment for vacuum chamber preparation and support high RF voltage on closely spaced electrodes. Due to the use of gold wire bonds on aluminum pads, intermetallic growth can lead to wire bond failure via breakage or high resistance, limiting the lifetime of a trap assembly to a single multiday bake at 200 ° C. Using traditional thick metal stacks to prevent intermetallic growth, however, can result in trap failure due to RF breakdown events. Through high-temperature experiments, we conclude that an ideal metal stack for ion traps is Ti/Pt/Au (20/100/250 nm), which allows for a cumulative bakeable time of roughly 86 days without compromising the trap voltage performance. This increase in the bakeable lifetime of ion traps will remove the need to discard otherwise functional ion traps when vacuum hardware is upgraded, which will greatly benefit ion trap experiments.

Haltli, Raymond A.↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

Utilization of FSK communications for time

The method of time control at a radio station for time signal transmission using frequency shift keying, is discussed. Methods for extracting a recovered clock at the receiver are described. Results of a test involving the methods of processing time signals are presented. The requirements for adapting Precise Time and Time Interval control to a communications system are analyzed. A method for reducing the time required for synchronization or identification of messages and the fallout from the communication system to passive timekeeping users are reported.

Stone, R. R., Jr.↗

Precise time and time interval (PTTI), an overview

Present applications of precise time and frequency (T/F) technology can be grouped as follows: (1) Communications systems which require T/F for time division multiplexing and for using spread spectrum techniques. (2) Navigation systems which need T/F for position fixing using a timed signal. (3) Scientific-Metrological applications which use T/F as the most precisely reproducible standard of measurement. (4) Astronomical-Space applications which cover a variety of the most demanding applications such as pulsar research, Very Long Baseline Interferometry (VLBI) and laser/radar ranging. In particular, pulsar time-of-arrival measurements require submicrosecond precision over a period of one-half year referred to an extraterrestrial inertial system, and constitute the most stringent requirements for uniform timekeeping to date.

Winkler, G. M. R.↗

Time measurement techniques

The common time measurements as used by the U.S. Air Force Measurements and Standards Laboratory, Aerospace Guidance and Metrology Center (AGMC), Newark Air Force Station, Ohio, are described. Electronic counter time interval measurements are emphasized since this is the most common time comparison measurement in use. The proper use and setting of controls will be covered along with helpful hints and common mistakes to be avoided. Applications of time measurements are described and some of these are timekeeping via Loran-C, TV Line-10, and WWV. Frequency determination using periodic time readings will also be discussed.

Barnaba, J. F.↗

Relativistic effects of the rotation of the earth on remote clock synchronization

A treatment is given of relativistic clock synchronization effects due to the rotation of the earth. Unlike other approaches, the point of view of an earth fixed coordinate system is used which offers insight to many problems. An attempt is made to give the reader an intuitive grasp of the subject as well as to provide formulae for his use. Specific applications to global timekeeping, navigation, VLBI, relativistic clock experiments, and satellite clock synchronization are discussed. The question of whether atomic clocks are ideal clocks is also treated.

Reinhardt, V.↗

Navigation between the planets

Recent advances in spacecraft tracking, chronometry, ephemerides, and orbit and trajectory determinations are reviewed. Improvements in timekeeping are reviewed, as well as precision distance and range measurements; orbit determinations, trajectory-correction maneuvers, flight path optimization, and information provided by rotation of the tracking station with the earth's surface. Doppler and tropospheric wave propagation effects are dealt with. Nongravitational perturbations (solar radiation pressure, release of gases from the spacecraft, stochastic unmodeled accelerations and sequential estimation to cope with them), the effect of the target planet's gravitational field upon close approach, and navigation problems in the outer reaches of the solar system (TV data telemetered back for inertial navigation) are covered. By-products of the research include: refined data on the mass of planets, on planetary mass distributions, planet configurations, on physical properties of the atmospheres and ionospheres of planets, and opportunities for refined tests of gravitation and relativity theories and models.

Melbourne, W. G.↗

Time estimation as a secondary task to measure workload: Summary of research

Actively produced intervals of time were found to increase in length and variability, whereas retrospectively produced intervals decreased in length although they also increased in variability with the addition of a variety of flight-related tasks. If pilots counted aloud while making a production, however, the impact of concurrent activity was minimized, at least for the moderately demanding primary tasks that were selected. The effects of feedback on estimation accuracy and consistency were greatly enhanced if a counting or tapping production technique was used. This compares with the minimal effect that feedback had when no overt timekeeping technique was used. Actively made verbal estimates of sessions filled with different activities performed during the interval were increased. Retrospectively made verbal estimates, however, increased in length as the amount and complexity of activities performed during the interval were increased.

Hart, S. G.↗

Application of satellite time transfer in autonomous spacecraft clocks

The conceptual design of a spacecraft clock that will provide a standard time scale for experimenters in future spacecraft., and can be sychronized to a time scale without the need for additional calibration and validation is described. The time distribution to the users is handled through onboard computers, without human intervention for extended periods. A group parallel binary code, under consideration for onboard use, is discussed. Each group in the code can easily be truncated. The autonomously operated clock not only achieves simpler procedures and shorter lead times for data processing, but also contributes to spacecraft autonomy for onboard navigation and data packetization. The clock can be used to control the sensor in a spacecraft, compare another time signal such as that from the global positioning system, and, if the cost is not a consideration, can be used on the ground in remote sites for timekeeping and control.

Chi, A. R.↗

Interplanetary plasma concentration measurements by use of dual frequencies from separated sites

In the interplanetary plasma studies considered, signals at two frequencies are sent simultaneously from a single site on the earth to a spacecraft, or vice versa. Changes in group and phase velocity are proportional to the number density of the plasma and inversely proportional to the square of the signal frequency. Plasma-induced radio timing changes can be measured through comparisons of the changes at widely different frequencies. Such a system has, however, certain weaknesses, which can be overcome by making use of an approach which uses separated sites for sources of the low and high frequencies. The practical advantages gained by site separation are balanced somewhat by several technical problems, but each problem can be solved. The main barrier appears to be a very exacting timekeeping requirement. These requirements can be satisfied with the aid of the cesium clock.

Croft, T. A.↗

Satellite-tracking and Earth dynamics research programs

The Arequipa station obtained a total of 31,989 quick-look range observations on 719 passes in the six months. Data were acquired from Metsahovi, San Fernando, Kootwijk, Wettzell, Grasse, Simosato, Graz, Dodaira and Herstmonceux. Work progressed on the setup of SAO 1. Discussions were also initiated with the Israelis on the relocation of SAO-3 to a site in southern Israel in FY-1984. Arequipa and the cooperating stations continued to track LAGEOS at highest priority for polar motion and Earth rotation studies, and for other geophysical investigations, including crustal dynamics, earth and ocean tides, and the general development of precision orbit determination. SAO completed the revisions to its field software as a part of its recent upgrading program. With cesium standards Omega receivers, and other timekeeping aids, the station was able to maintain a timing accuracy of better than plus or minus 6 to 8 microseconds.

Source record↗

Neurospora circadian rhythms in space - A reexamination of the endogenous-exogenous question

To test the functioning of circadian rhythms removed from periodicities of the earth's 24-hour rotation, the conidiation rhythm of the fungus Neurospora crassa was monitored in constant darkness during spaceflight. The free-running period of the rhythm was the same in space as on the earth, but there was a marked reduction in the clarity of the rhythm, and apparent arrhythmicity in some tubes. At the current stage of analysis of the results there is insufficient evidence to determine whether the effect seen in space was related to removal from 24-hour periodicities and whether the circadian timekeeping mechanism, or merely its expression, was affected.

Sulzman, F. M.↗

Performance data of US Naval Observatory VLG-11 hydrogen masers since September, 1983

In 1983, two VLC-11 masers were delivered to the U.S. Naval Observatory by the Smithsonian Astrophysical Observatory. Last year the short-term stability of these masers was reported and the effect of this short-term stability on timekeeping performance was examined. Since the date of installation, 13 September 1983, data on the masers' long-term performance have been accumulated. The Allan variance, agma(tau), of the relative frequency between the masers reaches a minimum of about 4 parts in 10 to the 16th power at averaging times 5,000 seconds and rises at longer averaging times due, at least partly, to systematic frequency drift. The systematic frequency drifts, expressed in units of fractional frequency difference per day are discussed.

Vessot, R. F. C.↗