Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Verification Testing For Solid-Element Material Models 11-19 in DYNA3D/ParaDyn

This technical report documents the creation and implementation of verification tests for solid-element material models 11 through 19 available in DYNA3D/ParaDyn. The verification tests covered all aspects of each material model, except for the Weibull distribution functionality in material models 15 and 19. General test cases were created to verify the elastic and plastic behavior of the material models. Other additional tests were developed to examine the intricacies of each material model. Each test involved the use a kinematic load case and specification of material parameters necessary to activate corresponding features of the material model. The load cases prescribed the full time history of the kinematic motion for the solid elements, and these loads are independent of the material model or element formulation. When possible, closed form solutions were then derived for each verification test in a continuum setting. The DYNA3D simulations for each test were carried out over a unit time interval, t ϵ [0, 1], and the as implemented DYNA3D response was compared to the closed form solutions evaluated at discrete points in time. A relative error measure was determined for each test to justify the proper implementation of the material model. The relative errors comparing the DYNA3D solution to the analytical solution were, in general, on the order of machine precision except where noted. This signifies the proper implementation of solid-element material models 11-19. In the development of these verification tests, six bugs were found and fixed in the source code. Additionally, this work generated eighteen DYNA3D input decks and answer extraction scripts in the DYNA3D/ParaDyn Software Quality Assurance test suite, which are comprised of a total of 285 solid-element tests. Testing for each material model utilizes two input decks and answer extraction scripts, where one focuses on the linear elastic response and the other examines the inelastic and remaining functionalities of the material model. In total, this work added 285 individual verification test problems in the DYNA3D/ParaDyn test suite.

42 ENGINEERING↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

Toward Higher-order Accuracy in Self-gravitating Hydrodynamics

High-order algorithms have emerged in numerical astrophysics as a promising avenue to reduce truncation error (proportional to a power of the linear resolution Δ x ) with only a moderate increase to computational expense. Significant effort has been placed in the development of finite-volume algorithms for (magneto)hydrodynamics; however, state-of-the-art astrophysical simulations tightly couple a plenitude of physics, additionally including gravity, photon transport, cosmic-ray transport, chemistry, and/or diffusion, to name a few. Algorithms frequently operator-split this additional physics (often a first-order error in time) and/or adopt a model wherein their evaluation is limited to second-order accuracy in space. In this work, we present a fourth-order-accurate finite-volume scheme for self-gravitating hydrodynamics on a uniform Cartesian grid. The method supplies source terms for the gravitational acceleration ( ρ g ) and gravitational energy release ( ρ v · g ) associated with fourth-order-accurate solutions to the Poisson equation. Our scheme (1) guarantees the conservation of total linear momentum while (2) decreasing (in proportion to Δ x 4 ) the effects of spurious heating and/or cooling associated with truncation error in the gravity. We demonstrate expected convergence rates for the algorithm by measuring errors in test problems evolving self-gravity modified linear waves and 3D polytropic equilibria. We test robustness of the algorithm by integrating an induced “inside-out” adiabatic collapse. We also discuss a method to smoothly downgrade the solution to second-order spatial accuracy to avoid spurious overshoots near steep density and/or pressure gradients.

79 ASTRONOMY AND ASTROPHYSICS↗

Shortening Delivery Times of Intensity Modulated Proton Therapy by Reducing Proton Energy Layers During Treatment Plan Optimization

Purpose: To shorten delivery times of intensity modulated proton therapy by reducing the number of energy layers in the treatment plan. Methods and Materials: We have developed an energy layer reduction method, which was implemented into our in-house-developed multicriteria treatment planning system “Erasmus-iCycle.” The method consisted of 2 components: (1) minimizing the logarithm of the total spot weight per energy layer; and (2) iteratively excluding low-weighted energy layers. The method was benchmarked by comparing a robust “time-efficient plan” (with energy layer reduction) with a robust “standard clinical plan” (without energy layer reduction) for 5 oropharyngeal cases and 5 prostate cases. Both plans of each patient had equal robust plan quality, because the worst-case dose parameters of the standard clinical plan were used as dose constraints for the time-efficient plan. Worst-case robust optimization was performed, accounting for setup errors of 3 mm and range errors of 3% + 1 mm. We evaluated the number of energy layers and the expected delivery time per fraction, assuming 30 seconds per beam direction, 10 ms per spot, and 400 Giga-protons per minute. The energy switching time was varied from 0.1 to 5 seconds. Results: The number of energy layers was on average reduced by 45% (range, 30%-56%) for the oropharyngeal cases and by 28% (range, 25%-32%) for the prostate cases. When assuming 1, 2, or 5 seconds energy switching time, the average delivery time was shortened from 3.9 to 3.0 minutes (25%), 6.0 to 4.2 minutes (32%), or 12.3 to 7.7 minutes (38%) for the oropharyngeal cases, and from 3.4 to 2.9 minutes (16%), 5.2 to 4.2 minutes (20%), or 10.6 to 8.0 minutes (24%) for the prostate cases. Conclusions: Delivery times of intensity modulated proton therapy can be reduced substantially without compromising robust plan quality. Shorter delivery times are likely to reduce treatment uncertainties and costs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Objective and Efficient Method for Assessing the Impact of Reduced-Precision Calculations On Solution Correctness

Recent studies have shown that reducing the precision of floating-point calculations in an atmospheric model can improve the models' computational performance without affecting model fidelity, but code changes are needed to accommodate lower precision, and a small number of calculations might need to retain higher precision to prevent undue round-off error. For complex and computationally expensive systems like the Energy Exascale Earth System Model (E3SM), a method is needed to objectively assess the quality of the lower-precision simulations and to quickly identify problematic code pieces This paper demonstrates that solution correctness can be evaluated through a simple and quantitative error metric based on time step convergence. The proposed test method can unambiguously detect the accumulation of precision error and objectively assess its impact on solution accuracy. Since fast physical processes are known to affect key features of the multi-year mean climate in an atmospheric model, we show that the convergence test applied to short simulations can provide useful information about the impact of reduced precision on a model’s long-term behavior. In contrast, the traditional way of climate model evaluation requires multi-year simulations and involves inspecting many physical quantities for statistical significance in the presence of natural variability. The simplicity, computational efficiency, and objectivity of the proposed method makes it very attractive for high-resolution model development. The method is also expected to be applicable to other models that numerically solve time evolution equations.

97 MATHEMATICS AND COMPUTING↗

Towards efficient backward-in-time adjoint computations using data compression techniques

In the context of a posteriori error estimation for nonlinear time-dependent partial differential equations, the state-of-the-practice is to use adjoint approaches which require the solution of a backward-in-time problem defined by a linearization of the forward problem. One of the major obstacles in the practical application of these approaches, we found, is the need to store, or recompute, the forward solution to define the adjoint problem and to evaluate the error representation. Our study considers the use of data compression techniques to approximate forward solutions employed in the backward-in-time integration. The development derives an error representation that accounts for the difference between the standard-approach and the compressed approximation of the forward solution. This representation is algorithmically similar to the standard representation and only requires the computation of the quantity of interest for the forward solution and the data-compressed reconstructed solution (i.e. scalar quantities that can be evaluated as the forward problem is integrated). This approach is then compared with existing techniques, such as checkpointing and time-averaged adjoints. Lastly, we provide numerical results indicating the potential efficiency of our approach on a transient diffusion–reaction equation and on the Navier–Stokes equations. These results demonstrate memory compression ratios up to 450×450× while maintaining reasonable accuracy in the error-estimates.

42 ENGINEERING↗

Application of a four-step HMX kinetic model to an impact-induced fraction ignition problems

There has been a long history of interest in the decomposition kinetics of HMX and HMX-based formulations due to the widespread use of this explosive in high performance systems. The kinetics allow us to predict, or attempt to predict, the behavior of the explosive when subjected to thermal hazard scenarios that lead to ignition via impact, spark, friction or external heat. The latter, commonly referred to as 'cook off', has been widely studied and contemporary kinetic and transport models accurately predict time and location of ignition for simple geometries. However, there has been relatively little attention given to the problem of localized ignition that results from the first three ignition sources of impact, spark and friction. The use of a zero-order single-rate expression describing the exothermic decomposition of explosives dates to the early work of Frank-Kamanetskii in the late 1930s and continued through the 60's and 70's. This expression provides very general qualitative insight, but cannot provide accurate spatial or timing details of slow cook off ignition. In the 70s, Catalano, et al., noted that single step kinetics would not accurately predict time to ignition in the one-dimensional time to explosion apparatus (ODTX). In the early 80s, Tarver and McGuire published their well-known three step kinetic expression that included an endothermic decomposition step. This scheme significantly improved the accuracy of ignition time prediction for the ODTX. However, the Tarver/McGuire model could not produce the internal temperature profiles observed in the small-scale radial experiments nor could it accurately predict the location of ignition. Those factors are suspected to significantly affect the post-ignition behavior and better models were needed. Brill, et al. noted that the enthalpy change due to the beta-delta crystal phase transition was similar to the assumed endothermic decomposition step in the Tarver/McGuire model. Henson, et al., deduced the kinetics and thermodynamics of the phase transition, providing Dickson, et al. with the information necessary to develop a four-step model that included a two-step nucleation and growth mechanism for the {beta}-{delta} phase transition. Initially, an irreversible scheme was proposed. That model accurately predicted the spatial and temporal cook off behavior of the small-scale radial experiment under slow heating conditions, but did not accurately capture the endothermic phase transition at a faster heating rate. The current version of the four-step model includes reversibility and accurately describes the small-scale radial experiment over a wide range of heating rates. We have observed impact-induced friction ignition of PBX 9501 with grit embedded between the explosive and the lower anvil surface. Observation was done using an infrared camera looking through the sapphire bottom anvil. Time to ignition and temperature-time behavior were recorded. The time to ignition was approximately 500 microseconds and the temperature was approximately 1000 K. The four step reversible kinetic scheme was previously validated for slow cook off scenarios. Our intention was to test the validity for significantly faster hot-spot processes, such as the impact-induced grit friction process studied here. We found the model predicted the ignition time within experimental error. There are caveats to consider when evaluating the agreement. The primary input to the model was friction work over an area computed by a stress analysis. The work rate itself, and the relative velocity of the grit and substrate both have a strong dependence on the initial position of the grit. Any errors in the analysis or the initial grit position would affect the model results. At this time, we do not know the sensitivity to these issues. However, the good agreement does suggest the four step kinetic scheme may have universal applicability for HMX systems.

36 MATERIALS SCIENCE↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method of Determining the Reliability of Real-Time In-reactor Monitoring of VVER

A methodological approach and the basic tenets for evaluating the reliability of in-reactor monitoring of VVER are presented. The method is based on the statistical analysis of indications in real time and includes methods for evaluating the admissible maximum error of the measurement channels used for monitoring as well as the average value and admissible deviation of indications in groups of parallel monitoring channels, as well as a method of evaluating reliability by comparing the values of a parameter with the regime values. In comparing the indications of a monitoring channel with the indications of other parallel channels, the median value is proposed as the baseline value. The developed method is implemented in the Diagnostika SVRK special software, which has been successfully tested during the commissioning of the No. 1 unit at the Novovoronezh NPP-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine learning for endoleak detection after endovascular aortic repair

Diagnosis of endoleak following endovascular aortic repair (EVAR) relies on manual review of multi-slice CT angiography (CTA) by physicians which is a tedious and time-consuming process that is susceptible to error. We evaluate the use of a deep neural network for the detection of endoleak on CTA for post-EVAR patients using a novel data efficient training approach. 50 CTAs and 20 CTAs with and without endoleak respectively were identified based on gold standard interpretation by a cardiovascular subspecialty radiologist. The Endoleak Augmentor, a custom designed augmentation method, provided robust training for the machine learning (ML) model. Predicted segmentation maps underwent post-processing to determine the presence of endoleak. The model was tested against 3 blinded general radiologists and 1 blinded subspecialist using a held-out subset (10 positive endoleak CTAs, 10 control CTAs). Model accuracy, precision and recall for endoleak diagnosis were 95%, 90% and 100% relative to reference subspecialist interpretation (AUC = 0.99). Accuracy, precision and recall was 70/70/70% for generalist1, 50/50/90% for generalist2, and 90/83/100% for generalist3. The blinded subspecialist had concordant interpretations for all test cases compared with the reference. In conclusion, our ML-based approach has similar performance for endoleak diagnosis relative to subspecialists and superior performance compared with generalists.

60 APPLIED LIFE SCIENCES↗

Characterizing Performance of Freshwater Wetland Methane Models Across Time Scales at FLUXNET-CH 4 Sites Using Wavelet Analyses

Process-based land surface models are important tools for estimating global wetland methane (CH 4 ) emissions and projecting their behavior across space and time. So far there are no performance assessments of model responses to drivers at multiple time scales. In this study, we apply wavelet analysis to identify the dominant time scales contributing to model uncertainty in the frequency domain. We evaluate seven wetland models at 23 eddy covariance tower sites. Our study first characterizes site-level patterns of freshwater wetland CH 4 fluxes (FCH 4 ) at different time scales. A Monte Carlo approach was developed to incorporate flux observation error to avoid misidentification of the time scales that dominate model error. Our results suggest that (a) significant model-observation disagreements are mainly at multi-day time scales (<15 days); (b) most of the models can capture the CH 4 variability at monthly and seasonal time scales (>32 days) for the boreal and Arctic tundra wetland sites but have significant bias in variability at seasonal time scales for temperate and tropical/subtropical sites; (c) model errors exhibit increasing power spectrum as time scale increases, indicating that biases at time scales <5 days could contribute to persistent systematic biases on longer time scales; and (d) differences in error pattern are related to model structure (e.g., proxy of CH 4 production). Our evaluation suggests the need to accurately replicate FCH 4 variability, especially at short time scales, in future wetland CH 4 model developments.

58 GEOSCIENCES↗

First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target Tracking

Purpose: For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. Methods and Materials: The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millennium 120-leaf MLC. A gold marker in elliptical motion (2-cm superior-inferior, 1-cm left-right, 10 cycles/min) was simultaneously imaged by the kV and MV imagers at 6.7 Hz and segmented in real time. With these two-dimensional projections, the tracking software triangulated the three-dimensional marker position and repositioned the MLC leaves to follow the motion. Phantom studies were performed to evaluate time delay from image acquisition to MLC adjustment, tracking error, and dosimetric impact of target motion with and without tracking. Results: The time delay of the integrated tracking system was {approx}450 ms. The tracking error using a prediction algorithm was 0.9 {+-} 0.5 mm for the elliptical motion. The dose distribution with tracking showed better target coverage and less dose to surrounding region over no tracking. The failure rate of the gamma test (3%/3-mm criteria) was 22.5% without tracking but was reduced to 0.2% with tracking. Conclusion: For the first time, a complete tracking system combining kV/MV image-guided target tracking and DMLC beam tracking was demonstrated. The average geometric error was less than 1 mm, and the dosimetric error was negligible. This system is a promising method for intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

RECOVERY OF LARGE ANGULAR SCALE CMB POLARIZATION FOR INSTRUMENTS EMPLOYING VARIABLE-DELAY POLARIZATION MODULATORS

Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any time-varying effects that leak into the synchronously modulated component of the signal. In this paper, the effect of emission from a 300 K VPM on the system performance is considered and addressed. Though instrument design can greatly reduce the influence of modulated VPM emission, some residual modulated signal is expected. VPM emission is treated in the presence of rotational misalignments and temperature variation. Simulations of time-ordered data are used to evaluate the effect of these residual errors on the power spectrum. The analysis and modeling in this paper guides experimentalists on the critical aspects of observations using VPMs as front-end modulators. By implementing the characterizations and controls as described, front-end VPM modulation can be very powerful for mitigating 1/f noise in large angular scale polarimetric surveys. None of the systematic errors studied fundamentally limit the detection and characterization of B-modes on large scales for a tensor-to-scalar ratio of r = 0.01. Indeed, r < 0.01 is achievable with commensurately improved characterizations and controls.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗