Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Process tomography for unitary quantum channels

We study the number of measurements required for quantum process tomography under prior information, such as a promise that the unknown channel is unitary. We introduce the notion of an interactive observable and we show that any unitary channel acting on a d-level quantum system can be uniquely identified among all other channels (unitary or otherwise) with only O(d{sup 2}) interactive observables, as opposed to the O(d{sup 4}) required for tomography of arbitrary channels. This result generalizes to the problem of identifying channels with at most q Kraus operators, and slight improvements can be obtained if we wish to identify such a channel only among unital channels or among other channels with q Kraus operators. These results are proven via explicit construction of large subspaces of Hermitian matrices with various conditions on rank, eigenvalues, and partial trace. Our constructions are built upon various forms of totally nonsingular matrices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiscale microstructural characterization of Sn-rich alloys by three dimensional (3D) X-ray synchrotron tomography and focused ion beam (FIB) tomography

Sn-rich (Pb-free) alloys serve as electrical and mechanical interconnects in electronic packaging. It is critical to quantify the microstructures of Sn-rich alloys to obtain a fundamental understanding of their properties. In this work, the intermetallic precipitates in Sn-3.5Ag and Sn-0.7Cu, and globular lamellae in Sn-37Pb solder joints were visualized and quantified using 3D X-ray synchrotron tomography and focused ion beam (FIB) tomography. 3D reconstructions were analyzed to extract statistics on particle size and spatial distribution. In the Sn-Pb alloy the interconnectivity of Sn-rich and Pb-rich constituents was quantified. It will be shown that multiscale characterization using 3D X-ray and FIB tomography enabled the characterization of the complex morphology, distribution, and statistics of precipitates and contiguous phases over a range of length scales. - Highlights: Black-Right-Pointing-Pointer Multiscale characterization by X-ray synchrotron and focused ion beam tomography. Black-Right-Pointing-Pointer Characterized microstructural features in several Sn-based alloys. Black-Right-Pointing-Pointer Quantified size, fraction, and clustering of microstructural features.

36 MATERIALS SCIENCE↗

Quantum process tomography by 2D fluorescence spectroscopy

Reconstruction of the dynamics (quantum process tomography) of the single-exciton manifold in energy transfer systems is proposed here on the basis of two-dimensional fluorescence spectroscopy (2D-FS) with phase-modulation. The quantum-process-tomography protocol introduced here benefits from, e.g., the sensitivity enhancement ascribed to 2D-FS. Although the isotropically averaged spectroscopic signals depend on the quantum yield parameter Γ of the doubly excited-exciton manifold, it is shown that the reconstruction of the dynamics is insensitive to this parameter. Applications to foundational and applied problems, as well as further extensions, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.

Pelliccia, Daniele↗

Measuring Alignments between Galaxies and the Cosmic Web at z ∼ 2–3 Using IGM Tomography

Many galaxy formation models predict alignments between galaxy spin and the cosmic web (i.e., directions of filaments and sheets), leading to an intrinsic alignment between galaxies that creates a systematic error in weak-lensing measurements. These effects are often predicted to be stronger at high redshifts (z ≳ 1) that are inaccessible to massive galaxy surveys on foreseeable instrumentation, but IGM tomography of the Lyα forest from closely spaced quasars and galaxies is starting to measure the z ∼ 2–3 cosmic web with requisite fidelity. Using mock surveys from hydrodynamical simulations, we examine the utility of this technique, in conjunction with coeval galaxy samples, to measure alignment between galaxies and the cosmic web at z ∼ 2.5. We show that IGM tomography surveys with ≲5 h {sup −1} Mpc sightline spacing can accurately recover the eigenvectors of the tidal tensor, which we use to define the directions of the cosmic web. For galaxy spins and shapes, we use a model parameterized by the alignment strength, Δ〈cos θ〉, with respect to the tidal tensor eigenvectors from the underlying density field, and also consider observational effects such as errors in the galaxy position angle, inclination, and redshift. Measurements using the upcoming ∼1 deg{sup 2} CLAMATO tomographic survey and 600 coeval zCOSMOS-Deep galaxies should place 3σ limits on extreme alignment models with Δ〈cos θ〉∼0.1, but much larger surveys encompassing >10,000 galaxies, such as Subaru PFS, will be required to constrain models with Δ〈cos θ〉∼0.03. These measurements will constrain models of galaxy–cosmic web alignment and test tidal torque theory at z ∼ 2, improving our understanding of the physics of intrinsic alignments.

79 ASTRONOMY AND ASTROPHYSICS↗

Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2018. Part 1 of 2: Positron emission tomography, computed tomography, and magnetic resonance

In this review, we summarize key articles that have been published in the Journal of Nuclear Cardiology in 2018 pertaining to nuclear cardiology with advanced multi-modality and hybrid imaging including positron emission tomography, cardiac-computed tomography, and magnetic resonance. In an upcoming review, we will summarize key articles that relate to the progress made in the field of single-photon emission computed tomography. We hope that these sister reviews will be useful to the reader to navigate the literature in our field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography

Purpose: To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ({sup 90}Y) microsphere selective internal radiotherapy (SIRT). Methods and Materials: Fourteen consecutive {sup 90}Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Results: Positron emission tomography showed a significant decrease in total tumor standardized uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Conclusion: Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed {sup 90}Y SIRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of X-ray computed tomography for the characterization of graphite morphology in compact-graphite iron

Highlights: • X-ray Tomography is a powerful technique for graphite morphology characterization. • 3D characterization reveals true nodularity and spatial connectivity of graphite. • Tri-modal distribution of SG suggests a multi-stage graphite nucleation process. - Abstract: In the present study, high-energy X-ray tomography technique was used to characterize the graphite morphology of compact graphite iron. The size, shape, spatial connectivity and structure of different graphite morphologies were examined in 3D using computer-aided image analysis. In addition, nodularity analysis was performed in 3D and the results are compared to the traditional 2D technique. It is found that the variation of nodularity within 2 × 2 × 1.2 mm{sup 3} of the sample can be as high as 20 (%) from 2D analysis and the averaged nodularity (2D) is higher than that from 3D analysis. The size distribution of spheroidal graphite shows a tri-modal distribution, which suggests a multi-step nucleation process during solidification.

36 MATERIALS SCIENCE↗

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of BoneTtissue Mineralization by Conventional X-ray Microcomputed tomography: Comparison with Synchrotron Radiation Microcomputed Tomography and Ash Measurements

Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.

43 PARTICLE ACCELERATORS↗

Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets

Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance and diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C-Arm Computed Tomography Compared With Positron Emission Tomography/Computed Tomography for Treatment Planning Before Radioembolization

The purpose of this study was to determine whether rotational C-arm computed tomography (CT) allows visualization of liver metastases and adds relevant information for radioembolization (RE) treatment planning. Technetium angiography, together with C-arm CT, was performed in 47 patients to determine the feasibility for RE. C-arm CT images were compared with positron emission tomography (PET)/CT images for the detection of liver tumors. The images were also rated according one of the following three categories: (1) images that provide no additional information compared with DSA alone; (2) images that do provide additional information compared with DSA; and (2) images that had an impact on eligibility determination for and planning of the RE procedure. In all patients, 283 FDG-positive liver lesions were detected by PET. In venous contrast-phase CT, 221 (78.1%) and 15 (5.3%) of these lesions were either hypodense or hyperdense, respectively. In C-arm CT, 103 (36.4%) liver lesions were not detectable because they were outside of either the field of view or the contrast-enhanced liver segment. Another 25 (8.8%) and 98 (34.6%) of the liver lesions were either hyperdense or presented primarily as hypodense lesions with a rim enhancement, respectively. With PET/CT as the standard of reference, venous CT and C-arm CT failed to detect 47 (16.6%) and 57 (20.1%) of all liver lesions, respectively. For RE planning, C-arm CT provided no further information, provide some additional information, or had an impact on the procedure in 20 (42.5%), 15 (31.9%) and 12 (25.6%) of patients, respectively. We conclude that C-arm CT may add decisive information in patients scheduled for RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Standardized Uptake Value-Based Positron Emission Tomography and Computed Tomography Target Volumes in Esophageal Cancer Patients Undergoing Radiotherapy

Purpose: To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Methods and Materials: Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV {>=}2, {>=}2.5, {>=}3, {>=}3.5 (SUV{sub n}); {>=}40%, {>=}45%, and {>=}50% of the maximum (SUV{sub n%}); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV{sub Ln{sigma}}). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. Results: The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV{sub 2.5} (0.47 {+-} 0.03) and SUV{sub L4{sigma}} (0.48 {+-} 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV{sub 2.5} (1.18 {+-} 0.36) and SUV{sub L4{sigma}} (1.09 {+-} 0.15). The mean value of the SUVs calculated using the SUV{sub L4{sigma}} approach was 2.4. Conclusions: Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

[{sup 18}F]FDG-Positron Emission Tomography Coregistration With Computed Tomography Scans for Radiation Treatment Planning of Lymphoma and Hematologic Malignancies

Purpose: Positron emission-tomography (PET) using 2-[{sup 18}F]fluoro-2-deoxyglucose (FDG-PET) increases sensitivity and specificity of disease detection in lymphoma and thus is standard in lymphoma management. This study examines the effects of coregistering FDG-PET and computed tomography (CT) (PET/CT) scans on treatment planning for lymphoma patients. Methods and Materials: Twenty-nine patients (30 positive PET scans) underwent PET/CT treatment planning from July 2004 to February 2007 and were retrospectively studied. For each patient, gross tumor volume was blindly contoured on the CT-only and PET/CT studies by a radiation oncologist. Treatment plans were generated for both the CT-only and PET/CT planning target volumes (PTVs) for all patients. Normal tissue doses and PTV coverage were evaluated using dose--volume histograms for all sites. Results: Thirty-two treatment sites were evaluated. Twenty-one patients had non-Hodgkin lymphoma, 5 patients had Hodgkin lymphoma, and 3 patients had plasma cell neoplasms. Previously undetected FDG-avid sites were identified in 3 patients during PET/CT simulation, resulting in one additional treatment field. Due to unexpected PET/CT simulation findings, 2 patients did not proceed with radiation treatment. The addition of PET changed the volume of 23 sites (72%). The PTV was increased in 15 sites (47%) by a median of 11% (range, 6-40%) and reduced in 8 sites (25%) by a median of 20% (range, 6%-75%). In six (19%) replanned sites, the CT-based treatment plan would not have adequately covered the PTV defined by PET/CT. Conclusions: Incorporation of FDG-PET into CT-based treatment planning for lymphoma patients resulted in considerable changes in management, volume definition, and normal tissue dosimetry for a significant number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incorporating Quantitative Single Photon Emission Computed Tomography into Radiation Therapy Treatment Planning for Lung Cancer: Impact of Attenuation and Scatter Correction on the Single Photon Emission Computed Tomography-Weighted Mean Dose and Functional Lung Segmentation

Purpose: To assess the impact of attenuation and scatter corrections on the calculation of single photon emission computed tomography (SPECT)-weighted mean dose (SWMD) and functional volume segmentation as applied to radiation therapy treatment planning for lung cancer. Methods and Materials: Nine patients with lung cancer underwent a SPECT lung perfusion scan. For each scan, four image sets were reconstructed using the ordered subsets expectation maximization method with attenuation and scatter corrections ranging from none to a most comprehensive combination of attenuation corrections and direct scatter modeling. Functional volumes were segmented in each reconstructed image using 10%, 20%, ..., 90% of maximum SPECT intensity as a threshold. Systematic effects of SPECT reconstruction methods on treatment planning using functional volume were studied by calculating size and spatial agreements of functional volumes, and V{sub 20} for functional volume from actual treatment plans. The SWMD was calculated for radiation beams with a variety of possible gantry angles and field sizes. Results: Functional volume segmentation is sensitive to the particular method of SPECT reconstruction used. Large variations in functional volumes, as high as >50%, were observed in SPECT images reconstructed with different attenuation/scatter corrections. However, SWMD was less sensitive to the type of scatter corrections. SWMD was consistent within 2% for all reconstructions as long as computed tomography-based attenuation correction was used. Conclusion: When using perfusion SPECT images during treatment planning optimization/evaluation, the SWMD may be the preferred figure of merit, as it is less affected by reconstruction technique, compared with threshold-based functional volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗