Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Assessment of Long-term Trends in the Collection 4 Total Ozone Record from the Ozone Monitoring Instrument

Long-term changes in total ozone affect the amount of harmful UV radiation reaching Earth’s surface and reflect progress made towards recovery of stratospheric ozone. Satellite total ozone data are also used to estimate long-term trends in tropospheric ozone, a reactive and potent greenhouse gas, by subtracting the stratospheric column timeseries from that of total ozone. For these scientific applications, the long-term stability should be better than 1%. Left unchecked, instrument calibration drift can produce a trend of this magnitude or greater. NASA has produced nearly twenty years of total ozone data from the Ozone Monitoring Instrument (OMI) using the Total Ozone Mapping Spectrometer (TOMS) algorithm. The drift in the OMI instrument as monitored by ice radiance calibration has been relatively slow, but it has reached a level of ~3% over the mission lifetime. This drift was corrected in the recently released Collection 4 OMI calibrated radiances, updating the Collection 3 calibration released in 2006. We have reprocessed the OMI total ozone record using the Collection 4 calibration and updates to the TOMS algorithm. We summarize these changes and evaluate their impact by comparing to the previous Collection 3 OMI dataset, the Suomi NPP Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) and Solar Backscatter UV (SBUV) Merged Ozone Dataset (MOD) total ozone records and other independent satellite total ozone datasets. Climatological radiance residuals from OMI and OMPS-NM are calculated and compared to investigate differences in spectral calibration that can cause drifts in long-term total ozone trends. We also analyze the tropospheric ozone record produced using the Collection 4 OMI total ozone and stratospheric column ozone from MLS. Collection 3 OMI data processed with the TOMS algorithm show a positive drift relative to other satellite and ground-based data of 1-2 DU per decade. Initial results show that this drift is reduced in Collection 4 OMI, due to the updated OMI calibration. In this work we will quantify the improvements in Collection 4 OMI relative to independent data sources at both the ozone and radiance level

Collection 4 OMI Total Ozone↗

Computation of orbits using total energy

The computation of orbits can be done more efficiently by the use of any of several new formulations of the perturbed two body problem which consider the total energy of the orbital system as one of the dependent variables. The total energy is the osculating two body energy plus the potential energy due to perturbing masses. The use of the total energy as the dependent variable instead of the two body energy is a relatively new idea. The advantage of using total energy arises from the fact that the more perturbing potential energy that is accounted for in the total energy variable, the more nearly constant is the total energy. In fact, except for dissipative forces such as drag, the only reason for the total energy not being constant is the rotation or revolution of the perturbing mass. This near constancy of the total energy has the effect of inhibiting error growth during numerical solution. This paper will present the results of an application of total energy formulation to the problem of the precise computation of orbits.

Bond, Victor R.↗

The role of polar stratospheric clouds on total ozone minihole events

Using seven years of data from tha SAM 2 (Stratospheric Aerosol Measurement 2) and TOMS (Total Ozone Mapping Spectrometer) instruments, along with 70 mbar temperatures extracted from an NMC analysis, the effect of the austral spring polar stratospheric clouds (PSC) on the formation of total ozone miniholes is investigated. A total ozone minihole event is designated as the rapid decrease of more than 20 DU of total ozone over a time period of a day and a spatial extent of approximately 1000 by 1000 km. The severe decrease of total ozone during these minihole events could be explained in part by PSC being formed at altitudes of 10 to 24 km and preventing scattered UV radiation from ozone below the cloud from reaching the TOMS instrument. A result of the cloud's opaqueness is that the total ozone retrieval from TOMS data would underestimate the ozone column in the vicinity of the PSC. The approach to investigate the effect of PSC on total ozone was to use SAM 2 aerosol extinction values in conjunction with NMC stratospheric temperatures to determine if PSC are present during total ozone minihole events occurring during August and September, 1979 to 1986. The minihole events during these seven years were divided into two types: type 1, where the minihole region of 24 hour darkness from regions exposed to sunlight, and type 2, where the minihole occurred 5 to 10 degrees north of the terminator. The presence of PSC in a given region was ascertained by a maximum aerosol extinction greater than .006/km occurring with a temperature less than 189 K. It is found that PSC are consistently present with type 2 minihole events. This is contrasted with PSC rarely occurring in the same vicinity of type 2 miniholes. Also observed of that type 1 minihole events have minimum total ozone values which are on the average 3 to 10 DU smaller than type 2 miniholes. It can be concluded that care must be taken when trying to deduce a dynamical explanation of minihole events near the polar terminator and the role of PSC must be accounted for in type 1 minihole formation.

Sabutis, Joseph L.↗

Highlights of TOMS Version 9 Total Ozone Algorithm

The fundamental basis of TOMS total ozone algorithm was developed some 45 years ago by Dave and Mateer. It was designed to estimate total ozone from satellite measurements of the backscattered UV radiances at few discrete wavelengths in the Huggins ozone absorption band (310-340 nm). Over the years, as the need for higher accuracy in measuring total ozone from space has increased, several improvements to the basic algorithms have been made. They include: better correction for the effects of aerosols and clouds, an improved method to account for the variation in shape of ozone profiles with season, latitude, and total ozone, and a multi-wavelength correction for remaining profile shape errors. These improvements have made it possible to retrieve total ozone with just 3 spectral channels of moderate spectral resolution (approx. 1 nm) with accuracy comparable to state-of-the-art spectral fitting algorithms like DOAS that require high spectral resolution measurements at large number of wavelengths. One of the deficiencies of the TOMS algorithm has been that it doesn't provide an error estimate. This is a particular problem in high latitudes when the profile shape errors become significant and vary with latitude, season, total ozone, and instrument viewing geometry. The primary objective of the TOMS V9 algorithm is to account for these effects in estimating the error bars. This is done by a straightforward implementation of the Rodgers optimum estimation method using a priori ozone profiles and their error covariances matrices constructed using Aura MLS and ozonesonde data. The algorithm produces a vertical ozone profile that contains 1-2.5 pieces of information (degrees of freedom of signal) depending upon solar zenith angle (SZA). The profile is integrated to obtain the total column. We provide information that shows the altitude range in which the profile is best determined by the measurements. One can use this information in data assimilation and analysis. A side benefit of this algorithm is that it is considerably simpler than the present algorithm that uses a database of 1512 profiles to retrieve total ozone. These profiles are tedious to construct and modify. Though conceptually similar to the SBUV V8 algorithm that was developed about a decade ago, the SBUV and TOMS V9 algorithms differ in detail. The TOMS algorithm uses 3 wavelengths to retrieve the profile while the SBUV algorithm uses 6-9 wavelengths, so TOMS provides less profile information. However both algorithms have comparable total ozone information and TOMS V9 can be easily adapted to use additional wavelengths from instruments like GOME, OMI and OMPS to provide better profile information at smaller SZAs. The other significant difference between the two algorithms is that while the SBUV algorithm has been optimized for deriving monthly zonal means by making an appropriate choice of the a priori error covariance matrix, the TOMS algorithm has been optimized for tracking short-term variability using month and latitude dependent covariance matrices.

Bhartia, Pawan↗

Expanding the Operational Use of Total Lightning Ahead of GOES-R

NASA's Short‐term Prediction Research and Transition Center (SPoRT) has been transitioning real‐time total lightning observations from ground‐based lightning mapping arrays since 2003. This initial effort was with the local Weather Forecast Offices (WFO) that could use the North Alabama Lightning Mapping Array (NALMA). These early collaborations established a strong interest in the use of total lightning for WFO operations. In particular the focus started with warning decision support, but has since expanded to include impact‐based decision support and lightning safety. SPoRT has used its experience to establish connections with new lightning mapping arrays as they become available. The GOES‐R / JPSS Visiting Scientist Program has enabled SPoRT to conduct visits to new partners and expand the number of operational users with access to total lightning observations. In early 2014, SPoRT conducted the most recent visiting scientist trips to meet with forecast offices that will used the Colorado, Houston, and Langmuir Lab (New Mexico) lightning mapping arrays. In addition, SPoRT met with the corresponding Center Weather Service Units (CWSUs) to expand collaborations with the aviation community. These visits were an opportunity to learn about the forecast needs of each office visited as well as to provide on‐site training for the use of total lightning, setting the stage for a real‐time assessment during May‐July 2014. With five lightning mapping arrays covering multiple geographic locations, the 2014 assessment has demonstrated numerous uses of total lightning in varying situations. Several highlights include a much broader use of total lightning for impact‐based decision support ranging from airport weather warnings, supporting fire crews, and protecting large outdoor events. The inclusion of the CWSUs has broadened the operational scope of total lightning, demonstrating how these data can support air traffic management, particularly in the Terminal Radar Approach Control Facilities (TRACON) region around an airport. These collaborations continue to demonstrate, from the operational perspective, the utility of total lightning and the importance of continued training and preparation in advance of the Geostationary Lightning Mapper.

GLM↗

Theoretical analysis of total-pressure loss and airflow distribution for tubular turbojet combustors with constant annulus and liner cross-sectional areas

Compressible and incompressible flow calculations were made of the combustor total-pressure-loss coefficient and liner airflow distribution for tubular turbojet combustors having constant annulus and liner cross-sectional areas along the combustor axis. Information on static and total pressure distribution and liner air-jet entrance angles along the length of the combustor was obtained as an intermediate step in the calculations. The calculations include the effects of heat release, annulus wall friction, and variation in discharge coefficients of the liner wall openings along the combustor. The combustor total-pressure-loss coefficient and liner air-flow distribution are presented graphically in terms of the following dimensionless parameters: (1) combustor reference Mach number, (2) ratio of combustor-exit to inlet total temperature, (3) fraction of total airflow passing through the liner dome, (4) ratio of total open hole area in liner wall to total combustor cross-sectional area, and (5) ratio of liner cross-sectional area to total combustor cross-sectional area.

Graves, Charles C↗

Determination of ram-jet combustion-chamber temperatures by means of total-pressure surveys

A method is described by which the total temperature of the gases at the combustion-chamber outlet of a ram-jet engine may be determined from the loss in total pressure measured across the combustion chamber. A working chart is presented by means of which the ratio of the total temperature of the gases at the combustion-chamber outlet to the total temperature of the gases at the combustion-chamber inlet may be determined from the measured loss of total pressure across the combustion chamber and the known values of air flow, total pressure, and total temperature at the combustion-chamber inlet. Values of total-temperature ratio across the combustion chamber of a 20-inch ram jet were obtained in the Cleveland altitude wind tunnel over a range of pressure altitudes from 6000 to 15,000 feet. The difference between the temperature ratio across the combustion chamber determined from the chart and that obtained from the thermocouple measurement was within 6.2 percent of the thermocouple-temperature ratio and was within the accuracy of the thermocouple measurements.

Pinkel, I Irving↗

Trends in total column ozone measurements

It is important to ensure the best available data are used in any determination of possible trends in total ozone in order to have the most accurate estimates of any trends and the associated uncertainties. Accordingly, the existing total ozone records were examined in considerable detail. Once the best data set has been produced, the statistical analysis must examine the data for any effects that might indicate changes in the behavior of global total ozone. The changes at any individual measuring station could be local in nature, and herein, particular attention was paid to the seasonal and latitudinal variations of total ozone, because two dimensional photochemical models indicate that any changes in total ozone would be most pronounced at high latitudes during the winter months. The conclusions derived from this detailed examination of available total ozone can be split into two categories, one concerning the quality and the other the statistical analysis of the total ozone record.

Rowland, F. S.↗

Recent trends in stratospheric total ozone - Implications of dynamical and El Chichon perturbations

The recently reprocessed Nimbus-7 TOMS total ozone data from 1979 to 1989 are analyzed to assess the global impact of the El Chichon volcanic eruption on stratospheric total ozone. An apparent decrease in total ozone of 5 to 6 percent is present during the winter of 1982-1983 following the eruption of El Chichon. A regression analysis of total ozone with the equatorial zonal wind at 30 mb indicates that response to the quasi-biennial oscillation can explain much of the observed ozone anomaly, and that the total ozone decrease which can be attributed to El Chichon is at most 2 to 4 percent. This study also suggests that the interannual variability caused by the quasi-biennial oscillation and planetary wave activity may introduce apparent seasonal trends in total ozone and temperature in the lower stratosphere, particularly if the length of the data record is not very long. Such trends may affect the assessment of total ozone changes caused by chemical perturbations.

Chandra, S.↗

Observations of Total Lightning Associated with Severe Convection During the Wet Season in Central Florida

This paper will discuss findings of a collaborative lightning research project between National Aeronautics and Space Administration, the Massachusetts Institute of Technology and the National Weather Service office In Melbourne Florida. In August 1996, NWS/MLB received a workstation which incorporates data from the KMLB WSR-88D, Cloud to Ground (CG) stroke data from the National Lightning Detection Network (NLDN), and 3D volumetric lightning data collected from the Kennedy Space Centers' Lightning Detection And Ranging (LDAR) lightning system. The two primary objectives of this lightning workstation, called Lightning Imaging Sensor Data Applications Display (USDAD), are to: observe how total lightning relates to severe convective storm morphology over central Florida, and compare ground based total lightning data (LDAR) to a satellite based lightning detection system. This presentation will focus on objective #1. The LISDAD system continuously displays CG and total lighting activity overlaid on top of the KMLB composite reflectivity product. This allows forecasters to monitor total lightning activity associated with convective cells occurring over the central Florida peninsula and adjacent coastal waters. The LISDAD system also keeps track of the amount of total lightning data, and associated KMLB radar products with individual convective cells occurring over the region. By clicking on an individual cell, a history table displays flash rate information (CG and total lightning) in one minute increments, along with radar parameter trends (echo tops, maximum dBz and height of maximum dBz) every 5 minutes. This history table Is updated continuously, without user intervention, as long as the cell is identified. Reviewing data collected during the 1997 wet season (21 cases) revealed that storms which produced severe weather (hall greater or = 0.75 in. or wind damage) typically showed a rapid rise In total lightning prior to the onset of severe weather. On average, flash rate increases of 25 FPM per minute over a time scale of approximately 5 minutes were common. These pulse severe storms typically reached values of 150 to 200 FPM with some cells exceeding 400 FPM. One finding which could have a direct application to the warning process is that the rapid increase in lightning typically occurred in advance of the warning issuance time. Comparisons between the ending time of the rapid rate increase and the time of when the warning was issued by NWS/MLB meteorologist exhibited a lead time of 8 minutes. It is conceivable that if close monitoring of the LISDAD system by operational meteorologist is routinely performed, warnings for pulse severe storms could be issued up to 4 to 6 minutes earlier than what is issued currently.

Sharp, D.↗

Role of Stratospheric Air in a Severe Weather Event: Analysis of Potential Vorticity and Total Ozone

The role of dry stratospheric air descending to low and middle tropospheric levels in a severe weather outbreak in the midwestern United States is examined using ACCEPT Eta model output, Rapid Update Cycle (RUC) analyses, and Earth probe Total Ozone Mapping Spectrometer (EP/TOMS) total ozone data. While stratospheric air was not found to play a direct role in the convection, backward trajectories show stratospheric air descended to 800 hPa just west of the convection. Damaging surface winds not associated with thunderstorms also occurred in the region of greatest stratospheric descent. Small-scale features in the high-resolution total ozone data compare favorably with geopotential heights and potential vorticity fields, supporting the notion that stratospheric air descended to near the surface. A detailed vertical structure in the potential vorticity appears to be captured by small-scale total ozone variations. The capability of the total ozone to identify mesoscale features assists model verification. The total ozone data suggest biases in the RUC analysis and Eta forecast of this event. The total ozone is also useful in determining whether potential vorticity is of stratospheric origin or is diabatically generated in the troposphere.

Goering, Melissa A.↗

Total Lightning Characteristics with Respect to Radar-Derived Mesocyclone Strength

Recent work investigating the microphysical and kinematic relationship between a storm's updraft, its total lightning production, and manifestations of severe weather has resulted in development of tools for improved nowcasting of storm intensity. The total lightning jump algorithm, which identifies rapid increases in total lightning flash rate that often precede severe events, has shown particular potential to benefit warning operations. Maximizing this capability of total lightning and its operational implementation via the lightning jump may best be done through its fusion with radar and radar‐derived intensity metrics. Identification of a mesocyclone, or quasi‐steady rotating updraft, in Doppler velocity is the predominant radar‐inferred early indicator of severe potential in a convective storm. Fused lightning‐radar tools that capitalize on the most robust intensity indicators would allow enhanced situational awareness for increased warning confidence. A foundational step toward such tools comes from a better understanding of the updraft‐centric relationship between intensification of total lightning production and mesocyclone development and strength. The work presented here utilizes a sample of supercell case studies representing a spectrum of severity. These storms are analyzed with respect to total lightning flash rate and the lightning jump alongside mesocyclone strength derived objectively from the National Severe Storms Laboratory (NSSL) Mesocyclone Detection Algorithm (MDA) and maximum azimuthal shear through a layer. Early results indicate that temporal similarities exist in the trends between total lightning flash rate and low‐ to mid‐level rotation in supercells. Other characteristics such as polarimetric signatures of rotation, flash size, and cloud‐to‐ground flash ratio are explored for added insight into the significance of these trends with respect to the updraft and related processes of severe weather production.

Stough, Sarah M.↗

Global distribution of total ozone derived from Nimbus 3 satellite during April July, 1969 and its implication to upper tropospheric circulation

Utilizing a stepwise multiple regression scheme, monthly mean global maps of total ozone are produced from the spectral intensity measurements made by the infrared interferometer spectrometer (IRIS) onboard the Nimbus 3 satellite for the period April 18 to July 22, 1969. These maps show that over the equatorial regions total ozone increases steadily from April to July. Further, latitudinal variation of total ozone derived from these maps shows that the ozone increases at all latitudes over the Southern Hemisphere uniformly from April to July while over the Northern Hemisphere the monthly decrease at all latitudes is nonuniform. In general, these maps bear a close resemblance to the upper tropospheric circulation. It is observed that the total ozone is best correlated with the 200 mb geopotential heights. This relationship enables the utilization of total ozone as a quasi-stream function to determine geostrophic winds at 200 mb level. Further, even at low latitudes where the total ozone does not bear simple relationship to the geopotential heights the course of the easterly jet stream with the help of the ozone measurements can be identified.

Prabhakara, C.↗

First results from the Nimbus 7 total ozone mapping spectrometer

The Total Ozone Mapping Spectrometer (TOMS) instrument was launched on the Nimbus 7 satellite in October 1978. This instrument is designed to measure spatial variations in the total ozone field. The employed technique is an extension of the Backscattered Ultraviolet (BUV) total ozone method. The TOMS instrument has an improved capability for detailed monitoring of total ozone. The obtained data appear to contain information about dynamical processes in the upper troposphere and the lower stratosphere. Investigations are being conducted to determine qualitatively the conditions, if any, where total ozone fails as a predictor for tropopause height. Quantitative relations between the dynamic parameters and total ozone are also being studied.

Krueger, A. J.↗

Upper-tropospheric and lower-stratospheric dynamics associated with tropical cyclones as inferred from total ozone measurements

Total ozone associated with western Atlantic and Pacific tropical cyclones at different developmental stages is analyzed in an attempt to monitor the lower-stratospheric and upper-tropospheric mass adjustment processes associated with the tropical cyclone and its environment. The analysis is based on total ozone measurements obtained using the total ozone mapping spectrometer onboard the Nimbus-7. In order to study the total ozone within and surrounding the tropical cyclone, the storm is divided into four regions: the environment, the moat, the central dense overcast, and the eye. Tropical Cyclone Allen is used to discuss the total ozone features that are typical of other western Atlantic and Pacific storms. Western Pacific storms are emphasized in the discussion of the eye total ozone distribution.

Rodgers, Edward↗

The morphology of Antarctic total ozone as seen by TOMS

A more detailed examination of the TOMS observations reveals a number of important aspects of the Antarctic ozone depletion. First, it is noted that the presence of large scale disturbances around the edge of the ozone hole can lead to highly variable station observations. Second, an examination of the zonal mean total ozone for the seven Octobers shows that the large systematic decline is not simply confined to the polar region but exists at midlatitudes as well. Integrations of the total ozone from the South Pole northwards show that a portion of the systematic trend of decreasing Antarctic total ozone (prior to 1985) seems to be due to a redistribution of total ozone to subpolar and midlatitude regions. That is, decreases at high latitudes are compensated by increases at lower latitudes. The correlation between zonal mean total ozone and 70 mb zonal mean temperatures from polar to midlatitudes shows that the systematic decreases in total ozone is well correlated with a systematic decrease in stratospheric temperatures.

Schoeberl, Mark R.↗

Total ozone during the 88-89 Northern Hemisphere winter

Total ozone values measured by the Total Ozone Mapping Spectrometer during January, February, and March 1989 are analyzed. During this period, polar total ozone values did not reveal clear depletions, although average winter total ozone values indicate that a 2-6 percent ozone reduction has occurred in northern mid to high latitudes over the last 10 years. Rapid total ozone increases were seen during mid-February, resulting from a wave 2 major stratospheric warming. In order to track polar air over the warming period, total ozone trends are further analyzed using Ertel's potential vorticity.

Newman, Paul↗

Nimbus-7 total ozone observations of western North Pacific tropical cyclones

The Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) was used to map the distribution of total ozone around western North Pacific tropical cyclones from 1979 to 1982. The strong correlation between total ozone distribution and tropopause height found in the subtropical and midlatitudes made it possible for TOMS to monitor the propagation of upper-tropospheric waves and the mutual adjustment between these waves and tropical cyclones during their interaction. Changes in these total ozone patterns reflect the 3D upper-tropospheric transport processes that are involved in tropical cyclone intensity and intensity and motion changes. The total ozone distributions indicate that: (1) the mean upper-tropospheric circulations associated with western North Pacific and Atlantic tropical cyclones are similar; (2) more intense tropical cyclones have higher tropopauses around their centers; (3) more intense tropical cyclones have higher tropopauses on the anticyclonic-shear side of their outflow jets, which indicate that the more intense tropical cyclones have stronger outflow channels than less intense systems; (4) tropical cyclones that intensify (do not intensify) are within 10 deg (15 deg) latitude of weak (strong) upper-tropospheric troughs that are moderately rich (very rich) in total ozone; and (5) tropical cyclones turn to the left (right) when they move within approximately 15 deg latitude downstream of an ozone-poor (ozone-rich) upper-tropospheric ridge (trough).

Stout, John↗