A Novel Three-Phase Oak Ridge AC / DC Converter for Wireless EV Charger Applications

In this paper, a novel three-phase converter is proposed for ac to dc wireless power transfer (WPT) systems for electric vehicle (EV) charging applications. The proposed innovative solution, called as Oak Ridge Converter, reduces the design complexity and cost by eliminating the front-end converter stage compared to the conventional systems. Additionally, grid side requirements can be met with the proposed creative concept. In this concept, the three-phase single-stage Oak Ridge Converter directly converts the 60 Hz grid frequency into high-frequency voltage and utilizes hybrid grid-source and high-frequency to realize power transfer from AC source through resonant network and coupling coils to the battery load. Simulation validation of the proposed three-phase system is currently being carried on and the results will be will be provided to validate the theoretical studies with the input of 277 VAC,RMS and output of 675 VDC at 35 kW power. The system current total harmonic distortion (THD) is measured 5% with a power factor (PF) of 0.98 and overall hardware development of the system that will be used for experiments is presented.

Asa, Erdem↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Harmonic Analysis of Electric Vehicle Loadings on Distribution System

With the increasing number of Electric Vehicles (EV) in this age, the power system is facing huge challenges of the high penetration rates of EVs charging stations. Therefore, a technical study of the impact of EVs charging on the distribution system is required. This paper is applied with PSCAD software and aimed to analyzing the Total Harmonic Distortion (THD) brought by Electric Vehicles charging stations in power systems. The paper starts with choosing IEEE34 node test feeder as the distribution system, building electric vehicle level two charging battery model and other four different testing scenarios: overhead transmission line and underground cable, industrial area, transformer and photovoltaic (PV) system. Then the statistic method is used to analyze different characteristics of THD in the plug-in transient, plug-out transient and steady-state charging conditions associated with these four scenarios are taken into the analysis. Finally, the factors influencing the THD in different scenarios are found. The analyzing results lead the conclusion of this paper to have constructive suggestions for both Electric Vehicle charging station construction and customers' charging habits.

Xu, Yijun A↗

Vulnerability Assessments for Power-Electronics-Based Smart Grids

Here, in this paper, a novel method is proposed to evaluate the cyber security of the power-electronics-based smart grids (PESG). The proposed method considers the performance and stability of both the individual inverter and the grid. To our knowledge, this is a first attempt to evaluate the performance and stability of PESG due to cyber attacks. We first develop impedance-based modeling and cyber-attack modeling for PESG. Then we propose innovative two security criteria to evaluate the security of PESG, including stability-based and metrics-based. For metrics-based criteria, we propose to use both total harmonic distortion (THD) and space phasor model (SPM) to evaluate the inverter performance. The simulation results with a two-inverter-based power grid verify the validity and accuracy of the proposed security evaluation method. Results have shown that the performance and stability of PESG are significantly affected by cyber attacks, and thus there is indeed a need to further study cyber security issues of PESG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Optimal Variable Switching Frequency Scheme to Reduce Loss of Single-Phase Grid-Connected Inverter With Unipolar and Bipolar PWM

Reducing the power loss of a converter without increasing its volume or cost in hardware has always been a much sought-after but challenging goal. This article proposes a comprehensive variable switching frequency (VSF) scheme to improve the overall system efficiency while still meeting a given total harmonic distortion (THD) requirement without any hardware changes, achieved only by changes to the controller. In this article, it is analyzed that for the H-bridge inverter, the inductor copper loss and the switch conduction loss are independent of the switching frequency (SF), while the device switching loss and the inductor core loss are functions of the SF. This article aims at weighting the combined switching loss and inductor core loss for both the unipolar and bipolar modulation techniques, with the constraint on the output THD, which, for fixed passive components, is a function of inductor ripple current that in turn depends on the SF. An optimal VSF scheme is devised through rigorous mathematical analysis of the output ripple component and the SF-dependent losses. In each switching cycle, the inductor ripple current is predicted with the circuit parameters, such as duty cycle, switching period, inductance, and dc voltage, and by implementing the VSF scheme, the current ripple is optimally varied such as to satisfy the THD requirement while reducing the SF-dependent losses. A generalized method to design VSF schemes for any topology and specifications is also presented, which would help future users in designing the VSF controller. A 1-kW H-bridge inverter using SiC MOSFETs and powdered iron/ferrite core has been built to validate the theoretical analysis. Both constant SF (CSF) scheme (200 kHz) and optimal VSF scheme with simple controller modification have been implemented in the experimental prototype using DSP TMS320f28335. Compared with the CSF scheme, the optimal VSF scheme shows a significant improvement in the system efficiency at rated power from 94.7%...

conduction loss↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Reduced Switching Frequency Active Harmonic Elimination for Multilevel Converters

This paper presents a reduced switching-frequency active-harmonic-elimination method (RAHEM) to eliminate any number of specific order harmonics of multilevel converters. First, resultant theory is applied to transcendental equations to eliminate low-order harmonics and to determine switching angles for a fundamental frequency-switching scheme. Next, based on the number of harmonics to be eliminated, Newton climbing method is applied to transcendental equations to eliminate high-order harmonics and to determine switching angles for the fundamental frequency-switching scheme. Third, the magnitudes and phases of the residual lower order harmonics are computed, generated, and subtracted from the original voltage waveform to eliminate these low-order harmonics. Compared to the active-harmonic-elimination method (AHEM), which generates square waves to cancel high-order harmonics, RAHEM has lower switching frequency. The simulation results show that the method can effectively eliminate all the specific harmonics, and a low total harmonic distortion (THD) near sine wave is produced. An experimental 11-level H-bridge multilevel converter with a field-programmable gate-array controller is employed to experimentally validate the method. The experimental results show that RAHEM does effectively eliminate any number of specific harmonics, and the output voltage waveform has low switching frequency and low THD.

42 ENGINEERING↗

Decentralized Carrier Phase Shifting for Optimal Harmonic Minimization in Asymmetric Parallel-Connected Inverters

This paper presents a carrier phase shifting technique for minimizing the aggregate harmonics in networks of asymmetric parallel-connected inverters for distributed power generation system applications. The proposed technique is: 1) implemented in a decentralized manner, relying only on local voltage and current measurements, and 2) optimal in the sense that it minimizes a cost function representing the carrier-frequency current harmonics. The analysis indicates that the proposed optimal carrier phase shifting technique can enable order-of-magnitude reductions in harmonic power, and also universal improvements compared to symmetric carrier interleaving for asymmetric inverter networks. Moreover, compared to existing methods that require either centralized communication or information exchange between inverters to coordinate carriers, the proposed technique is completely decentralized, which provides important practical benefits for implementation, including improved robustness and reduced cost. The technique is experimentally validated on a network of three single-phase 2-kW inverters and demonstrates a 36.5% reduction in the weighted total harmonic distortion factor of the aggregate inverter current, and the ability to converge to the optimal carrier phase spacing dynamically in less than one line frequency cycle (16.7 ms) in steady state and transient operating conditions.

42 ENGINEERING↗

Topological Equivalence of VSI and CSI Commutation Cells and Its Application to Switching Resonance Analysis and Damper Design

This paper proposes the concept of the topological equivalence between the commutation cells of a voltage source inverter (VSI) and a current source inverter (CSI) using duality and equivalent circuit transformation techniques. A switching resonance of CSI is analyzed and an effective three-phase RC damper is derived from the dc-link RC damper of VSIs based on the topological equivalence of the VSI and CSI commutation cells. Furthermore, a new three-phase RC damper design framework utilizing the topological equivalence is proposed. Here, experimental results verify that the proposed three-phase RC damper design for CSI significantly reduces the switching resonance and improves the CSI’s output waveform total harmonics distortions (THDs).

42 ENGINEERING↗

A Bidirectional High-Power-Quality Grid Interface With a Novel Bidirectional Noninverted Buck Boost Converter for PHEVs

Plug-in hybrid electric vehicles (PHEVs) will play a vital role in future sustainable transportation systems due to their potential in terms of energy security, decreased environmental impact, improved fuel economy, and better performance. Moreover, new regulations have been established to improve the collective gas mileage, cut greenhouse gas emissions, and reduce dependence on foreign oil. This paper primarily focuses on two major thrust areas of PHEVs. First, it introduces a grid-friendly bidirectional alternating current/direct current ac/dc dc/ac rectifier/inverter for facilitating vehicle-to-grid (V2G) integration of PHEVs. Second, it presents an integrated bidirectional noninverted buck boost converter that interfaces the energy storage device of the PHEV to the dc link in both grid-connected and driving modes. The proposed bidirectional converter has minimal grid-level disruptions in terms of power factor and total harmonic distortion, with less switching noise. The integrated bidirectional dc/dc converter assists the grid interface converter to track the charge/discharge power of the PHEV battery. In addition, while driving, the dc/dc converter provides a regulated dc link voltage to the motor drive and captures the braking energy during regenerative braking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Quality Down Lighting Luminaire with 73% Overall System Efficiency

This report summarizes work to develop a high flux, high efficiency LED-based downlight at OSRAM SYLVANIA under US Department of Energy contract DE-FC26-08NT01582. A new high power LED and electronic driver were developed for these downlights. The LED achieved 100 lumens per watt efficacy and 1700 lumen flux output at a correlated color temperature of 3500K. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.99, and total harmonic distortion <10%. Two styles of downlights using the LED and driver were shown to exceed the project targets for steady-state luminous efficacy and flux of 70 lumens per watt and 1300 lumens, respectively. Compared to similar existing downlights using compact fluorescent or LED sources, these downlights had much higher efficacy at nearly the same luminous flux.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Two Guralp Preamplifiers for GS21 Seismometer Application

Sandia National Laboratories has tested and evaluated two Guralp preamplifiers for use with a GS21 seismometer application. The two preamplifiers have a gain factor of 61.39. The purpose of the preamplifier evaluation was to determine a measured gain factor, transfer function, total harmonic distortion, self-noise, application passband, dynamic range, seismometer calibration pass-through, and to comment on any issues encountered during the evaluation. The test results included in this report were in response to static, tonal, and dynamic input signals. The Guralp GS21 preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO). Test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗