Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ray-tracing analysis for cross-polarization scattering diagnostic on MAST-upgrade spherical tokamak

A combined Doppler backscattering/cross-polarization scattering (DBS/CPS) system is being deployed on MAST-U for simultaneous measurements of local density turbulence, turbulence flows, and magnetic turbulence. In this design, CPS shares the probing beam with the DBS and uses a separate parallel-viewing receiver system. In this study, we utilize a modified GENRAY 3D ray-tracing code to simulate the propagation of the probing and scattered beams. The contributions of different scattering locations along the entire beam trajectories are considered, and the corresponding local B̃ wavenumbers are estimated using the wavevector matching criterion. The wavenumber ranges of the local B̃ that are detectable to the CPS system are explored for simulated L- and H-mode plasmas.

Hong, R. (ORCID:0000000347508015)↗

APT malware static trace analysis through bigrams and graph edit distance

Research and business organizations are vulnerable to attack by malware, particularly advanced persistent threat malware tailored for a specific target. Malware identification is made more difficult because samples can be subtly altered to avoid detection by methods that check for an identical match to known code. Different versions of an original piece of malware form a malware family. And when new malicious software is identified, reverse engineers seek to identify its origin and purpose. Knowing whether new malware is from a known family or a previously unobserved family aids the efficiency of reverse engineers. Furthermore, this article presents a three-stage method to classify new malware into a family by comparing its similarity to existing static traces, and assigning it to the most similar family. First, a fast filtering method creates a shortlist of samples with some similarity to the new malware, using a simple bigram comparison of the instructions. The second stage takes the call graph view of the shortlisted static traces and uses simulated annealing to estimate the graph edit distance, a measure of dissimilarity between graphs. Finally, a random forest classifier combines the previous two results to predict the family to which a new sample belongs. Our paper also considers how to detect when malware is from a new family.

97 MATHEMATICS AND COMPUTING↗

Extraction and Trace Analysis of Trihalomethanes in Water Samples Using Zein@Fe{sub 3}O{sub 4} Nanocomposite

This study presents a simple dispersive solid phase extraction (DSPE) technique combined with headspace thermal desorption (HSTD) for extraction and determination of the most significant trihalomethanes (THMs), bromodichloromethane, bromoform, chloroform and dibromochloromethane, in water samples by using Zein@Fe{sub 3}O{sub 4} nanocomposite coupled with gas chromatography/micro electron capture detection (GC–MECD). Various parameters affecting the DSPE-HSTD performance were investigated and optimized. The obtained results revealed that under optimum conditions, LOD and LOQ values were in the range of 0.1–0.36, 0.3–1.08 µg L{sup −1}, respectively. The intra-day and inter-day precisions of the method at a concentration of 10 µg L{sup −1} for each analyte (n = 5) were obtained in the range of 5.69–6.70% and 6.12–7.34%, respectively. Finally, the proposed method was successfully applied for extraction and determination of four THMs in drinking water samples.

54 ENVIRONMENTAL SCIENCES↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New methods for trace analysis of gamma-irradiated pentaerythritol tetranitrate

High explosives (HEs) are used in a diverse range of applications in which they could be exposed to various radiation levels that may cause potential chemical changes. This study further evaluated pentaerythritol tetranitrate (PETN) that was previously aged with a low-level 2 kGy dose of gamma irradiation in order to understand chemical changes caused by irradiation. Both unirradiated PETN and gamma-irradiated PETN were analyzed using ultra high-pressure liquid chromatography coupled to quadrupole time of flight mass spectrometry (UHPLC-QTOF). The resulting data were processed in a non-targeted manner using Fisher's ratio analysis and multivariate curve resolution-alternating least squares (MCR-ALS) to aid in discovery and identification of the chemical changes brought about by irradiation without a priori knowledge. The application of using UHPLC-QTOF in combination with chemometric techniques for the analysis of irradiated samples has not previously been performed. Here, in this work, we show how to use this method to provide chemical information that would otherwise not be discernible, such as the discovery of degradation of the various homologues of PETN. Major differences identified with radiolytic aging of the PETN sample included decomposition products that resulted from the degradation of the trigger linkage – the O–NO 2 bonds – resulting in the formation of alcohol and aldehyde groups. Similar degradation was also observed in the PETN homologues as well as interconversion from one homologue to another.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotopic abundance in atom trap trace analysis

A method and system for detecting ratios and amounts of isotopes of noble gases. The method and system is constructed to be able to measure noble gas isotopes in water and ice, which helps reveal the geological age of the samples and understand their movements. The method and system uses a combination of a cooled discharge source, a beam collimator, a beam slower and magneto-optic trap with a laser to apply resonance frequency energy to the noble gas to be quenched and detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent advances in analysis of trace elements in environmental samples by X-ray based techniques (IUPAC Technical Report)

Trace elements analysis is a foundational challenge in environmental sciences. Scientists measure trace elements in environmental media in order to assess the quality and safety of ecosystems and to quantify the burden of anthropogenic pollution. Among the available analytical techniques, X-ray based methods are particularly powerful, as they can quantify trace elements in situ . Chemical extraction is not required, as is the case for many other analytical techniques. In the last few years, the potential for X-ray techniques to be applied in the environmental sciences has dramatically increased due to developments in laboratory instruments and synchrotron radiation facilities with improved sensitivity and spatial resolution. In this report, we summarize the principles of the X-ray based analytical techniques most frequently employed to study trace elements in environmental samples. We report on the most recent developments in laboratory and synchrotron techniques, as well as advances in instrumentation, with a special attention on X-ray sources, detectors, and optics. Lastly, we inform readers on recent applications of X-ray based analysis to different environmental matrices, such as soil, sediments, waters, wastes, living organisms, geological samples, and atmospheric particulate, and we report examples of sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace impurity analysis in uranium oxide via hybrid quantification techniques—gravimetric standard addition and isotope dilution mass spectrometry

Measurement methods for the analysis of trace impurities in uranium materials, essential in nuclear fuel production and nuclear forensics, are continuously improving. Analytical methods were developed with the goal of lowering uncertainties of next generation certified uranium oxide reference materials for trace impurity concentrations. Through addition of a traceable standard directly into the sample, gravimetric standard addition and isotope dilution followed by analysis on an inductively coupled plasma mass spectrometer can achieve lower uncertainties. In conclusion, results for 28 impurities in CRM 124-1 and 124-6 from NBL Program Office were used for validation of accuracy and comparisons of uncertainties.

36 MATERIALS SCIENCE↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Experimental characterization and crystal plasticity modeling of heterogeneous deformation in polycrystalline {alpha}-Ti.

Grain-level heterogeneous deformation was studied in a polycrystalline {alpha}-Ti specimen deformed by four-point bending. Dislocation slip activity in the microstructure was investigated by surface slip trace analysis. Three-dimensional-X-ray diffraction (3D-XRD) was used to investigate subsurface lattice rotations and to identify geometrically necessary dislocations (GNDs). The slip systems of local GNDs were analyzed by studying the streaking directions of reflections in corresponding Laue patterns. The analysis performed in one grain indicated that the subsurface GNDs were from the same slip system identified using slip trace analysis in backscattered electron images. A crystal plasticity finite element (CPFE) model was used to simulate deformation of the same microstructural region. The predictions of dislocation slip activity match the general aspects of the experimental observations, including the ability to simulate the activation of different slip systems in grains where multiple slip systems were activated. Prediction of local crystal rotations, however, was the least accurate aspect of the CPFE model.

36 MATERIALS SCIENCE↗

Trace element analysis of soil type collected from the Manjung and central Perak

Trace elements in soils primarily originated from their parent materials. Parents’ material is the underlying geological material that has been undergone different types of chemical weathering and leaching processes. Soil trace elements concentrations may be increases as a result of continuous input from various human activities, including power generation, agriculture, mining and manufacturing. This paper describes the Neutron Activation Analysis (NAA) method used for the determination of trace elements concentrations in part per million (ppm) present in the terrestrial environment soil in Perak. The data may indicate any contamination of trace elements contributed from human activities in the area. The enrichment factors were used to check if there any contamination due to the human activities (power plants, agricultural, mining, etc.) otherwise the values would serve as a baseline data for future study. The samples were collected from 27 locations of different soil series in the area at two different depths: the top soil (0-15cm) and the sub soil (15-30cm). The collected soil samples were air dried at 60°C and passed through 2 µm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia TRIGA Mark II reactor followed by gamma spectrometric analysis. By activating the stable elements in the samples, the elements can be determined from the intensities of gamma energies emitted by the respected radionuclides.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

The measurement uncertainty estimation associated with trace element analysis of impurities in U and Pu was evaluated using the Guide to the Expression of Uncertainty Measurement (GUM). I this evaluation the uncertainty sources were identified and standard uncertainties for the components were categorized as either Type A or B. The combined standard uncertainty was calculated and a coverage factor k = 2 was applied to obtain the expanded uncertainty, U. The ICP-AES and ICP-MS methods used were developed for the multi-element analysis of U and Pu samples. A typical analytical run consists of standards, process blanks, samples, matrix spiked samples, post digestion spiked samples and independent calibration verification standards. The uncertainty estimation was performed on U and Pu samples that have been analyzed previously as part of the U and Pu Sample Exchange Programs. Control chart results and data from the U and Pu metal exchange programs were combined with the GUM into a concentration dependent estimate of the expanded uncertainty. Comparison of trace element uncertainties obtained using this model was compared to those obtained for trace element results as part of the Exchange programs. This process was completed for all trace elements that were determined to be above the detection limit for the U and Pu samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation and Specifications for In-Line Uranium Separations Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) Detection for Trace Elemental Analysis

Automated introduction platforms integrated with inductively coupled plasma optical emission spectroscopy (ICP-OES) systems are continuously being improved. Expanding on the introduction systems, a newly developed automated ion chromatography system was explored for performing rapid in-line separations coupled to ICP-OES for the detection of trace elements in uranium. Trace elements are separated from a uranium material and the analytes are directed into the ICP-OES for subsequent detection. Detection parameters such as exposure time frequency, wavelength selection, and settling times were explored to gain insight on optimal detection schemes for in-line trace elemental analysis. The methodology was applied in the analysis of a uranium oxide (U3O8) certified reference material, CRM-124. It was found here that the sensitivity and uncertainty of the technique are greatly affected by how the ICP-OES is employed to collect data. Overall it was determined that faster exposure replicates can provide greater peak resolution with higher fidelity measurements but are limited with respect to the total analysis time (i.e., limited in detection timely separations). In conclusion zeta scores, which combine accuracy and uncertainty of certified values and experimental values, were used to validate the ICP-OES modes of operation.

47 OTHER INSTRUMENTATION↗

Stepwise chemical abrasion–isotope dilution–thermal ionization mass spectrometry with trace element analysis of microfractured Hadean zircon

Abstract. The Hadean Jack Hills zircons represent the oldest known terrestrial material, providing a unique and truly direct record of Hadean Earth history. This zircon population has been extensively studied via high-spatial-resolution high-throughput in situ isotopic and elemental analysis techniques, such as secondary ionization mass spectrometry (SIMS), but not by comparatively destructive, high-temporal-precision (<0.05 % two-sigma) thermal ionization mass spectrometry (TIMS). In order to better understand the lead loss and alteration history of terrestrial Hadean zircons, we conduct stepwise chemical abrasion–isotope dilution–thermal ionization mass spectrometry with trace element analysis (CA-ID-TIMS-TEA) on manually microfractured Hadean Jack Hills zircon fragments previously dated by SIMS. We conducted three successive HF leaching steps on each individual zircon fragment, followed by column chromatography to isolate U–Pb and trace element fractions. Following isotopic and elemental analysis, the result is an independent age and trace element composition for each leachate of each zircon fragment. We observe ~50 Myr of age heterogeneity in concordant residues from a single zircon grain, along with a protracted history of post-Hadean Pb loss with at least two modes circa ~0 and 2–4 Ga. Meanwhile, stepwise leachate trace element chemistry reveals enrichments of light rare earth elements, uranium, thorium, and radiogenic lead in early leached domains relative to the zircon residue. In addition to confirming the efficacy of the LREE-I alteration index and providing new insight into the mechanism of chemical abrasion, the interpretation and reconciliation of these results suggest that Pb loss is largely driven by low-temperature aqueous recrystallization and that regional thermal events may act to halt – not initiate – Pb loss from metamict domains in the Hadean Jack Hills zircons.

Brenhin Keller, C. (ORCID:0000000174009428)↗