At least 37 records · Page 2

Evaluating Impacts of CO2 Gas Intrusion Into a Confined Sandstone aquifer: Experimental Results

Deep subsurface storage and sequestration of CO2 has been identified as a potential mitigation technique for rising atmospheric CO2 concentrations. Sequestered CO2 represents a potential risk to overlying aquifers if the CO2 leaks from the deep storage reservoir. Experimental and modeling work is required to evaluate potential risks to groundwater quality and develop a systematic understanding of how CO2 leakage may cause important changes in aquifer chemistry and mineralogy by promoting dissolution/precipitation, adsorption/desorption, and redox reactions. Sediments from the High Plains aquifer in Kansas, United States, were used in this investigation, which is part of the National Risk Assessment Partnership Program sponsored by the US Department of Energy. This aquifer was selected to be representative of consolidated sand and gravel/sandstone aquifers overlying potential CO2 sequestration repositories within the continental US. In this paper, we present results from batch experiments conducted at room temperature and atmospheric pressure with four High Plains aquifer sediments. Batch experiments simulate sudden, fast, and short-lived releases of the CO2 gas as would occur in the case of well failure during injection. Time-dependent release of major, minor, and trace elements were determined by analyzing the contacting solutions. Characterization studies demonstrated that the High Plains aquifer sediments were abundant in quartz and feldspars, and contained about 15 to 20 wt% montmorillonite and up to 5 wt% micas. Some of the High Plains aquifer sediments contained no calcite, while others had up to about 7 wt% calcite. The strong acid extraction tests confirmed that in addition to the usual elements present in most soils, rocks, and sediments, the High Plains aquifer sediments had appreciable amounts of As, Cd, Pb, Cu, and occasionally Zn, which potentially may be mobilized from the solid to the aqueous phase during or after exposure to CO2. However, the results from the batch experiments showed that the High Plains sediments mobilized only low concentrations of trace elements (potential contaminants), which were detected occasionally in the aqueous phase during these experiments. Importantly, these occurrences were more frequent in the calcite-free sediment. Results from these investigations provide useful information to support site selection, risk assessment, and public education efforts associated with geological CO2 storage and sequestration.

54 ENVIRONMENTAL SCIENCES↗

A Priori Method of Using Photon Activation Analysis to Determine Unknown Trace Element Concentrations in NIST Standards

Photon activation analysis detected elements in two NIST standards that did not have reported concentration values. A method is currently being developed to infer these concentrations by using scaling parameters and the appropriate known quantities within the NIST standard itself. Scaling parameters include: threshold, peak and endpoint energies; photo-nuclear cross sections for specific isotopes; Bremstrahlung spectrum; target thickness; and photon flux. Photo-nuclear cross sections and energies from the unknown elements must also be known. With these quantities, the same integral was performed for both the known and unknown elements resulting in an inference of the concentration of the un-reported element based on the reported value. Since Rb and Mn were elements that were reported in the standards, and because they had well-identified peaks, they were used as the standards of inference to determine concentrations of the unreported elements of As, I, Nb, Y, and Zr. This method was tested by choosing other known elements within the standards and inferring a value based on the stated procedure. The reported value of Mn in the first NIST standard was 403{+-}15 ppm and the reported value of Ca in the second NIST standard was 87000 ppm (no reported uncertainty). The inferred concentrations were 370{+-}23 ppm and 80200{+-}8700 ppm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portable TXRF Spectrometer with 10{sup -11}g Detection Limit and Portable XRF Spectromicroscope with Sub-mm Spatial Resolution

A portable total reflection X-ray fluorescence (TXRF) spectrometer that we have developed is applied to trace elemental analysis of water solutions. Although a 5 W X-ray tube is used in the portable TXRF spectrometer, detection limits of several ppb are achieved for 3d transition metal elements and trace elements in a leaching solution of soils, a leaching solution of solder, and alcoholic beverages are detected. Portable X-ray fluorescence (XRF) spectromicroscopes with a 1 W X-ray tube and an 8 W X-ray tube are also presented. Using the portable XRF spectromicroscope with the 1 W X-ray tube, 93 ppm of Cr is detected with an about 700 {mu}m spatial resolution. Spatially resolved elemental analysis of a mug painted with blue, red, green, and white is performed using the two portable spectromicroscopes, and the difference in elemental composition at each paint is detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of trace phosphorus in steel using laser-induced breakdown spectroscopy combined with laser-induced fluorescence

Monitoring of light-element concentration in steel is very important for quality assurance in the steel industry. In this work, detection in open air of trace phosphorus (P) in steel using laser-induced breakdown spectroscopy (LIBS) combined with laser-induced fluorescence (LIF) has been investigated. An optical parametric oscillator wavelength-tunable laser was used to resonantly excite the P atoms within plasma plumes generated by a Q-switched Nd:YAG laser. A set of steel samples with P concentrations from 3.9 to 720 parts in 10{sup 6}(ppm) were analyzed using LIBS-LIF at wavelengths of 253.40 and 253.56 nm for resonant excitation of P atoms and fluorescence lines at wavelengths of 213.55 and 213.62 nm. The calibration curves were measured to determine the limit of detection for P in steel, which is estimated to be around 0.7 ppm. The results demonstrate the potential of LIBS-LIF to meet the requirements for on-line analyses in open air in the steel industry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Abstract for CRADA between NETL and GlycoSurf, Inc.

The National Energy Technology Laboratory (NETL) and GlycoSurf, Inc. (Participant) will collaborate in the development of novel luminescent sensing materials for rare earth elements using chemically modified surfactants. Rare earth elements are economically critical metals that are used in many technologies relevant to both energy and national defense. Slow and expensive characterization methods for rare earth element analysis are a major pain point for domestic production of these metals; the development of low-cost optical sensing materials and platforms can significantly reduce the time and financial costs associated with rare earth element prospecting and process monitoring. NETL has extensive experience developing inexpensive and compact optical sensors for critical metals such as rare earths. GlycoSurf, Inc. has commercialized high performance surfactants for the selective extraction of rare earth elements in complex environments such as acid mine drainage. By modifying these surfactants with fluorescent functional groups, trace concentrations of rare earths may be detected through a process called “photosensitization,” where the sensing material induces element-specific emission bands that enable different rare earth elements to be detected and distinguished. This project will enable the development of sensing materials capable of selectively detecting trace quantities of valuable rare earths in challenging conditions, including high ionic strength, highly acidic matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

The measurement uncertainty estimation associated with trace element analysis of impurities in U and Pu was evaluated using the Guide to the Expression of Uncertainty Measurement (GUM). I this evaluation the uncertainty sources were identified and standard uncertainties for the components were categorized as either Type A or B. The combined standard uncertainty was calculated and a coverage factor k = 2 was applied to obtain the expanded uncertainty, U. The ICP-AES and ICP-MS methods used were developed for the multi-element analysis of U and Pu samples. A typical analytical run consists of standards, process blanks, samples, matrix spiked samples, post digestion spiked samples and independent calibration verification standards. The uncertainty estimation was performed on U and Pu samples that have been analyzed previously as part of the U and Pu Sample Exchange Programs. Control chart results and data from the U and Pu metal exchange programs were combined with the GUM into a concentration dependent estimate of the expanded uncertainty. Comparison of trace element uncertainties obtained using this model was compared to those obtained for trace element results as part of the Exchange programs. This process was completed for all trace elements that were determined to be above the detection limit for the U and Pu samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mineral ecophysiological evidence for microbial activity in banded iron formation

The phosphorus composition of banded-iron formations (BIFs) has been used as a proxy for Precambrian seawater composition and the paleoeredox state of Earth's surface environment. However, it is unclear whether the phosphorus in BIFs originally entered the sediment as a sorbed component of the iron oxyhydroxide particles, or whether it was incorporated into the biomass of marine phytoplankton. We conducted high-resolution mineral analyses and report here the first detection of an Fe(III) acetate salt, as well as nanocrystals of apatite in association with magnetite, in the 2.48 Ga Dales Gorge Member of the Brockman Iron Formation (a BIF), Hamersley, Western Australia. The clusters of apatite are similar in size and morphology to biogenic apatite crystals resulting from biomass decay in Phanerozoic marine sediments, while the formation of an Fe(III) acetate salt and magnetite not only implies the original presence of biomass in the BIF sediments, but also that organic carbon likely served as an electron donor during bacterial Fe(III) reduction. This study is important because it suggests that phytoplankton may have played a key role in the transfer of phosphorus (and other trace elements) from the photic zone to the seafloor.

09 BIOMASS FUELS↗

Analysis of a Uranium Oxide Sample Interdicted in Slovakia (FSC 12-3-1)

We provide a concise summary of analyses of a natural uranium sample seized in Slovakia in November 2007. Results are presented for compound identification, water content, U assay, trace element abundances, trace organic compounds, isotope compositions for U, Pb, Sr and O, and age determination using the 234 U – 230 Th and 235 U – 231 Pa chronometers. The sample is a mixture of two common uranium compounds - schoepite and uraninite. The uranium isotope composition is indistinguishable from natural; 236 U was not detected. The O, Sr and Pb isotope compositions and trace element abundances are unremarkable. The 234 U – 230 Th chronometer gives an age of 15.5 years relative to the date of analysis, indicating the sample was produced in January 1997. A comparison of the data for this sample with data in the Uranium Sourcing database failed to find a match, indicating the sample was not produced at a facility represented in the database.

07 ISOTOPE AND RADIATION SOURCES↗

Potential Risks of Freshwater Aquifer Contamination with Geosequestration

Substantial leakage of CO 2 from deep geological strata to shallow potable aquifers is likely to be rare, but chemical detection of potential leakage nonetheless remains an integral component of any safe carbon capture and storage system. CO 2 that infiltrates an unconfined freshwater aquifer will have an immediate impact on water chemistry by lowering pH in most cases and by altering the concentration of total dissolved solids. Chemical signatures in affected waters provide an important opportunity for early detection of leaks. In the presence of CO 2 , trace elements such as Mn, Fe, and Ca can increase by an order of magnitude or more above control concentrations within 100 days. Therefore, these and other elements should be monitored along with pH as geochemical markers of potential CO 2 leaks. Dissolved inorganic carbon and alkalinity can also be rapidly responsive to CO 2 and are stable indicators of a leak. Importantly, such changes may be detectable long before direct changes in CO 2 are observed. The experimental results also suggest that the relative severity of the impact of leaks on overlying drinking-water aquifers should be considered in the selection of CO 2 sequestration sites. One primary selection criteria should be metal and metalloid availability, such as uranium and arsenic abundance, to carefully monitor chemical species that could trigger changes above maximum contaminant levels (MCLs). Overall, the risks of leakage from underground CO 2 storage are real but appear to be manageable if systems are closely monitored.

54 ENVIRONMENTAL SCIENCES↗

Imaging trace element distributions in single organelles and subcellular features

The distributions of chemical elements within cells are of prime importance in a wide range of basic and applied biochemical research. An example is the role of the subcellular Zn distribution in Zn homeostasis in insulin producing pancreatic beta cells and the development of type 2 diabetes mellitus. We combined transmission electron microscopy with micro- and nano-synchrotron X-ray fluorescence to image unequivocally for the first time, to the best of our knowledge, the natural elemental distributions, including those of trace elements, in single organelles and other subcellular features. Detected elements include Cl, K, Ca, Co, Ni, Cu, Zn and Cd (which some cells were supplemented with). Cell samples were prepared by a technique that minimally affects the natural elemental concentrations and distributions, and without using fluorescent indicators.We find it could likely be applied to all cell types and provide new biochemical insights at the single organelle level not available from organelle population level studies.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced Characterization of Wastewaters with a Focus on the Environment & Economics (Final Technical Progress Report)

This project, funded by the U.S. Department of Energy under award DE-FE0032457 and conducted at the University of Illinois at Urbana-Champaign, focused on advancing the characterization of coal combustion residual (CCR) effluents. The primary objectives were to develop analytical methods for detecting major cations, anions, trace metals, and rare earth elements (REEs) in CCR wastewater, assess environmental impacts, and explore opportunities for resource recovery. The project advanced the development of a "One-Shot" analysis system designed to simultaneously analyze multiple analytes in CCR effluents.

01 COAL, LIGNITE, AND PEAT↗

Low-cost, portable optical sensors for critical mineral prospecting and process monitoring

A combination of projected demand increases for economically critical minerals and a monopolistic global marketplace for these minerals has caused concern over supply chain vulnerabilities, which would impact energy, national defense, and advanced technology production. Domestic production of critical minerals is hindered by expensive and non-portable methods for analyzing metal concentration, which is vital both for resource prospecting and process monitoring. Here, a suite of luminescent materials along with portable instrumentation is presented for fluorescence-based detection of trace concentrations of critical minerals (cobalt, rare earth elements, and aluminum) as well as common gangue metals that are removed during processing (iron and aluminum). A metal-organic framework comprised of zinc, adenine, and trimesic acid immobilized on a fiber optic tip is capable of sensing part-per-billion concentrations of terbium, europium, dysprosium, and samarium through a sensitization approach, in which individual elements produce characteristic emission bands enabling multiple rare earths to be simultaneously detected and distinguished. A deep-UV light emitting diode is used as the excitation source, while a portable spectrometer is used to detect the emitted light. A similar optical set-up is coupled with two different carbon dot materials, which can detect low part-per-million concentrations of cobalt and iron in acidic environments. Metal-organic framework thin films comprised of copper and 2-aminoterephthalic acid are used in tandem with a portable optical set-up to further detect aluminum, with successful deployment in real fly ash leachates. Taken together, these technologies provide an inexpensive and sensitive path towards characterizing economically critical metals.

characterization and extraction of rare earth elem↗

Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry

In addition to serving as an f-element ligand and rare-earth method complexing agent, tributyl phosphate (TBP) is a compound containing core functional groups that mimic those routinely found in degradation products from industrial processes. Because detection of trace quantities of TBP can provide insight into the routes of contamination and degradation in the environment, there is a need to develop methods capable of detecting trace quantities of TBP. Vapor detection at atmospheric pressure is one approach that is both sensitive and rapid. We present here the use of atmospheric flow tube mass spectrometry (AFT-MS) for the ambient vapor sampling of TBP from headspace of ppb-level solutions in methanol. Gas phase clustering reactions were to enhance detection levels via the addition of small quantities of the dopants diethylamine (DEA), triethylamine (TEA), and pinacolyl methylphosphonate (PMP) in the vapor stream. Detection of the TBP vapor emanating from these solutions demonstrated a linear range for the protonated TBP species of 1-1000 ppb from solution. The clusters of TBP with DEA, TEA, and PMP each yielded linear ranges of 1-250 ppb for TBP in solution. Despite smaller linear ranges, the addition of these dopant species added a layer of analytical selectivity and reduced variability in signals from quality control samples. These data were obtained using an AFT source coupled to a linear ion trap mass spectrometer, which demonstrates the applicability of trapping systems to the AFT ionization technique while monitoring positive ions.

Ambient vapor sampling, Dielectric barrier dischar↗

Elemental analysis of different varieties of rice samples using XRF technique

Rice is most consumed staple food in the world providing over 21% of the calorie intake of world’s population having high yielding capacity. Elements detected in rice are Al, As, Br, Cd, Cl, Co, Cs, Cu, Fe, Hg, K, Mg, Mn, Mo, Rb, Se and Zn by using Instrumental Neutron Activation with k0 standardization (R. Jayasekera etal,2004). Some of these trace elements are C, H, O, N, S, Ca, P, K, Na, Cl, Mn, Ti, Mg, Cu, Fe, Ni, Si and Zn are essential for growth of human physique The deficiency or excess of these elements in food is known to cause a variety of malnutrition or health disorders in the world. Every year, various varieties of rice are launched by Punjab Agriculture University, Ludhiana. The main purpose of which is to increases the yield to attain the maximum profit. But this leads to changing the elemental concentration in them, which may affect the human health according to variation in the nutrition values. The main objective is to study the presence of elemental concentration in various varieties of rice using EDXRF technique.

60 APPLIED LIFE SCIENCES↗

Methylmercury Speciation and Retention Evaluation to Support Saltstone Waste Acceptance Criteria

Mercury is a contaminant of concern in Savannah River Site (SRS) high level waste (HLW). For five decades elemental mercury was used in the catalytic dissolution of aluminum cladding from the enrichedalloy uranium recovery process. Over 60,000 kg of mercury are now distributed in the SRS HLW tanks. The mercury speciation in the liquid waste streams resulting from conditioning HLW sludge for vitrification and in the decontaminated low activity sodium salt solution removed from the tanks was initially thought to be primarily ionic with a minor amount of elemental mercury. Recent sampling detected organic mercury, primarily methylmercury, HgCH 3 + (MeHg + ), and a trace amount of ethylmercury (EtHg) in these streams in addition to the ionic and elemental forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Utilizing rare earth elements as tracers in high TDS reservoir brines in CCS applications

In this paper we report the result of research associated with the testing of a procedures necessary for utilizing natural occurring trace elements, specifically the Rare Earth Elements (REE) as geochemical tracers in Carbon Capture and Storage (CCS) applications. Trace elements, particularly REE may be well suited to serve as in situ tracers for monitoring geochemical conditions and the migration of CO₂-charged waters within CCS storage systems. We have been conducting studies to determine the efficacy of using REE as a tracer and characterization tool in the laboratory, at a CCS analogue site in Soda Springs, Idaho, and at a proposed CCS reservoir at the Rock Springs Uplift, Wyoming. Results from field and laboratory studies have been encouraging and show that REE may be an effective tracer in CCS systems and overlying aquifers. In recent years, a series of studies using REE as a natural groundwater tracer have been conducted successfully at various locations around the globe. Additionally, REE and other trace elements have been successfully used as in situ tracers to describe the evolution of deep sedimentary Basins. Our goal has been to establish naturally occurring REE as a useful monitoring measuring and verification (MMV) tool in CCS research because formation brine chemistry will be particularly sensitive to changes in local equilibrium caused by the addition of large volumes of CO₂. Because brine within CCS target formations will have been in chemical equilibrium with the host rocks for millions of years, the addition of large volumes of CO₂ will cause reactions in the formation that will drive changes to the brine chemistry due to the pH change caused by the formation of carbonic acid. This CO₂ driven change in formation fluid chemistry will have a major impact on water rock reaction equilibrium in the formation, which will impart a change in the REE fingerprint of the brine that can measured and be used to monitor in situ reservoir conditions. Our research has shown that the REE signature imparted to the formation fluid by the introduction of CO₂ to the formation, can be measured and tracked as part of an MMV program. Additionally, this REE fingerprint may serve as an ideal tracer for fluid migration, both within the CCS target formation, and should formation fluids migrate into overlying aquifers. However application of REE and other trace elements to CCS system is complicated by the high salt content of the brines contained within the target formations. In the United States by regulation, in order for a geologic reservoir to be considered suitable for carbon storage, it must contain formation brine with total dissolved solids (TDS) > 10,000 ppm, and in most cases formation brines have TDS well in excess of that threshold. The high salinity of these brines creates analytical problems for elemental analysis, including element interference with trace metals in Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) (i.e. element mass overlap due to oxide or plasma phenomenon). Additionally, instruments like the ICP-MS that are sensitive enough to measure trace elements down to the parts per trillion level are quickly oversaturated when water TDS exceeds much more than 1,000 ppm. Normally this problem is dealt with through dilution of the sample, bringing the water chemistry into the instruments working range. However, dilution is not an option when analyzing these formation brines for trace metals, because trace elements, specifically the REE, which occur in aqueous solutions at the parts per trillion levels. Any dilution of the sample would make REE detection impossible. Therefore, the ability to use trace metals as in situ natural tracers in high TDS brines environments requires the development of methods for pre-concentrating trace elements, while reducing the salinity and associated elemental interference such that the brines can be routinely analyzed by standard ICP-MS methods. As part of the Big Sky Carbon Sequestration Project the INL-CAES has developed a rapid, easy to use process that pre-concentrates trace metals, including REE, up to 100x while eliminating interfering ions (e.g. Ba, Cl). The process is straightforward, inexpensive, and requires little infrastructure, using only a single chromatography column with inexpensive, reusable, commercially available resins and wash chemicals. The procedure has been tested with synthetic brines (215,000 ppm or less TDS) and field water samples (up to 5,000 ppm TDS). Testing has produced data of high quality with REE capture efficiency exceeding 95%, while reducing interfering elements by > 99%.

54 ENVIRONMENTAL SCIENCES↗

Nanosecond Nd-YAG laser induced plasma emission characteristics in low pressure CO{sub 2} ambient gas for spectrochemical application on Mars

An experimental study is conducted on the possibility and viability of performing spectrochemical analysis of carbon and other elements in trace amount in Mars, in particular, the clean detection of C, which is indispensible for tracking the sign of life in Mars. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from a pure copper target in CO{sub 2} ambient gas of reduced pressure simulating the atmospheric condition of Mars. It is shown that the same shock wave excitation mechanism also works this case while exhibiting remarkably long cooling stage. The highest Cu emission intensities induced by 4 mJ laser ablation energy is attained in 600 Pa CO{sub 2} ambient gas. Meanwhile the considerably weaker carbon emission from the CO{sub 2} gas appears relatively featureless over the entire range of pressure variation, posing a serious problem for sensitive trace analysis of C contained in a solid sample. Our time resolved intensity measurement nevertheless reveals earlier appearance of C emission from the CO{sub 2} gas with a limited duration from 50 ns to 400 ns after the laser irradiation, well before the initial appearance of the long lasting C emission from the solid target at about 1 μs, due to the different C-releasing processes from their different host materials. The unwanted C emission from the ambient gas can thus be eliminated from the detected spectrum by a proper time gated detection window. The excellent spectra of carbon, aluminum, calcium, sodium, hydrogen, and oxygen obtained from an agate sample are presented to further demonstrate and verify merit of this special time gated LIBS using CO{sub 2} ambient gas and suggesting its viability for broad ranging in-situ applications in Mars.