Search NASA⌕ Search

SEARCH · Search NASA

Results for “trajectory calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Constraining hydrodynamic models of inertial confinement fusion implosions using capsule surrogate experiments

We conduct capsule surrogate experiments at the National Ignition Facility to calibrate radiation hydrodynamic simulations to infer hydrodynamic conditions that are not observable in indirect drive ignition implosions. We tune the simulations by applying laser power and cross beam energy transfer (CBET) saturation multipliers to match the observables from capsule surrogate experiments. Shock timing, velocity, and symmetry are measured in liquid D 2 filled Keyhole capsule surrogate experiments and implosion trajectory, stagnation time, and shape time history are measured in in-flight 2D backlit x-ray radiography experiments (“2DConA”) of D 2 gas filled capsule implosions. Calibrated simulations suggest that the N210808 ignition implosion (fusion target gain = 0.7) had a shell mass remaining at stagnation of less than the nominal %5 (3.8%) and resulted in less confinement. For N221204, the shell was made 5.75 μm thicker to trade implosion velocity for increased confinement and resulted in a target gain = 1.5 with a shell mass remaining of 5.7%. Furthermore, a single adjusted model can reproduce all shock timing data as changes are made to shell thickness (79–85 μm) and laser wavelength separation (1.8–4.0 Å). However, for the 2DConA implosions, a 5% variation in the peak power laser multipliers and a 30% variation in late-time CBET between experiments are needed to match the observed stagnation times, in-flight $P_2$ shape, and hot-spot $P_2$ shape. While progress is being made to improve the models in simulations using focused experiments, capsule surrogate experiments will continue to be needed to optimize future ignition designs.

Lasers↗

A variational phase-field model For ductile fracture with coalescence dissipation

A novel phase-field model for ductile fracture is presented. The model is developed within a consistent variational framework in the context of finite-deformation kinematics. A novel coalescence dissipation introduces a new coupling mechanism between plasticity and fracture by degrading the fracture toughness as the equivalent plastic strain increases. The proposed model is compared with a recent alternative where plasticity and fracture are strongly coupled. Several representative numerical examples motivate specific modeling choices. In particular, a linear crack geometric function provides an “unperturbed” ductile response prior to crack initiation, and Lorentz-type degradation functions ensure that the critical fracture strength remains independent of the phase-field regularization length. In addition, the response of the model is demonstrated to converge with a vanishing phase-field regularization length. Additionally, the model is then applied to calibrate and simulate a three-point bending experiment of an aluminum alloy specimen with a complex geometry. The effect of the proposed coalescence dissipation coupling on simulations of the experiment is first investigated in a two-dimensional plane strain setting. The calibrated model is then applied to a three-dimensional calculation, where the calculated load-deflection curves and the crack trajectory show excellent agreement with experimental observations. Finally, the model is applied to simulate crack nucleation and growth in a specimen from a recent Sandia Fracture Challenge.

42 ENGINEERING↗

Tracker Fits for shot 1s1674

Gas gun shock-to-detonation experiments provide data for calibrating HE burn models. At LANL the principal diagnostic is a magnetic gauge package that provides data on the lead shock trajectory, which is used to determine the run-distance to detonation, and the lead shock speed with run distance, which together with jump-off velocity of the velocity gauges determines Hugoniot locus points for the reactants.

42 ENGINEERING↗

Correction and calibration of atmospheric impact observations in GOES GLM data

The Earth's atmosphere is impacted daily by both meteoroids and artificial objects. Calibrated observations of the emitted light at sufficiently high sampling rates can enable or improve the estimation of impactor attributes such as size, cohesion, trajectory, and composition, but are difficult to obtain owing to the unpredictability, brevity, and high dynamic (brightness) range of impacts. Ground-based camera systems have successfully monitored small regions of the atmosphere at video frame rates and with limited radiometric capabilities, but most impacts occur over the 70% of the Earth's surface covered by water and are therefore missed by these networks. The Geostationary Lightning Mapper (GLM) instruments aboard Geostationary Operational Environmental Satellites 16 and 17 provide near-hemispherical coverage at 500 frames per second. These data have been shown to contain the signatures of many independently confirmed impacts, often from both viewing angles simultaneously, and constitute an observational resource that is currently unparalleled in the public domain. NASA's Asteroid Threat Assessment Project has implemented an automated impact detection pipeline that processes data from GLM daily. Given a detected impact, the GLM data contain a wealth of information for use in quantitative follow-up analyses. However, impact events differ from lightning in ways that violate key assumptions built into GLM's design. The result is that GLM's onboard processing introduces errors into pixel observations of impact events and the calibrated energies near the periphery of the detector may be substantially overestimated. We present methods for mitigating these and other issues to produce a data product more suitable for impact analyses than the existing GLM lightning product.

58 GEOSCIENCES↗

Measurement of space charge effects and energy calibration in ProtoDUNE-SP

The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018.The accumulation of positive ions in a LArTPC located on the surface can distort the electric field and the reconstructed particle trajectories. It is critical to understand and correct for the space charge effects in order to achieve the desired spatial and calorimetric resolutions in the LArTPC. This talk will present the measurement of space charge effects and the calorimetric measurements of the detector in ProtoDUNE-SP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Refined interpretation of electron temperature response to neutral beam injection at DIII-D

Accurate particle and power deposition profiles of neutral beam injection (NBI) are essential to transport studies, and that information is usually acquired through Monte Carlo simulations with a given collisional model. The deposition process of the energetic beam particles leads to the informative electron temperature (T e ) evolution trajectory, which can be captured by electron cyclotron emission (ECE) system due to its good spatial and temporal resolution. Previously, some work has been done to interpret the T e responses to the pulsed NBI as a linear heating source with Fourier-based techniques, although that approach fell short when the fast ion slowing-down time becomes significant (~100 ms). It has been observed in DIII-D that the modulated NBI pulses (10–50 Hz) reduce local core T e values ~0.1 keV through cold electron dilution in high-T e (>2 keV) plasmas alongside accumulative heating. Here, a novel approach to interpret the T e response to NBI was developed by linearizing and modeling the detailed T e evolution trajectory using coherently averaged ECE data based on the different time scales of the terms in the local power and particle balance equations. The technique does not require absolute calibrations of ECE and is independent of collisional models. The resulting beam deposition profiles show good consistency and reasonable agreement with Monte Carlo calculations based on the atomic data from the Atomic Data and Analysis Structure (ADAS). Local electron density response measured by Thomson scattering (TS) also suggests the same features when the beam pulse is large enough for that diagnostic to resolve. The remaining discrepancies are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model for the curvature response of the CDF II drift chamber

The CDF II experiment at the Fermilab Tevatron used a drift chamber to measure the momenta of charged particles. We present a model for the response of the drift chamber to the curvature of a charged particle's trajectory. Constraints on the model parameters are obtained from cosmic-ray data and from information published by CDF in the context of the W boson mass measurement. Implications for the calibration of the drift chamber measurement of momentum are discussed. The robustness of the CDF calibration procedure is demonstrated. The model provides a framework for the analysis of precision magnetic trackers of high-momentum particles. Published by the American Physical Society 2025

47 OTHER INSTRUMENTATION↗

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive compartmental model and calibration algorithm for the study of clinical implications of the population-level spread of COVID-19: a study protocol

The complex dynamics of the coronavirus disease 2019 (COVID-19) pandemic has made obtaining reliable long-term forecasts of the disease progression difficult. Simple mechanistic models with deterministic parameters are useful for short-term predictions but have ultimately been unsuccessful in extrapolating the trajectory of the pandemic because of unmodelled dynamics and the unrealistic level of certainty that is assumed in the predictions. We propose a 22-compartment epidemiological model that includes compartments not previously considered concurrently, to account for the effects of vaccination, asymptomatic individuals, inadequate access to hospital care, post-acute COVID-19 and recovery with long-term health complications. Additionally, new connections between compartments introduce new dynamics to the system and provide a framework to study the sensitivity of model outputs to several concurrent effects, including temporary immunity, vaccination rate and vaccine effectiveness. Subject to data availability for a given region, we discuss a means by which population demographics (age, comorbidity, socioeconomic status, sex and geographical location) and clinically relevant information (different variants, different vaccines) can be incorporated within the 22-compartment framework. Considering a probabilistic interpretation of the parameters allows the model's predictions to reflect the current state of uncertainty about the model parameters and model states. We propose the use of a sparse Bayesian learning algorithm for parameter calibration and model selection. This methodology considers a combination of prescribed parameter prior distributions for parameters that are known to be essential to the modelled dynamics and automatic relevance determination priors for parameters whose relevance is questionable. This is useful as it helps prevent overfitting the available epidemiological data when calibrating the parameters of the proposed model. Population-level administrative health data will serve as partial observations of the model states.

59 BASIC BIOLOGICAL SCIENCES↗

Seasonal calibration of the end-cretaceous Chicxulub impact event

The end-Cretaceous Chicxulub impact triggered Earth’s last mass-extinction, extinguishing ~ 75% of species diversity and facilitating a global ecological shift to mammal-dominated biomes. Temporal details of the impact event on a fine scale (hour-to-day), important to understanding the early trajectory of mass-extinction, have largely eluded previous studies. This study employs histological and histo-isotopic analyses of fossil fish that were coeval with a unique impact-triggered mass-death assemblage from the Cretaceous-Paleogene (KPg) boundary in North Dakota (USA). Patterns of growth history, including periodicity of δ 18 O and δ 13 C and growth band morphology, plus corroborating data from fish ontogeny and seasonal insect behavior, reveal that the impact occurred during boreal Spring/Summer, shortly after the spawning season for fish and most continental taxa. The severity and taxonomic symmetry of response to global natural hazards are influenced by the season during which they occur, suggesting that post-impact perturbations could have exerted a selective force that was exacerbated by seasonal timing. Data from this study can also provide vital hindsight into patterns of extant biotic response to global-scale hazards that are relevant to both current and future biomes.

54 ENVIRONMENTAL SCIENCES↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In situ estimation of ice crystal properties at the South Pole using LED calibration data from the IceCube Neutrino Observatory

The IceCube Neutrino Observatory instruments about 1 km 3 of deep, glacial ice at the geographic South Pole. It uses 5160 photomultipliers to detect Cherenkov light emitted by charged relativistic particles. An unexpected light propagation effect observed by the experiment is an anisotropic attenuation, which is aligned with the local flow direction of the ice. We examine birefringent light propagation through the polycrystalline ice microstructure as a possible explanation for this effect. The predictions of a first-principles model developed for this purpose, in particular curved light trajectories resulting from asymmetric diffusion, provide a qualitatively good match to the main features of the data. This in turn allows us to deduce ice crystal properties. Since the wavelength of the detected light is short compared to the crystal size, these crystal properties include not only the crystal orientation fabric, but also the average crystal size and shape, as a function of depth. By adding small empirical corrections to this first-principles model, a quantitatively accurate description of the optical properties of the IceCube glacial ice is obtained. In this paper, we present the experimental signature of ice optical anisotropy observed in IceCube light-emitting diode (LED) calibration data, the theory and parameterization of the birefringence effect, the fitting procedures of these parameterizations to experimental data, and the inferred crystal properties.

54 ENVIRONMENTAL SCIENCES↗

Comparing Measured Driver Behavior Distributions to Results from Car-Following Models using SUMO and Real-World Vehicle Trajectories from Radar: SUMO Default vs. Radar-Measured CF model Parameters

In this study, the physical principles governing car-following (CF) behavior and their impact on traffic flow at signalized intersections are investigated. High temporal-resolution radar data is used to provide valuable insights into actual CF behavior, including acceleration, deceleration, and time headway distribution. Demand-calibrated SUMO simulations are run using empirical CF parameter distributions, and three CF models are evaluated: IDM, EIDM, and Krauss. By emulating radar data in SUMO and processing simulated vehicle traces, discrepancies between empirical and simulated parameter distributions are identified. Further analysis includes comparisons with default SUMO CF model parameters. The findings reveal that measured accelerations differ from CF model parameter accelerations and using the empirical value ($\mu = 0.89m/s^2$) leads to unrealistic simulations that fail volume-based calibration. Default parameters for all three models reasonably approximate the mean and median of measured parameters, but fail to capture the true distribution shape, partly due to homogeneity when using default parameters. The results show that it is more effective to simulate with the default parameters provided by SUMO rather than using measurements of real-world distributions without additional calibration. Future work will investigate closing the loop between the measured real-world and SUMO distributions using traditional calibration tactics, as well as assess the impact of calibrated vs. default CF parameters on simulation outputs like fuel consumption.

Schrader, Max (ORCID:0000000336737672)↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling root system growth around obstacles

State-of-the-Art models of Root System Architecture (RSA) do not allow simulating root growth around rigid obstacles. Yet, the presence of obstacles can be highly disruptive to the root system. We grew wheat seedlings in sealed petri dishes without obstacle and in custom 3D-printed rhizoboxes containing obstacles. Time-lapse photography was used to reconstruct the wheat root morphology network. We used the reconstructed wheat root network without obstacle to calibrate an RSA model implemented in the R-SWMS software. The root network with obstacles allowed calibrating the parameters of a new function that models the influence of rigid obstacles on wheat root growth. Experimental results show that the presence of a rigid obstacle does not affect the growth rate of the wheat root axes, but that it does influence the root trajectory after the main axis has passed the obstacle. The growth recovery time, i.e. the time for the main root axis to recover its geotropism-driven growth, is proportional to the time during which the main axis grows along the obstacle. Qualitative and quantitative comparisons between experimental and numerical results show that the proposed model successfully simulates wheat RSA growth around obstacles. Our results suggest that wheat roots follow patterns that could inspire the design of adaptive engineering flow networks.

59 BASIC BIOLOGICAL SCIENCES↗

In-situ spectroscopic ellipsometry for real-time characterization of the effects of high-flux helium plasmas on tungsten surfaces

Tungsten samples were exposed to He plasmas generated by an RF source (Γ i = 3.5 x 10 16 He cm -2 s -1 , ion energy = 92 eV.) The range of exposure conditions selected here is conducive to the growth of nearsurface He bubbles, and at higher fluence, the formation of W nanotendrils ranging between 50 — 100 nm in diameter. The evolution of these surface features was probed using a fixed-angle ellipsometer (280 — 1000 nm wavelength range) with direct line-of-sight to the sample. Over the parameter space explored here, changes in the two angles (p, S) that define the polarization of the reflected light followed a distinct trajectory with increasing plasma fluence. Ex-situ ellipsometry of 22 additional tungsten specimens tested at a wide range of plasma fluences and temperatures mapped onto these in-situ results well. We used helium ion microscopy and focused ion beam profiling to provide a direct calibration of the ellipsometry measurements. Our results indicate that for a reproducible process such as the growth helium-induced surface morphologies, ellipsometry is a practical in-situ diagnostic to study how fusion plasmas modify materials. To study more general effects of plasmas on surfaces, including co-deposition and sputtering, different approaches to modelling the optical properties of the exposed surfaces are also considered.

36 MATERIALS SCIENCE↗