Search NASA⌕ Search

SEARCH · Search NASA

Results for “transformer windings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Voltage Regulator for a dc-to-dc Converter

New voltage regulator isolates signals from power-switching converter without use of complex circuitry or optical couplers. Only addition is extra secondary winding on existing interstage transformer. Error signals shortcircuit new winding and inhibit converter action. Resistor in series with primary winding limits short-circuit current to prevent damage to circuit components. Extra transformer winding eliminates need for isolation components.

Mclyman, C. W.↗

High Power Amplifier and Power Supply

A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.

Duong, Johnny↗

Buck/boost regulator

A voltage regulated DC to DC converter uses an inductor and a capacitor as storage elements. The inductor is composed of two windings having a common junction. A transformer with a center tap connected to the common junction of the two windings is connected at either end of its winding to ground through controlled switches. One winding of the inductor and either end of the transformer winding are connected by power diodes to the capacitor which supplies the output voltage to a load. The other winding of the inductor is connected to a fourth power diode as a clamping diode. Input voltage is supplied to the inductor through a third controlled switch. A pulse width modulator connected to the output of the converter alternately closes and opens the switches connected to either end of the transformer winding and also closes the switch supplying input voltage to the inductor each time either of the switches connected to the ends of the transformer winding are closed. The duty cycle of the closing and opening of the several switches is adjusted by the pulse modulator to regulate the output voltage.

Paulkovich, J.↗

Direct-Current Monitor With Flux-Reset Transformer Coupling

Circuit measures constant or slowly-varying unidirectional electrical current using flux-reset transformer coupling. Measurement nonintrusive in sense that no need for direct contact with wire that carries load current to be measured, and no need to install series resistive element in load-current path. Toroidal magnetic core wrapped with coil of wire placed around load-current-carrying wire, acts as transformer core, load-current-carrying wire acts as primary winding of transformer, and coil wrapped on core acts as secondary winding.

Canter, Stanley↗

A study of eddy-induced fluctuations of the zonal-mean wind using conventional and transformed Eulerian diagnostics

The dynamics of eddy-induced fluctuations of the zonal-mean current in the troposphere and lower stratosphere is investigated using conventional and transformed Eulerian diagnostics utilizing ECMWF FGGE IIIb data. The results obtained support the notion that large convergences of the vertical component of the Eliassen-Palm flux in the middle troposphere at mid- to high-latitudes have much less effect on zonal-mean angular momentum fluctuations than do small divergences of the horizontal component at lower latitudes and higher altitudes.

Pfeffer, Richard L.↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Conversion of magnetic field energy into kinetic energy in the solar wind

The outflow of the solar magnetic field energy (the radial component of the Poynting vector) per steradian is inversely proportional to the solar wind velocity. It is a decreasing function of the heliocentric distance. When the magnetic field effect is included in the one-fluid model of the solar wind, the transformation of magnetic field energy into kinetic energy during the expansion process increases the solar wind velocity at 1 AU by 17 percent.

Whang, Y. C.↗

Split Coil Forms for Rotary Transformers

Split cores for rotor and stator windings of rotary transformer mounted around their respective coils (which are in bobbins) and cemented together. This arrangement simplifies winding of stator coil to go in a slot in inner diameter of stator coil. One practical application of rotary transformers fabricated according to this technique is for centrifuges, in which conventional sliprings are of uncertain reliability.

Mclyman, C. W. T.↗

Magnetic cores with high reluctance differences in flux paths

Embodiment of the present invention includes a magnetic structure and a magnetic structure used in a direct current (DC) to DC energy converter. The magnetic structure has an E-core and a plate, with the plate positioned in contact or in near contact with the post surfaces of the E-core. The E-core has a base, a no-winding leg, a transformer leg, and an inductor leg. The no-winding leg, the transformer leg, and the inductor leg are perpendicular and magnetically in contact with the base. The plate is a flat slab with lateral dimensions generally larger than its thickness. The plate has a plate nose that overlaps a top no-winding leg surface of the no-winding leg with a no-winding gap area to form a no-winding gap with a no-winding gap reluctance. The plate also has a plate end that overlaps a top inductor leg surface of the inductor leg with an inductor gap area to form an inductor gap with an inductor gap reluctance. In some embodiments, e.g., where the duty cycle is less than 50 percent, the inductor gap reluctance will be designed to be less than the no-winding gap reluctance. In these cases, the majority of the magnetic flux that passes through the transformer leg will return through the inductor leg, instead of through the no-winding leg. The inductor and no-winding gap reluctances can he adjusted, so that the electromotive force applied to a charge passing through the inductor will partially cancel the electromotive force applied by the transformer secondary. The gap reluctance ratio can be defined, so that the difference in secondary and inductor electromotive forces is equal to the output voltage defined by an optimal no-ripple duty cycle. In this way no changing current is required through the inductor to create a dI/dt inductive voltage drop across the output inductor. Zero output current ripple is achieved.Various embodiments of the plate, plate shape, and no-winding leg are disclosed. These embodiments allow achieving a high ratio of no-winding gap reluctance to inductor gap reluctance, for practical, affordable magnetic material structures and aspect ratios. A high gap reluctance ratio enables zero output current ripple for the high transformer turns ratios that are needed to achieve high input to output voltage ratios. The embodiments therefore allow achieving low output current ripple for 48 V or higher input voltages, 1 V or lower output voltages, and high output currents.

Yao, Yuan↗

Land Resources for Wind Energy Development Requires Regionalized Characterizations

Estimates of the land area occupied by wind energy differ by orders of magnitude due to data scarcity and inconsistent methodology. Here, we developed a method that combines machine learning-based imagery analysis and geographic information systems and examined the land area of 318 wind farms (15,871 turbines) in the U.S. portion of the Western Interconnection. We found that prior land use and human modification in the project area are critical for land-use efficiency and land transformation of wind projects. Projects developed in areas with little human modification have a land-use efficiency of 63.8 ± 8.9 W/m 2 (mean ±95% confidence interval) and a land transformation of 0.24 ± 0.07 m 2 /MWh, while values for projects in areas with high human modification are 447 ± 49.4 W/m 2 and 0.05 ± 0.01 m 2 /MWh, respectively. We show that land resources for wind can be quantified consistently with our replicable method, a method that obviates >99% of the workload using machine learning. To quantify the peripheral impact of a turbine, buffered geometry can be used as a proxy for measuring land resources and metrics when a large enough impact radius is assumed (e.g., >4 times the rotor diameter). Our analysis provides a necessary first step toward regionalized impact assessment and improved comparisons of energy alternatives.

17 WIND ENERGY↗

Cloud-drift wind estimates during PGGE

Cloud drift winds constitute an important component of the First Global Atmospheric Research Program Experiment data base. Data was generated by far different centers, using somewhat different procedures. Image data transformation to wind vectors is discussed. Emphasis is placed on the differences between the processing techniques employed in each system. The use of cloud drift data by global data assimulation systems is reviewed, including quality control and relative weighting.

Mcpherson, R. D.↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stratospheric Horizontal Wavenumber Spectra of Winds, Potential Temperature, and Atmospheric Tracers Observed by High-Altitude Aircraft

Horizontal wavenumber power spectra of vertical and horizontal wind velocities, potential temperatures, and ozone and N(2)O mixing ratios, as measured in the mid-stratosphere during 73 ER-2 flights (altitude approx. 20km) are presented. The velocity and potential temperature spectra in the 100 to 1-km wavelength range deviate significantly from the uniform -5/3 power law expected for the inverse energy-cascade regime of two-dimensional turbulence and also for inertial-range, three-dimensional turbulence. Instead, steeper spectra approximately consistent with a -3 power law are observed at horizontal scales smaller than 3 km for all velocity components as well as potential temperature. Shallower spectra are observed at scales longer than 6 km. For horizontal velocity and potential temperature the spectral indices at longer scales are between -1.5 and -2.0. For vertical velocity the spectrum at longer scales become flat. It is argued that the observed velocity and potential temperature spectra are consistent with gravity waves. At smaller scales, the shapes are also superficially consistent with a Lumley-Shur-Weinstock buoyant subrange of turbulence and/or nonlinear gravity waves. Contemporaneous spectra of ozone and N(sub 2)O mixing ratio in the 100 to 1-km wavelength range do conform to an approximately uniform -5/3 power law. It is argued that this may reflect interactions between gravity wave air-parcel displacements and laminar or filamentary structures in the trace gas mixing ratio field produced by enstropy-cascading two-dimensional turbulence.

TRACE GAS MIXING RATIO FIELDS↗

Percolation effect in thick film superconductors: Using a Bi(Pb)SrCaCuO based paste to prepare a superconducting planar transformer

A thick film superconductor paste has been developed to study the properties of granulated superconductor materials, to observe the percolation effect and to confirm the theory of the conducting mechanism in the superconducting thick films. This paste was also applied to make a superconducting planar transformer. Due to the T(sub c) and advantageous current density properties the base of the past was chosen to be of Bi(Pb)SrCaCu) system. For contacts a conventional Ag/Pt paste was used. The critical temperature of the samples were between 110 K and 115 K depending on the printed layer thickness. The critical current density -at the boiling temperature of the liquid He- was between 200 - 300 A/sq cm. The R(T) and V(I) functions were measured with different parameters. The results of the measurements have confirmed the theory of conducting mechanism in the material. The percolation structure model has been built and described. As an application, a superconducting planar thick film transformer was planned and produced. Ten windings of the transformer were printed on one side of the alumina substrate and one winding was printed on the other side. The coupling between the two sides was possible through the substrate. The samples did not need special drying and firing parameters. After the preparation, the properties of the transformer were measured. The efficiency ans the losses were determined. Finally, some fundamental advantages and problems of the process were discussed.

Sali, Robert↗

Asymmetric Switching For A PWM H-Bridge Power Circuit

Only two of four switches interrupt substantial current. An asymmetric timing scheme improves design and operation of pulse-width-modulation (PWM) H-bridge switch-and-transformer circuit. Circuit part of dc-to-dc converter or dc-to-ac inverter; in either case, output current or voltage regulated by adjusting times of opening and closing of semiconductor switches 1 through 4 to adjust durations of current pulses in primary winding of transformer.

Wong, See-Pok↗