Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance characteristics of a thermal energy storage module - A transient PCM/forced convection conjugate analysis

The performance of a thermal energy storage module is simulated numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid with low Prandtl numbers are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. The numerical results show that module geometry is crucial to the design of a space-based thermal energy storage system.

Cao, Y.↗

Transient Thermal Model and Analysis of the Lunar Surface and Regolith for Cryogenic Fluid Storage

A transient thermal model of the lunar surface and regolith was developed along with analytical techniques which will be used to evaluate the storage of cryogenic fluids at equatorial and polar landing sites. The model can provide lunar surface and subsurface temperatures as a function of latitude and time throughout the lunar cycle and season. It also accounts for the presence of or lack of the undisturbed fluff layer on the lunar surface. The model was validated with Apollo 15 and Clementine data and shows good agreement with other analytical models.

Christie, Robert J.↗

Transient analysis of a thermal storage unit involving a phase change material

The transient response of a single cell of a typical phase change material type thermal capacitor has been modeled using numerical conductive heat transfer techniques. The cell consists of a base plate, an insulated top, and two vertical walls (fins) forming a two-dimensional cavity filled with a phase change material. Both explicit and implicit numerical formulations are outlined. A mixed explicit-implicit scheme which treats the fin implicity while treating the phase change material explicitly is discussed. A band algorithmic scheme is used to reduce computer storage requirements for the implicit approach while retaining a relatively fine grid. All formulations are presented in dimensionless form thereby enabling application to geometrically similar problems. Typical parametric results are graphically presented for the case of melting with constant heat input to the base of the cell.

Griggs, E. I.↗

A PCM/forced convection conjugate transient analysis of energy storage systems with annular and countercurrent flows

Latent heat energy storage systems with both annular and countercurrent flows are modeled numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. It is found that the energy storage system with the countercurrent flow is an efficient way to absorb heat energy in a short period for pulsed power load space applications.

Cao, Y.↗

Transient Physical Modelling for the Coupling of a High Temperature Gas Reactor with Thermal Energy Storage

Improving the flexibility of nuclear reactors to meet fluctuating demand on grids with high renewable energy generation penetration is key to improving reactor economics. Economic optimization using the code HERON gives maximum profit of coupling high temperature gas reactors (HTGRs) to thermal energy storage (TES) systems in the configuration shown in Figure 1 when following the demand in Figure 3. We look to model the physics of operation for a HTGR-TES using the HYBRID library in the code Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal buffering of receivers for parabolic dish solar thermal power plants

A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.

Manvi, R.↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗

Hydrogen Recombiner Catalyst Evaluations for Waste Storage

Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.

Tener, Zachary P. [Savannah River National Laborat↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tropopause Laminar Cirrus and Its Role in the Lower Stratosphere Total Water Budget

Laminar cirrus are thin, extensive, isolated layers of ice clouds frequently observed in the tropical tropopause layer. Widespread laminar cirrus significantly affects tropical tropopause layer total water and thermal budget. In this study, we extract laminar cirrus from the Cloud‐Aerosol Lidar with Orthogonal Polarization Level 1 attenuated total backscatter images for January 2009, in order to characterize statistical properties of laminar cirrus cloud length, base, thickness, optical depth, and layer partial ice water path. These characteristics are used to develop an algorithm identifying laminar cirrus automatically from the Cloud‐Aerosol Lidar with Orthogonal Polarization Level 2 layer product for 2008–2017. The nearly 10‐year records reveal that tropopause laminar cirrus occurrence (30–40% of total cirrus) is strongly anticorrelated with the tropopause temperatures in that colder tropopause in frequent (super)saturation during boreal winter favors in situ formation of clouds. Interannually, anomalously warmer troposphere temperature (ΔT), easterly shear of the quasi‐biennial oscillation, and stronger upwelling branch of the Brewer‐Dobson circulation enhance laminar cirrus formation via cooling of the tropopause. The tropopause laminar cirrus carries ~0.05 mg/m(exp 3) (~0.5 ppmv) of ice water content during boreal winter and <0.01 mg/m(exp 3) during summer, which is anticorrelated with the seasonal variations of water vapor (H2O) observed by the Microwave Lime Sounder, indicating a temperature‐regulated partition between vapor and ice. Interannually, in cirrus‐rich region 1 ppmv decrease in H2O corresponds to 0.2–0.3 ppmv increase in ice water content. Frequently situated in (super)saturated air, tropopause laminar cirrus are likely to survive multiple lifecycles of the sublimation‐deposition processes, and may contribute up to 10% to the total water budget in the lower stratosphere. Satellites constantly observe thin, isolated, extensive layer of cirrus around the tropopause. The so‐called “laminar” cirrus occurrence and their ice amount are strongly regulated by temperature, such that colder temperatures favor more frequent (super)saturation, which results in more frequent laminar cirrus with more ice amount and therefore less water vapor. In this study we analyze laminar cirrus and water vapor from the Cloud‐Aerosol Lidar with Orthogonal Polarization and Microwave Lime Sounder observations, and hypothesize that laminar cirrus could act as an important transient water storage and contribute to the total water budget in the lower stratosphere.

Tao Wang↗

Development of Methane Emissions Model to Assess Fuel Recovery Potential at Gas Well Sites Using On Site Compression

The U.S. natural gas production and consumption has increased 85.5% since 2005 primarily due to the unconventional production methods of horizontal drilling and hydraulic fracturing. Natural gas used as a fuel has a lower greenhouse gas (GHG) footprint than coal and petroleum due to lower Carbon Dioxide (CO2) emissions when combusted. However, the “greener” benefit to natural gas may be negated by leaks in production and transmission systems. Methane (CH4), the primary hydrocarbon in natural gas, has an estimated Global Warming Potential (GWP) of 28-36 over 100 years, meaning it can absorb 28-36 more energy than CO2 which has a GWP of 1.0. Natural gas well sites are prone to methane emissions, or leaks and irregular gas releases, vented to atmosphere throughout production and transmission. The U.S. Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) has recently granted West Virginia University (WVU) funding under agreement DE-FOA-0002005, to “Advance technologies to mitigate methane emissions and increase the efficiency of the natural gas transportation infrastructure”. As part of this funding WVU was tasked with identifying and quantifying sources of methane emissions at unconventional well sites, processing this data, and developing a system to recapture these emissions. A 0-D Simulink model was developed, utilizing standardized methodologies, data from previously conducted studies, as well as collected data from well sites in the Marcellus shale play region. The model was developed to predict emission rates from various components at natural gas well sites as well as the potential to utilize these emissions as fuel for the natural gas powered compressor engines on-site. This model was utilized to run high, medium, and low cases for four identified emission sources, engine size, pneumatic controller count, liquid level production which dictates tank emissions, and compressor packing vent emissions. Due to discrepancies in transient tank emission data, a high and low emission factor for tanks was used, resulting in two sets of 81 executed cases, and 162 unique cases of total site emissions and potential for fuel consumption. Each of the cases were run over 86,400 seconds at a 1 Hz, representative of a full 24 hour day of operation. The fuel consumption offset an average of 557% of fuel consumption on an energy density basis across all 81 cases with the high tank emission factor with a maximum offset of 2334%. The fuel consumption offset was an average of 82.9% for all 81 cases with the low tank emission factor with a maximum offset of 337%. This study highlights flaws in the use of publicly available methane number calculations to determine natural gas’s suitability as an engine fuel as well as the lack of public data for transient liquid storage tank emissions.

03 NATURAL GAS↗

Design tool for estimating metal hydride storage system characteristics for light-duty hydrogen fuel cell vehicles

The U.S. Department of Energy (DOE) has developed the Framework model to simulate fuel cell-based light-duty vehicle operation for various hydrogen storage systems. This transient model simulates the performance of the storage system, fuel cell, and vehicle for comparison to DOE's Technical Targets using four drive cycles. Metal hydride hydrogen storage models have been developed for the Framework model. Despite the utility of this model, it requires that material researchers input system design specifications that cannot be easily estimated. To confront this challenge, a design tool has been developed that allows researchers to directly enter physical and thermodynamic metal hydride properties into a simple sizing module that then estimates the systems parameters required to run the storage system model. This design tool can also be used as a standalone MS Excel model to estimate the storage system mass and volume outside of Framework and compare it to the DOE Technical Targets. This model will be explained and exercised with existing hydrogen storage materials.

33 ADVANCED PROPULSION SYSTEMS↗