Search NASA⌕ Search

SEARCH · Search NASA

Results for “uncooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pyroelectric Materials for Uncooled Infrared Detectors: Processing, Properties, and Applications

Uncooled pyroelectric detectors find applications in diverse and wide areas such as industrial production; automotive; aerospace applications for satellite-borne ozone sensors assembled with an infrared spectrometer; health care; space exploration; imaging systems for ships, cars, and aircraft; and military and security surveillance systems. These detectors are the prime candidates for NASA s thermal infrared detector requirements. In this Technical Memorandum, the physical phenomena underlying the operation and advantages of pyroelectric infrared detectors is introduced. A list and applications of important ferroelectrics is given, which is a subclass of pyroelectrics. The basic concepts of processing of important pyroelectrics in various forms are described: single crystal growth, ceramic processing, polymer-composites preparation, and thin- and thick-film fabrications. The present status of materials and their characteristics and detectors figures-of-merit are presented in detail. In the end, the unique techniques demonstrated for improving/enhancing the performance of pyroelectric detectors are illustrated. Emphasis is placed on recent advances and emerging technologies such as thin-film array devices and novel single crystal sensors.

Aggarwal, M. D.↗

Cloud Optical Depth Measured with Ground-Based, Uncooled Infrared Imagers

Recent advances in uncooled, low-cost, long-wave infrared imagers provide excellent opportunities for remotely deployed ground-based remote sensing systems. However, the use of these imagers in demanding atmospheric sensing applications requires that careful attention be paid to characterizing and calibrating the system. We have developed and are using several versions of the ground-based "Infrared Cloud Imager (ICI)" instrument to measure spatial and temporal statistics of clouds and cloud optical depth or attenuation for both climate research and Earth-space optical communications path characterization. In this paper we summarize the ICI instruments and calibration methodology, then show ICI-derived cloud optical depths that are validated using a dual-polarization cloud lidar system for thin clouds (optical depth of approximately 4 or less).

remote sensing↗

First Results From an Uncooled LWIR Polarimeter for Cubesat Deployment

A compact long-wave infrared (LWIR) channeled spectro-polarimeter (IRCSP) has been developed for integration into the NASA Earth Science Technology Office (ESTO) funded submm-wave and LWIR polarimeters project to measure the microphysical properties of cloud ice. Once deployed, the IRCSP will produce the first linear Stokes measurements ( S0 , S1 , S2 ) of upper-tropospheric cirrus clouds from 8.5 to 12.5 μm. For the first time, a compact, light-weight, and uncooled LWIR polarimeter with off-the-shelf thermal optical components is demonstrated. We report narrowband calibration measurements which quantify metrics of polarimetric system performance. The response of the system to linearly polarized light is shown to agree with both a Mueller matrix model and modulation function for narrowband calibration measurements with an R2 > 0.98 from 8 to 11 μm. The polarimetric efficiency is >0.8 from 8 to 11 μm for narrowband measurements indicating satisfactory performance of the polarization optics. Beyond 11 μm, the agreement is significantly reduced as thermal noise compounds with reduced detector response. Ultimately, the observed system performance is limited by the spectral response of the detector past 11 μm in addition to the thermal noise inherent for the measurements at room temperature.

LWIR↗

Comprehensive Radiation Testing of Uncooled, Free Space Coupled, InGaAs Quad Photoreceivers

We have comprehensively tested uncooled, free space coupled, InGaAs Quad Photoreceivers having 0.5mm, 1mm, and 2mm diameter integrated with a low noise transimpedance amplifier (TIA)using 30MeV Protons, 100MeV Protons, 662keV Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron at room temperature of ~20°C.These devices find multiple applications in space for differential wave front sensing as part of a Gravitational Wave Observatory, as well as instrumentation and control for next generation space telescopes. The bandwidth of all receivers was 20MHz which was TIA limited. All 0.5mm and 1mm devices were found to be fully functional at normal operating conditions and at room temperature for Protons, Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron. Only one quadrant of a 2mm In GaAs Quad had hard failure due to 1GeV/n Helium Ions; otherwise it too survived all other radiation tests. Detailed test results follow in the manuscript including recommendations for future space flights. These radiation test results, combined with the earlier successful mechanical shock and vibration testing mean these devices have passed preliminary testing for space qualification.

Abhay M Joshi↗

Uncooled GeSn MWIR Photodetectors Using Fully Relaxed Thin Triple‐Step Buffer

GeSn photodetectors monolithically grown on Ge virtual substrates demonstrate mid-wave infrared (MWIR) detection at room temperature. The lattice mismatch between GeSn and Ge causes dislocations and compressive strain, creating leakage pathways and unwanted indirect band transitions. Designed thin Ge 0.91 Sn 0.09 triple-step buffer layers of ≈175 nm total thickness reduce dislocations and enable full relaxation, showing 100% lattice relaxation and smooth surface roughness of 0.83 nm with shorter auto-correlation length in surface morphology compared to single-step buffers. Ge 1-x Sn x photodetectors (x = 0.09, 0.12, and 0.15) on triple-step buffers with n-i-p configurations achieve lattice strain relaxations of 99%, 88%, and 80%, respectively. Ge 0.91 Sn 0.09 and Ge 0.88 Sn 0.12 show gradual variation in auto-correlation amplitude, while Ge 0.85 Sn 0.15 shows an increase due to lattice mismatch. Shockley–Read–Hall recombination current dominates at low reverse bias due to mismatch-induced dislocations, while band-to-band tunneling current dominates at higher reverse bias due to narrowing bandgap under strong electric fields. Here, the photodetectors show extended spectral response with increasing Sn composition of i-GeSn active layer sandwiched by barriers. Ge 0.88 Sn 0.12 and Ge 0.85 Sn 0.15 exhibit extended wavelength cut-offs of 3.12 and 3.27 µm at room temperature, demonstrating significant potential for silicon-based MWIR applications.

GeSn↗

A millimeter-wave pumped X-band uncooled parametric amplifier.

GaAs Schottky barrier varactors with a cutoff frequency of 800 GHz are used in a balanced diode-type parametric amplifier operating with a signal frequency at 7.5 GHz. The room-temperature parameters of the amplifier are a gain of 15 dB, a bandwidth of 500 MHz, and an excess noise temperature of 63 K (a noise figure of 0.86 dB).

Dickens, L. E.↗

Design and cold-air test of single-stage uncooled turbine with high work output

A solid version of a 50.8 cm single stage core turbine designed for high temperature was tested in cold air over a range of speed and pressure ratio. Design equivalent specific work was 76.84 J/g at an engine turbine tip speed of 579.1 m/sec. At design speed and pressure ratio, the total efficiency of the turbine was 88.6 percent, which is 0.6 point lower than the design value of 89.2 percent. The corresponding mass flow was 4.0 percent greater than design.

Moffitt, T. P.↗

Uncooled IR Detector

Detector combines liquid crystal film with light-sensitive solid-state array. Liquid-crystal film acts as IR detector when maintained just below temperature of transition from opacity to transparancey. When IR radiation is absorbed by film, resultant heating changes visiblelight transmission, modulating uniform visible light beam as it passes through film.

Shlichta, P. J.↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Comparison of Theoretically and Experimentally Determined Effects of Oxide Coatings Supplied by Fuel Additives on Uncooled Turbine-blade Temperature During Transient Turbojet-engine Operation

An analysis was made to permit the calculation of the effectiveness of oxide coatings in retarding the transient heat flow into turbine blades when the combustion gas temperature of a turbojet engine is suddenly changed. The analysis is checked with experimental data obtained from a turbojet engine whose blades were coated with two different coating materials (silicon dioxide and boric oxide) by adding silicone oil and tributyl borate to the engine fuel. The very thin coatings (approximately 0.001 in.) that formed on the blades produced a negligible effect on the turbine-blade transient temperature response. With the analysis discussed here, it was possible to predict the turbine rotor-blade temperature response with a maximum error of 40 F.

PROTECTIVE COATINGS↗

Progress in the utilization of an oxide-dispersion-strengthened alloy for small engine turbine blades

The conventional means of improving gas turbine engine performance typically involves increasing the turbine inlet temperature; however, at these higher operational temperatures the high pressure turbine blades require air-cooling to maintain durability. Air-cooling imposes design, material, and economic constraints not only on the turbine blades but also on engine performance. The use of uncooled turbine blades at increased operating temperatures can offer significantly improved performance in small gas turbine engines. A program to demonstrate uncooled MA6000 high pressure turbine blades in a GTEC TFE731 turbofan engine is being conducted. The project goals include demonstration of the advantages of using uncooled MA6000 turbine blades as compared with cast directionally solidified MAR-M 247 blades.

Beatty, T. G.↗

Development of radiometer windows for atmospheric entry vehicles

A test program was established to determine the feasibility of developing a radiometer window for stagnation region shock layer atmospheric entry experiments from geosynchronous orbit and with measurements extending into the VUV region to about 170 nm. This test program examined both isolated (uncooled) and cooled window mounting options. Preliminary tests determined the gross suitability of sapphire and fused silica as window materials. Measurements show that the expected maximum temperature (1500 C) is itself not a problem, but that temperature gradients can easily break a window and that the transmission of sapphire and of fused silica at 174 nm drops dramatically at temperatures beyond 800 C and 500 C, respectively. A series of developmental tests showed that the surface of an uncooled fused silica window begins to melt at the entry conditions tested while an uncooled sapphire window generally does not, and that a cooled sapphire window design that keeps the window below 800 C appears possible. The final proof-of-design tests narrowed the selection of possible candidate window sizes and mounting configurations. These tests demonstrate that the best insulated and cooled window designs use small diameter sapphire windows and that thermal modeling codes can be used to assist the design process.

Terrazas-Salinas, Imelda↗

Evaluation of Microbolometer-Based Thermography for Gossamer Space Structures

In August 2003, NASA's In-Space Propulsion Program contracted with our team to develop a prototype on-board Optical Diagnostics System (ODS) for solar sail flight tests. The ODS is intended to monitor sail deployment as well as structural and thermal behavior, and to validate computational models for use in designing future solar sail missions. This paper focuses on the thermography aspects of the ODS. A thermal model was developed to predict local sail temperature variations as a function of sail tilt to the sun, billow depth, and spectral optical properties of front and back sail surfaces. Temperature variations as small as 0.5 C can induce significant thermal strains that compare in magnitude to mechanical strains. These thermally induced strains may result in changes in shape and dynamics. The model also gave insight into the range and sensitivity required for in-flight thermal measurements and supported the development of an ABAQUS-coupled thermo-structural model. The paper also discusses three kinds of tests conducted to 1) determine the optical properties of candidate materials; 2) evaluate uncooled microbolometer-type infrared imagers; and 3) operate a prototype imager with the ODS baseline configuration. (Uncooled bolometers are less sensitive than cooled ones, but may be necessary because of restrictive ODS mass and power limits.) The team measured the spectral properties of several coated polymer samples at various angles of incidence. Two commercially available uncooled microbolometer imagers were compared, and it was found that reliable temperature measurements are feasible for both coated and uncoated sides of typical sail membrane materials.

Miles, Jonathan J.↗

The Effect of Inverse Compton Losses on Particle Acceleration in Three-dimensional Relativistic Reconnection

Relativistic magnetic reconnection is a key mechanism for dissipating magnetic energy and accelerating particles in astrophysics. In the absence of radiative cooling, recent particle-in-cell (PIC) simulations have shown that high-energy particles gain most of their energy in the upstream region, during a short-lived “free phase” where they meander between the two sides of the layer; when they get captured/trapped by the downstream flux ropes, they undergo a “trapped phase,” where no significant energization occurs. Here, we perform a suite of 3D PIC simulations of relativistic reconnection, including inverse Compton (IC) losses in the weakly cooled regime in which the radiation-reaction-limited Lorentz factor γrad exceeds the magnetization σ. We show that electron cooling losses do not appreciably alter the reconnection rate, the structure of the layer, and the physics of particle acceleration in the free phase, so the spectrum of free electrons is dN free /dγ ∝ γ −1 , as in the uncooled case. The spectrum of trapped electrons above the cooling break γcool (in the range γ cool < γ < γ rad ) is dN/dγ ∝ γ −3 , steeper than the scaling dN/dγ ∝ γ −2 of uncooled simulations. This confirms that no significant particle energization occurs during the trapped phase. Our results validate the model by Zhang et al. for particle acceleration in 3D relativistic reconnection, and imply that radiative emission models of reconnection-powered astrophysical sources should employ a two-zone structure that differentiates between free, rapidly accelerating particles and trapped, passively cooling particles.

79 ASTRONOMY AND ASTROPHYSICS↗