Search NASA⌕ Search

SEARCH · Search NASA

Results for “unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Test Report of Special Form Qualification Testing for the ORNL U ZipCan

This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSI N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

Advanced Hydrogen Fueling Station Supply: Tube Trailers

Air Products and Chemicals, Inc. (Air Products) is reporting on the results of a DOE-funded program to develop and validate Advanced Hydrogen Fueling Station hydrogen tube trailers to support hydrogen and fuel cell market applications. The project involved the engineering design and development of a new composite over-wrapped pressure vessel to increase the pressure capability of tube trailers to deliver hydrogen to greater than 8500 psi (586 bar). The new composite over-wrapped pressure vessel tube trailer was expected to provide improved delivery technology and reduce the cost of transporting hydrogen from central hydrogen production sources. The project aimed to meet or exceed DOE’s 2020 delivery targets for tube trailer hydrogen distribution. A gated approach was taken for the project, with early project Go/No-Go decision points. Specific goals for this four-stage product development project included: Preliminary Study, Modeling, and Analysis: Complete a preliminary design analysis and cost viability of a >8500 psi (586 bar) hydrogen storage vessel with an appropriate frame and chassis configuration for a complete trailer to US DOT requirements; Develop New Tube Size for >8500 psi (586 bar) Vessel: Fabricate tubes for test units, perform testing, and submit test results for a DOT Special Permit; Design, fabricate, and test a delivery trailer unit; Deploy the delivery trailer to hydrogen stations and collect data. Work conducted under DE-EE0006524 established costs for US DOT Type III vessels at 8500 psi (586 bar), 12500 psi (862 bar), and 14000 psi (965 bar) with manufactured water volumes up to 375 liters. Trailer module designs were established for the maximum US DOT design limits and for Air Products’ design limit of a 40-foot trailer length that addresses California hydrogen fueling station ingress and egress operating constraints. Conceptual trailer designs were not capable of achieving the DOE 2020 capacity and cost targets, but they did exceed the DOE pressure target of 500 bar. Based on new trailer cost and simulated operating performance, the 8500 psi (586 bar) new trailer design is not feasible in comparison to Air Products’ DOT-approved 7500 psi (520 bar) trailer design in operation today. Also, the project was expected to incur significantly higher product development costs associated with new US DOT vessel development and approval. Alternative trailer design concepts were explored that included 700 bar compression-less mobile fueling that could be promising for early-market hydrogen infrastructure fueling station placement and development and niche military applications. Due to the economic and budget challenges identified in the feasibility phase of the program, Air Products, in agreement with the Department of Energy, decided to terminate this development program.

08 HYDROGEN↗

Reactive jet and cyclonic attrition analysis of ilmenite in chemical looping combustion systems

In chemical looping combustion (CLC), the chosen oxygen carrier’s (OC) reactivity maintenance and attrition propensity play key roles in determining its lifetime in such systems. Jet and cyclonic attrition are two main mechanisms of attrition in CLC systems, which typically use fluidized beds and cyclones. In contrast to standardized tests, that assess attrition characteristics under ambient and non-reacting conditions, a realistic evaluation must include the behavior under relevant high temperatures and cyclic oxidation-reduction. In this study, separate jet and cyclonic attrition test units were constructed to investigate the effects of temperature, fuel gas concentration and velocity on the performance of ilmenite, a natural ore-based OC in CLC. Testing showed that thermal and chemical effects were crucial to accurately determine the performance of ilmenite. For experiments conducted between 820°C and 970°C, the intermediate temperature of 895°C provided the best balance between high reactivity and material durability. Additionally, fuel gas concentration affected particle morphology evolution. Iron migration to the surface of the ilmenite particle was enhanced at higher fuel gas concentrations and resulted in reduced attrition rate, presumably due to sintering of the more highly reduced enriched iron phase on the particle surface. The laboratory jet and cyclonic attrition evaluation test units tested in this study can be used to investigate multiple parameters relevant for OC performance, including the degree of reduction, oxygen carrying capacity, attrition resistance, agglomeration, and optimum material operability conditions, as well as to extrapolate test data to determine OC replacement costs in a commercial CLC system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Report for the Regulatory Testing of the Welded Isotek-SFC-W-3 Special Form Capsule

Two prototypes the welded ISOTEK-SFC-W-3 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the two welded ISOTEK-SFC-W-3 capsules. The test units were designated as TU-1 and TU-2. TU-1 was subjected to leak testing, percussion testing, and impact testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test on TU-1 was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). TU-2 was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in American National Standards Institute (ANSI) N14.5-2014. The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test Report for the Qualification Testing of the ORNL-SFC-W-1 Special Form Capsule

Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

42 ENGINEERING↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Report of Special Form Qualification Testing for the ORNL U ZiPCAN, Rev. 1

This report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by International Standards Organization (ISO) 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4).

42 ENGINEERING↗

Idiomatic Correctness-Checking via Julienne in Fortran 2023

This paper presents a unified approach to unit testing and runtime assertion checking using Fortran 2023. The paper describes the support for our approach in the Julienne framework. Julienne leverages recent Fortran standards to implement object-oriented design patterns, support testing parallel programs, and implement functional programming patterns in order to craft idioms inspired by natural-language expressions. The presented idioms employ novel operators to write expressions that evaluate to a test-diagnosis object encapsulating two components: (1) the test outcome or assertion outcome and (2) an automatically generated diagnostic string. Two other novel aspects of the approach include (1) the ability to enforce assertions inside pure procedures and (2) the ability to output rich diagnostic information inside pure procedures during error termination when assertions fail. The latter capability mitigates against a reason that Fortran programmers commonly cite for not writing pure procedures: difficulty obtaining useful program output inside pure procedures when debugging code. This paper demonstrates how the adoption of the proposed idioms leads naturally to a unifying theme across two otherwise disparate technologies: unit testing and runtime assertion checking. Finally, this paper describes the usage of the Julienne testing framework for writing unit tests and assertions in the Matcha high-performance computing application and the Fiats deep learning library.

Rouson, Damian↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Parallel Computing for Module-Based Computational Experiment

Large-scale scientific code plays an important role in scientific researches. In order to facilitate module and element evaluation in scientific applications, we introduce a unit testing framework and describe the demand for module-based experiment customization. We then develop a parallel version of the unit testing framework to handle long-term simulations with a large amount of data. Specifically, we apply message passing based parallelization and I/O behavior optimization to improve the performance of the unit testing framework and use profiling result to guide the parallel process implementation. Finally, we present a case study on litter decomposition experiment using a standalone module from a large-scale Earth System Model. This case study is also a good demonstration on the scalability, portability, and high-efficiency of the framework.

Yao, Zhuo↗

UnitTesterSG

UnitTesterSG is a unit testing framework that is designed for nested and/or scientific/engineering data structures. It is designed primarily for testing the outputs if a single function or simulation run by storing the expected results file such that comparisons to the stored output can be made with unit tests after the function or software has been edited. This module is designed to be able to unit test arrays, strings, as well as nested and deeply nested objects (including arrays with tuples inside, arrays with strings inside, etc.). The module is compatable with nested objects, and thus has a dependency on the nestedObjectsFunctions module within. The module takes *calculated* results and then compares them to *expected* results. If no expected results are available (or they do not match the calculated results) the module then offers to store the calculated results as expected results for next time.

Savara, Aditya [Oak Ridge National Lab. (ORNL), Oa↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 572: Test Cell C Ancillary Building and Structures - Nevada National Security Site, Nevada with ROTC 1

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 572, Test Cell C Ancillary Building and Structures, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 572 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada National Security Site: CAS 25-33-01, Building 3220, Equipment Building; CAS 25-33-02, Building 3230, Motor Drive Building; CAS 25-33-03, Building 3231, Pump House; CAS 25-33-04, Building 3232, Cryogenic Evaluation Lab; CAS 25-99-22, Ancillary Facilities. This plan provides the methodology for field activities needed to gather the necessary information for closing CAU 572. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 572 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. The purpose of the corrective action investigation (CAI) will be to document and verify the adequacy of existing information; to affirm the decision for either clean closure, closure in place, or no further action; and to provide sufficient data to implement the corrective action. The actual corrective action selected will be based on characterization activities implemented under this SAFER Plan. If it is determined that complete clean closure cannot be accomplished during the CAI, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place. This will be presented in a closure report that will be prepared and submitted to NDEP for review and approval.

54 ENVIRONMENTAL SCIENCES↗

Thermal analysis of Test Divertor Unit Scraper Element for Wendelstein 7-X

The Wendelstein-7X stellarator will go through three operational phases, with successively more energy as more complex divertors are installed. The first operational phase operated without a divertor, instead using five limiters (one in each of the five field periods), the second phase uses ten uncooled test divertor units (TDU), and the third will include an actively cooled divertor. Simulations of plasma operation have shown that the evolution of a toroidal current can lead to significant heat fluxes sweeping across sensitive regions in the divertor, possibly exceeding their qualified limit. A “Scraper Element” (SE) has been proposed to protect these sensitive divertor regions. To examine the effectiveness of this high heat-flux SE, a TDU Scraper Element (TDU-SE) is scheduled to operate with the TDU. A thermal analysis has been performed to correlate to measurements to be obtained during operation to evaluate the location and intensity of the convective plasma flux. The analysis will give an understanding of what is occurring at the plasma edge. As a result, it will also allow for a quick evaluation of the safety margin during initial, low power pulses so that the experiment can nimbly move to higher power operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molten salt to supercritical CO2 diffusion-bonded heat exchanger testing to support component certification for advanced nuclear power systems

Commercial utilization of the diffusion-bonded heat exchanger (DBHE) for high-temperature applications has prompted an ASME Boiler and Pressure Vessel Code Case development effort to employ these components in Section III (nuclear plant) applications. As part of this effort, a series of DBHE have been fabricated. These heat exchangers will be among the first printed-circuit geometries to be tested for functionality in a molten salt environment. These 15-25kW test specimens will be evaluated under steady-state conditions to compare pressure drop and terminal temperatures measurements with those predicted by existing flow and heat transfer correlations. The test units will then be subjected to thermal transients similar to those expected in Generation IV reactor systems by varying the hot and cold fluid mass flow rates and by changing inlet temperatures. Data collected from these tests will narrow the technical gaps related to two-fluid PCHE and identify special design requirements of compact heat exchangers containing primary reactor coolant. Descriptions of one of two test units and the testing plan are discussed here.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗