Hygroscopic Growth of UO 2 F 2 Particles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 particle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Anhydrous UO 2 F 2 particles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter of 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. These results demonstrate the hygroscopic properties of UO 2 F 2 particles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 particles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 particles in the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Field Alpha Spectrometer Development FY2022 Mid-Year Report

In response to needs identified by the International Atomic Energy Agency (IAEA), Idaho National Laboratory (INL) has developed an In-Field Alpha Spectrometer (IFAS) to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF 6 ) at processing facilities, to perform field assessments to verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, developed at Pacific Northwest National Laboratory (PNNL), which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO 2 F 2 ·2H 2 O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the course of this project INL, PNNL, Oak Ridge National Laboratory worked to optimize the SUDA sample design for alpha spectrometry, to optimize processes for manufacturing, loading, and shipping SUDA samples, and to allow the measurement of loaded SUDA samples. In fiscal year (FY) 2022 INL has bene investigating the reproducibility and measurement precision of IFAS measurements and the associated determination of uranium enrichment.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Online monitoring the hydrolysis of uranium hexafluoride for intermediates by cryogenic layering and FTIR

Uranium hexafluoride (UF 6 ) is a commonly utilized material feedstock in uranium enrichment processes due to its high vapor pressure and ease of sublimation. When exposed to air, UF 6 undergoes spontaneous hydrolysis to form uranyl fluoride (UO 2 F 2 ) particulates which are utilized for the detection of undeclared nuclear activities by nuclear safeguards organizations. In this study, the kinetics of the hydrolysis reaction and how they relate to particle morphology of the product are still debated in the literature. Here, we report the direct, in situ observation of UF 6 reaction intermediates by cooling the reaction to cryogenic temperatures to significantly reduce the rate of hydrolysis. The reaction is then observable by Fourier transform infrared (FTIR) spectroscopy. The conversion of UF 6 to UOF 4 is observed as well as several other bands associated with possible long lived intermediate complexes. Chemometrics are used to further elucidate the reaction pathway from UF 6 to UO 2 F 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimization Of In-field Alpha Spectrometry For Uranium Enrichment Determination In Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO2F2&middot;2H2O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

Chichester, David↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Optimization of In-Field Alpha Spectrometry for Uranium Enrichment Determination in Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (UO2F2). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An uranyl sorption study inside functionalised nanopores

Sorption mechanism of uranyl by poly(bis[2-(methacryloyloxy)ethyl] phosphate) (PB2MP) functionalised polyvinylidene fluoride (PVDF) track-etched membranes, PB2MP-g-PVDF, was investigated. It was found that uranyl sorption obeyed Langmuir isotherm model giving a maximum U(VI) membrane uptake of 6.73 μmol g -1 and an affinity constant of 9.85 10 6 L mol -1 . XPS and TRPL measurements were performed to identify sorbed uranyl oxidation state and its environment. Uranyl was found to be mainly in its hexavalent state, i.e. U(VI), showing that the trapping inside the PB2MPg-PVDF nanoporous membranes did not change the ion speciation. Two sorbed uranyl life-times ($τ_1$ = 8.8 μs and $τ_2$ = 102.8 μs) were measured by TRPL which pointed out different complexations taking place inside the nanopores. Uranyl sorption by PB2MP-g-PVDF membranes was also found to be pH dependent demonstrating the highest performance at circumneutral pH. In addition, TRPL was demonstrated to be not only a remarkable technique for U(VI) characterization, but also an alternative to voltammetry detection for trace on-site uranyl monitoring using PB2MP-g-PVDF nanoporous membranes

36 MATERIALS SCIENCE↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗