Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable data rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

The Galileo Spacecraft: A Communications Legacy for Future Space Flight

The Galileo mission to Jupiter has implemented a wide range of telecommunication improvements in response to the loss of it's high gain antenna. Among the communications enhancements that have been made are the use of advanced compression techniques, packetized telemetry, new error correcting codes and algorithms, more efficient modulation, variable transmission data rates, routine ground antenna arraying (even between continents,) extremely sensitive ground receivers, and non-real-time automated data reconstruction. This telecommunications legacy of Galileo will aid in our abillity to conduct a meaningful exploration of the solar system, and beyond, at a reasonable cost.

Galileo↗

Digital flight control systems

The design of stable feedback control laws for sampled-data systems with variable rate sampling was investigated. These types of sampled-data systems arise naturally in digital flight control systems which use digital actuators where it is desirable to decrease the number of control computer output commands in order to save wear and tear of the associated equipment. The design of aircraft control systems which are optimally tolerant of sensor and actuator failures was also studied. Detection of the failed sensor or actuator must be resolved and if the estimate of the state is used in the control law, then it is also desirable to have an estimator which will give the optimal state estimate even under the failed conditions.

Caglayan, A. K.↗

Variable rate neural compression for sparse detector data

Particle colliders produce data at extraordinary rates, posing major challenges for transmission and storage. High-throughput compression algorithms are therefore essential. In the sPHENIX experiment taking data at the Relativistic Heavy Ion Collider, a time projection chamber records three-dimensional (3D) particle trajectories that are highly sparse, making conventional learning-free lossy compression ineffective. Convolutional neural networks have surpassed traditional methods in compression ratio and accuracy. However, they fail to exploit sparsity for efficiency. To address these gaps, we present BCAE-VS, a bicephalous convolutional autoencoder with variable compression ratio for sparse data, which adapts compression to input complexity through key-point identification and sparse convolution. BCAE-VS achieves higher accuracy and compression ratios than prior neural approaches while being orders of magnitude smaller. Moreover, its throughput increases with sparsity—a property not observed in other methods. Although it was developed for collider experiments, BCAE-VS readily extends to other sparse data domains, such as light detection and ranging (LiDAR) sensing and 3D microscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of head-down bed rest on complex heart rate variability: Response to LBNP testing

Head-down bed rest is used to model physiological changes during spaceflight. We postulated that bed rest would decrease the degree of complex physiological heart rate variability. We analyzed continuous heart rate data from digitized Holter recordings in eight healthy female volunteers (age 28-34 yr) who underwent a 13-day 6 deg head-down bed rest study with serial lower body negative pressure (LBNP) trials. Heart rate variability was measured on a 4-min data sets using conventional time and frequency domain measures as well as with a new measure of signal 'complexity' (approximate entropy). Data were obtained pre-bed rest (control), during bed rest (day 4 and day 9 or 11), and 2 days post-bed rest (recovery). Tolerance to LBNP was significantly reduced on both bed rest days vs. pre-bed rest. Heart rate variability was assessed at peak LBNP. Heart rate approximate entropy was significantly decreased at day 4 and day 9 or 11, returning toward normal during recovery. Heart rate standard deviation and the ratio of high- to low-power frequency did not change significantly. We conclude that short-term bed rest is associated with a decrease in the complex variability of heart rate during LBNP testing in healthy young adult women. Measurement of heart rate complexity, using a method derived from nonlinear dynamics ('chaos theory'), may provide a sensitive marker of this loss of physiological variability, complementing conventional time and frequency domain statistical measures.

Goldberger, Ary L.↗

Stability of multirate sampled-data systems

Current adaptive sampling schemes that can be used in sampled-data systems with variable rate sampling does not guarantee the stability of the resulting closed-loop system. A study was undertaken with the objective of finding a stable control law for multirate sampled-data systems. The problem is formulated such that the sampling interval is selected from a set of fixed number of sample intervals. A necessary and sufficient condition under which these types of systems can be stabilized is given. For a certain subclass of these types of systems, a sampling selection algorithm is given which results in a stable closed-loop system.

Stanford, D. P.↗

Key Differences in Operating a Rover on the Moon vs. Mars

The command and control model for spacecraft operations, as well as the distribution of tasks between ground assets and in space assets, whether with a crew or solely robotic, is fundamentally constrained by the round trip light time between the space asset and the control facility (presumably on Earth, though not required). For an asset on Mars, the round trip light time varies, from roughly fourteen minutes to up to forty minutes. For a Lunar asset the round-trip light time is measured in only a few seconds, but current communications systems may more than double the latency with system overhead. For a Lunar Asset the total command latency may range from six seconds to more than forty, depending on communications overhead and data rates. Further, these variables are not always predictable, thus complicating operations. There are several differentiating factors for Lunar vs. Mars operations, Round trip light time/Atmosphere/Lighting and ShadowsTerrain type and knowledge/Round trip light time has implications for the distribution of tasks between ground and in space assets. Even at Lunar Distances, the combination of round trip light time plus communications systems overhead does not enable joy stick driving of a rover. The best that can be done, if driving from Earth, is near real time command and control. By 2030, driving from in space may be possible. Productivity on Mars requires either long operational sequences of commands, as is done for current rovers such as Curiosity, significant autonomous capability or, as may be possible by 2030, command and control support from space. Another implication of the long round trip light time from Earth to Mars, is that flight software functions must be resident on the in space asset. On the Moon, there is considerably more flexibility, enabling processing functions, to be resident on Earth or in space. This provides the opportunity to take advantage of the considerable processing power available on the ground, but may be constrained by data rates. On the Moon, for practical operational purposes, there is no atmosphere. Hence there is no scattering of light in the shadows. This has implications for image interpretation and driving near the poles. The Moon has permanently shadowed regions (PSR), unique terrain with unknown surface properties. With no scattering of light in shadows, driving on the Moon, particularly at the poles, where we have strong evidence of water, may prove to be hazardous and complex, requiring non-optical sensors, such as LIDAR.

Trimble, Jay↗

Testing of hypotheses about altitude decompression sickness by statistical analyses

This communication extends a statistical analysis of forced-descent decompression sickness at altitude in exercising subjects (J Appl Physiol 1994; 76:2726-2734) with a data subset having an additional explanatory variable, rate of ascent. The original explanatory variables for risk-function analysis were environmental pressure of the altitude, duration of exposure, and duration of pure-O2 breathing before exposure; the best fit was consistent with the idea that instantaneous risk increases linearly as altitude exposure continues. Use of the new explanatory variable improved the fit of the smaller data subset, as indicated by log likelihood. Also, with ascent rate accounted for, replacement of the term for linear accrual of instantaneous risk by a term for rise and then decay made a highly significant improvement upon the original model (log likelihood increased by 37 log units). The authors conclude that a more representative data set and removal of the variability attributable to ascent rate allowed the rise-and-decay mechanism, which is expected from theory and observations, to become manifest.

NASA Center JSC↗

A charge-transfer resistance model and Arrhenius activation analysis for hydrogen ion transmission across single-layer graphene

Transmission rates for protons and deuterons across single-layer graphene embedded in Nafion | graphene | Nafion sandwich structures are measured as a function of temperature in electrochemical hydrogen pump cells. Rates of ion transmission through graphene are obtained in the form of area-normalized ion-transfer resistances, and are interpreted in terms of ion-exchange current densities and standard heterogeneous ion-transfer rate constants. An encounter pre-equilibrium model for the ion-transfer step is then used to provide rate constants for the fundamental microscopic step of ion (proton or deuteron) transmission across graphene. Application of this rate model to interpret variable-temperature data on proton and deuteron transmission rates provides values for the activation energy and pre-exponential factor for the fundamental ion transmission step across graphene. Activation energies obtained from the Arrhenius plots for proton and deuteron transmission are as follows; for proton, E act = 48 ± 2 kJ/mole (0.50 ± 0.02 eV) and for deuteron, E act = 53 ± 5 kJ/mole (0.55 ± 0.05 eV). The difference between these two values of approximately 5 kJ/mole is in good agreement with the expected difference in vibrational zero-point energies for O—H and O-D bonds, albeit with some uncertainty given the uncertainties in the activation energy values. Pre-exponential frequency factor values of 8.3 ± 0.4 × 10 13 s -1 and is 4.7 ± 0.5 × 10 13 s -1 were obtained for proton and deuteron transmission respectively across graphene. These pre-factor values are both quite large, on the order of the values predicted from the Eyring – Polanyi equation with a transmission coefficient near one. The ratio of 1.8 for the rate pre-factors (H/D) is in reasonable agreement with the value of 1.3 for the ratio of bond vibrational frequencies for O—H and O-D stretching, respectively. Taken together, these data support a model in which proton and deuteron transmission across graphene are largely adiabatic processes for which the differences in transmission rate at room temperature are due largely to differences in activation energies.

2D materials↗

Formation and Reactivity of a Persistent Radical in a Dinuclear Molybdenum Complex

The reactivity of the S-H bond in Cp*Mo(μ-S) 2 (μ-SMe)(μ-SH)MoCp* (S 4 MEH) has been explored by hydrogen atom abstraction to form the radical Cp*Mo(μ-S) 3 (μ-SMe)MoCp* (S 4 ME∙), as well as hydrogen addition to the radical to reform the S-H complex. The rate expression for abstraction of hydrogen atom by benzyl radical has been determined, giving log(k abs /M -1 s -1 ) = (2.41 ? 0.37)/(2.303RT) + (7.88 ? 0.25) with k abs = 1.3 x 106 M -1 s -1 at 25ºC. The radical termination product of the Mo2S4 core was found to be the benzyl cross-termination product, Cp*Mo(μ-S) 2 (μ-SMe)(μ-SBz)MoCp*. Structures are presented for this complex as well as the cationic Cp*Mo(μ-S2)(μ-S)(μ-SMe)MoCp*(OTf), a precursor of the radical and the alkylated derivatives. The radical undergoes reversible dimerization to form the tetranuclear complex (Cp*Mo(μ-S) 2 (μ-SMe)MoCp*) 2 (μ-S 2 ), as shown by the solid state structure. In solution, the radical and the dimer are in equilibrium, and the equilibrium constant for dimerization has been estimated from magnetic susceptibility and EPR data. The rate of dissociation of the dimer has been determined to be 640 s-1 at 25ºC, based on variable temperature 1H NMR data. The rate constant for dimerization of the radical has been estimated to be 6.5 x 10 7 M -1 s -1 , based on the dimer dissociation rate constant and the lower limit of the equilibrium constant for dimerization.

08 HYDROGEN↗

Relationships between pediatric asthma and socioeconomic/urban variables in Baltimore, Maryland

Spatial relationships between clinical data for pediatric asthmatics (hospital and emergency department utilization rates), and socioeconomic and urban characteristics in Baltimore City were analyzed with the aim of identifying factors that contribute to increased asthma rates. Socioeconomic variables and urban characteristics derived from satellite data explained 95% of the spatial variation in hospital rates. The proportion of families headed by a single female was the most important variable accounting for 89% of the spatial variation. Evidence suggests that the high rates of hospital admissions and emergency department (ED) visits may partially be due to the difficulty of single parents with limited resources managing their child's asthma condition properly. This knowledge can be used for education towards mitigating ED and hospital events in Baltimore City.

Emergency Service, Hospital/utilization↗

Improved Quality in Aerospace Testing Through the Modern Design of Experiments

This paper illustrates how, in the presence of systematic error, the quality of an experimental result can be influenced by the order in which the independent variables are set. It is suggested that in typical experimental circumstances in which systematic errors are significant, the common practice of organizing the set point order of independent variables to maximize data acquisition rate results in a test matrix that fails to produce the highest quality research result. With some care to match the volume of data required to satisfy inference error risk tolerances, it is possible to accept a lower rate of data acquisition and still produce results of higher technical quality (lower experimental error) with less cost and in less time than conventional test procedures, simply by optimizing the sequence in which independent variable levels are set.

DeLoach, R.↗

Method and apparatus for spatially variable rate application of agricultural chemicals based on remotely sensed vegetation data

Remotely sensed spectral image data are used to develop a Vegetation Index file which represents spatial variations of actual crop vigor throughout a field that is under cultivation. The latter information is processed to place it in a format that can be used by farm personnel to correlate and calibrate it with actually observed crop conditions existing at control points within the field. Based on the results, farm personnel formulate a prescription request, which is forwarded via email or FTP to a central processing site, where the prescription is prepared. The latter is returned via email or FTP to on-side farm personnel, who can load it into a controller on a spray rig that directly applies inputs to the field at a spatially variable rate.

Hood, Kenneth Brown↗

Method and system for spatially variable rate application of agricultural chemicals based on remotely sensed vegetation data

Remotely sensed spectral image data are used to develop a Vegetation Index file which represents spatial variations of actual crop vigor throughout a field that is under cultivation. The latter information is processed to place it in a format that can be used by farm personnel to correlate and calibrate it with actually observed crop conditions existing at control points within the field. Based on the results, farm personnel formulate a prescription request, which is forwarded via email or FTP to a central processing site, where the prescription is prepared. The latter is returned via email or FTP to on-side farm personnel, who can load it into a controller on a spray rig that directly applies inputs to the field at a spatially variable rate.

Hood, Kenneth Brown↗

Conditional replenishment using motion prediction

Conditional replenishment is an interframe video compression method that uses correlation in time to reduce video transmission rates. This method works by detecting and sending only the changing portions of the image and by having the receiver use the video data from the previous frame for the non-changing portion. The amount of compression that can be achieved through this technique depends to a large extent on the rate of change within the image, and can vary from 10 to 1 to less than 2 to 1. An additional 3 to 1 reduction in rate is obtained by the intraframe coding of data blocks using a 2-dimensional variable rate Hadamard transform coder. A further additional 2 to 1 rate reduction is achieved by using motion prediction. Motion prediction works by measuring the relative displacements of a subpicture from one frame to the next. The subpicture can then be transmitted by sending only the value of the 2-dimensional displacement. Computer simulations have demonstrated that data rates of 2 to 4 Mega-bits/second can be achieved while still retaining good fidelity in the image.

Hein, D. N.↗

Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗