Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An analytical study of the effect of coolant flow variables on the kinetic energy output of a cooled turbine blade row.

Demonstration that the change in output of a cooled turbine blade row relative to the specific output of the uncooled blade row can be positive, negative, or zero, depending on the velocity, injection location, injection angle, and temperature of the coolant. Comparisons between the analytical results and experimental results for four different cases of coolant discharge, all at a coolant temperature ratio of unity, show good agreement for three cases, and rather poor agreement for the other.

Prust, H. W., Jr.↗

Experimental aerodynamic heating to simulated space shuttle tiles in laminar and turbulent boundary layers with variable flow angles at a nominal Mach number of 7

The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally by using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold wall heating rate data for laminar and turbulent flow were obtained in the Langley 8 foot high Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300R, a free stream unit Reynolds number from 3.4 x 10 sup 5 to 2.2 10 sup 6 per foot, and a free stream dynamic pressure from 2.1 to 9.0 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads. For the conditions of the present study, the results show that localized and total heating are sensitive to changes in flow angle only for the test conditions of turbulent boundary layer flow with high kinetic energy and that a flow angle from 30 deg to 50 deg will minimize the local heating.

Avery, D. E.↗

Self-Calibrating, Variable-Flow Pumping System

Pumping system provides accurate, controlled flows of two chemical liquids mixed in spray head and react to form rigid or flexible polyurethane or polyisocyanurate foam. Compatible with currently used polyurethane-based coating materials and gas-bubble-forming agents (called "blowing agents" in industry) and expected to be compatible with materials that used in near future. Handles environmentally acceptable substitutes for chlorofluorocarbon foaming agents.

Walls, Joe T.↗

Emergence of Unstable Focused Flow Induced by Variable‐Density Flows in Vertical Fractures

Abstract Fluids with different densities often coexist in subsurface fractures and lead to variable‐density flows that control subsurface processes such as seawater intrusion, contaminant transport, and geologic carbon sequestration. In nature, fractures have dip angles relative to gravity, and density effects are maximized in vertical fractures. However, most studies on flow and transport through fractures are often limited to horizontal fractures. Here, we study the mixing and transport of variable‐density fluids in vertical fractures by combining three‐dimensional (3D) pore‐scale numerical simulations and visual laboratory experiments. Two miscible fluids with different densities are injected through two inlets at the bottom of a fracture and exit from an outlet at the top of the fracture. Laboratory experiments show the emergence of an unstable focused flow path, which we term a “runlet.” We successfully reproduce the unstable runlet using 3D numerical simulations and elucidate the underlying mechanisms triggering the runlet. Dimensionless number analysis shows that the runlet instability arises due to the Rayleigh‐Taylor instability (RTI), and flow topology analysis is applied to identify 3D vortices that are caused by the RTI. Even under laminar flow regimes, fluid inertia is shown to control the runlet instability by affecting the size and movement of vortices. Finally, we confirm the emergence of a runlet in rough‐walled fractures. Since a runlet dramatically affects fluid distribution, residence time, and mixing, the findings in this study have direct implications for the management of groundwater resources and subsurface applications.

Environmental Sciences & Ecology↗

Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A scalable geometric multigrid solver for nonsymmetric elliptic systems with application to variable-density flows

A geometric multigrid algorithm is introduced for solving nonsymmetric linear systems resulting from the discretization of the variable density Navier–Stokes equations on nonuniform structured rectilinear grids and high-Reynolds number flows. The restriction operation is defined such that the resulting system on the coarser grids is symmetric, thereby allowing for the use of efficient smoother algorithms. To achieve an optimal rate of convergence, the sequence of interpolation and restriction operations are determined through a dynamic procedure. A parallel partitioning strategy is introduced to minimize communication while maintaining the load balance between all processors. To test the proposed algorithm, we consider two cases: 1) homogeneous isotropic turbulence discretized on uniform grids and 2) turbulent duct flow discretized on stretched grids. Testing the algorithm on systems with up to a billion unknowns shows that the cost varies linearly with the number of unknowns. This O (N) behavior confirms the robustness of the proposed multigrid method regarding ill-conditioning of large systems characteristic of multiscale high-Reynolds number turbulent flows. The robustness of our method to density variations is established by considering cases where density varies sharply in space by a factor of up to 104, showing its applicability to two-phase flow problems. Strong and weak scalability studies are carried out, employing up to 30,000 processors, to examine the parallel performance of our implementation. Excellent scalability of our solver is shown for a granularity as low as 104 to 105 unknowns per processor. At its tested peak throughput, it solves approximately 4 billion unknowns per second employing over 16,000 processors with a parallel efficiency higher than 50%.

Computer Science↗

Siphon flows in isolated magnetic flux tubes. V - Radiative flows with variable ionization

Steady siphon flows in arched isolated magnetic flux tubes in the solar atmosphere are calculated here including radiative transfer between the flux tube and its surrounding and variable ionization of the flowing gas. It is shown that the behavior of a siphon flow is strongly determined by the degree of radiative coupling between the flux tube and its surroundings in the superadiabatic layer just below the solar surface. Critical siphon flows with adiabatic tube shocks in the downstream leg are calculated, illustrating the radiative relaxation of the temperature jump downstream of the shock. For flows in arched flux tubes reaching up to the temperature minimum, where the opacity is low, the gas inside the flux tube is much cooler than the surrounding atmosphere at the top of the arch. It is suggested that gas cooled by siphon flows contribute to the cool component of the solar atmosphere at the height of the temperature minimum implied by observations of the infrared CO bands at 4.6 and 2.3 microns.

Montesinos, Benjamin↗

High-order fully implicit solver for all-speed fluid dynamics: AUSM ride from nearly incompressible variable-density flows to shock dynamics

We introduce a novel Newton–Krylov (NK)-based fully implicit algorithm for solving fluid flows in a wide range of flow conditions—from variable density nearly incompressible to supersonic shock dynamics. The key enabling feature of our all-speed solver is the ability to efficiently solve conservation laws by choosing a set of independent variables that produce a well-conditioned Jacobian matrix for the linear iterations of the global nonlinear iterative solver. In particular, instead of choosing to discretize the conservative variables (density, momentum, total energy), which is traditionally used in Eulerian high-speed compressible fluid dynamics, we demonstrate superior performance by discretizing the primitive variables—pressure–velocity–temperature in the very low-Mach flow limits or density–velocity–temperature/entropy in the shock dynamics range. Moreover, our method allows us to avoid direct inversion of the mass matrix in discrete time derivatives, which is usually an additional source for stiffness, especially pronounced when going to very high-order schemes with non-orthogonal basis functions. Here, we show robust solutions obtained for discontinuous finite element discretization up to seventh-order accuracy. Another important aspect of the solution algorithm is the Advection Upstream Splitting Method (AUSM), adopted to compute numerical fluxes within our reconstructed discontinuous Galerkin (rDG) spatial discretization scheme. The use of the low-Mach modification of the hyperbolic flux operator is found to be necessary for enabling robust simulations of very stiff liquids and metals for Mach numbers below M=10 -5 , which is well known to be very computationally challenging for compressible solvers. We demonstrate that our fully implicit rDG-NK solver with the AUSM + -up flux treatment produces efficient and high-resolution numerical solutions at all speeds, ranging from vanishing Mach numbers to transonic and supersonic, without substantial modifications of the solution procedures. (At high speed, we add limiting and use a simpler preconditioning of the Krylov solver.) Numerical examples include nearly incompressible constant-property flow past a backward-facing step with heat transfer, low-Mach variable-property channel flow of water at supercritical state, phase change and melt pool dynamics for laser spot welding and selective laser melting in additive manufacturing, and Mach 3 flow in a wind tunnel with a step.

97 MATHEMATICS AND COMPUTING↗

Simulating seawater intrusion in a complex coastal karst aquifer using an improved variable-density flow and solute transport–conduit flow process model

VDFST-CFP (variable-density flow and solute transport–conduit flow process) is a density-dependent discrete-continuum numerical model for simulating seawater intrusion in a dual-permeability coastal karst aquifer. A previous study (Xu and Hu 2017) simulates variable-density flow only in a single conduit, and studies the parameter sensitivities only in the horizontal case (2D domain as horizontal section) by the VDFST-CFP model. This paper focuses on the density-dependent vertical case (2D domain as vertical section) with two major improvements: 1) when implementing double-conduit networks in the domain, simulated intruded plumes in the porous medium are extended in the double-conduit scenario, compared to the single-conduit system; 2) by quantifying micro-textures on the conduit wall by the Goudar-Sonnad equation and considering macro-structures as local head loss. Sensitivity analysis shows that medium hydraulic conductivity, conduit diameter and effective porosity are important parameters for simulating seawater intrusion in the discrete-continuum system. On the other hand, rougher micro-structures and additional macro-structure components on the conduit wall would reduce the distance of seawater intrusion to the conduit system, but, rarely affect salinity distribution in the matrix. Compared to the equivalent mean roughness height, the new method (with more detailed description of structure) simulates seawater intrusion slightly landward in the conduit system. Here, the macro-structure measured by local head loss is more reasonable but needs further study on conduit flow. Xu and Hu (2017) Development of a discrete-continuum VDFST-CFP numerical model for simulating seawater intrusion to a coastal karst aquifer with a conduit system.

58 GEOSCIENCES↗

Modeling variability in porescale multiphase flow experiments

Microfluidic devices and porescale numerical models are commonly used to study multiphase flow in biological, geological, and engineered porous materials. In this work, we perform a set of drainage and imbibition experiments in six identical microfluidic cells to study the reproducibility of multiphase flow experiments. We observe significant variations in the experimental results, which are smaller during the drainage stage and larger during the imbibition stage. We demonstrate that these variations are due to sub-porescale geometry differences in microcells (because of manufacturing defects) and variations in the boundary condition (i.e.,fluctuations in the injection rate inherent to syringe pumps). Computational simulations are conducted using commercial software STAR-CCM+, both with constant and randomly varying injection rate. Stochastic simulations are able to capture variability in the experiments associated with the varying pump injection rate.

54 ENVIRONMENTAL SCIENCES↗

Nongray radiative interactions in entry region flows with variable properties

The entrance region flow between parallel plates is investigated numerically and the variation of fluid properties with temperature is considered. The effect of variable properties for both laminar and turbulent flows is presented. Laminar flows are found to be affected to a larger extent than turbulent flows, as far as the effect of variable properties are concerned.

Krishnamurthy, R.↗

A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus

This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗