Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Accelerated Life Testing Dataset for Lithium-Ion Batteries With Constant and Variable Loading Conditions

The dataset repository is organized into three main folders, each containing one group of life cycled battery packs. Within each folder individual battery packs own their dedicated csv file for continuous data logging, which are named with their respective battery pack number. The folders are named: - regular_alt_batteries: Containing one csv file for each battery pack cycled at the same load level or load range throughout lifetime - recommissioned_batteries: Containing one csv file for each battery pack cycled at different load levels at varying life stages - second_life_batteries: Containing one csv file for each second life battery pack cycled at constant current througout the second life

Li-ion Battery↗

TALSPEAK EXTRACTION SYSTEM UNDER VARIABLE LOADING CONDITIONS - PART 2: SPECIATION STUDIES

The reported investigation was performed to gain structural information on the organic phase complex species in the Trivalent Actinide-Lanthanide Separation by Phosphorus reagent Extraction from Aqueous Komplexes (TALSPEAK) process under various loading conditions. In conjunction with the distribution studies of the TALSPEAK system constituents, presented in Part 1 of this investigation, loaded bis(2-ethylhexyl) phosphoric acid (HDEHP)/isooctane was evaluated using various spectroscopic techniques including NMR, FTIR and visible absorbance spectroscopy. Liquid-liquid distribution and vapor pressure osmometry (VPO) aggregation results correlate with observed changes in the spectroscopic signatures as a function of organic phase loading and water partitioning. Explicit FTIR spectral interpretation of the HDEHP spectra is complex due to overlapping phosphorus absorbance bands, and in this work a combination of the spectroscopic techniques was utilized to elucidate the phosphorus-lanthanide complex structure and changes in speciation due to aggregation. The results from this research will benefit an overall improved prediction of the TALSPEAK process performance under flow conditions.

99 GENERAL AND MISCELLANEOUS↗

Electronically Variable Resistive Load

Electronically variable linear resistive load circuit synthesized by use of analog components to control conductance of power metal oxide/semiconductor field-effect transistors, MOSFET's. Circuit has modular configuration, in which single controller drives parallel load units. A 3-kW load module that exhibits submicrosecond response time with respect to control signal demonstrated.

Niedra, Janis M.↗

PV output smoothing with energy storage

This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

14 SOLAR ENERGY↗

In-situ I-V measurement of a module in a PV array

In one respect, disclosed is an in-situ current-voltage (I-V) measurement device for photovoltaic modules in a photovoltaic array, comprising a variable load, wherein the variable load is configured to be connected in parallel with a module, wherein the module is connected in series with at least one other module in a string, such that the module supplies current simultaneously to the string and to the variable load, and wherein the variable load is controlled by a controller, and wherein the controller is configured to shift an I-V operating point of the module, based at least upon varying the variable load.

Gostein, Michael↗

Residential Variable-Capacity Heat Pumps Sized to Heating Loads

Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method of operating a thermoelectric generator

A method for operating a thermoelectric generator supplying a variable-load component includes commanding the variable-load component to operate at a first output and determining a first load current and a first load voltage to the variable-load component while operating at the commanded first output. The method also includes commanding the variable-load component to operate at a second output and determining a second load current and a second load voltage to the variable-load component while operating at the commanded second output. The method includes calculating a maximum power output of the thermoelectric generator from the determined first load current and voltage and the determined second load current and voltage, and commanding the variable-load component to operate at a third output. The commanded third output is configured to draw the calculated maximum power output from the thermoelectric generator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

17 WIND ENERGY↗

Prediction of fatigue-crack growth in a high-strength aluminum alloy under variable-amplitude loading

The present paper is concerned with the application of an analytical crack-closure model to study crack growth under various load histories. The model was based on a crack-tip plasticity concept like the Dugdale model, but modified to leave plastically deformed material in the wake of the advancing crack tip. The effect of material thickness on plasticity was accounted for by using a constraint factor on tensile yielding at the crack tip. The model was used to correlate crack-growth rates under constant-amplitude loading, and to predict crack growth under variable-amplitude loading on a high-strength aluminum alloy (7475-T7351) sheet material. The experimental data were obtained from Zhang et al. Predicted crack-growth lives agreed well with experimental data. For ten crack-growth tests subjected to various variable-amplitude load histories, the ratio of predicted-to-experimental lives ranged from 0.54 to 1.19. The mean value of the ratio of predicted-to-experimental lives was 0.95 and the standard error was 0.2 using a constraint factor of 1.9 in the model. Crack-opening stresses calculated from the model were significantly different from those determined by Zhang et al. using a striation-based experimental method.

Newman, J. C., Jr.↗

Prediction of fatigue-crack growth in a high-strength aluminum alloy under variable-amplitude loading

The present paper is concerned with the application of an analytical crack-closure model to study crack growth under various load histories. The model was based on a concept like the Dugdale model, but modified to leave plastically deformed material in the wake of the advancing crack tip. The thickness effect was accounted for by using a 'constraint' factor on tensile yielding at the crack tip. The model was used to correlate crack-growth rates under constant-amplitude loading, and to predict crack growth under variable-amplitude loading on a high-strength aluminum alloy (7475-T7351) sheet material. The experimental data was obtained from Zhang et al. Predicted crack-growth lives agreed well with experimental data. For ten crack-growth tests subjected to various variable-amplitude load histories, the ratio of predicted-to-experimental lives ranged from 0.54 to 1.19. The mean value of predicted-to-experimental lives was 0.95 with a standard error of 0.2 for a constraint factor of 1.9.

Newman, J. C., Jr.↗

Observations of fatigue crack growth rate and closure behavior in 7475-T731 aluminum under variable amplitude loading

Simultaneous measures of fatigue crack propagation rate and crack closure were taken from 7475-T731 aluminum alloy center cracked tensile specimens under variable amplitude loading conditions. Results indicate the presence of load interaction in a variety of repeated variable amplitude loading blocks. Load interaction results in retardation of the propagation rate for most loading blocks examined in the study. Closure did not explain observed delay behavior associated with high stress ratio and single peak overloads. Primary influences on the crack opening stress intensity level include the maximum stress intensity of the repeated loading block, the minimum stress intensity of the block, and the number of fatigue cycles between overloads of the block.

Turner, Charles C.↗

Transient characteristics of a grooved water heat pipe with variable heat load

The transient characteristics of a grooved water heat pipe were studied by using variable heat load. First, the effects of the property variations of the working fluid with temperature were investigated by operating the water heat pipe at several different temperatures. The experimental results show that, even for the same heat input profile and heat pipe configuration, the heat pipe transports more heat at higher temperature within the tested temperature range. Adequate liquid return to the evaporator due to decreasing viscosity of the working fluid permits continuous vaporization of water without dry-out. Second, rewetting of the evaporator was studied after the evaporator had experienced dry-out. To rewet the evaporator, the elevation of the condenser end was the most effective way. Without elevating the condenser end, rewetting is not straight-forward even with power turned off unless the heat pipe is kept at isothermal condition for sufficiently long time.

Jang, Jong Hoon↗

Variability in large-scale wind power generation: Variability in large-scale wind power generation

The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net load events. The comparison shows regions with low variability (Sweden, Spain and Germany), medium variability (Portugal, Ireland, Finland and Denmark) and regions with higher variability (Quebec, Bonneville Power Administration and Electric Reliability Council of Texas in North America; Gansu, Jilin and Liaoning in China; and Norway and offshore wind power in Denmark). For regions with low variability, the maximum 1 h wind ramps are below 10% of nominal capacity, and for regions with high variability, they may be close to 30%. Wind power variability is mainly explained by the extent of geographical spread, but also higher capacity factor causes higher variability. It was also shown how wind power ramps are autocorrelated and dependent on the operating output level. When wind power was concentrated in smaller area, there were outliers with high changes in wind output, which were not present in large areas with well-dispersed wind power.

17 WIND ENERGY↗

Analog synthesized fast-variable linear load

A several kilowatt power level, fast-variable linear resistor was synthesized by using analog components to control the conductance of power MOSFETs. Risetimes observed have been as short as 500 ns with respect to the control signal and 1 to 2 microseconds with respect to the power source voltage. A variant configuration of this load that dissipates a constant power set by a control signal is indicated. Replacement of the MOSFETs by static induction transistors (SITs) to increase power handling, speed and radiation hardness is discussed.

Niedra, Janis M.↗

Multiaxial creep–fatigue Life Prediction Under Variable Amplitude Loading at High Temperature

Based on the time–temperature parameter method, a modified von Mises stress is proposed to calculate the multiaxial creep damage at high temperature. By employing the strain-based multiaxial fatigue damage models, the modified von Mises stress is used to predict the creep–fatigue life under variable amplitude multiaxial loading at high temperature. The experimental data of GH4169 superalloy and 304 stainless steel conducted under both constant and variable amplitude loadings at high temperature are used to verify the proposed method, and a good agreement is obtained with the experimental data.

42 ENGINEERING↗