Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utilizing a Suited Manikin Test Apparatus and Spacesuit Ventilation Loop to Evaluate Carbon Dioxide Washout

NASA is pursuing technology development of an Advanced Extravehicular Mobility Unit (AEMU) which is an integrated assembly made up of primarily a pressure garment system and a Portable Life Support System (PLSS). The PLSS is further composed of an oxygen subsystem, a ventilation subsystem, and a thermal subsystem. One of the key functions of the ventilation system is to remove and control the carbon dioxide delivered to the crewmember. Carbon dioxide washout is the mechanism by which CO2 levels are controlled within the spacesuit helmet to limit the concentration of CO2 inhaled by the crew member. CO2 washout performance is a critical parameter needed to ensure proper and robust designs that are insensitive to human variabilities in a spacesuit. A Suited Manikin Test Apparatus (SMTA) is being developed to augment testing of the PLSS ventilation loop in order to provide a lower cost and more controlled alternative to human testing. The CO2 removal function is performed by the regenerative Rapid Cycle Amine (RCA) within the PLSS ventilation loop and its performance is evaluated within the integrated SMTA and Ventilation Loop test system. This paper will provide a detailed description of the schematics, test configurations, and hardware components of this integrated system. Results and analysis of testing performed with this integrated system will be presented within this paper.

Chullen, Cinda↗

Utilizing a Suited Manikin Test Apparatus and Space Suit Ventilation Loop to Evaluate Carbon Dioxide Washout

NASA is pursuing technology development of an Advanced Extravehicular Mobility Unit (AEMU) which is an integrated assembly made up of primarily a pressure garment system and a portable life support subsystem (PLSS). The PLSS is further composed of an oxygen subsystem, a ventilation subsystem, and a thermal subsystem. One of the key functions of the ventilation system is to remove and control the carbon dioxide (CO2) delivered to the crewmember. Carbon dioxide washout is the mechanism by which CO2 levels are controlled within the space suit helmet to limit the concentration of CO2 inhaled by the crew member. CO2 washout performance is a critical parameter needed to ensure proper and robust designs that are insensitive to human variabilities in a space suit. A suited manikin test apparatus (SMTA) was developed to augment testing of the PLSS ventilation loop in order to provide a lower cost and more controlled alternative to human testing. The CO2 removal function is performed by the regenerative Rapid Cycle Amine (RCA) within the PLSS ventilation loop and its performance is evaluated within the integrated SMTA and Ventilation Loop test system. This paper will provide a detailed description of the schematics, test configurations, and hardware components of this integrated system. Results and analysis of testing performed with this integrated system will be presented within this paper.

Chullen, Cinda↗

Swing Bed Scrubber Design and Test Integration Results for Carbon Dioxide Removal in the Ventilation Test Loop 2.0

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS provides the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The PLSS ventilation subsystem is responsible for providing adequate carbon dioxide (CO2) and water vapor removal. To experimentally validate the performance of CO2 removal and advanced CO2 sensing systems, NASA Johnson Space Center developed the Ventilation Test Loop 2.0 (VTL2) and tested the Oceaneering Swing Bed Scrubber (SBS) that was fabricated and delivered under the Constellation Space Suit System Contract in 2015. The SBS was designed to continuously remove CO2 and water vapor from a space suit ventilation loop with a pair of thermally integrated amine beds that alternately adsorb and desorb water vapor and CO2. The SBS hardware was recently resurrected and reassembled to support a full battery of performance testing in the VTL2. This paper describes the design and development of the SBS and the VTL2 along with the performance test results of the SBS.

Ventilation Test Loop↗

Space station ventilation study

A ventilation system design and selection method which is applicable to any manned vehicle were developed. The method was used to generate design options for the NASA 33-foot diameter space station, all of which meet the ventilation system design requirements. System characteristics such as weight, volume, and power were normalized to dollar costs for each option. Total system costs for the various options ranged from a worst case $8 million to a group of four which were all approximately $2 million. A system design was then chosen from the $2 million group and is presented in detail. A ventilation system layout was designed for the MSFC space station mockup which provided comfortable, efficient ventilation of the mockup. A conditioned air distribution system design for the 14-foot diameter modular space station, using the same techniques, is also presented. The tradeoff study resulted in the selection of a system which costs $1.9 million, as compared to the alternate configuration which would have cost $2.6 million.

Colombo, G. V.↗

Measurement of continuous distributions of ventilation-perfusion ratios - Theory

The resolution of the technique considered is sufficient to describe smooth distributions containing blood flow to unventilated regions (shunt), ventilation to unperfused regions (dead space), and up to three additional modes over the range of finite ventilation-perfusion ratios. In particular, areas whose ventilation-perfusion ratios are low can be separated from unventilated regions and those whose ventilation-perfusion ratios are high can similarly be distinguished from unperfused areas.

Wagner, P. D.↗

A preliminary investigation of the drag and ventilation characteristics of livestock haulers

A wind tunnel evaluation of the drag and ventilation characteristics of a conventional (unmodified) and five modified subscale model livestock haulers at 0 deg yaw angle has been made. The unmodified livestock hauler has a relatively high drag coefficient, and a low velocity recirculation region exists in the forward portion of the hauler. The use of a streamlined forebody and enclosed gap reduced the drag coefficient of one model by 42% and improved the rate at which contaminants can be flushed from the cargo compartment by a factor of 2.5. From the limited data obtained, any increase in the fraction of open area of the trailer sides was found to improve the trailer ventilation. The use of a ram air inlet can improve the ventilation within the hauler and remove the low velocity recirculation region at the expense of a modest increase in the truck's drag coefficient. A mathematical model for vehicles with ram air or NACA submerged inlets was developed and appears to adequately predict the ventilation characteristics of livestock haulers.

Hoffman, J. A.↗

Influence of ventilated shrouds on the convective heat transfer to a circular cylinder

Convective heat transfer to shrouded cylinders in transverse flow has been studied over the Reynolds number range 2000-20,000. The influence of shroud ventilation, relative shroud diameters, and orientation of the ventilation holes was studied. In some cases, average inner-cylinder Nusselt numbers were found to exceed the comparable bare-cylinder values by as much as 50 percent. Cylinder heat convection was influenced more by the degree of ventilation and shroud diameter than by hole orientation. An equivalent inner bare cylinder diameter, based on degree of shroud ventilation and shroud diameter, was developed which can be useful in shroud design studies.

Daryabeigi, Kamran↗

Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems

A document discusses the design and prototype of an advanced spacesuit concept that integrates the capability to function seamlessly with multiple ventilation system approaches. Traditionally, spacesuits are designed to operate both dependently and independently of a host vehicle environment control and life support system (ECLSS). Spacesuits that operate independent of vehicle-provided ECLSS services must do so with equipment selfcontained within or on the spacesuit. Suits that are dependent on vehicle-provided consumables must remain physically connected to and integrated with the vehicle to operate properly. This innovation is the design and prototype of a hybrid spacesuit approach that configures the spacesuit to seamlessly interface and integrate with either type of vehicular systems, while still maintaining the ability to function completely independent of the vehicle. An existing Advanced Crew Escape Suit (ACES) was utilized as the platform from which to develop the innovation. The ACES was retrofitted with selected components and one-off items to achieve the objective. The ventilation system concept was developed and prototyped/retrofitted to an existing ACES. Components were selected to provide suit connectors, hoses/umbilicals, internal breathing system ducting/ conduits, etc. The concept utilizes a lowpressure- drop, high-flow ventilation system that serves as a conduit from the vehicle supply into the suit, up through a neck seal, into the breathing helmet cavity, back down through the neck seal, out of the suit, and returned to the vehicle. The concept also utilizes a modified demand-based breathing system configured to function seamlessly with the low-pressure-drop closed-loop ventilation system.

Daniel, Brian A.↗

Full Stall Simulations of a Redesigned Ventilation Fan for the ISS

The concept of a stall is studied rigorously in the aerospace industry. From a design standpoint, instabilities such as stall are undesirable– operation in the stall regime has a tremendous impact on aerodynamic performance as well as structural integrity. In extreme cases, operating in stall conditions can cause failure. Further, stall can cause a loss of lift on aircraft wings or a loss of thrust in aircraft engines. In any case, stall continues to be a topic of interest in the aerospace industry. The present work aims to analyze the stall characteristics of a ventilation fan that was recently designed for the International Space Station (ISS). Although the ventilation fan has a rotor-stator design, this paper considers a rotor-only configuration. The FUN3D Computational Fluid Dynamic (CFD) solver developed by NASA Langley Research Center was used to simulate the operational characteristics of the ventilation fan. FUN3D solves the Unsteady Reynolds-Averaged Naiver-Stokes (URANS) equations using implicit time marching and a dynamic overset grid. The FUN3D solver was originally written for exterior flow fields; however, this work represents an extension of the FUN3D solver to turbomachinery or interior flow fields. The FUN3D results for the rotor-only ventilation fan accurately captured the operational characteristics inherent to compressors– the results shared similar performance trends when compared to the experimental results for the rotor-stator case. A peak adiabatic efficiency of 96% occurred at a MFR of 105.2 CFM, the minimum aerodynamically stable point. A computationally stable stall occurred at a mass flow rate of 43.8 CFM where the adiabatic efficiency dropped to 69%.

CFD↗

Quiet Spacecraft Cabin Ventilation Fan Development: Motivation and Context

It is important to control acoustical noise aboard crewed space vehicles and space habitats to provide a satisfactory environment for voice communications, alarm audibility, and restful sleep, and to minimize the risk for hearing loss and annoyance. As with most noise control efforts, it is best to control the noise at the source, and for spaceflight vehicles these are typically the fans associated with the Environmental Control and Life Support system. These include cabin ventilation fans and intermodule ventilation fans, among others. Throughout the history of crewed spaceflight, there have been issues with noise from ventilation fans, going back to Apollo. And, with the spaceflight vehicles and habitats currently being developed, there are again concerns with noise from ventilation fans. To address this problem, NASA is working to leverage the technology developed in its Aeronautics Research Mission Directorate, specifically at the Glenn Research Center, to design highly efficient and quiet fans for reducing community noise levels from civilian aircraft. This paper will discuss the need for transfer of this technology to spaceflight use, and will discuss the potential benefits, which are significant and will be crucial for the successful development and operations of future spaceflight vehicles, space suits, and habitats.

Christopher S. Allen↗

Ventilation-perfusion matching in long-term microgravity

We studied the ventilation-perfusion matching pattern in normal gravity (1 G) and short- and long-duration microgravity (microG) using the cardiogenic oscillations in the sulfur hexaflouride (SF(6)) and CO(2) concentration signals during the phase III portion of vital capacity single-breath washout experiments. The signal power of the cardiogenic concentration variations was assessed by spectral analysis, and the phase angle between the oscillations of the two simultaneously expired gases was obtained through cross-correlation. For CO(2), a significant reduction of cardiogenic power was observed in microG, with respect to 1 G, but the reduction was smaller and more variable in the case of SF(6). A shift from an in-phase condition in 1 G to an out-of-phase condition was found for both short- and long-duration microG. We conclude that, although the distribution of ventilation and perfusion becomes more homogeneous in microG, significant inhomogeneities persist and that areas of high perfusion become associated with areas of relatively lower ventilation. In addition, these modifications seem to remain constant during long-term exposure to microG.

Mir Project↗

Regional ventilation-perfusion distribution is more uniform in the prone position

The arterial blood PO(2) is increased in the prone position in animals and humans because of an improvement in ventilation (VA) and perfusion (Q) matching. However, the mechanism of improved VA/Q is unknown. This experiment measured regional VA/Q heterogeneity and the correlation between VA and Q in supine and prone positions in pigs. Eight ketamine-diazepam-anesthetized, mechanically ventilated pigs were studied in supine and prone positions in random order. Regional VA and Q were measured using fluorescent-labeled aerosols and radioactive-labeled microspheres, respectively. The lungs were dried at total lung capacity and cubed into 603-967 small ( approximately 1.7-cm(3)) pieces. In the prone position the homogeneity of the ventilation distribution increased (P = 0.030) and the correlation between VA and Q increased (correlation coefficient = 0.72 +/- 0.08 and 0.82 +/- 0.06 in supine and prone positions, respectively, P = 0.03). The homogeneity of the VA/Q distribution increased in the prone position (P = 0.028). We conclude that the improvement in VA/Q matching in the prone position is secondary to increased homogeneity of the VA distribution and increased correlation of regional VA and Q.

NASA Program Biomedical Research and Countermeasur↗

Ventilation-perfusion matching during exercise

In normal subjects, exercise widens the alveolar-arterial PO2 difference (P[A-a]O2) despite a more uniform topographic distribution of ventilation-perfusion (VA/Q) ratios. While part of the increase in P(A-a)O2 (especially during heavy exercise) is due to diffusion limitation, a considerable amount is caused by an increase in VA/Q mismatch as detected by the multiple inert gas elimination technique. Why this occurs is unknown, but circumstantial evidence suggests it may be related to interstitial pulmonary edema rather than to factors dependent on ventilation, airway gas mixing, airway muscle tone, or pulmonary vascular tone. In patients with lung disease, the gas exchange consequences of exercise are variable. Thus, arterial PO2 may increase, remain the same, or fall. In general, patients with advanced chronic obstructive pulmonary disease (COPD) or interstitial fibrosis who exercise show a fall in PO2. This is usually not due to worsening VA/Q relationships but mostly to the well-known fall in mixed venous PO2, which itself results from a relatively smaller increase in cardiac output than VO2. However, in interstitial fibrosis (but not COPD), there is good evidence that a part of the fall in PO2 on exercise is caused by alveolar-capillary diffusion limitation of O2 transport; in COPD (but not interstitial fibrosis), a frequent additional contributing factor to the hypoxemia of exercise is an inadequate ventilatory response, such that minute ventilation does not rise as much as does CO2 production or O2 uptake, causing arterial PCO2 to increase and PO2 to fall.

Non-NASA Center↗

The effect of gas diffusion on the flow coefficient for a ventilated cavity

The results of an experimental investigation into the effect of gas diffusion on the volume flow-rate of gas needed to sustain a ventilated cavity are presented. Gas diffusion was found to have a significant effect on the ventilated flow rate required to sustain a cavity of a given size. An analysis for the gas diffusion effect was conducted based on a mathematical model of diffusion proposed by Brennen. The results compare favorably with experimental data. Also, an empirical scaling relationship is proposed for ventilated cavity flows.

Billet, M. L.↗

Protective garment ventilation system

A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

Lang, R.↗

Distribution of pulmonary ventilation and perfusion during short periods of weightlessness

Airborne experiments were conducted on four trained normal male subjects (28-40 yr) to study pulmonary function during short periods (22-27 sec) of zero gravity obtained by flying a jet aircraft through appropriate parabolic trajectories. The cabin was always pressurized to a sea-level altitude. The discussion is limited to pulmonary ventilation and perfusion. The results clearly demonstrate that gravity is the major factor causing nonuniformity in the topographical distribution of pulmonary ventilation. More importantly, the results suggest that virtually all the topographical nonuniformity of ventilation, blood flow, and lung volume observed under 1-G conditions are eliminated during short periods of zero gravity.

Michels, D. B.↗

Measurement of convective heat transfer to solid cylinders inside ventilated shrouds

The influence of ventilated cylindrical shrouds on the convective heat transfer to circular cylinders has been studied experimentally. Geometries studied were similar to those used in commercially available platinum resistance thermometers. Experiments showed that thermal response (convection) was enhanced when the shroud ventilation factor was approximately 20 percent (80 percent solid), and that maximum enhancement occurred when the ventilation holes were located symmetrically on either side of the stagnation lines.

Daryabeigi, K.↗

Ventilating Air-Conditioner

Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

Dinh, Khanh↗