Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

This research involved construction of a conditioned test hut in a cold climate (Climate Zone 5A) with multiple side-by-side instrumented roof rafter bays. This work examined seven experimental unvented roofs and one code-compliant control hybrid ccSPF-cellulose roof over three winters and following summers. Examined variables included insulation material (fiberglass and cellulose), the presence or absence of a ridge diffusion vent (vapor-open material at the roof ridge to promote drying), the effect of various interior vapor control membranes (fixed and variable permeance), the effect of interior relative humidity, and the effect of interstitial airflow (from the interior into the cavity). This experiment was run over three winters, changing variables of interior conditions, roof configurations/materials, and the addition of intentional air leakage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

Vented and sealed cookoff of powdered and pressed ε-CL-20

In this work, we have completed a series of vented and sealed cookoff experiments of the ε-polymorph of CL-20 in our Sandia Instrumented Thermal Ignition (SITI) apparatus using both powder and pressed pellets at nominal densities of 313 ± 8 kg/m 3 and 1030 ± 4 kg/m 3 , respectively. The boundary temperature of our aluminum confinement cylinder was ramped in 10 minutes from room temperature to a prescribed set-point temperature ranging between 448 nd 468 K and held at the set-point temperature until ignition. A universal cookoff model (UCM) has been calibrated using the ε-CL-20 SITI data to predict pressurization and thermal ignition of ε-CL-20. The ignition model was validated by using one-dimensional time-to-explosion (ODTX) ignition data from a different laboratory. We found that a thirtyfold increase in the reaction rates due to liquefaction at 520 K could explain the high temperature ODTX cookoff data. The model gives a plausible explanation of why melting is important in fast cookoff events involving CL-20. Our model also gives support to 520 K as the liquefaction point of CL-20, which has different values in the literature.

36 MATERIALS SCIENCE↗

Lithium-Ion Battery Vent Gas Tools

The spreadsheets and Python scripts are used to determine vent gas hazard metrics (i.e. flammability limits, flame speed, etc.). These scripts and spreadsheets use open source literature to determine these hazard metrics. SAND2020-12540 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Baird, Austin↗

Qualification of Mitutoyo RA-2200 Roundness Tester Measuring Instrument for Clad Vent Set Cup Roundness and Flatness Inspections

Roundness (or circularity) and flatness measurements are made as part of the dimensional inspection process to certify that iridium alloy Clad Vent Set (CVS) cups meet the dimensional requirements of Iridium Alloy Cup Drawing M2D920101A005, Rev. 4 (see Figure 1). A Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester is specified in the cup inspection Procedure GPHS-C-3624/25, Rev. 25 for roundness (dimension 16) and flatness (dimension 17). The Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester stopped functioning in 2019. A new Mitutoyo RA-2200 Roundness Tester was purchased to replace the MMQ 400. Evaluations were conducted to qualify the new RA-2200 for CVS cup dimensional inspection work. The criterion for qualification was to ensure that the new RA-2200 instrument would yield roundness and flatness inspection results equivalent to or better than the predecessor MMQ 400 instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smart Vent System (SYSM 562 Final Project_Guest and Fleurantin)

Current residential air conditioning (AC) and heating units do a decent job at providing overall cooling/heating to a household. However, they usually fall short on accurately controlling which rooms to be heated and cooled. Most homes also require you to manually open or close a vent which can be very inconvenient if in a hard-to-reach area. There is a need for a system capable of automatically measuring and maintaining the thermal environment of each room throughout a house to meet a user’s preferences.

42 ENGINEERING↗

LAW Primary Offgas Process (LOP) and LAW Secondary Offgas/Vessel Vent Process (LVP) System Design Description

This system design description (SDD) defines the technical, functional, and performance requirements of the Low-Activity Waste (LAW) Facility primary offgas process system (LOP) and the LAW Facility secondary offgas/vessel vent process system (LVP). This document details waste treatment requirements, environmental compliance requirements, and authorization basis requirements of the LOP and LVP systems as they are currently known and understood.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Barometric Pumping Through Fractured Rock: A Mechanism for Venting Deep Methane to Mars' Atmosphere

Abstract Both the source of methane on Mars and the mechanism for transmission from the subsurface to the atmosphere are not fully understood. Previous seepage simulations have invoked relatively shallow subsurface sources to explain observed methane signatures on Mars. We propose that barometric‐pressure pumping through fracture networks could be an effective mechanism for methane transport from the deep subsurface on Mars. Using atmospheric pressure data gathered by Curiosity as input, we simulate methane gas transport from depths of 200 m to the surface. Even with such a deep source, our model reproduces the observed seasonality of methane, and the simulated surface methane fluxes fall within the range of previous estimates derived from atmospheric observations. Because 200 m is the likely minimum hospitable depth for living methanogenic microbes, our fracture network model indirectly reinvigorates the possibility of a microbial source of methane on Mars.

58 GEOSCIENCES↗

Area G FTWC Venting Operations, Transportation, and Moving to the WETF Facility [Slides]

What is a FTWC? Flanged Tritium Waste Containers (FTWC) are designed to hold tritium contaminated waste. The tritium contaminated waste is in secondary containers such as plastic bags and paint cans. Tritium is a gas that is lighter than air. Hydrogen gas is lighter-than-air. Hydrogen gas forms explosive mixtures with air from 4% concentration to 75% concentration. Tritium gas has a Biological ½ life = 10 – 12 days. It is a beta particle emitter. Exposure can occur by inhalation or by skin adsorption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Behavior of Natural Seep Vents: Analysis of Field and Laboratory Observations and Modeling (Final Scientific/Technical Report)

In this project, we have analyzed data collected by the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) in a high pressure water tunnel (HPWT) and data from two research cruises to natural seeps in the Gulf of Mexico to adapt and validate a numerical model to predict the dynamics of natural seeps in the deep oceans. The HPWT data include video observations of the shrinkage rate of individual methane and natural gas bubbles under simulated deep-water conditions. Field data were collected during two cruises by the Gulf Integrated Spill Research (GISR) Consortium led by Texas A&M University and funded by the Gulf of Mexico Research Initiative (GoMRI). These data included in situ observations from a remotely operated vehicle (ROV) of gas bubbles at two natural seep sites in the Gulf and acoustic observations of the natural seep bubble flares in the ocean water column. The acoustic data were from multibeam echosounders, one mounted in a forward-looking orientation on the ROV and another mounted down-looking in the haul of the ship. All of these laboratory and field data were focused on the dynamics of natural gas bubbles at temperatures and pressures favorable for clathrate hydrate formation between the gas and water. Our analyses of this data focused on understanding the mechanisms responsible for gas bubble dissolution within the hydrate stability zone (HSZ) of the oceans. Ice-like hydrate shells may form on the bubble-water interface under these conditions, and it was unknown how this might affect the mass transfer of gas into the ocean. We were able to extract bubble shrinkage rates from the HPWT datasets. Using this data we determined that mass transfer coefficients with and without a hydrate shell match empirical values for bubbles in contaminated systems (so-called dirty bubbles contaminated by naturally occurring surfactants). We also showed that free gas, and not gas hydrate, is the dominant dissolving phase when the hydrate sub-cooling is below 11 degree Celsius (temperature difference between hydrate the hydrate formation temperature and ambient temperator) or the pressure is reducing as bubbles rise through the ocean water column. Using this mass transfer model, our numerical model of bubble dissolution matched the over 200 HPWT experiments with an average error of 10% for predicting the bubble size at the end of an experiment. From field data in the literature, we also observed that gas bubbles dissolve faster when they are initially released, following mass transfer coefficients for so-called clean-bubbles (those not yet contaminated by surfactants). Shortly after release within the HSZ, a hydrate shell forms on the bubble-water interface, and the mass transfer reduces to rates matching those of dirty bubbles. We correlated this transition time from clean to dirty bubble behavior with the initial bubble surface area and the hydrate sub-cooling. With this model for hydrate formation time and using the mass transfer coefficients deduced from the HPWT data, we validated our numerical model for predicting the rise heights of natural seep flares in the oceans. Flare heights are commonly observed in haul-mounted acoustic multibeam data. The numerical model predicts bubbles to rise high in the ocean water column owing to the slower mass transfer rates for dirty bubbles that accompany the majority of their rise time. We found that the numerical model predictions matched the observed flare heights within 5% to 10% accuracy when we compared the rise heights of the largest bubbles released from the seafloor with the bubbles acoustically visible in the multibeam data. Bubbles become acoustically transparent as they shrink to sizes of order 1 mm in diameter for the multibeam frequencies used in the field. The forward-looking multibeam on the ROV also provided data on the lateral spreading of bubbles in natural seep flares. Our analysis of this data showed that spreading follows a diffusion process, with the effective diffusivity correlating with the wobbling length scale of these ellipsoidal bubbles. When we apply this diffusivity in a random displacement model of bubble spreading, our numerical simulations match closely the lateral spread observed by the M3 in the ocean water column. Finally, we compared the seep model predictions for the acoustic properties of these natural seep plumes with that observed by the acoustic instruments in the field. The M3 and EM 302 observations were converted to relative values of target strength using a calibration we obtained in the laboratory for the M3 and using an algorithm from the manufacturer for the EM 302. Comparing the numerical seep model to these data, we obtain good agreement over the whole height of rise of these bubble flares. This further validates the numerical model. Overall, our validated seep model captures the key dynamics of gas bubbles released from natural seeps in the oceans and helps to predict the fate of methane in the water column.

03 NATURAL GAS↗

Flange Tritium Waste Containers Operational Concerns: How to Address the Issues Through the Venting Design

As a part of the U.S. Department of Energy (DOE), Los Alamos National Laboratory (LANL or Laboratory) must comply with regulations in the Clean Air Act (CAA) put forth in 40 Code of Federal Regulations (CFR) 61, Subpart H “National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities.” The standard states, “Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr [millirem per year] [1].” This regulation is referred to as the National Emission Standards for Hazardous Air Pollutants for Radionuclides (Radionuclide NESHAP or Rad-NESHAP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗