Search NASA⌕ Search

SEARCH · Search NASA

Results for “virtual impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Extended Impedance Control Using Real and Virtual Sensors for Redundant Manipulators

Control of a redundant manipulator based on an impedence control framework with multiple simultaneous control sources is described. Each control source provides a different behavior type. An application is decomposed into multiple simultaneous behaviors whose resultant behavior will provide the motion necessary to execute the task. The simultaneous control inputs are merged using impedance control to compute a resultant command to the manipulator. The task space of each behavior can have the dimensionality of the mechanism being controlled. Control of a seven degree of freedom manipulator is described here with an available task space for each behavior of dimensionality seven.

telerobotics control architecture simultaneous beh↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifunctional Films Deposited by Atomic Layer Deposition for Tailored Interfaces of Electrochemical Systems

A new strategy for electrochemical interfaces that utilizes multilayer films deposited by atomic layer deposition (ALD) is introduced. Manganese-rich and nickel-rich cathode oxides were coated with a novel bilayer film of metal fluorides. Subsequent exposure to prolonged, high-voltage electrochemical cycling vs graphite electrodes revealed that the bilayer film can greatly enhance the high-voltage stability of cathode oxides. In particular, in manganese-rich cells, capacity fade due to manganese dissolution was substantially reduced and impedance rise was virtually eliminated. Furthermore, in nickel-rich NMC-811 cells, impedance rise was reduced by ~80%, compared to the NMC-811 baseline, after ~300 h of high-voltage exposure during cycling. Here, the multilayer film strategy presents an exciting opportunity for tailoring designs and materials for electrochemical interfaces in advanced lithium-ion batteries and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impedance‐matching model‐in‐the‐loop simulation

Abstract Impedance matching is a novel approach to executing model‐in‐the‐loop (MIL) simulations. The concept, key features, and sample applications of this approach have been described in a series of publications. This paper advances theory and implementation for impedance‐matching MIL by: (1) developing a feedback linearization technique for implementing MIL for nonlinear virtual systems, (2) systematically characterizing MIL performance‐stability tradeoffs using three design‐oriented criteria—performance: defined as closeness of the controlled‐actuator impedance to the virtual‐boundary impedance;control effort: low controller response at high frequencies to reduce sensitivity to measurement noise and uncertainties in the actuator model; andstability: pursued using passivity of the controlled actuator system, and (3) assessing, through experimentation, the robustness of two ways to estimate feedback reaction force from the test article. These fundamental advancements to MIL are described using a one‐dimensional configuration consisting of a fluid‐filled cylindrical vessel as the physical test article and a uniaxial hydraulic shake table controlled to imitate different seismic isolation systems at the base of the vessel.

Engineering↗

Uncertainty Analysis of the Grazing Flow Impedance Tube

This paper outlines a methodology to identify the measurement uncertainty of NASA Langley s Grazing Flow Impedance Tube (GFIT) over its operating range, and to identify the parameters that most significantly contribute to the acoustic impedance prediction. Two acoustic liners are used for this study. The first is a single-layer, perforate-over-honeycomb liner that is nonlinear with respect to sound pressure level. The second consists of a wire-mesh facesheet and a honeycomb core, and is linear with respect to sound pressure level. These liners allow for evaluation of the effects of measurement uncertainty on impedances educed with linear and nonlinear liners. In general, the measurement uncertainty is observed to be larger for the nonlinear liners, with the largest uncertainty occurring near anti-resonance. A sensitivity analysis of the aerodynamic parameters (Mach number, static temperature, and static pressure) used in the impedance eduction process is also conducted using a Monte-Carlo approach. This sensitivity analysis demonstrates that the impedance eduction process is virtually insensitive to each of these parameters.

Brown, Martha C.↗

The ATS-6 power system: Hardware implementation and orbital performance

The Applications Technology Satellite-6 power system, a shunt-boost configuration, uses partial shunt regulation of the solar array and a boost regulator for control of battery power. Regulation is provided for three different operating modes: shunt, charge, and boost. This configuration achieves the highest efficiency of power transfer from the solar array to the loads. The excellent dynamic regulation and low output impedance of the power system virtually eliminated the problem of subsystem interactions on the power bus due to conducted interference from load current fluctuations. The performance of the power system continues to be excellent. The solar array degradation (18.5 percent) was less than the specified 20 percent in two years in spite of extreme cycling from -160 C to 60 C. A unique battery cycling regime of discharges varying from 5 percent to 60 percent daily is being encountered. During the second year, noneclipse discharges have occurred twice a day to depths of 35 percent and 45 percent. Battery performance was good with only a small decrease in end-of-discharge voltage. A recent test to evaluate capacity gave 12.4 AH (83% of the nominal capacity of 15 AH) after over 1400 battery discharge cycles. A small increase in the end-of-charge voltage has recently occurred necessitating a change in the charge regime to achieve full charge conditions.

Lavigna, T. A.↗

Stability Considerations for Virtual Capacitor Control in Constant Power DC Loads

In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Differential InP HEMT MMIC Amplifiers Embedded in Waveguides

Monolithic microwave integrated-circuit (MMIC) amplifiers of a type now being developed for operation at frequencies of hundreds of gigahertz contain InP high-electron-mobility transistors (HEMTs) in a differential configuration. The differential configuration makes it possible to obtain gains greater than those of amplifiers having the single-ended configuration. To reduce losses associated with packaging, the MMIC chips are designed integrally with, and embedded in, waveguide packages, with the additional benefit that the packages are compact enough to fit into phased transmitting and/or receiving antenna arrays. Differential configurations (which are inherently balanced) have been used to extend the upper limits of operating frequencies of complementary metal oxide/semiconductor (CMOS) amplifiers to the microwave range but, until now, have not been applied in millimeter- wave amplifier circuits. Baluns have traditionally been used to transform from single-ended to balanced configurations, but baluns tend to be lossy. Instead of baluns, finlines are used to effect this transformation in the present line of development. Finlines have been used extensively to drive millimeter- wave mixers in balanced configurations. In the present extension of the finline balancing concept, finline transitions are integrated onto the affected MMICs (see figure). The differential configuration creates a virtual ground within each pair of InP HEMT gate fingers, eliminating the need for inductive vias to ground. Elimination of these vias greatly reduces parasitic components of current and the associated losses within an amplifier, thereby enabling more nearly complete utilization of the full performance of each transistor. The differential configuration offers the additional benefit of multiplying (relative to the single-ended configuration) the input and output impedances of each transistor by a factor of four, so that it is possible to use large transistors that would otherwise have prohibitively low impedances. Yet another advantage afforded by the virtual ground of the differential configuration is elimination of the need for a ground plane and, hence, elimination of the need for back-side metallization of the MMIC chip. In turn, elimination of the back-side metallization simplifies fabrication, reduces parasitic capacitances, and enables mounting of the MMIC in the electric-field plane ("E-plane") of a waveguide. E-plane mounting is consistent with (and essential for the utility of) the finline configuration, in which transmission lines lie on a dielectric sheet in the middle of a broad side of the waveguide. E-plane mounting offers a combination of low loss and ease of assembly because no millimeter-wave wire bonds or transition substrates are required. Moreover, because there is no ground plane behind the MMIC, the impedance for the detrimental even (single-ended) mode is high, suppressing coupling to that mode. Still another advantage of E-plane mounting is that the fundamental waveguide mode is inherently differential, eliminating the need for a balun to excite the differential mode.

Kangaslahti, Pekka↗

Accelerating Parallel Applications in Cloud Platforms via Adaptive Time-Slice Control

Cloud platforms can provide flexible and cost-effective environments for parallel applications. However, the resource over-commitment issues, i.e., cloud providers often provide much more executable virtual CPUs than available physical CPUs, still impede the synchronization operations of parallel applications, causing severe performance degradation. Existing methods optimize parallel applications by promoting the priorities of involved VMs. They cannot fully explore the performance of parallel applications, because they ignore the time-slice requirements of different phases of parallel applications. Furthermore, non-parallel applications experience unsatisfied performance because of low scheduling priorities. Given empirical analysis on time-slices of virtual machines (VMs), we find that shortening time-slices can mitigate synchronization overhead which incurs during communication phases, while over-short time-slices cause frequent cache misses in computation phases. Accordingly, we propose an Adaptive Time-slice Control (ATC) mechanism. ATC first detects the phases of parallel applications based on lock latency or cache misses. Then, ATC shortens time-slices during communication phases and prolongs time-slices during computation phases for parallel applications, and sets a uniform time-slice for non-parallel applications. Finally, we evaluate ATC using seven well-known benchmarks with 25+ applications. Experiments show that ATC obtains 1.5-75x performance gain for running parallel applications than state-of-the-art solutions, with nearly unaffected impact on non-parallel applications.

97 MATHEMATICS AND COMPUTING↗

Master-slave system with force feedback based on dynamics of virtual model

A master-slave system can extend manipulating and sensing capabilities of a human operator to a remote environment. But the master-slave system has two serious problems: one is the mechanically large impedance of the system; the other is the mechanical complexity of the slave for complex remote tasks. These two problems reduce the efficiency of the system. If the slave has local intelligence, it can help the human operator by using its good points like fast calculation and large memory. The authors suggest that the slave is a dextrous hand with many degrees of freedom able to manipulate an object of known shape. It is further suggested that the dimensions of the remote work space be shared by the human operator and the slave. The effect of the large impedance of the system can be reduced in a virtual model, a physical model constructed in a computer with physical parameters as if it were in the real world. A method to determine the damping parameter dynamically for the virtual model is proposed. Experimental results show that this virtual model is better than the virtual model with fixed damping.

Nojima, Shuji↗

Unified Robot-Control Scheme

Report describes unified scheme for autonomous supervisory, shared, and teleoperation control of robotic manipulator equipped with multiple position, force, and velocity sensors. Scheme developed according to impedance-control approach in which manipulator acts as different specified impedance to each sensor source, real or virtual. Relatively simple control system has wide range of capabilities, and enables relatively simple integration of new sensors into system.

Backes, Paul G.↗

Interactive Metadata Integration with Brick

Many different digital representations of a building are produced over the course of its lifecycle. While these representations individually contain metadata required to support different stages of the building's lifecycle, they are largely not interoperable due to differences in structure, syntax and semantics. This impedes the development and deployment of data-driven applications providing fault detection and diagnosis, virtual metering or optimal control. [4] introduces a new platform for the continuous curation of a unified, Brick [1]-based metadata model that can be maintained throughout the building lifecycle. In this demonstration, we present a live proof-of-concept implementation of the platform with support for several metadata representations in the context of a simulated building lifecycle.

Fierro, Gabe↗