Search NASA⌕ Search

SEARCH · Search NASA

Results for “visible laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advanced propulsion concepts study: Comparative study of solar electric propulsion and laser electric propulsion

Solar electric propulsion (SEP) and laser electric propulsion (LEP) was compared. The LEP system configuration consists of an 80 kW visible laser source on earth, transmitting via an 8 m diameter adaptively controlled phased array through the atmosphere to a 4 m diameter synchronous relay mirror that tracks the LEP spacecraft. The only significant change in the SEP spacecraft for an LEP mission is the replacement of the two 3.7 m by 33.5 m solar cell arrays with a single 8 m diameter laser photovoltaic array. The solar cell array weight is decreased from 320 kg to 120 kg for an increase in payload of 200 kg and a decrease in specific mass of the power system from 20.5 kg/kW to 7.8 kg/kW.

Forward, R. L.↗

UV Laser Development for In Situ Planetary Lander Instruments

Mass and Raman spectrometers represent progressive analytical platforms for future in situ lander missions to explore the surface chemistry of planetary bodies across the Solar System. Europa, the Moon, and Mars are some of the primary targets for future NASA missions to search for extraterrestrial life and potentially habitable environments beyond Earth, further our understanding of the timing and formation of the Solar System and identify potentially viable economic resources such as water and/or valuable metal assets. The CORALS (Characterization of Ocean Residues And Life Signatures) and CRATER (Characterization of Regolith And Trace Economic Resources) instruments are UV laser-enabled OrbitrapTM mass spectrometers currently under development for prospective lander missions to Europa and the Moon, respectively. The Raman Mass Spectrometer (RAMS) is a dual wavelength (UV and visible) laser enabled hybrid instrument that incorporates laser desorption/ ionization mass spectrometry (LDMS) and micro-Raman microspectroscopy imaging (μRS) into a compact instrument package for multiple planetary missions to the inner and outer Solar System. The Pulse Laser Ablation Sampling and Mass Analysis (PLASMA) instrument combines a multi-wavelength laser (deep-UV to near-IR), plasma source, and collision cell with a heritage quadrupole mass spectrometer (QMS) to enable high precision trace element analyses for a future Lunar lander instrument. We report on the advancement of four compact, robust, and high technology readiness level (TRL) solid state lasers operating at wavelengths 213 nm, 266 nm, 515 nm, 532 nm and 1064 nm that serve as the sampling and ionization sources, for the CRATER, CORALS, RAMS and PLASMA investigations.

Molly Fahey↗

Filtered Rayleigh scattering measurements in supersonic/hypersonic facilities

Preliminary measurements are presented of flow field properties in Mach 3 and Mach 5 flows using filtered Rayleigh scattering. Filter properties have been characterized by high resolution spectroscopy in order to optimize the selection of laser frequency and filter operating conditions, as well as for the development of an accurate filter modeling program. An optimized filter is used the background suppression feature of this technique to image the boundary layer structure in a Mach 3 high Reynolds number facility and the shock structure in a Mach 5 overexpanded jet. This had been achieved using a visible laser source. By frequency scanning the laser, time-averaged velocity measurements in the Mach 3 and Mach 5 flows are made. Data acquisition at 10 torr and below indicates that this approach can be extrapolated for use in hypersonic flow facilities and is applicable as an in-flight optical air data device for hypersonic vehicles.

Miles, Richard B.↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Laser Calibration of an Impact Disdrometer

A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.

calibration↗

Visible and Infrared Imaging of Various Flow Regimes in the Flow Boiling and Condensation Experiment Transfer Line

The Flow Boiling and Condensation Experiment (FBCE) Transfer Line (TL) test module is being developed to study fluid physics of cryogenic transfer lines in microgravity. The TL module will reside in the FBCE facility located within the Fluids Integration Rack (FIR) aboard the International Space Station (ISS). TL will use the same normal perfluoro hexane (nPFH) used in the previous FBCE test sections. To simulate cryogenic line transfer in the visualization section, a sapphire tube coated with indium tin oxide (ITO) is heated via Joule heated while a bypass line is used to flow liquid nPFH at the desired inlet conditions. Once the visualization line reaches steady-state temperature and pressure conditions, flow is diverted through the heated line and chilldown begins. All flow regimes observed within a cryogenic TL are created and studied using visible imaging with diffuse backlighting to image inverted annular flow, transition, and nucleate boiling. A visible laser light sheet provided by FIR will provide a means to observe and track droplets in the dispersed flow regime. IR imaging of the visualization tube outer surface with the emissivity of the ITO coating provides the surface chilldown temperature profile. Preliminary imaging system development includes some of the components used in the Flow Boiling Module (FBM) and some new components that are easily integrated into the PC-based system but will require some refinement to operate properly on the FIR PCIe/104 imaging system. Optical design and packaging within the limited volume of the module enclosure is also presented. This paper presents FBCE-TL visible and infrared laboratory-based imaging studies and anticipated visualization capabilities of the TL module under preliminary breadboard development and under the utilization constraints within the FBCE/FIR host facility.

transfer line↗

Tracking System for Infrared Spectrometer

Visible laser tracking system for infrared laser spectometer keeps probe infrared laser beam aimed at moving reflector, thereby keeping reflector image and return laser beam within spectrometer field of view. System includes tracking mirror tilted by stepping motors under microprocessor control to deflect beams toward continually changing reflector position.

Johnson, R. A.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Measuring Two Key Parameters of H3 Color Centers in Diamond

A method of measuring two key parameters of H3 color centers in diamond has been created as part of a continuing effort to develop tunable, continuous-wave, visible lasers that would utilize diamond as the lasing medium. (An H3 color center in a diamond crystal lattice comprises two nitrogen atoms substituted for two carbon atoms bonded to a third carbon atom. H3 color centers can be induced artificially; they also occur naturally. If present in sufficient density, they impart a yellow hue.) The method may also be applicable to the corresponding parameters of other candidate lasing media. One of the parameters is the number density of color centers, which is needed for designing an efficient laser. The other parameter is an optical-absorption cross section, which, as explained below, is needed for determining the number density. The present method represents an improvement over prior methods in which optical-absorption measurements have been used to determine absorption cross sections or number densities. Heretofore, in order to determine a number density from such measurements, it has been necessary to know the applicable absorption cross section; alternatively, to determine the absorption cross section from such measurements, it has been necessary to know the number density. If, as in this case, both the number density and the absorption cross section are initially unknown, then it is impossible to determine either parameter in the absence of additional information.

Roberts, W. Thomas↗

Laser anemometer signals - Visibility characteristics and application to particle sizing

Investigations have been conducted concerning the characteristics of the visibility function as determined by the parameters of the laser anemometer system and the electromagnetic scattering properties of the particles. Experiments have been performed to evaluate the backscatter visibility of signals from a symmetric, s polarization laser anemometer as a function of the particle diameter and a parameter ratio. The results have been compared with the predictions of an analysis based on Mie's scattering theory. The analysis has also been used to evaluate the effects of the collecting aperture's size and location.

Adrian, R. J.↗

Modeling of growth, evaporation and sedimentation effects on transmission of visible and IR laser beams in artificial fogs

The dense polydisperse aerosol particles in a quiet chamber may spontaneously go through different microphysical processes including gravitational sedimentation, thermal coagulation, and growth or evaporation. In an earlier paper, we presented the results of a parametric study of the combined and separate effects of thermal coagulation and sedimentation on the time dependence of extinction of four visible and IR laser beams traversing an aerosol medium. As a continuation of this series of studies, the separate and combined effects of growth or evaporation and gravitational sedimentation on the time dependence of extinction of the same four visible and IR laser beams traversing in artificial fogs will be reported in this paper. The method of numerically modeling the change of water droplet size distribution with time due to growth/evaporation and the cutoff of larger aerosols due to gravitational sedimentation is described in detail. Factors governing the relative importance of these two processes are discussed. Results of this study show that the relative humidity or ambient temperature is a crucial parameter in determining the optical depth of the water droplet and aerosol media undergoing microphysical processes.

Yue, G. K.↗

High Resolution Surface Geometry and Albedo by Combining Laser Altimetry and Visible Images

The need for accurate geometric and radiometric information over large areas has become increasingly important. Laser altimetry is one of the key technologies for obtaining this geometric information. However, there are important application areas where the observing platform has its orbit constrained by the other instruments it is carrying, and so the spatial resolution that can be recorded by the laser altimeter is limited. In this paper we show how information recorded by one of the other instruments commonly carried, a high-resolution imaging camera, can be combined with the laser altimeter measurements to give a high resolution estimate both of the surface geometry and its reflectance properties. This estimate has an accuracy unavailable from other interpolation methods. We present the results from combining synthetic laser altimeter measurements on a coarse grid with images generated from a surface model to re-create the surface model.

Morris, Robin D.↗

Space Qualification of the Optical Filter Assemblies for the ICESat-2/ATLAS Instrument

The Advanced Topographic Laser Altimeter System (ATLAS) will be the only instrument on the Ice, Cloud, and Land Elevation Satellite -2 (ICESat-2). ICESat-2 is the 2nd-generation of the orbiting laser altimeter ICESat, which will continue polar ice topography measurements with improved precision laser-ranging techniques. In contrast to the original ICESat design, ICESat-2 will use a micro-pulse, multi-beam approach that provides dense cross-track sampling to help scientists determine a surface's slope with each pass of the satellite. The ATLAS laser will emit visible, green laser pulses at a wavelength of 532 nm and a rate of 10 kHz and will be split into 6 beams. A set of six identical, thermally tuned optical filter assemblies (OFA) will be used to remove background solar radiation from the collected signal while transmitting the laser light to the detectors. A seventh assembly will be used to monitor the laser center wavelength during the mission. In this paper, we present the design and optical performance measurements of the ATLAS OFA in air and in vacuum prior to their integration on the ATLAS instrument.

Etalons↗

Space Qualification of the Optical Filter Assemblies for the ICESat-2/ATLAS Instrument

The Advanced Topographic Laser Altimeter System (ATLAS) will be the only instrument on the Ice, Cloud, and Land Elevation Satellite -2 (ICESat-2). ICESat-2 is the 2nd-generation of the orbiting laser altimeter ICESat, which will continue polar ice topography measurements with improved precision laser-ranging techniques. In contrast to the original ICESat design, ICESat-2 will use a micro-pulse, multi-beam approach that provides dense cross-track sampling to help scientists determine a surface's slope with each pass of the satellite. The ATLAS laser will emit visible, green laser pulses at a wavelength of 532 nm and a rate of 10 kHz and will be split into 6 beams. A set of six identical, thermally-tuned etalon filter assemblies will be used to remove background solar radiation from the collected signal while transmitting the laser light to the detectors. A seventh etalon assembly will be used to monitor the laser center wavelength during the mission. In this paper, we present the design and optical performance measurements of the ATLAS optical filter assemblies (OFA) in air and in vacuum before integration on the ATLAS instrument.

Etalons↗

Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing

The simple addition of a charge-coupled-device (CCD) camera to a theodolite makes it safe to measure the pointing direction of a laser beam. The present state of the art requires this to be a custom addition because theodolites are manufactured without CCD cameras as standard or even optional equipment. A theodolite is an alignment telescope equipped with mechanisms to measure the azimuth and elevation angles to the sub-arcsecond level. When measuring the angular pointing direction of a Class ll laser with a theodolite, one could place a calculated amount of neutral density (ND) filters in front of the theodolite s telescope. One could then safely view and measure the laser s boresight looking through the theodolite s telescope without great risk to one s eyes. This method for a Class ll visible wavelength laser is not acceptable to even consider tempting for a Class IV laser and not applicable for an infrared (IR) laser. If one chooses insufficient attenuation or forgets to use the filters, then looking at the laser beam through the theodolite could cause instant blindness. The CCD camera is already commercially available. It is a small, inexpensive, blackand- white CCD circuit-board-level camera. An interface adaptor was designed and fabricated to mount the camera onto the eyepiece of the specific theodolite s viewing telescope. Other equipment needed for operation of the camera are power supplies, cables, and a black-and-white television monitor. The picture displayed on the monitor is equivalent to what one would see when looking directly through the theodolite. Again, the additional advantage afforded by a cheap black-and-white CCD camera is that it is sensitive to infrared as well as to visible light. Hence, one can use the camera coupled to a theodolite to measure the pointing of an infrared as well as a visible laser.

Crooke, Julie A.↗

Visual Alinement Technique for Infrared LIDAR

Visible He/Ne laser beam substituted for invisible CO2 beam during alinement. System accomplished visually by using low-power He/Ne laser previously adjusted to visible beam parallel to invisible infrared CO2 laser beam. Method used to aline adjacent telescopes in other optical systems.

Menzies, R. T.↗

Chemical-ionization visible and ultraviolet gas lasers: A concept

Charge-transfer reactions or Penning ionization reactions are used to produce population inversions between electronic states of molecular ions which should result in stimulated emission in ultraviolet and visible regions. Such lasers could be used in study of short-lived reaction intermediates, crystal structure and scattering, and photolysis.

Laudenslager, J. B.↗