Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events

An analytical, advanced imaging method has been developed for the initial monitoring and identification of foam debris and similar anomalies that occur post-launch in reference to the space shuttle s external tank (ET). Remote sensing technologies have been used to perform image enhancement and analysis on high-resolution, true-color images collected with the DCS 760 Kodak digital camera located in the right umbilical well of the space shuttle. Improvements to the camera, using filters, have added sharpness/definition to the image sets; however, image review/analysis of the ET has been limited by the fact that the images acquired by umbilical cameras during launch are two-dimensional, and are usually nonreferenceable between frames due to rotation translation of the ET as it falls away from the space shuttle. Use of stereo pairs of these images can enable strong visual indicators that can immediately portray depth perception of damaged areas or movement of fragments between frames is not perceivable in two-dimensional images. A stereoscopic image visualization system has been developed to allow 3D depth perception of stereo-aligned image pairs taken from in-flight umbilical and handheld digital shuttle cameras. This new system has been developed to augment and optimize existing 2D monitoring capabilities. Using this system, candidate sequential image pairs are identified for transformation into stereo viewing pairs. Image orientation is corrected using control points (similar points) between frames to place the two images in proper X-Y viewing perspective. The images are then imported into the WallView stereo viewing software package. The collected control points are used to generate a transformation equation that is used to re-project one image and effectively co-register it to the other image. The co-registered, oriented image pairs are imported into a WallView image set and are used as a 3D stereo analysis slide show. Multiple sequential image pairs can be used to allow forensic review of temporal phenomena between pairs. The observer, while wearing linear polarized glasses, is able to review image pairs in passive 3D stereo.

Brown, Richard↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

Airflow sensing system

Disclosed is an airflow sensing system for determining the type of airflow flowing over a flight surface. A hot film sensor is driven by a constant voltage feedback circuit that maintains the voltage across the sensor at a predetermined level. A signal processing circuit receives an output signal of the feedback circuit and determines whether the output signal is indicative of laminar, transitional or turbulent airflow. Transitional airflow is distinguished from turbulent airflow by a signal having significant energy in a low-frequency passband from 50-80 Hz. The signal processing circuit drives a three-color LED display to provide a visual indication of the type of airflow being sensed.

Gelbach, Herman R.↗

INS Nuclear Material Accounting and Control Instructional Video Materials- FY 25 Guides

This training video provides an essential guide to understanding and utilizing Tamper Indicating Devices (TIDs), with a specific focus on a common Mylar (Adhesive) variety during the application process. TIDs are a critical part of nuclear security, used to detect unauthorized access to sensitive materials or facilities. The Mylar (adhesive) TID employes a tamper-evident film integrated into the TID that visually indicates any tampering attempts. This video will explain how an example Mylar (adhesive) TID works, demonstrate proper installation techniques, and highlight how to interpret its indicators to ensure the security of nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cesium Batch Contact Equilibrium Testing of Crystalline Silicotitanate (CST) Sieve Cuts in SRS Average Simulant and Examination of CST Samples Aged in Caustic and Simulant in Support of Tank Closure Cesium Removal 1A (TCCR-1A)

Batch contact testing to determine cesium equilibrium loading on Crystalline Silicotitanate ion exchange media in Savannah River Site Average Waste Simulant at 25 °C indicated that smaller diameter particles isolated by sieving pretreated CST media may load slightly higher (<10%) amounts of cesium, though the differences are within analytical uncertainty. In addition, ion exchange media sub-samples stored in 2-4 M NaOH and caustic simulant solutions for ~2.5 years were examined by optical microscopy and the 3 M NaOH sample was also analyzed to determine whether changes in the particle size distribution occurred during storage. No visual indications of particle attrition or agglomeration were observed for any sample. Particle size analysis indicated that a slight decrease occurred in the average particle diameter following contact with 3 M NaOH (541 µm average diameter versus 566 µm for the pretreated CST prior to contact). A small increase (from 0 to <0.5 wt. %) in the number of particles ranging from 271 and 322 µm was also observed for the CST sample contacted with 3 M NaOH relative to a sample of the original pretreated material. However, this small change could be due to sub-sampling differences or analytical uncertainty. It does not appear that small particles are formed to a significant degree during CST caustic contact or that small particles which do form (presumably from attrition of larger particles during pretreatment) load significantly more cesium than the bulk material. Minimal other negative consequences were observed associated with CST extended caustic or simulant contact, except for the tendency for more concentrated salt solutions to form some salt crystals which deposit on the media over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and apparatus for measuring frequency and phase difference

The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

Shores, Paul↗

Method and apparatus for measuring frequency and phase difference

A system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams 152 and 152A are directed toward a target 153 and corresponding beams 154 and 154A returning therefrom are detected. A digital difference circuit 110 forms a pulse train 66 from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display 144 are correlative to target position relative to beams 152 and 152A.

Kobayashi, Herbert S.↗

Avionics Configuration Assessment for Flightdeck Interval Management: A Comparison of Avionics and Notification Methods

Flightdeck Interval Management is one of the NextGen operational concepts that FAA is sponsoring to realize requisite National Airspace System (NAS) efficiencies. Interval Management will reduce variability in temporal deviations at a position, and thereby reduce buffers typically applied by controllers - resulting in higher arrival rates, and more efficient operations. Ground software generates a strategic schedule of aircraft pairs. Air Traffic Control (ATC) provides an IM clearance with the IM spacing objective (i.e., the TTF, and at which point to achieve the appropriate spacing from this aircraft) to the IM aircraft. Pilots must dial FIM speeds into the speed window on the Mode Control Panel in a timely manner, and attend to deviations between actual speed and the instantaneous FIM profile speed. Here, the crew is assumed to be operating the aircraft with autothrottles on, with autopilot engaged, and the autoflight system in Vertical Navigation (VNAV) and Lateral Navigation (LNAV); and is responsible for safely flying the aircraft while maintaining situation awareness of their ability to follow FIM speed commands and to achieve the FIM spacing goal. The objective of this study is to examine whether three Notification Methods and four Avionics Conditions affect pilots' performance, ratings on constructs associated with performance (workload, situation awareness), or opinions on acceptability. Three Notification Methods (alternate visual and aural alerts that notified pilots to the onset of a speed target, conformance deviation from the required speed profile, and reminded them if they failed to enter the speed within 10 seconds) were examined. These Notification Methods were: VVV (visuals for all three events), VAV (visuals for all three events, plus an aural for speed conformance deviations), and AAA (visual indications and the same aural to indicate all three of these events). Avionics Conditions were defined by the instrumentation (and location) used to present IM information to crews: (1) Integrated (IM information is embedded in extant PFD (Primary Flight Display), ND (Navigation Display), EICAS (Engine Indicating and Crew Alerting System) displays); (2) EFB_Aft (IM information is only supplied in an EFB and mounted in location similar to that for MITRE's UPS work); (3) EFB_Fore (IM information is only supplied in an EFB which is mounted more forward, under the side window), and (4) EFB_Aft plus use of an AGD (the same IM information is supplied in an EFB and on an AGD, both mounted in locations similar to that in MITRE's UPS work ). Twelve commercial pilot crews flew descent scenarios (VNAV Speed with the mode control panel (MCP) speed window open until flaps extended, then VNAV Path) in a commercial transport flight simulator with realistic visual scene and communications. The results of this study serve three practical aims: (1) contribute to the down-select of avionics configuration for future assessment of the ASTAR spacing algorithm at NASA; (2) provide information useful to the FAA Human Factors Division (ANG-C1)'s mission to identify issues pertinent to flight certification of, and flight standards; (3) identify methodological considerations in support of future FIM human-in-the-loop (HITL) investigations.

Latorella, Kara A.↗

A Simplified Instrument for Recording and Indicating Frequency and Intensity of Icing Conditions Encountered in Flight

An instrument for recording and indicating the frequency and intensity of aircraft icing conditions encountered in flight has been developed by the NACA Lewis Laboratory to obtain statistical icing data over world-wide air routes during routine airline operations. The operation of the instrument is based on the creation of a differential pressure between an ice-free total-pressure system and a total-pressure system in which small total-pressure holes vented to static pressure are allowed to plug with ice accretion. The simplicity of this operating principle permits automatic operation, and provides relative freedom from maintenance and operating problems. The complete unit weighing only 18 pounds records icing rate, airspeed, and altitude on photographic film and provides visual indications of icing intensity to the pilot.

ICE FORMATION↗

A High Energy–Density, Cobalt–Free, Low–Nickel LiNi 0.7 Mn 0.25 Al 0.05 O 2 Cathode with a High–Voltage Electrolyte for Lithium–Metal Batteries

Cobalt-free cathode materials have garnered increased attention for applications in next-generation batteries for electric vehicles, as cobalt is considered to have at a high supply chain risk. Here, the use of a localized saturated electrolyte (LSE) to enable stable cycling of a cobalt-free, low-nickel layered-oxide cathode LiNi 0.7 Mn 0.25 Al 0.05 O 2 (NMA-70) to higher voltages (4.6 V) in a lithium-metal battery is demonstrated. Compared to the baseline LP57 electrolyte, the LSE extends the cycle life from ≈100 cycles to ≈400 cycles before reaching 80% capacity retention. Visual indicators of cell degradation, such as product deposition, are observed on electrodes cycled in LP57. It is shown that cycling NMA-70 in LSE reduces the overall active material loss and overpotential growth during extended cycling. This is attributed to the formation of a beneficial fluorinated interphase layer, a lower degree of rock-salt phase formation, and a reduction in the gas evolution from the cathode surface. The decrease in gas evolution from the cathode cycled in LSE reflects a lower degree of electrolyte reactivity and an overall improvement in the safety characteristics of the cell. Furthermore, this study highlights the importance of a stable electrolyte to enable the high-voltage cycling of alternative, lower nickel, and cobalt-free cathodes.

25 ENERGY STORAGE↗

Predicting chatter using machine learning and acoustic signals from low-cost microphones

Machining chatter is a phenomenon resulting from self-oscillation between a machining tool and workpiece. This self-oscillation results in variation on the machined product that reduces the ability to meet desired specifications. Chatter is a widely studied topic as it directly relates to the quality of machined products. Here, this study details the application of a Random Forest (RF) classifier with Recursive Feature Elimination (RFE) to machining audio collected by a single microphone during down-milling operations. This approach allows straightforward feature elimination that results in an easily understood set of analyzed dimensions. Stability is predicted solely based on the classification output of the RF classifier. Our approach proves highly predictive with consistent machining setup and a small sample set. We also review transferability between machining setups and present key findings. Our RF approach demonstrates the ability to analyze and classify chatter through a low-cost approach with limited training data required. The motivation for using a single microphone is to enable detection on machines without other sensors, such as accelerometers, present in the machining setup. The value of the in-process sensor and chatter classifier is highlighted because the machining setup included asymmetric dynamics that reduced the accuracy of the traditional analytical stability solution. We see a natural progression to deploying this audio-only methodology with real-time processing and classification using either a laptop or smartphone. This progression will allow visual indicators during the machining process that can alert machinists of progression into unstable machining processes.

42 ENGINEERING↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

An efficient virus–induced gene silencing (VIGS) system for gene functional studies in Miscanthus

Virus-induced gene silencing (VIGS) is a powerful tool for transient gene functional analysis in plants, especially for monocot species (e.g., grasses) that are recalcitrant to transformation. Despite various VIGS systems that have been developed in different plant species, none was previously available for the bioenergy crop Miscanthus. Here, we report the establishment of an efficient and robust VIGS system mediated by Tobacco Rattle Virus (TRV) in Miscanthus. We first investigated the impact of various factors that may affect gene silencing efficiency using the Miscanthus sinensis Phytoene Desaturase (MsPDS) gene as a visual indicator of photobleaching. Then, we optimized the TRV-elicited VIGS procedure using an orthogonal experimental design with four factors (sprout size, Agrobacterium concentration, vacuum infiltration time, and co-incubation time) each at three levels. The following led to the highest silencing efficiency (~76%): inoculation of germinating seedlings (1.0–2.0 mm), Agrobacterium tumefaciens culture grown to optical density at 600 nm (OD 600 ) of 0.4, vacuum infiltration for 90 min, and co-incubation for 5 h. The VIGS system established was applicable for both M. sinensis and M. lutarioriparius, with comparable gene silencing efficiency. We verified the efficacy of the VIGS system via the functional characterization of the role of a MYB transcription factor, MsMYB112, in salt stress tolerance. Expression of MsMYB112 was successfully knocked down using the VIGS system, and this led to compromised salt tolerance in the silenced Miscanthus plants. The TRV-based VIGS system established may, therefore, substantially facilitate functional genomic studies in Miscanthus.

60 APPLIED LIFE SCIENCES↗

Self-Sensing Fiber Reinforced Composite (CRADA Final Report)

The project aimed to demonstrate a scalable coating process to adhere nanoparticles to the surface of fibers and fabricate composites with in-situ damage detection abilities and simultaneous mechanical performance enhancements. Carbon fiber (CF) composites have the inherent problem of hiding damage within the structure with no visual indications on the surface. Therefore, a technique to monitor for damage or excessive stress on the composite is necessary to ensure its safety and avoid catastrophic failure. This capability will be desired in future transportation vehicle designs, such as in cargo and surveillance drones developed by Dronesat, LLC, (Dronesat) who was the industrial partner on this project.

36 MATERIALS SCIENCE↗

Puck Loop Seal (Final Project Technical Report)

Sandia National Laboratories (SNL) is advancing technical capabilities used in passive loop seals. The “Puck” seal used a set of International Atomic Energy Agency (IAEA) requirements for new passive loop seals published in 2020 as a design guide. The seal is based on an oxygen-sensitive inner mixture encased in an oxygen-impermeable shell, is monolithic rather than two-part, incorporates self-capturing wire features, contains colored water beads and bubbles formed during processing as unique identifiers (UIDs), and visually indicates tamper (whether from seal body penetration or from seal wire removal) by irreversibly changing the seal body from multi-colored to black. This paper will provide details on the design, development, and testing of Puck seal prototypes.

42 ENGINEERING↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗