Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage and current controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tethered system/space platform integration - TSS lessons learned

Tethered spacecraft systems must be integrated with their user platforms in a way that allows both to carry out their design functions efficiently and safely. This paper describes the lessons learned about tethered system integration with a space platform from the NASA/PSN Tethered Satellite System. Items discussed include platform attitude control, induced voltage and current control, satellite tracking and tether length measurement, satellite communications and system operations sensitivities. A number of engineering issues yet to be resolved are noted. Tethered systems are complex and require careful design to ensure successful operation.

Rudolph, L. K.↗

Matrix converter operation in current control mode with regulation of output voltage vector

A matrix converter system having a current control mode operation is provided. The matrix converter system includes a matrix converter that includes a plurality of switches. A unity current reference vector having an amplitude of one is determined that defines an angle and frequency of an output current vector as a function of a reference phase angle, which is a function of the output current vector and an output voltage vector representing feedback signals of a multiphase signal output to a load. The unity current reference vector is used to control the matrix converter, to cause the output current vector to be aligned with the unity current reference vector. A unity voltage reference vector having an amplitude of one is provided that defines a reference angle and frequency as a function of a zero phase angle. The output voltage vector and the unity voltage reference vector are aligned to determine the reference phase angle as an angle between the aligned output voltage vector and the output current vector.

42 ENGINEERING↗

Three-phase Four-leg Inverter LabVIEW FPGA Control Code [SWR-16-26]

In the area of power electronics control, Field Programmable Gate Arrays (FPGAs) have the capability to outperform their Digital Signal Processor (DSP) counterparts due to the FPGA’s ability to implement true parallel processing and therefore facilitate higher switching frequencies, higher control bandwidth, and/or enhanced functionality. National Instruments (NI) has developed two platforms, Compact RIO (cRIO) and Single Board RIO (sbRIO), which combine a real-time processor with an FPGA. The FPGA can be programmed with a subset of the well-known LabVIEW graphical programming language. The use of cRIO and sbRIO for power electronics control has developed over the last few years to include control of three-phase inverters. Most three-phase inverter topologies include three switching legs. The addition of a fourth-leg to natively generate the neutral connection allows the inverter to serve single-phase loads in a microgrid or stand-alone power system and to balance the three-phase voltages in the presence of significant load imbalance. However, the control of a four-leg inverter is much more complex. In particular, instead of standard two-dimensional space vector modulation (SVM), the inverter requires three-dimensional space vector modulation (3D-SVM). The candidate software implements complete control algorithms in LabVIEW FPGA for a three-phase four-leg inverter. The software includes feedback control loops, three-dimensional space vector modulation gate-drive algorithms, advanced alarm handling capabilities, contactor control, power measurements, and debugging and tuning tools. The feedback control loops allow inverter operation in AC voltage control, AC current control, or DC bus voltage control modes based on external mode selection by a user or supervisory controller. The software includes the ability to synchronize its AC output to the grid or other voltage-source before connection. The software also includes provisions to allow inverter operation in parallel with other voltage regulating devices on the AC or DC buses. This flexibility allows the Inverter to operate as a stand-alone voltage source, connected to the grid, or in parallel with other controllable voltage sources as part of a microgrid or remote power system. In addition, as the inverter is expected to operate under severe unbalanced conditions, the software includes algorithms to accurately compute real and reactive power for each phase based on definitions provided in the IEEE Standard 1459: IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions. Finally, the software includes code to output analog signals for debugging and for tuning of control loops. The software fits on the Xilinx Virtex V LX110 FPGA embedded in the NI cRIO-9118 FPGA chassis, and with a 40 MHz base clock, supports a modulation update rate of 40 MHz, user-settable switching frequencies and synchronized control loop update rates of tens of kHz, and reference waveform generation, including Phase Lock Loop (PLL), update rate of 100 kHz.

Martin, Gregory↗

Optimal Submodule Capacitor Sizing for Modular Multilevel Converters with Common Mode Voltage Injection and Circulating Current Control

Abstract - Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, at low frequencies (< 30 Hz), a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes an optimal submodule capacitor selection based on the common mode voltage injection. The proposed sizing model includes two functions: a) accurately estimating the capacitor voltage ripple based on the drive system parameters; and b) identifying the minimum capacitance of the submodule capacitors based on the allowed maximum capacitor voltage fluctuations. Simulation and hardware-in-the-loop (HIL) test results show that the error between the actual and estimated values of the voltage fluctuation is within 3% using the proposed model.

Capacitor Sizing↗

Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control

In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.

Thapa, Anup↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Analysis and Characterization of Four-quadrant Switches based Commutation Cell

A four-quadrant switch (FQS) blocks either polarity voltage and controls current flow in both directions. Unlike voltage-source converters, in which two-quadrant switches operate over a narrow voltage range, four-quadrant switches are required to operate over a wide range of both voltage and current in applications such as matrix converters and current-source converters. Furthermore, matrix converters require multi-step commutation schemes compared to two-step schemes for current-bidirectional switch based voltage-source converters and voltage-bidirectional switch based current-source converters. This paper provides a generalized overview of commutation schemes used for two and four quadrant switches based two-level commutation cells, identifies comparison indices for FQS commutation schemes, and discusses the need for adaptive commutation-step times for wide voltage and current variation applications. Also, the static and dynamic characteristics of 1.2 kV rated FQS implementations utilizing commercial SiC MOSFETs from four different manufacturers and novel monolithic SiC BiDirectional Field Effect Transistor (BiDFET) have been reported.

Commutation cell, four quadrant switch, SiC Bidire↗

Synchronized Waveforms – A Frontier of Data-Based Power System and Apparatus Monitoring, Protection, and Control

Voltage and current waveforms contain the most authentic and granular information on the behaviors of power systems. In recent years, it has become possible to synchronize waveform data measured from different locations. Thus large-scale coordinated analyses of multiple waveforms over a wide area are within our reach. This development could unleash a set of new concepts, strategies, and tools for monitoring, protecting, and controlling power systems and apparatuses. This paper presents an in-depth review and analysis of the advancements in synchronized waveform data, including measurement devices, data characteristics, use cases, and comparisons with synchrophasor data. Based on the findings, five strategies are proposed to discover and develop synchronized waveform based applications over multiple application areas. The paper also presents three complementary measurement platforms and two data screening algorithms for application implementation. It further discusses committee activities and standard developments useful to explore the full potential of the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Degradation of AlGaN/GaN high-electron mobility transistors in the current-controlled off-state breakdown

We investigate degradation mechanisms in AlGaN/GaN HEMTs which were repeatedly driven into the current-controlled off-state breakdown or subject to 60 s voltage- or current-controlled off state stresses. The current-controlled sweep in to the breakdown allows the sustainability of breakdown that can not be observed in the voltage controlled sweep. Only temporal changes were observed in the HEMT dc performance after repetitive sweeps, which were explained by charging/discharging of the HEMT surface at the gate-to-drain access region and in the GaN buffer below the gate. Similar changes were observed also if high-voltage stress has been applied on the drain; however, permanent degradation appears after 60 s current-controlled breakdown stress. In this case, the drain leakage current, as well as the breakdown current, increases significantly. On the other hand, the breakdown voltage, as well as the gate characteristics, remains unaltered. We suggest that the avalanche-injection process is governing the off-state breakdown event with a dominant role of the potential barrier at the channel-buffer interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of Battery Charge Controller Technologies for Wave Energy Converters

Wave energy is a uniquely challenging field for electrical system designers. High peak and low average power potential with a constantly varying energy input is difficult to harness and control through conventional means. To power the blue economy, low-powered wave energy converters (WECs) need batteries for energy storage. Safely and effectively charging batteries from waves requires a charge controller to properly monitor and control voltage and current going to the battery. Currently, off-the-shelf charge controllers exist for other renewable generation such as wind, hydro, and solar. Two topologies were validated: a buck converter and a pulse width modulation (PWM) charge controller. Using an in-lab dry testbed, wave energy power inputs were simulated to properly validate the effectiveness of existing charge controller technologies, identifying the shortcomings and improvements needed to effectively harness wave energy.

battery storage↗

A Comparison of Battery Charge Controller Technologies for Wave Energy Converters: Preprint

Wave energy is a uniquely challenging field for electrical system designers. High peak and low average power potential with a constantly varying energy input is difficult to harness and control through conventional means. To power the blue economy, low-powered wave energy converters (WECs) need batteries for energy storage. Safely and effectively charging batteries from waves requires a charge controller to properly monitor and control voltage and current going to the battery. Currently, off-the-shelf charge controllers exist for other renewable generation such as wind, hydro, and solar. Two topologies were validated: a buck converter and a pulse width modulation (PWM) charge controller. Using an in-lab dry testbed, wave energy power inputs were simulated to properly validate the effectiveness of existing charge controller technologies, identifying the shortcomings and improvements needed to effectively harness wave energy.

battery storage↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Design of a battery charger for the NASA EOS space platform

A battery charger design for the NASA Earth Observing System (EOS) space platform has been developed and tested. The authors discuss the design of the battery charger power state and its current and voltage control loops. In addition to restoring energy to the batteries, this charger regulates the spacecraft bus voltage during the posteclipse transition period. The battery charger design and analysis were facilitated by use of the pulse-width-modulated (PWM) switch model and the new continuous-time model for current-mode control. Analyses of the battery charger small-signal behavior are compared to hardware measurements to verify modeling accuracy.

Sizemore, Tom↗