A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗

Swarm Intelligence Based Optimal Design of Local Volt/Var Control Function for Distributed Energy Resources

The increasing penetration of renewable based distributed energy resources (DERs) in distribution network (DN) leads to larger and more frequent voltage variation in distributions network (DN), thus posing challenges on voltage control. Real-time local voltage control method is a promising solution for the above issue. However, the local voltage control function needs to be customized and optimized according to real distribution system condition. In this paper, a swarm intelligence based Volt/Var control optimal design method (SO-VVC) is proposed to optimize the control function. Compared with existing approaches, the proposed method can not only represent the nonlinear behaviour of power flow but is also computation efficient. The performance of the proposed SO-VVC is demonstrated by case studies on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS↗

Tunnel junction-enabled monolithically integrated GaN micro-light emitting transistor

GaN/InGaN microLEDs are a very promising technology for next-generation displays. Switching control transistors and their integration are key components in achieving high-performance, efficient displays. Monolithic integration of microLEDs with GaN switching devices provides an opportunity to control microLED output power with capacitive (voltage)-controlled rather than current-controlled schemes. This approach can greatly reduce system complexity for the driver circuit arrays while maintaining device opto-electronic performance. In this work, we demonstrate a 3-terminal GaN micro-light emitting transistor that combines a GaN/InGaN blue tunneling-based microLED with a GaN n-channel FET. Further, the integrated device exhibits excellent gate control, drain current control, and optical emission control. This work provides a promising pathway for future monolithic integration of GaN FETs with microLED to enable fast switching, high-efficiency microLED display and communication systems.

42 ENGINEERING↗

Prospects for Antiferromagnetic Spintronic Devices

This article examines recent advances in the field of antiferromagnetic spintronics from the perspective of potential device realization and applications. We discuss advances in the electrical control of antiferromagnetic order by current-induced spin–orbit torques, particularly in antiferromagnetic thin films interfaced with heavy metals. We also review possible scenarios for using voltage-controlled magnetic anisotropy as a more efficient mechanism to control antiferromagnetic order in thin films with perpendicular magnetic anisotropy. Next, we discuss the problem of electrical detection (i.e., readout) of antiferromagnetic order and highlight recent experimental advances in realizing anomalous Hall and tunneling magnetoresistance effects in thin films and tunnel junctions, respectively, which are based on noncollinear antiferromagnets. Understanding the domain structure and dynamics of antiferromagnetic materials is essential for engineering their properties for applications. For this reason, we then provide an overview of imaging techniques as well as micromagnetic simulation approaches for antiferromagnets. Finally, we present a perspective on potential applications of antiferromagnets for magnetic memory devices, terahertz sources, and detectors.

36 MATERIALS SCIENCE↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Final Technical Report of a Feasibility Investigation of a Hydropower Flexibility Upgrade Kit

The project studied the feasibility of a concept for a flexibility upgrade kit called h-Dynamyk to improve the flexibility of U.S. hydropower plants and assessed its potential impact on the U.S. hydropower industry. This concept addresses the growing need for grid flexibility amid rising renewable energy adoption, such as wind and solar, which often introduce intermittency. The upgrade kit is intended to address challenges posed by aging turbine designs in meeting modern grid demands for flexibility services like frequency response, voltage control, spinning reserve, and black-start capabilities. Key features of the h-Dynamyk kit include siphon turbine assemblies, medium-voltage variable frequency drives (VFDs), and smart controls integrated with plant systems to optimize operations and extend equipment life. This nine-month discovery project successfully achieved its objectives by defining a baseline design and performance metrics for the h-Dynamyk flexibility upgrade kit, analyzing this baseline, and incorporating lessons learned from this analysis into a modified set of metrics and recommendations for future design and testing, which were further guided by field site studies.

13 HYDRO ENERGY↗

Magnetic order in nanogranular iron germanium (Fe 0.53 Ge 0.47 ) films

We study the effect of strain on the magnetic properties and magnetization configurations in nanogranular Fe x Ge 1-x films (x = 0.53 ± 0.05) with and without B20 FeGe nanocrystals surrounded by an amorphous structure. Relaxed films on amorphous silicon nitride membranes reveal a disordered skyrmion phase while films near and on top of a rigid substrate favor ferromagnetism and an anisotropic hybridization of Fe d levels and spin-polarized Ge sp band states. The weakly coupled topological states emerge at room temperature and become more abundant at cryogenic temperatures without showing indications of pinning at defects or confinement to individual grains. These results demonstrate the possibility to control magnetic exchange and topological magnetism by strain and inform magnetoelasticity-mediated voltage control of topological phases in amorphous quantum materials.

36 MATERIALS SCIENCE↗