Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. D.↗

The effect of a defective BSF layer on solar cell open circuit voltage

A straightforward analysis of special limiting cases has permitted the determination of the range of possible open circuit voltage losses due to a defective BSF (back surface field) layer. An important result of the analysis is the finding that it is possible to have a fully effective BSF region, regardless of the spatial distribution of the defective areas, as long as the total defective area is reduced below certain limits. Distributed defects were found to be much more harmful than lumped defects.

Weizer, V. G.↗

J series thruster isolator failure analysis

Three Hg propellant isolators (two cathode and one main) failed during testing in the Mission Profile Life Test. These failures involved contamination of the surface of the alumina insulating body which resulted in heating of the vaporizer by leakage current from the high voltage supply, with subsequent loss of propellant flow rate control. Failure analysis of the isolators showed the surface resistance was temperature dependent and that the alumina could be restored to its original insulating state by grit blasting the surface. The contaminant was identified as carbon and the most likely sources identified as ambient facility hydrocarbons, directed back-sputtered facility materials, and outgassing from organic insulating materials within the thruster envelope. Methods to eliminate contamination from each of these sources are described.

Campbell, J. W.↗

A Sensorless Coil Detection Scheme based on Dead-Time Effect in Dynamic Wireless Power Transfer Systems

The detection of electric vehicles in dynamic wireless power transfer (DWPT) systems is important to reduce the standby losses and comply with the electromagnetic-field emission guidelines recommended by the International Commission for Non-Ionizing Radiation Protection. This paper discusses a novel sensorless coil detection scheme, which exploits the phenomenon of voltage-polarity reversal/notches caused by the dead-time effect in the full-bridge inverter. The variations in the system impedance and dead-time effects are collectively exploited to detect the receiver coil in the DWPT system. The proposed coil detection scheme is accomplished at low excitation voltage, which reduces the inverter standby losses. The theoretical analysis of the notch occurrence and open-loop simulation results are presented using a DWPT model developed in the piecewise linear electrical circuit simulation software.

Kavimandan, Utkarsh↗

An Analysis of the Impact of Particle Growth on Transport Losses in Polymer-Electrolyte Fuel Cells

Voltage cycling causes catalyst nanoparticles in polymer-electrolyte fuel cells to grow. The concomitant loss of interfacial area results in larger kinetic, transport, and possibly ohmic overpotentials. This paper uses recently published experimental data and mathematical models to investigate the evolutions of transport and ohmic resistances to platinum nanoparticles located on the surface and inside the micropores of carbon black supports. Resistance to oxygen transport rises as surface area declines primarily because the flux to each remaining larger platinum particle increases. The path lengths governing oxygen diffusion to surface and buried platinum sites also increase as nanoparticles grow. Platinum nanoparticles on the surface become relatively less favorable as voltage cycling proceeds because they grow faster than platinum in micropores. Because voltage cycling causes total interfacial area to decline, and the fraction located inside micropores to increase, nanoscale ohmic losses increase as a catalyst layer decays. The practical importance of this effect is difficult to discern because proton conductivity in carbon micropores is not well characterized.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Voltage-Matched Strings using 3-Terminal Tandems: Fundamentals and End Losses

Strings constructed from 3-terminal tandem (3TT) cells can provide some of the performance benefits of voltage-matching with less cell complexity than strings based on 4-terminal tandem cells. However, the circuitry for a 3TT string can become more complex, making circuit analysis more challenging. Here we illustrate the essential features of single-polarity voltage-matched (VM) 3TT strings using representative examples. End losses are intrinsic to this type of string, but can be reduced by minimizing m and n in the Vtop/Vbot VM ratio m/n, and further mitigated by increasing the string length. This analysis agrees with preliminary experimental results.

3TT↗

Evaluating the Effects of Anode Porous Transport Layer on the Performance and Durability of Anion Exchange Membrane Electrolyzers

As anion exchange membrane systems have emerged as a competitive low temperature electrolysis technology, research has expanded to other components and device integration. In this study, nickel (Ni) and stainless steel (SS)-based porous transport layers (PTLs) are investigated in membrane electrode assemblies (MEAs). Compared to MEAs using Ni, the SS PTL shows higher performance due to less kinetics and residual loss and possibly due to a combination of iron mobility improving oxygen evolution reactivity and electron conduction pathways, as well as higher porosity increasing site access. Voltage decay rates of approximately 144 and 115 μV/h, respectively, for the Ni and SS PTLs are found, although the long-term durability and lifetime implications are convoluted. Voltage breakdown analysis confirms that both PTLs saw significant increases in residual loss possibly due to catalyst/PTL property changes that affected electronic, ionic, and mass transport pathways. For the Ni PTL, a higher proportion of the losses were due to cell kinetics; comparatively, more of the SS PTL losses were due to increases in the high frequency resistance. The experimental findings presented here provide insights on the impact of the PTL materials and their properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Planning and Operation of Multi-Frequency HVac Transmission Systems

Low-frequency high-voltage alternating-current (LF-HVac) transmission scheme has been recently proposed as an alternative solution to conventional 50/60-Hz HVac and high-voltage direct-current (HVdc) schemes for bulk power transfer. This paper proposes an optimal planning and operation for loss minimization in a multi-frequency HVac transmission system. In such a system, conventional HVac and LF-HVac grids are interconnected using back-to-back (BTB) converters. The dependence of system MW losses on converter dispatch as well as the operating voltage and frequency in the LF-HVac is discussed and compared with that of HVdc transmission. Based on the results of the loss analysis, multi-objective optimization formulations for both planning and operation stages are proposed. The planning phase decides a suitable voltage level for the LF-HVac grid, while the operation phase determines the optimal operating frequency and power dispatch of BTB converters, generators, and shunt capacitors. A solution approach that effectively handles the variations of transmission line parameters with the rated voltage and operating frequency in the LF-HVac grid is proposed. The proposed solutions of the planning and operation stages are evaluated using a multi-frequency HVac system. The results show a significant loss reduction and improved voltage regulation during a 24-hour simulation.

Nguyen, Quan H.↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗

The potential of np GaAs solar cells for high efficiency concentrator applications

This communication considers the design of the front grid contact of np GaAs solar cells for high efficiency concentrator applications. This design involves shadowing, contact resistance, and active layer sheet resistance losses, and at high concentrations, the power loss due to voltage drop on the resistance of the grid fingers should be considered. Analysis of the performance can be calculated as a function of junction depth and surface recombination velocity. The junction depth can be optimized by considering its effect on the collection efficiency of the dark current-voltage characteristics or the open circuit voltage, and on the series resistance loss or the fill factor for material parameters. The choice of the material parameters, calculation of the short circuit current, the selection of the n layer thickness, and the cell maximum power and efficiency are discussed. It is concluded that optimized multi-grid structures should allow the use of 10 by 10 sq cm cells with good efficiencies at high concentration ratios, and efficiencies of 22 to 25% should be obtainable from large area cells at concentrations of 40 AM1.

Flat, A.↗

Multilevel Switched-Capacitor AC–DC Step-Down Rectifier for Wireless Charging With Reduced Conduction Loss and Harmonic Content

In this paper, a wireless charging architecture employing a multilevel switched-capacitor (MSC) AC-DC rectifier is investigated. The proposed MSC rectifier features a multilevel design which is scalable to accommodate different power ratings and load ranges. The topology showcases advantages for wireless power transfer (WPT) systems in terms of compactness, efficiency, impedance tunability, and harmonic attenuation. The single-stage active topology is capable of varying its low-distortion staircase input voltage to tune the wireless power transfer system for high system-wide efficiency. A 7-level, 20 W prototype is used to verify the WPT loading and loss analysis. The prototype operates at 150 kHz with up to 3:1 step-down conversion ratio to an output voltage of 5.0 V. The experimental peak DC-to-DC efficiency is 93.8% and the rectifier peak efficiency is 98.3%. As a result. the rectifier demonstrates low waveform distortion and high efficiency across many WPT loading conditions, solidifying its place as a strong candidate for wireless power applications.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Measurements of Single Event Upset in ATLAS IBL

Effects of Single Event Upsets (SEU) and Single Event Transients (SET) are studied in the FE-I4B chip of the innermost layer of the ATLAS pixel system. SEU/SET affect the FE-I4B Global Registers as well as the settings for the individual pixels, causing, among other things, occupancy losses, drops in the low voltage currents, noisy pixels, and silent pixels. Quantitative data analysis and simulations indicate that SET dominate over SEU on the load line of the memory. Operational issues and mitigation techniques are presented.

47 OTHER INSTRUMENTATION↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗