Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Voltage-Matched Strings using 3-Terminal Tandems: Fundamentals and End Losses

Strings constructed from 3-terminal tandem (3TT) cells can provide some of the performance benefits of voltage-matching with less cell complexity than strings based on 4-terminal tandem cells. However, the circuitry for a 3TT string can become more complex, making circuit analysis more challenging. Here we illustrate the essential features of single-polarity voltage-matched (VM) 3TT strings using representative examples. End losses are intrinsic to this type of string, but can be reduced by minimizing m and n in the Vtop/Vbot VM ratio m/n, and further mitigated by increasing the string length. This analysis agrees with preliminary experimental results.

3TT↗

Evaluating the Effects of Anode Porous Transport Layer on the Performance and Durability of Anion Exchange Membrane Electrolyzers

As anion exchange membrane systems have emerged as a competitive low temperature electrolysis technology, research has expanded to other components and device integration. In this study, nickel (Ni) and stainless steel (SS)-based porous transport layers (PTLs) are investigated in membrane electrode assemblies (MEAs). Compared to MEAs using Ni, the SS PTL shows higher performance due to less kinetics and residual loss and possibly due to a combination of iron mobility improving oxygen evolution reactivity and electron conduction pathways, as well as higher porosity increasing site access. Voltage decay rates of approximately 144 and 115 μV/h, respectively, for the Ni and SS PTLs are found, although the long-term durability and lifetime implications are convoluted. Voltage breakdown analysis confirms that both PTLs saw significant increases in residual loss possibly due to catalyst/PTL property changes that affected electronic, ionic, and mass transport pathways. For the Ni PTL, a higher proportion of the losses were due to cell kinetics; comparatively, more of the SS PTL losses were due to increases in the high frequency resistance. The experimental findings presented here provide insights on the impact of the PTL materials and their properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Planning and Operation of Multi-Frequency HVac Transmission Systems

Low-frequency high-voltage alternating-current (LF-HVac) transmission scheme has been recently proposed as an alternative solution to conventional 50/60-Hz HVac and high-voltage direct-current (HVdc) schemes for bulk power transfer. This paper proposes an optimal planning and operation for loss minimization in a multi-frequency HVac transmission system. In such a system, conventional HVac and LF-HVac grids are interconnected using back-to-back (BTB) converters. The dependence of system MW losses on converter dispatch as well as the operating voltage and frequency in the LF-HVac is discussed and compared with that of HVdc transmission. Based on the results of the loss analysis, multi-objective optimization formulations for both planning and operation stages are proposed. The planning phase decides a suitable voltage level for the LF-HVac grid, while the operation phase determines the optimal operating frequency and power dispatch of BTB converters, generators, and shunt capacitors. A solution approach that effectively handles the variations of transmission line parameters with the rated voltage and operating frequency in the LF-HVac grid is proposed. The proposed solutions of the planning and operation stages are evaluated using a multi-frequency HVac system. The results show a significant loss reduction and improved voltage regulation during a 24-hour simulation.

Nguyen, Quan H.↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗

Identification of Recombination Losses in CdSe/CdTe Solar Cells from Spectroscopic and Microscopic Time-Resolved Photoluminescence

Due to the lowest-cost and best reliability, CdTe solar cells are the leading thin-film photovoltaic technology. Increasing open-circuit voltage by reducing recombination represents the most promising path toward further improvements. Analysis is needed to identify limitations that cause efficiency losses. To achieve this goal for Cu-doped CdSe/CdTe solar cells, time-resolved spectroscopy and microscopy are developed and applied. Recombination lifetimes and radiative efficiency identify that defect-mediated recombination is the dominant voltage loss mechanism. When carrier lifetimes are averaged over many crystalline grains, they increase from 180 to 430 ns when Al2O3 is applied to the back contact. The quasi-Fermi-level splitting correspondingly increases from 880–905 to 906–931 mV, indicating a pathway to overcome the long-standing 900 mV voltage limitation. However, the dominant recombination losses are attributed to the absorber bulk. From microscopic carrier lifetime measurements, it is identified that space charge fields due to charged grain boundaries (GBs) lead to recombination in the CdTe absorber bulk. At high injection, GB space charge fields are screened, but that occurs above 1 Sun excitation conditions. Alloying with selenium in the near-interface CdSeTe absorber region reduces GB losses and is identified as one of the factors leading to high radiative and power conversion efficiency.

14 SOLAR ENERGY↗

Multilevel Switched-Capacitor AC–DC Step-Down Rectifier for Wireless Charging With Reduced Conduction Loss and Harmonic Content

In this paper, a wireless charging architecture employing a multilevel switched-capacitor (MSC) AC-DC rectifier is investigated. The proposed MSC rectifier features a multilevel design which is scalable to accommodate different power ratings and load ranges. The topology showcases advantages for wireless power transfer (WPT) systems in terms of compactness, efficiency, impedance tunability, and harmonic attenuation. The single-stage active topology is capable of varying its low-distortion staircase input voltage to tune the wireless power transfer system for high system-wide efficiency. A 7-level, 20 W prototype is used to verify the WPT loading and loss analysis. The prototype operates at 150 kHz with up to 3:1 step-down conversion ratio to an output voltage of 5.0 V. The experimental peak DC-to-DC efficiency is 93.8% and the rectifier peak efficiency is 98.3%. As a result. the rectifier demonstrates low waveform distortion and high efficiency across many WPT loading conditions, solidifying its place as a strong candidate for wireless power applications.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Measurements of Single Event Upset in ATLAS IBL

Effects of Single Event Upsets (SEU) and Single Event Transients (SET) are studied in the FE-I4B chip of the innermost layer of the ATLAS pixel system. SEU/SET affect the FE-I4B Global Registers as well as the settings for the individual pixels, causing, among other things, occupancy losses, drops in the low voltage currents, noisy pixels, and silent pixels. Quantitative data analysis and simulations indicate that SET dominate over SEU on the load line of the memory. Operational issues and mitigation techniques are presented.

47 OTHER INSTRUMENTATION↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗

Homogenous Voltage-Matched Strings Using Three-Terminal Tandem Solar Cells: Fundamentals and End Losses

Strings constructed from three-terminal tandem (3TT) solar cells offer the performance benefits of voltage-matching (which reduces sensitivity to spectral variation), but without the subcell voltage isolation required by four-terminal cells. However, the circuitry for a 3TT string can become complex, making circuit analysis more challenging. Here, we illustrate the essential features of “homogenous” voltage-matched (VM) 3TT strings, for which all 3TT cells in the string are nominally identical (with the same design/doping sequence, such that they can be fabricated on the same manufacturing line). Several representative VM string configurations are explicitly considered, and used to describe the general construction of string I(V) curves. End losses intrinsic to these strings are discussed in detail, along with mitigation strategies to minimize their impact. Our analysis agrees with experimental results for eight-cell strings constructed from GaInP/GaAs 3TT devices.

14 SOLAR ENERGY↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗

On the Interplay between CT and Singlet Exciton Emission in Organic Solar Cells with Small Driving Force and Its Impact on Voltage Loss

The interplay between free charge carriers, charge transfer (CT) states and singlet excitons (S 1 ) determines the recombination pathway and the resulting open circuit voltage (V OC ) of organic solar cells. By combining a well-aggregated low bandgap polymer with different blend ratios of the fullerenes PCBM and ICBA, the energy of the CT state (E CT ) is varied by 130 meV while leaving the S 1 energy of the polymer (E S 1 ) unaffected. It is found that the polymer exciton dominates the radiative properties of the blend when approaches E CT , while the V OC remains limited by the non-radiative decay of the CT state. It is concluded that an increasing strength of the exciton in the optical spectra of organic solar cells will generally decrease the non-radiative voltage loss because it lowers the radiative V OC limit (V OC,rad ), but not because it is more emissive. The analysis further suggests that electronic coupling between the CT state and the S 1 will not improve the V OC , but rather reduce the V OC,rad . It is anticipated that only at very low CT state absorption combined with a fairly high CT radiative efficiency the solar cell benefit from the radiative properties of the singlet excitons.

14 SOLAR ENERGY↗

Coupled Interfacial Kinetics and Transport Resistances Govern High-Current Behavior in Bipolar Membranes

Bipolar membranes (BPMs) enable electrochemical systems that operate across large pH gradients; however, high-current operation is often limited by voltage losses whose origins remain difficult to resolve in membrane−electrode assemblies. Here, we combine electrochemical impedance spectroscopy with distribution of relaxation times (EIS–DRT) analysis and operando synchrotron X-ray diffraction to examine interfacial polarization, membrane hydration, and transport in commercial and synthesized BPMs. EIS–DRT isolates the BPM-associated interfacial contribution and shows that the commercial BPM exhibits larger water-dissociation-associated overpotentials than the synthesized BPM. Operando hydration mapping shows that both membranes retain water at the bipolar junction during high-current operation, while anode-adjacent hydration gradients are more pronounced in the commercial membrane. These results indicate that high-current voltage losses are not governed by junction water starvation alone but by coupled interfacial polarization and transport resistances.

36 MATERIALS SCIENCE↗

Top-Performing Photovoltaic Cells Compared to the Shockley–Queisser Limit

Top-performing single-junction and two-terminal tandem devices that include at least one polycrystalline cell are compared with each other and their ideal limits. The parameters of open-circuit voltage, short-circuit current, and fill-factor are individually compared to the Shockley–Queisser limit to investigate where different technologies have room to improve. Technologies, such as silicon and cadmium telluride have the most room for improvement in open-circuit voltage currently utilizing 87% and 81% of their maxima, respectively. Detailed diode and fill-factor loss analysis is presented for single-junction devices to give further insight on how they compare and where efficiency is lost. Single-crystal technologies demonstrate a fill-factor closer to the Shockley–Queisser limit than polycrystalline devices. The high diode quality factor of polycrystalline devices is the leading cause of the decreased fill-factor. Similar analysis on tandem cells with at least one thin-film cell shows that although their efficiency exceeds that of the single-junction cells, the fraction of their ideal efficiency is smaller. Here, by comparing parameters to the Shockley–Queisser limit, it becomes clearer where certain technologies have the potential for improvement.

High efficiency↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗