Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultrahigh-Capacity Rocksalt Cathodes Enabled by Cycling-Activated Structural Changes

Mn-redox-based oxides and oxyfluorides are considered the most promising earth-abundant high-energy cathode materials for next-generation lithium-ion batteries. While high capacities are obtained in high-Mn content cathodes such as Li- and Mn-rich layered and spinel-type materials, local structure changes and structural distortions ( often lead to voltage fade, capacity decay, and impedance rise, resulting in unacceptable electrochemical performance upon cycling. In the present study, structural transformations that exploit the high capacity of Mn-rich oxyfluorides while enabling stable cycling, in stark contrast to commonly observed structural changes that result in rapid performance degradation, are reported. Here, it is shown that upon cycling of a cation-disordered rocksalt (DRX) cathode (Li 1.1 Mn 0.8 Ti 0.1 O 1.9 F 0.1 , an ultrahigh capacity of ≈320 mAh g –1 (energy density of ≈900 Wh kg –1 ) can be obtained through dynamic structural rearrangements upon cycling , along with a unique voltage profile evolution and capacity rise. At high voltage, the presence of Mn 4+ and Li + vacancies promotes local cation ordering, leading to the formation of domains of a “δ phase” within the disordered framework. On deep discharge, Mn 4+ reduction, along with Li + insertion transform the structure to a partially ordered DRX phase with a β'-LiFeO 2 -type arrangement. At the nanoscale, domains of the in situ formed phases are randomly oriented, allowing highly reversible structural changes and stable electrochemical cycling. These new insights not only help explain the superior electrochemical performance of high-Mn DRXbut also provide guidance for the future development of Mn-based, high-energy density oxide, and oxyfluoride cathode materials.

25 ENERGY STORAGE↗

Deep learning of experimental electrochemistry for battery cathodes across diverse compositions

Artificial intelligence (AI) has emerged as a tool for discovering and optimizing novel battery materials. However, the adoption of AI in battery cathode representation and discovery is still limited due to the complexity of optimizing multiple performance properties and the scarcity of high-fidelity data. Here, we present a machine learning model (DRXNet) for battery informatics and demonstrate the application in the discovery and optimization of disordered rocksalt (DRX) cathode materials. We have compiled the electrochemistry data of DRX cathodes over the past 5 years, resulting in a dataset of more than 19,000 discharge voltage profiles on diverse chemistries spanning 14 different metal species. Learning from this extensive dataset, our DRXNet model can capture critical features in the cycling curves of DRX cathodes under various conditions. Our approach offers a data-driven solution to facilitate the rapid identification of novel cathode materials, accelerating the development of next-generation batteries for carbon neutralization.

25 ENERGY STORAGE↗

Computational and experimental search for potential polyanionic K-ion cathode materials

Discovering high-energy cathode materials is critical to construct K-ion batteries for practical applications. Owing to the great success of layered oxides in Li- and Na-ion systems, K layered cathodes have also been investigated in recent years. However, the much larger size of K + compared to Li or Na introduces strong K + –K + interaction within the layer, which results in a sloped voltage profile thereby limiting the specific capacity and operating voltage. In contrast, polyanionic materials with a three-dimensional K + arrangement can effectively mitigate K + –K + interaction. In this work, ten K polyanionic compounds with theoretical capacity >100 mA h g –1 are screened from the Inorganic Crystal Structure Database as potential cathode materials for K-ion batteries. Among the ten proposed compounds, K 2 MnP 2 O 7 , K 2 Mn 2 P 2 O 7 F 2 , K 2 Fe 2 P 2 O 7 F 2 , and K 6 V 2 (PO 4 ) 4 with average voltage <4.5 V are synthesized and evaluated electrochemically. While the re-insertion of K into these compounds is not fully reversible, it may be related to the very high migration barrier that we compute for K ions. In addition, we show the successful synthesis of a series of K 3 V 3–x Cr x (PO 4 ) 4 (x = 0, 1, 2, 3) compounds. Among these, K 3 V 2 Cr(PO 4 ) 4 exhibits the largest reversible capacity, as revealed by the in situ investigation. Lastly, we find that the redox couples in many of these compounds sit at remarkably high potential, even higher than in equivalent Li compounds, which brings both opportunities and challenges in the future research of K polyanion cathodes.

25 ENERGY STORAGE↗

Closed cycle MHD power generation experiments in the NASA Lewis Facility

Many modifications were made in the MHD facility. These include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation of all the high temperature components from each other and from ground, and experimentation with various cesium seed vaporization and injection techniques. With the exception of the cesium system which needs further improvement the above modifications were quite successful and resulted in improvements in generator performance. The facility was run for a total of 400 hours in the past year, with 70 hours of this operation at temperatures of 2000 K or more with hot generator walls. With the exception of replacing one cracked brick in the MHD channel no repairs were required in the high temperature loop components for the duration of these tests. Uniform Faraday and Hall voltage profiles were obtained and the Faraday open circuit voltage varied from 90 to 100 percent of the ideal uBh. The magnitudes of the measured parameters are: Faraday open circuit voltage approximately 70 V, total Faraday current approximately 20 A, Hall voltage approximately 250 V, power output approximately 300 W, and power density .036 W/cu cm.

Sovie, R. J.↗

Closed cycle MHD power generation experiments in the NASA Lewis facility

Discussion of the performance improvements achieved through some modifications made in the closed cycle MHD facility. These modifications include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation, and experimentation with various cesium seed vaporization and injection techniques. Uniform Faraday and Hall voltage profiles were obtained, and the Faraday open circuit voltage varied from 90 to 100% of the ideal uBh.

Sovie, R. J.↗

Phase-Controlled Magnetic Mirror for Wavefront Correction

Typically, light interacts with matter via the electric field and interaction with weakly bound electrons. In a magnetic mirror, a patterned nanowire is fabricated over a metallic layer with a dielectric layer in between. Oscillation of the electrons in the nanowires in response to the magnetic field of incident photons causes a re-emission of photons and operation as a "magnetic mirror." By controlling the index of refraction in the dielectric layer using a local applied voltage, the phase of the emitted radiation can be controlled. This allows electrical modification of the reflected wavefront, resulting in a deformable mirror that can be used for wavefront control. Certain applications require wavefront quality in the few-nanometer regime, which is a major challenge for optical fabrication and alignment of mirrors or lenses. The use of a deformable magnetic mirror allows for a device with no moving parts that can modify the phase of incident light over many spatial scales, potentially with higher resolution than current approaches. Current deformable mirrors modify the incident wavefront by using nano-actuation of a substrate to physically bend the mirror to a desired shape. The purpose of the innovation is to modify the incident wavefront for the purpose of correction of fabrication and alignment-induced wavefront errors at the system level. The advanced degree of precision required for some applications such as gravity wave detection (LISA - Laser Interferometer Space Antenna) or planet finding (FKSI - Fourier-Kelvin Stellar Interferometer) requires wavefront control at the limits of the current state of the art. All the steps required to fabricate a magnetic mirror have been demonstrated. The modification is to apply a bias voltage to the dielectric layer so as to change the index of refraction and modify the phase of the reflected radiation. Light is reflected off the device and collected by a phase-sensing interferometer. The interferometer determines the initial wavefront of the device and fore optics. A wavefront correction is calculated, and voltage profile for each nanowire strip is determined. The voltage is applied, modifying the local index of refraction of the dielectric under the nanowire strip. This modifies the phase of the reflected light to allow wavefront correction.

Hagopian, John↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

Dielectric Barrier Discharge Plasma Actuator for Flow Control

This report is Part II of the final report of NASA Cooperative Agreement contract no. NNX07AC02A. It includes a Ph.D. dissertation. The period of performance was January 1, 2007 to December 31, 2010. Part I of the final report is the overview published as NASA/CR-2012- 217654. Asymmetric dielectric barrier discharge (DBD) plasma actuators driven by nanosecond pulses superimposed on dc bias voltage are studied experimentally. This produces non-self-sustained discharge: the plasma is generated by repetitive short pulses, and the pushing of the gas occurs primarily due to the bias voltage. The parameters of ionizing pulses and the driving bias voltage can be varied independently, which adds flexibility to control and optimization of the actuators performance. The approach consisted of three elements coupled together: the Schlieren technique, burst mode of plasma actuator operation, and 2-D numerical fluid modeling. During the experiments, it was found that DBD performance is severely limited by surface charge accumulation on the dielectric. Several ways to mitigate the surface charge were found: using a reversing DC bias potential, three-electrode configuration, slightly conductive dielectrics, and semi conductive coatings. Force balance measurements proved the effectiveness of the suggested configurations and advantages of the new voltage profile (pulses+bias) over the traditional sinusoidal one at relatively low voltages. In view of practical applications certain questions have been also addressed, such as electrodynamic effects which accompany scaling of the actuators to real size models, and environmental effects of ozone production by the plasma actuators.

Opaits, Dmitry, F.↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling phase transformations in Mn-rich disordered rocksalt cathodes with machine-learning interatomic potentials

Mn-rich disordered rocksalt (DRX) cathode materials exhibit a phase transformation from a disordered to a partially disordered spinel-like structure (δ-phase) during electrochemical cycling. Here, in this computational study, we use charge-informed molecular dynamics with a fine-tuned CHGNet foundation potential to investigate the phase transformation in LixMn 0.8 Ti 0.1 O 1.9 F 0.1 . Our results indicate that transition metal migration occurs and reorders to form the spinel-like ordering in an FCC anion framework. The transformed structure contains a higher concentration of nontransition metal (0-TM) face-sharing channels, which are known to improve Li transport kinetics. Analysis of the Mn valence distribution suggests that the appearance of tetrahedral Mn 2+ is a consequence of spinel-like ordering, rather than the trigger for cation migration as previously suggested. Calculated equilibrium intercalation voltage profiles demonstrate that the δ-phase, unlike the ordered spinel, exhibits solid-solution signatures at low voltage. A higher Li capacity is obtained than in the DRX phase. This study provides atomic insights into solid-state phase transformation and its relation to experimental electrochemistry, highlighting the potential of machine-learning interatomic potentials for understanding complex oxide materials.

Zhong, Peichen [University of California, Berkeley↗

Relationship between Sodium Content and Copper Activity for High Voltage Stability in O3-Type Layered Oxide Cathodes

Layered oxides with an O3 framework have attracted attention as cathode materials for sodium-ion batteries due to their high discharge capacity. Yet they are hampered for commercialization by poor cyclability due to structural instability during the sodium (de)intercalation process. The introduction of Cu in small fractions to the transition metal layers has been empirically observed to improve reversible specific capacity and cycling stability. Understanding the redox activity of Cu in O3-type Na x TMO 2 materials is crucial, as it could directly influence the charge compensation mechanism, voltage profile, and structural stability. However, the precise role of Cu in O3-type sodium cathodes under high-voltage cycling conditions (>4.1 V) remains insufficiently understood. To close this gap of knowledge, we studied the effect of Cu in two representative layered oxides with the same O3 stacking but different sodium stoichiometry, Na 0.9 Mn 1/2 Fe 1/3 Cu 1/6 O 2 and NaMn 1/2 Fe 1/3 Cu 1/6 O 2 . X-ray spectroscopy reveals that in Na 0.9 Mn 1/2 Fe 1/3 Cu 1/6 O 2 , Cu exhibits dual redox activity, Cu + /Cu 2+ in the pristine state and Cu 2+ /Cu 3+ upon charging in the sodium-deficient material, whereas only the Cu + /Cu 2+ redox couple is observed in the fully stoichiometric layered oxide. Furthermore, the results indicate that even a slight deficiency in sodium can significantly impact the electrochemical performance and material stability and alter the elemental redox activity of Cu.

Batteries↗

Solvation-property relationship of lithium-sulphur battery electrolytes

Abstract The Li-S battery is a promising next-generation battery chemistry that offers high energy density and low cost. The Li-S battery has a unique chemistry with intermediate sulphur species readily solvated in electrolytes, and understanding their implications is important from both practical and fundamental perspectives. In this study, we utilise the solvation free energy of electrolytes as a metric to formulate solvation-property relationships in various electrolytes and investigate their impact on the solvated lithium polysulphides. We find that solvation free energy influences Li-S battery voltage profile, lithium polysulphide solubility, Li-S battery cyclability and the Li metal anode; weaker solvation leads to lower 1 st plateau voltage, higher 2 nd plateau voltage, lower lithium polysulphide solubility, and superior cyclability of Li-S full cells and Li metal anodes. We believe that relationships delineated in this study can guide the design of high-performance electrolytes for Li-S batteries.

25 ENERGY STORAGE↗

AI4MG-networked-microgrid-models

SF-26-123 24-hour scaled power-flow analysis of a modified IEEE 123-bus distribution feeder using OpenDSS. The simulation runs 24 snapshot power-flow cases (one per hour) with independent hourly scaling profiles for base loads, added loads, generators, and battery storage, and writes per-hour CSV/Excel reports plus a 24-panel voltage-profile plot.

Kumar, Kiran [Argonne National Laboratory (ANL), A↗

Li–Mn–O Li-rich cation disordered rock-salt cathode materials do not undergo reversible oxygen redox during cycling

An in-depth study of “Li 4 Mn 2 O 5 ”, a nanocomposite of Li 2 O and Li 4-x Mn 2 O 5 with a disordered rock salt structure (LMO), was conducted to determine the origins of the observed anomalously high charge and discharge capacity in lithium cells, which can exceed 350 mA h g -1 . Using soft and hard X-ray absorption spectroscopy (XAS), mapping of resonant inelastic X-ray scattering (mRIXS), and X-ray Raman spectroscopy (XRS), it was determined that electrochemical decomposition of Li 2 O upon charge and reduction of Mn to below 3+ during discharge is responsible for the capacities that are observed, with no evidence of contributions from reversible oxygen redox. Here, the over-reduction is exacerbated when charging limits of 4.5–4.8 V are used due to side reactions between electrolytic solution and the highly oxidized active material. These side reactions result in dissolution of Mn at room temperature and release of oxygen and other gases during initial cycles, which, in turn, cause rapid capacity fading. This is accompanied by evolution of the voltage profile upon cycling towards one that resembles that of manganese oxide spinels. The cycling behavior can be improved somewhat by reducing the upper voltage limit, although this results in a diminishment of the discharge capacities below 200 mA h g -1 . By adding various amounts of spinel LiMn 2 O 4 during synthesis, it was possible to produce LMOs with rock salt structures having significantly improved cycling behavior but still having capacities in excess of 250 mA h g -1 . An optimized modified material also exhibits better rate capability and much less gas evolution during initial cycles than the unmodified LMO. Interestingly, as-made modified materials generally exhibited lower than expected average Mn oxidation states attributable to oxygen loss during the synthesis process, as well as higher capacities than expected based on their manganese contents. The oxygen loss during processing may reduce the activity of the remaining oxygen and account for the lower reactivity of the spinel-modified material.

25 ENERGY STORAGE↗