Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability

Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework for Robust Long-Term Voltage Stability of Distribution Systems

Power injection uncertainties in distribution power grids, which are mostly induced by aggressive introduction of intermittent renewable sources, may drive the system away from normal operating regimes and potentially lead to the loss of long-term voltage stability (LTVS). Naturally, there is an ever increasing need for a tool for assessing the LTVS of a distribution system. This paper presents a fast and reliable tool for constructing inner approximations of LTVS regions in multidimensional injection space such that every point in our constructed region is guaranteed to be solvable. Numerical simulations demonstrate that our approach outperforms all existing inner approximation methods in most cases. Furthermore, the constructed regions are shown to cover substantial fractions of the true voltage stability region. In conclusion, the paper will later discuss a number of important applications of the proposed technique, including fast screening for viable injection changes, constructing an effective solvability index and rigorously certified loadability limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Thévenin equivalent sensitivity equations for reliable voltage stability assessment

In this paper, sensitivity equations for the Thévenin equivalent parameters, voltage and reactance, are derived using the duality between the Thévenin parameters from two consecutive PMU measurements. Using the sensitivity equation for the Thévenin reactance, a robust adaptive X-Th algorithm is developed aiming to extend a well-known adaptive E-Th approach by being able to accurately estimate the parameters for a wider range of loading conditions. In the performed case studies the resulting accuracy is evaluated when estimating the Thévenin parameters for large disturbances, for two sides with respect to a boundary bus, accommodating sensitivity to topology changes and nonlinearities in power systems. In conclusion, the results can be used for accurate voltage stability assessment using the Thévenin parameters.

42 ENGINEERING↗

On the Configuration of the US Western Interconnection Voltage Stability Boundary

Abstract—Stability limits are considered in power system planning and operations to estimate the available stability margins and, if possible, to maximize the utilization of transmission facilities. These important tasks are influenced by configuration of the stability boundary. The paper introduces a new fast approach to explore the voltage stability boundary of a large system and reveal its detailed multidimensional structure. The 17939-bus U.S. Western Interconnection planning model was used to illustrate the method. Significant peculiarities of the boundary’s configuration were identified, including its nonconvexity, discontinuity, branching and internal singularities (“holes”) that were not known before and could not been found by traditional methods. Experiments using WECC system are performed to evaluate the computation time using different methods. Our results show that the proposed methods are very promising in reducing calculation time and complexity

Makarov, Yuri V.↗

Interpolation Approximation of Voltage Stability Constrained OPF (VSCOPF) for Reactive Power Planning

Reactive power planning (RPP), or Var planning, is to identify the optimal size and location of reactive power sources. In this paper, first, the previous work using least square method to simplify the voltage stability constrained OPF (VSCOPF) model for RPP is presented. Then, this paper presents a new model simplification solution using interpolation. The interpolation approach can be easily applied to a piecewise formulation while preserving the continuity at boundary points, which cannot be easily achieved by previous works like the least square method. The proposed interpolation approach is numerically tested and compared with the least square approach. It is concluded that interpolation is an improved model simplification approach for RPP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive Control of Distributed Energy Resources for Distribution Grid Voltage Stability

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. Here we provide a derivation of the adaptive control approach and validate the algorithm in experiments on the IEEE 37 and 8500 node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High voltage stability performance of a gamma ray detection device

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship between Sodium Content and Copper Activity for High Voltage Stability in O3-Type Layered Oxide Cathodes

Layered oxides with an O3 framework have attracted attention as cathode materials for sodium-ion batteries due to their high discharge capacity. Yet they are hampered for commercialization by poor cyclability due to structural instability during the sodium (de)intercalation process. The introduction of Cu in small fractions to the transition metal layers has been empirically observed to improve reversible specific capacity and cycling stability. Understanding the redox activity of Cu in O3-type Na x TMO 2 materials is crucial, as it could directly influence the charge compensation mechanism, voltage profile, and structural stability. However, the precise role of Cu in O3-type sodium cathodes under high-voltage cycling conditions (>4.1 V) remains insufficiently understood. To close this gap of knowledge, we studied the effect of Cu in two representative layered oxides with the same O3 stacking but different sodium stoichiometry, Na 0.9 Mn 1/2 Fe 1/3 Cu 1/6 O 2 and NaMn 1/2 Fe 1/3 Cu 1/6 O 2 . X-ray spectroscopy reveals that in Na 0.9 Mn 1/2 Fe 1/3 Cu 1/6 O 2 , Cu exhibits dual redox activity, Cu + /Cu 2+ in the pristine state and Cu 2+ /Cu 3+ upon charging in the sodium-deficient material, whereas only the Cu + /Cu 2+ redox couple is observed in the fully stoichiometric layered oxide. Furthermore, the results indicate that even a slight deficiency in sodium can significantly impact the electrochemical performance and material stability and alter the elemental redox activity of Cu.

Batteries↗

High voltage stability of LiCoO2 particles with a nano-scale Lipon coating

For high-voltage cycling of rechargeable Li batteries, a nano-scale amorphous Li-ion conductor, lithium phosphorus oxynitride (Lipon), has been coated on surfaces of LiCoO{sub 2} particles by combining a RF-magnetron sputtering technique and mechanical agitation of LiCoO{sub 2} powders. LiCoO{sub 2} particles coated with 0.36 wt% ({approx}1 nm thick) of the amorphous Lipon, retain 90% of their original capacity compared to non-coated cathode materials that retain only 65% of their original capacity after more than 40 cycles in the 3.0-4.4 V range with a standard carbonate electrolyte. The reason for the better high-voltage cycling behavior is attributed to reduction in the side reactions that cause increase of the cell resistance during cycling. Further, Lipon coated particles are not damaged, whereas uncoated particles are badly cracked after cycling. Extending the charge of Lipon-coated LiCoO{sub 2} to higher voltage enhances the specific capacity, but more importantly the Lipon-coated material is also more stable and tolerant of high voltage excursions. A drawback of Lipon coating, particularly as thicker films are applied to cathode powders, is the increased electronic resistance that reduces the power performance.

25 ENERGY STORAGE↗

Fluorinated Electrolytes for 5-V Li-Ion Chemistry: Probing Voltage Stability of Electrolytes with Electrochemical Floating Test

A series of electrolyte formulations containing fluorinated cyclic carbonates and fluorinated linear carbonates with LiPF6 has been evaluated as electrolyte solvents for high-voltage Li-ion batteries. The anodic stability of the new electrolytes on fully charged spinel LiNi0.5Mn1.5O4 (LNMO) cathode was examined by electrochemical floating tests. The effects of fluorine substitution on the cyclic and linear carbonate, ratio of cyclic vs. linear carbonate, and LiPF6 concentration on the electrolyte oxidation stability were investigated. Based on this study, the floating test proved to be an effective tool for identification of stable electrolyte materials.

5-V LiNi0.5Mn1.5O4 cathode↗

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY↗

Aggregate data‐driven dynamic modeling of active distribution networks with DERs for voltage stability studies

Abstract Electric distribution networks increasingly host distributed energy resources based on power electronic converter (PEC) toward active distribution networks (ADN). Despite advances in computational capabilities, electromagnetic transient models are limited in scalability because of their reliance on exact data about the distribution system and each of its components. Similarly, the use of the DER_A model, which is intended to examine the combined dynamic behavior of many DERs, is limited by the difficulty in parameterization. There is a need for improved dynamic models of DERs for use in large power system simulations for stability analysis. This paper proposes an aggregate model‐free, data‐driven approach for deriving a dynamic partitioned model (DPM) of ADNs. Detailed residential distribution feeders were first developed, including PEC‐based DERs and composite load models (CMLDs), from which the aggregated DPM was derived. The performance was evaluated through various case studies and validated against the detailed ADN model and state‐of‐the‐art DER_A model with CMLD. The data‐driven DPM achieved a of over 90%, accurately representing the aggregated dynamic behavior of ADNs. Furthermore, the DPM significantly accelerated the simulation process with a computational speedup of 68 times compared to the detailed ADN and a 3.5 times speedup compared to the DER_A CMLD model.

42 ENGINEERING↗