Search NASA⌕ Search

SEARCH · Search NASA

Results for “vuv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reconstructing the Solar VUV Irradiance over the Past 60 Years

The Flare Irradiance Spectral Model (FISM) is an empirical model of the solar irradiance spectrum from 0.1 to 190 nm at I nm spectral resolution and on a 1-minute time cadence. The goal of FISM is to provide accurate solar spectral irradiances over the vacuum ultraviolet (VUV: 0-200 nm) range as input for ionospheric and thermospheric models, as well as climate studies over 60 years. A brief overview of the FISM model will be given, and also discussed is how the Solar Dynamics Observatory (SDO) EUV Variability Experiment (EVE) will contribute to improving FISM and its accuracies. Results will also be shown quantifying the VUV contributions to the total flare energy budget, and more importantly discuss the increased errors associated by not including flares in the solar energy input to the Earth's system. Concluding the talk will be a discussion of the proxies, and their associated uncertainties, used for solar spectral reconstructions prior to 1947 going back hundreds of years.

Chamberlin, Phillip↗

Laboratory Spectroscopy of Planetary Ices in the VUV and THz Spectral Regions

I will describe efforts to study the spectroscopy of condenser) films at low temperature (10-150 K) in both the far-infrared/THz (30-3000 microns) and vacuum-ultraviolet (VUV, 100-200 nm.) ranges of the electromagnetic spectrum. In each of these wavelength ranges, there is a general lack of laboratory data for ices relevant to astrophysical environments such as the outer Solar System. These studies are focused on mixtures of candidate species applicable to planets and satellites in the outer solar system, such as those dominated by H2O or N2 with other important species such as CO2, CH4, and NH3. We will discuss our results in relation to analyses of VUV data sets from the UVIS instrument on Cassini, far-infrared data from missions such as Herschel and SOFIA, as well as sub-mm observatories such as ALMA.

Gerakines, P.↗

Spectrum of Al VII in the vuv

The spectrum of Al VII is re-examined in the vuv. A laser-produced plasma is used as a light source. Twenty-four newly classified lines are reported. No new energy levels have been determined.

Valero, F. P. J.↗

Tunable VUV photofragment monochromator

A versatile tunable VUV photofragment monochromator is described. The instrument uses a unique flashlamp and a single slit monochromator to produce the photofragments. A tunable dye laser is used to detect these fragments via laser induced fluorescence. The results of preliminary design parameter measurements are presented along with the first photofragment spectra obtained with this instrument. It is shown that the SNR is adequate to assign single quantum state photofragment distributions.

Miller, G. E.↗

Need for high resolution in VUV Rydberg state spectroscopy

The paper emphasizes the necessity of high energy resolution (resolving powers greater than 100,000) in VUV spectroscopic determinations of atomic and molecular Rydberg electronic structures. Attention is given to spectral observations of Rydberg levels in Ge I near the 4p 2P(0)1/2 limit, in Sr I near the 4d 2D3/2 limit, and in diatomic hydrogen halides (especially H I) below the X2Pi3/2 limit.

Ginter, M. L.↗

Electron-photon coincidence technique for the absolute calibration of VUV detectors

A method is described whereby VUV photon detectors can be accurately calibrated. This method is illustrated by taking the 58.4-nm transition of He as an example. The technique consists of crossing a monoenergetic electron beam with a beam of He atoms. When inelastically scattered electrons which have excited the 2 1P state are detected in coincidence with the 58.4-nm photons emitted in the decay of the excited state, the interaction volume formed by the crossed beams constitutes a standard source of photons. By comparing the number of detected coincidences with the predicted number the calibration can be made. A total detector efficiency of 0.024 + or - 0.003 is obtained for a Galileo 4830 channeltron.

Mcadams, R.↗

Interstellar O2. II - VUV oscillator strengths of Schumann-Runge lines and prospects for Space Telescope observations

Interstellar molecular oxygen should be detectable in interstellar clouds through observation of its absorption lines in the spectra of background stars. This paper describes and presents the results of measurements of oscillator strengths for some lines in the vacuum ultraviolet (VUV) spectrum of O2. Lines of the (13, 0) through (16, 0) bands of the B 3Sigma(-)u - X 3Sigma(-)g, Schumann-Runge system between 1760 A and 1790 A will be the most suitable for searches for absorption by interstellar O2 with the High Resolution Spectrograph on Space Telescope. The strongest lines in these bands have oscillator strengths of about 3 x 10 to the -5th.

Smith, P. L.↗

Quantitative VUV spectroscopy of Cl2

The photoabsorption and fluorescence cross sections of Cl2 were measured in the 105-145 nm region using synchrotron radiation as a light source. The oscillator strengths for the major absorption bands were calculated from the measured absorption cross sections. The measured oscillator strengths for the 2 3Pi u and 2 1Pi u - X 1Sigma(+)g transitions agree quite well with the theoretical values. The absorption spectrum was analyzed in accord with the excited electronic states calculated by Peyerimhoff and Buenker (1981). The Rydberg series converging to the first and second ionization potentials were classified. The vibrational levels of the 2 1Sigma(+)u ionic state were determined up to v prime = 15 from the fluorescence excitation spectrum. It was observed that a band with peak at 108.3 nm produces VUV fluorescence, but it produces UV fluorescence only by a collisional excitation process.

Lee, L. C.↗

Ion-assisted deposition of lanthanide trifluorides for VUV applications

The lanthanide trifluorides show promise as vacuum ultraviolet (VUV) coating materials. The optical properties of single-layer coatings vary with deposition temperature, and with ion-beam energy and current density. The optical constants, stoichiometry, durability, moisture adsorption, and crystallinity are studied for trifluoride films made under a variety of deposition conditions.

Lingg, L. J.↗

UV and VUV spectroscopy and photochemistry of small molecules in a supersonic jet

UV and VUV absorption and emission spectroscopy is used to probe jet cooled molecules, free radicals, and clusters in the gas phase. Due to efficient cooling inhomogeneous effects on spectral line widths are eliminated. Therefore from these spectra, both structural and dynamical information is obtained. The photoproducts of these reactions are probed by resonance enhanced multiphoton ionization.

Ruehl, E.↗

Line Profile Measurements of Atomic Oxygen at 1300 A with a VUV Raman Shifter

We are currently developing an atomic oxygen diagnostic to study the degree of oxygen dissociation in ground-based facilities. The absorption of the (sub 3)P - (sup 3)S(sup 0) resonance triplet in the vacuum ultraviolet is a direct measure of the ground state number density of atomic oxygen. Although the integrated line strength is well known for these transitions, the line profile is not. We report the results of a series of experiments in which the line profile is measured in shock-heated oxygen. An ArF excimer laser and a hydrogen Raman shifter generate tunable VUV radiation at the resonance wavelength. The test gas is dissociated oxygen, generated in the Electric Arc Shock Tube (EAST) Facility at NASA-Ames Research Center. By measuring the absorption of known concentrations of atomic oxygen, we are able to study the absorption line profile. The results will serve as a calibration to apply this diagnostic in other flowfields.

Sharma, Surendra P.↗

Deuterium Enrichment of PAHs by VUV Irradiation of Interstellar Ices

Laboratory results demonstrate that polycyclic aromatic hydrocarbons (PAHs) rapidly exchange their hydrogen atoms with those of nearby molecules when they are frozen into low-temperature ices and exposed to vacuum ultraviolet radiation. As a result, PAHs quickly become deuterium-enriched when VUV irradiated in D-containing ices. This mechanism has important consequences for several astrophysical issues owing to the ubiquitous nature of PAHs in the interstellar medium. For example, this process may explain the deuterium enrichments found in PAHs in meteorites and interplanetary dust particles. These results also provide general predictions about the molecular siting of the deuterium on aromatic materials in meteorites if this process produced a significant fraction of their D-enrichment.

Bernstein, Max P.↗

EUV-VUV Photolysis of Molecular Ice Systems of Astronomical Interest

We wish to report laboratory simulation results obtained from extreme ultraviolet (EUV) and vacuum ultraviolet (VUV) photolysis of molecular ices relevant to the cometary-type ices and icy satellites of planetary systems. Specifically, we identify the type of molecules that form in the ices and/or those that come off the ice surfaces, quantify their production yields and destruction yields, understand their production mechanisms, and ascertain their significance in astronomical environments.

Wu, C. Y. Robert↗

Reconstructing the Solar VUV Irradiance Over the Past 60 Years

Actual observations of the solar spectral irradiance are extremely limited on climate time scales; therefore, various empirical models use solar proxies to reconstruct the actual output of the Sun over long time scales. The Flare Irradiance Spectral Model (FISM) is an empirical model of the solar irradiance spectrum from 0.1 to 190 nm at 1 nm spectral resolution and on a I-minute time cadence. The goal of FISM is to provide accurate solar spectral irradiances over the vacuum ultraviolet (VUV: 0-200 nm) range as input for ionospheric and thermospheric. A brief overview of the proxies used in the FISM model will be given, and also discussed is how the Solar Dynamics Observatory (SDO) EUV Variability Experiment (EVE) will contribute to improving FISM estimates and its accuracies. Also presented will be a discussion of other solar irradiance proxies and measurements, and their associated uncertainties, used for solar spectral reconstructions.

Chamberlin, Phillip C.↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Champey, Patrick↗