Search NASASearch

SEARCH · Search NASA

Results for “wall insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)

Dynamics and Formation of Antiferromagnetic Textures in MnBi 2 Te 4 Single Crystal

We report coherent X-ray imaging of antiferromagnetic (AFM) domains and domain walls in MnBi 2 Te 4 , an intrinsic AFM topological insulator. This technique enables direct visualization of domain morphology without reconstruction algorithms, allowing us to resolve antiphase domain walls as distinct dark lines arising from the A-type AFM structure. The wall width is determined to be 550(30) nm, in good agreement with earlier magnetic force microscopy results. The temperature dependence of the AFM order parameter extracted from our images closely follows previous neutron scattering data. Remarkably, however, we find a pronounced hysteresis in the evolution of domains and domain walls: upon cooling, dynamic reorganizations occur within a narrow ∼1 K interval below 𝑇 𝑁 , whereas upon warming, the domain configuration remains largely unchanged until AFM order disappears. These findings reveal a complex energy landscape in MnBi 2 Te 4 , governed by the interplay of exchange, anisotropy, and domain-wall energies, and underscore the critical role of AFM domain-wall dynamics in shaping its physical properties. These sharply defined and hysteretically evolving walls may provide a controllable AFM texture in MnBi 2 Te 4 , hinting at potential use in low-power spintronic devices based on domain-wall dynamics.

36 MATERIALS SCIENCE

Wall modes and the transition to bulk convection in rotating Rayleigh-Bénard convection

We investigate states of rapidly rotating Rayleigh-Bénard convection in a cylindrical cell over a range of Rayleigh numbers 3 × 10 5 ≤ Ra ≤ 5 × 10 9 and Ekman numbers 10 − 6 ≤ Ek ≤ 10 − 4 for Prandtl number Pr = 0.8 and aspect ratios 1 / 5 ≤ Γ ≤ 5 using direct numerical simulations. We characterize, for perfectly insulating sidewall boundary conditions, the first transition to convection via wall mode instability and the nonlinear growth and instability of the resulting wall mode states, including a secondary transition to time dependence. We show how the radial structure of the vertical velocity u z and the temperature T is captured well by the linear eigenfunctions of the wall mode instability where the radial width of u z is δ u z ∼ Ek 1 / 3 r / H whereas δ T ∼ e − k r ( k is the wave number of a laterally infinite wall mode state). The disparity in spatial scales for Ek = 10 − 6 means that the heat transport is dominated by the radial structure of u z since T varies slowly over the radial scale δ u z . We further describe how the transition to a state of bulk convection is influenced by the presence of the wall mode states. We use temporal and spatial scales as measures of the local state of convection and the Nusselt number Nu as representative of global transport. Our results elucidate the evolution of the wall state of rotating convection and confirm that wall modes are strongly linked with the boundary zonal flow being the robust remnant of nonlinear wall mode states. We also show how the heat transport ( Nu ) contributions of wall modes and bulk modes are related and discuss approaches to disentangling their relative contributions. Published by the American Physical Society 2024

58 GEOSCIENCES

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Pressure equilibrated thermal insulation gap

A thermal structure for management of thermal energy, the thermal structure including: a first wall structure defining a first cavity; a second wall structure defining a second cavity, the second cavity in fluid communication with the first cavity; and a barrier cavity defined at least in-part by the first wall structure and the second wall structure, wherein the barrier cavity is disposed between the first cavity and the second cavity and includes a pressurized barrier fluid therein or is configured to receive the pressurized barrier fluid during operation of the thermal structure.

Erno, Daniel Jason

Concept of Dynamic Heat Insulation for Rotating Detonation Engines

This work introduces a new class of materials concept to dynamically reduce instantaneous heat fluxes in Rotating Detonation Engine (RDE) combustor chamber walls. The high-frequency and high-amplitude surface heat fluxes observed in RDEs arise from large instantaneous temperature differences between the detonation shockwave and chamber wall surface. These temperature gradients drive substantial energy loss and reduce the chamber gas pressure, ultimately limiting the cycle’s thermodynamic efficiency. This work introduces a concept for dynamically insulating the combustion chamber surfaces using surface layers or coatings with low thermal time scale. With such coatings, the surface temperature may follow the fluctuations of the cyclic detonation wave temperature, thus reducing the instantaneous heat flux therefore cycle-mean heat flux. To analyze these cyclic thermal phenomena, a one-dimensional analytical conduction solver was utilized with the capability to handle multilayered structures. Parametric modeling was performed using transient heat flux boundary conditions representative of a hydrogen–air RDE across a broad range of coating thermal properties and engine conditions. The coating effectiveness scaled with the product of thermal time constant and detonation wave frequency and the results were non-dimensionalized to guide future materials development. This strategy may offer benefits in increasing material survivability, reducing cooling requirements, and enhancing pressure gain.

heat transfer

Conformable, Composite Tank for Liquid Hydrogen Storage in Heavy-duty Ground Transportation

Raytheon Technologies Research Center (RTRC), with its partners, Argonne National Labs and University of Dayton Research Institute proposed to design and manufacture a conformable composite tank prototype to store liquid Hydrogen (LH2) for heavy-duty truck applications. A dual-wall tank concept was proposed where an outer shell covers and protects an inner pressure vessel that stores liquid hydrogen. The inner pressure vessel is liner-less and designed with a conformable concept, derived from prior RTRC ARPA-E program where multiple vessels are coalesced into one, maximizing space utilization and reducing surface area for heat leak. The gap between the dual wall is evacuated of air pressure, and filled with multi-layer insulation to minimize radiative heat transfer. Fiber reinforced composites were proposed for light-weighting and conformable shape manufacture. To minimize LH2 leakage, carbon nanotubes-infused composites were proposed, in addition to use of thin plies. The project was divided into two 18-month budget periods (BP), BP1 and BP2, separated by a Go/No-Go gate review. The high-level goal for BP1 was to demonstrate the feasibility of the overall approach, the tank design, material selection, and manufacturing methodology, build and test a prototype tank; and the goal for BP2 was to design and manufacture a conformal tank per DOE requirements (minimum 20 kg of LH2) and perform a successful test of the tank. The program was terminated about two-thirds of the way through BP1. The outcome of this program would have permitted long-haul trucks and construction vehicles to use liquid Hydrogen, reducing the emission of green-house gases. This technology is applicable to other transportation sectors as well.

08 HYDROGEN

Building Science Advisor (BSA): A Tool to Assist in the Design and Education of Durable Envelopes

The moisture durability of a building envelope component can be difficult to predict. It depends on the materials used, the location in the assembly, the macro- and microclimate of the building, the air tightness of the interior environment and construction quality. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies are designed and built to retain moisture durability. Furthermore, as new products are introduced to the market, builders are increasingly uncertain about the long-term durability of their building envelope designs. As building envelopes get tighter and better insulated, moisture management is key to a durable and high-performing wall assembly.

Desjarlais, Andre

Activation of Insulation in Low Power Nuclear Experiments

Nuclear experiments aim to test new designs, procedures, and materials. Similar to conventional power reactors, potential sources of worker exposure to radiation is a primary concern. One such concern is the insulation materials that are used in or near the reactor, which can often create dust when being handled. If this material receives a substantial neutron dose, then it can become activated, which can pose a health risk if inhaled or ingested. This analysis looked at the activation of, and conservative dose estimates from, industrial grade insulations that may be used in a reactor experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Optimization of wall assembly for DOE Efficient New Homes Program in HUD’s Climate Zones 2 and 3

Manufactured homes provide affordable housing for over 20 million Americans. The U.S. Department of Energy’s Efficient New Homes (ENH) program has introduced new energy certification requirements that manufacturers can optionally target to ensure outstanding levels of energy savings, comfort, health, and durability. In collaboration with Clayton Homes (under User Agreement (NN-23-1469)), Oak Ridge National Laboratory evaluated multiple wall assembly options to meet ENH requirements in HUD Climate Zones 2 and 3, with a target maximum cost premium of 5%. After analyzing thermal performance, cost, and manufacturability, insulated structural sheathing was identified as the most practical and effective solution. A full-scale manufactured home prototype demonstrated that this approach meets energy performance goals with minimal disruption to existing manufacturing processes and a cost premium of less than 10% with a path to further lower costs, offering a promising path forward for more efficient manufactured housing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI