At least 37 records · Page 2

Hygrothermal Performance of Bio-Based Materials in Residential Building Wall Envelope Systems

In the United States, building envelope systems contribute approximately 28% of building energy consumption, with walls being a primary factor. As the construction industry explores new approaches to lower the energy intensity needed to manufacture materials and, in turn, reduce energy consumption, bio-based materials are gaining attention as a promising alternative. While prior studies have demonstrated that bio-based materials can decrease material energy intensity, their long-term hygrothermal behavior within a whole residential wall system is not yet fully understood. This study aims to evaluate the potential of replacing Oriented Strand Board (OSB) and drywall in residential wall systems with bio-based alternatives. The research focuses on two bio-based materials, assessing their hygrothermal performance under Chicago climate condition (Climate Zone 5). To achieve that, a series of laboratory experiments were conducted to measure key properties of the bio-based materials such as thickness, dimensions, density, thermal conductivity (as a function of temperature and humidity), moisture-dependent permeance and water vapor permeability (WVP), and sorption isotherms. These properties were then used in WUFI® simulations to predict the moisture durability of a standard residential wall system in Climate Zone 5. Results show that substituting OSB and drywall with bio-based materials can achieve acceptable moisture durability, effectively mitigating risks of mold growth and structural damage over time.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett was selected to be adapted for the Ames 12-ft Wind Tunnel Wall Interference Assessment/Correction (WIAC) System in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered, and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method - Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included in the supplement No. 1 to the basic Grant. On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference; and support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated.

Lo, Ching F.↗

Vulnerability of Space Station Freedom Modules: A Study of the Effects of Module Perforation on Crew and Equipment: Analytical Modeling of Internal Debris Cloud Effects - Volume 2

In this part of the report, a first-principles based model is developed to predict the overpressure and temperature effects of a perforating orbital debris particle impact within a pressurized habitable module. While the effects of a perforating debris particles on crew and equipment can be severe, only a limited number of empirical studies focusing on space vehicles have been performed to date. Traditionally, crew loss or incapacitation due to a perforating impact has primarily been of interest to military organizations and as such have focused on military vehicles and systems. The module wall considered in this study is initially assumed to be a standard Whippletype dual-wall system in which the outer wall protects the module and its inhabitants by disrupting impacting particles. The model is developed in a way such that it sequentially characterizes the phenomena comprising the impact event, including the initial impact, the creation and motion of a debris cloud within the dual-wall system, the impact of the debris cloud on the inner wall, the creation and motion of the debris cloud that enters the module interior, and the effects of the debris cloud within the module on module pressure and temperature levels. This is accomplished through the application of elementary shock physics and thermodynamic theory.

Schonberg, William P.↗

A wall interference assessment/correction system

A Wall Signature method, the Hackett method, has been selected to be adapted for the 12-ft Wind Tunnel wall interference assessment/correction (WIAC) system in the present phase. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interferences at the model location. The Wall Signature method will be formulated for application to the unique geometry of the 12-ft Tunnel. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method-Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. Each set of wind tunnel/test article numerical simulations provides data to validate the WIAC method. A numerical wind tunnel test simulation is initiated to validate the WIAC methods developed in the project. In the present reported period, the blockage correction has been developed and implemented for a rectangular tunnel as well as the 12-ft Pressure Tunnel. An improved wall interference assessment and correction method for three-dimensional wind tunnel testing is presented in the appendix.

Lo, Ching F.↗

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett has been selected to be adapted for the Ames 12-ft Wind Tunnel WIAC system in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method--Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included: (1) On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference, and (2) Support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated.

Lo, C. F.↗

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett has been selected to be adapted for the Ames 12-ft Wind Tunnel WIAC system in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating blockage wall interference. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method--Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected data with those of the free-air simulation.

Lo, Ching F.↗

Analytical and numerical investigation of structural response of compliant wall materials, part 2

Theoretical analysis of an electrostatically driven wall system for a compliant wall drag reduction program is reported. The electrostatic wall system is capable of producing deflections of many orders greater than the wall thicknesses and at small wavelengths. An intermediate large response theory is used for structural analysis. The theoretical predictions are compared to bench test results, and good agreement between the two is obtained. The effects of aerodynamic loads and perturbation electric fields on the theoretical solutions are considered. It is shown that for very small wavelengths (lambda almost equals 2 mm) the aerodynamic effects can be estimated using potential theory without loss of accuracy, and the perturbation electric fields do not effect solutions as long as the deflections are less than one percent of the wavelength. Resonance effects for this type of structure are shown to be fairly small.

Balasubramanian, R.↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Analytical and numerical investigation of structural response of compliant wall materials

Theoretical analysis of an electrostatically driven wall system for a compliant wall drag reduction program is reported. The electrostatic wall system is capable of producing deflections of many orders greater than the thicknesses and at small wavelengths. An intermediate large response theory was used for structural analysis. The theoretical predictions were compared to bench test results, and good agreement between the two was obtained. The effects of aerodynamic loads and perturbation electric fields on the theoretical solutions were considered. It was shown that for very small wavelengths (approximately 2mm) the aerodynamic effects can be estimated using potential theory without loss of accuracy, and the perturbation electric fields do not affect solutions as long as the deflections are less than one percent of the wavelength. Resonance effects for this type of structure were shown to be fairly small.

Goglia, G. L.↗

Investigation of blown boundary layers with an improved wall jet system

The behavior of two dimensional incompressible turbulent wall jets submerged in a boundary layer when they are used to prevent boundary layer separation on plane surfaces is investigated. The experimental set-up and instrumentation are described. Experimental results of zero pressure gradient flow and adverse pressure gradient flow are presented. Conclusions are given and discussed.

Saripalli, K. R.↗

Investigation of blown boundary layers with an improved wall jet system

Measurements were made in a two dimensional incompressible wall jet submerged under a thick upstream boundary layer with a zero pressure gradient and an adverse pressure gradient. The measurements included mean velocity and Reynolds stresses profiles, skin friction, and turbulence spectra. The measurements were confined to practical ratios (less than 2) of the jet velocity to the free stream velocity. The wall jet used in the experiments had an asymmetric velocity profile with a relatively higher concentration of momentum away from the wall. An asymmetric jet velocity profile has distinct advantages over a uniform jet velocity profile, especially in the control of separation. Predictions were made using Irwin's (1974) method for blown boundary layers. The predictions clearly show the difference in flow development between an asymmetric jet velocity profile and a uniform jet velocity profile.

Saripalli, K. R.↗

Asymptotic behavior of modulated Taylor-Couette flows with a crystalline inner cylinder

The linear stability of a modulated Taylor-Couette system when the inner cylindrical boundary consists of a crystalline solid-liquid interface is considered. Both experimentally and in numerical calculations it is found that the two-phase system is significantly less stable than the analogous rigid-walled system for materials with moderately large Prandtl numbers. A numerical treatment based on Floquet theory is described, which gives results that are in good agreement with preliminary experimental findings. In addition, this instability is further examined by carrying out a formal asymptotic expansion of the solution in the limit of large Prandtl number. In this limit the Floquet analysis is considerably simplified, and the linear stability of the modulated system can be determined to leading order through a conventional stability analysis, without recourse to Floquet theory. The resulting simplified problem is then studied for both the narrow gap geometry and for the case of a finite gap. It is surprising that the determination of the linear stability of the two-phase system is considerably simpler than that of the rigid-walled system, despite the complications introduced by the presence of the crystal-melt interface.

Braun, R. J.↗

Accelerating the Adoption of the Solid Panel Structural System

This report, "Accelerating the Adoption of the Solid Panel Structural System", explores the structural properties, capabilities, and applications for an innovative “studless” building system that uses a plate-like approach and “Perfect Wall” principles for an efficient, durable, and robust wall system. A comprehensive testing regime was completed to fully characterize the structural behavior of the Solid Panel Structural system. These results were used to develop an engineering guide that can be used by architects and engineers for design and code approval.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytical Modeling of Pressure Wall Hole Size and Maximum Tip-to-Tip Crack Length for Perforating Normal and Oblique Orbital Debris Impacts

This report presents the results of a study whose objective was to develop first-principles-based models of hole size and maximum tip-to-tip crack length for a spacecraft module pressure wall that has been perforated in an orbital debris particle impact. The hole size and crack length models are developed by sequentially characterizing the phenomena comprising the orbital debris impact event, including the initial impact, the creation and motion of a debris cloud within the dual-wall system, the impact of the debris cloud on the pressure wall, the deformation of the pressure wall due to debris cloud impact loading prior to crack formation, pressure wall crack initiation, propagation, and arrest, and finally pressure wall deformation following crack initiation and growth. The model development has been accomplished through the application of elementary shock physics and thermodynamic theory, as well as the principles of mass, momentum, and energy conservation. The predictions of the model developed herein are compared against the predictions of empirically-based equations for hole diameters and maximum tip-to-tip crack length for three International Space Station wall configurations. The ISS wall systems considered are the baseline U.S. Lab Cylinder, the enhanced U.S. Lab Cylinder, and the U.S. Lab Endcone. The empirical predictor equations were derived from experimentally obtained hole diameters and crack length data. The original model predictions did not compare favorably with the experimental data, especially for cases in which pressure wall petalling did not occur. Several modifications were made to the original model to bring its predictions closer in line with the experimental results. Following the adjustment of several empirical constants, the predictions of the modified analytical model were in much closer agreement with the experimental results.

Schonberg, William P.↗

Selecting durable building envelope systems with machine learning assisted hygrothermal simulations database

Hygrothermal simulations provide insight into the energy performance and moisture durability of building envelope components under dynamic conditions. The inputs required for hygrothermal simulations are extensive, and carrying out simulations and analyses requires expert knowledge. An expert system, the Building Science Advisor (BSA), has been developed to predict the performance and select the energy-efficient and durable building envelope systems for different climates. The BSA consists of decision rules based on expert opinions and thousands of parametric simulation results for selected wall systems. The number of potential wall systems results in millions, too many to simulate all of them. We present how machine learning can help predict durability data, such as mold growth, while minimizing the number of simulations needed to run. The simulation results are used for training and validation of machine learning tools for predicting wall durability. We tested Artificial Neural Network (ANN) and Gradient Boosted Decision Trees (GBDT) for their applicability and model accuracy. Models developed with both methods showed adequate prediction performance (root mean square error of 0.195 and 0.209, respectively). Finally, we introduce how the information supports guidance for envelope design via an easy-to-use web-based tool that does not require the end-user to run hygrothermal simulations.

Salonvaara, Mikael↗

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory and the University of Minnesota are conducting a three-year, multipart study on residential retrofit wall assemblies. The project is funded by the U.S. Department of Energy’s Building Technology Office and will identify, test and verify wall assemblies for hygrothermal performance in retrofit applications. The study includes a comprehensive literature review and expert advisory group, which inform wall selection. Selected wall assemblies are then thermally simulated using EnergyPlus and THERM, and hygrothermally simulated using WUFI, to model both thermal and moisture performance of the wall assembly. Eight wall assemblies are then experimentally tested in an in-situ laboratory environment at the University of Minnesota, with a typical residential wall used as a baseline. The in-situ experiment looks at the physical hygrothermal performance of each assembly. The simulation and experimental results will be combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits. This paper presents progress after year one of the study. Wall system modeling and laboratory testing is scheduled to begin in November, 2019. We will discuss the parameters for wall selection and experimental design, which includes approaches to modeling and simulation, along with the physical experiment design. This paper will also outline the parameters for the techno-economic analysis, and criteria used to inform model development.

Antonopoulos, Chrissi A.↗

Sensitivity of dual-wall structures under hypervelocity impact to multi-layer thermal insulation thickness and placement

Results are presented from an experimental study in which Al dual-wall structures were tested, under various high-speed impact conditions, with a view to the effect of multilayer insulation thickness and location on perforation resistance. Attention is given to comparisons of the damage sustained by dual-wall systems with multilayer insulation blankets of various thicknesses and at various locations within the dual-wall system, under comparable impact loading conditions. The placement of the insulation has a significant effect on the ballistic limit of the dual-wall structures considered, while reducing insulation thickness by as much as a third did not.

Schonberg, William P.↗