At least 37 records · Page 2

Implementation of a High-Fidelity Interface Resolving Method in Nek5000

The development and utilization of computational fluid dynamics (CFD) models for large, high-temperature electric melters in the Waste Treatment and Immobilization Plant (WTP) in eastern Washington State have proven to be valuable for various purposes. These models allow for a better understanding of the physio-chemical processes occurring within the melter vessels and can contribute to improving operational efficiency, throughput, and addressing operational issues related to vitrification. The CFD models employed for these melter vessels incorporate multiphase fluid flow and heat transfer simulations in different regions, including the plenum, cold cap, and molten glass regions. As the tank waste and glass formers are introduced into the melter, a reacting batch layer known as the cold cap forms on top of the molten glass. To enhance the melt rate, forced convection bubblers located at the bottom of the melters generate convection currents that help homogenize the molten glass and provide heat to the cold cap. As the bubbles rise through the highly viscous glass, they adopt a spherical-cap shape [1]. Meanwhile, the conversion of the batch to glass generates significant amounts of gases (such as water vapor, carbon dioxide, sulfur dioxide, and NOx) due to thermal decomposition [2]. These gases become trapped between the cold cap and molten glass, forming a foam layer [3]. For modeling multiphase flow in CFD and heat transfer simulations of waste glass melters at different scales, efforts are underway to augment the capabilities of the Nek5000 [4] and NekRS [5] open-source codes [6]. Nek5000/NekRS is a scalable and efficient spectral element code that has been successfully applied to a wide range of fluid dynamics problems. By leveraging the Nek5000/NekRS software, it becomes possible to model the melter systems more affordably and with lower computational requirements compared to currently utilized commercial CFD software. The specific objectives of this ongoing effort include: 1. Implementation of a level set method in Nek5000/NekRS: The level set method is a numerical technique commonly employed in CFD simulations to track and represent the interface between different phases or materials accurately. By incorporating this method into Nek5000/NekRS, the ability to simulate multiphase flows in waste glass melters at a high level of fidelity can be achieved. 2. Demonstration of capability for air bubbling through molten glass: As part of the development process, a specific case of air bubbling through molten glass will be simulated using the augmented Nek5000/NekRS code. This demonstration aims to showcase the ability of the software to accurately capture and analyze the complex phenomena involved in the multiphase flow within waste glass melters. By achieving these objectives, the improved Nek5000/NekRS code will offer a powerful computational tool for simulating and analyzing waste glass melter systems, enabling better understanding, optimization, and troubleshooting of these vitrification processes. The ability to accurately model and simulate multiphase flows has broad relevance across many industries and scientific domains, and the improved functionality can contribute to advancements in various fields beyond waste glass melter simulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification Testing of HLW with High Phosphate

Projections of the number of high level waste (HLW) canisters to be produced in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) (e.g., [1]) are based upon the inventory of the tank wastes, the anticipated performance of the sludge treatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier Department of Energy (DOE) melter designs, incorporates a glass bubbler system. The bubblers create active glass pool mixing and thereby improve heat and mass transfer and glass melting rate. The WTP HLW melters each have a glass surface area of 3.75 m 2 and depth of ~1.1 m. The two melters in the HLW facility together are designed to produce up to 7.5 MT of glass per day at 100% availability. Further increases in HLW waste processing rates can potentially be achieved by optimization of the feed and glass formulations, increasing the melter operating temperature above 1150⁰C, and by increasing the waste loading in the glass product. Increasing the waste loading also has the added benefit of decreasing the number of canisters for storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conversion degree and heat transfer in the cold cap and their effect on glass production rate in an electric melter

A predictive model of melt rate in waste glass vitrification operations is needed to inform melter operations during normal and off-normal operations. This paper describes the development of a model of the cold cap (the reacting melter feed floating on molten glass in a glass melter) that couples heat transfer with the feed-to-glass conversion kinetics. The model was applied to four melter feeds designed for high-level and low-activity nuclear waste feeds using the material properties, either measured or estimated, to obtain temperature and conversion distribution within the cold cap. The cold cap model, when coupled with a computational fluid dynamics model of a Joule-heated glass melter, allows the prediction of the glass production rate and power consumption. The results show reasonable agreement with the melting rates measured during pilot-scale melter tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Viscosity of glass-forming melt at the bottom of high-level waste melter feed cold caps: Effects of temperature and incorporation of solid components

At the final stages of conversion of melter feed (glass batch) to molten glass, the transient glass-forming melt becomes a continuous liquid phase encapsulating dissolving solid particles and gas bubbles that produce primary foam at the bottom of the cold cap (the reacting melter feed in an electric glass melting furnace). The glass-forming melt viscosity plays a dominant role in primary foam formation, stability, and eventual collapse, thus affecting the rate of melting (the glass production rate per cold cap area). For several melter feeds designed for nuclear waste vitrification, we have traced the glass-forming melt viscosity during the final stages of feed-to-glass conversion as it changes in response to changing temperature and composition (resulting from dissolving solid particles). Starting with a relatively low values at the moment when the melt connects, melt viscosity reaches maximum within the primary foam layer and then decreases to its final melter-operating temperature value. We paid a particular attention to the cold-cap bottom—the boundary between the primary foam layer and the thermal boundary layer—where the melt viscosity affects the rate of melting predominantly through its effect on the temperature at which primary foam is collapsing.

Lee, Seung Min↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Microstructural examination of interactions between chromia-based refractory and nuclear glass in a melter

This study shows the effects of nuclear waste glass production on Monofrax K-3 refractory corrosion. A continuously fed research-scale melter containing an Fe- and Ni-rich simulated nuclear waste feed with borosilicate glass-forming chemicals was cyclically melted at 1150°C and idled at 1050°C for a total of 11 weeks. Chemical maps using scanning electron microscopy show the interactions between the quenched melt and the refractory. Nanoscale X-ray-computed tomography was used for a three-dimensional visualization of certain parts of the interface. Unreacted K-3 consists of primarily corundum (Al,Cr) 2 O 3 and spinel (Fe 2+ ,Mg)(Al,Cr) 2 O 4 interlocking crystalline phases. Some of the Cr from the refractory interacts with the Ni and Fe from the melt to form a reaction layer comprising (Ni,Fe 2+ )(Cr,Fe 3+ ) 2 O 4 spinel crystals. Simultaneously, melt components (Na,Si) infiltrate into the refractory. This interaction proceeds at the expense of the integrity of the refractory structure. Intact refractory grains (e.g., (Al,Cr) 2 O 3 ) as well as the reaction layer itself can lose mechanical integrity and spall off into the melt, especially near the top of the melter. As the reaction layer can be a protective boundary for the refractory against further melt infiltration, a reduction in the reaction layer thickness allows an increase in refractory corrosion.

36 MATERIALS SCIENCE↗

Glass formulation and lab-scale testing of glasses designed for in-can Melter and in-container Vitrification of high-assay low-enriched uranium aqueous polishing Raffinate waste

Glasses were designed for processing a nuclear waste from aqueous polishing of high-assay low-enriched uranium using either In-Can Melter (ICM) or GeoMelt® In-Container Vitrification™ (ICV) technologies, which operate at temperatures of T p ≤ 1100 °C and T p ≤ 1450 °C, respectively. Due to the different operating conditions, the melt and glass properties were optimized differently for each technology. Each glass was designed to optimize for maximum waste loading while simultaneously satisfying processing (e.g., crystallization, viscosity, and conductivity) and product quality (e.g., durability, hazard characteristic, and crystal content) constraints. Here, the raffinate waste contains high nitric acid (4 M) and low total solids (9 g·L -1 ) concentrations. Feed preparation processes were tested to facilitate concentration and nitrate destruction/removal while controlling redox of the melter feed. A successful feed process including sugar addition and spray-drying was performed to generate an adequate melter feed for ICV processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-101 Waste and Simulant

Hanford tank 241-AP-101 (referred to herein as AP-101) is the second Hanford radioactive tank waste planned to be processed and vitrified. A simulant version of AP 101 waste was formulated from the best-basis inventory (BBI) for the Hanford Tank 241-AP-101 liquid with an assumed target dilution of the waste from the BBI sodium molarity of 8.61 M to the desired 5.5 M Na. After the addition of glass-forming chemicals (GFCs), the simulant melter feed was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system. The AP-101 simulant melter feed was charged into the CLSM for 6.11 h of processing, which produced 6.55 kg of glass, for an average glass production rate of 2275 kg m 2 d -1 . Since there were no processing issues with the AP-101 simulant melter feed, AP-101 melter feed made with actual waste was then processed in a CLSM system built into a contamination area in a radioactive environment. The melting behavior characteristics appeared similar for both the simulant and waste melter feeds. The AP-101 waste melter feed was charged into the CLSM for 12.14 h of processing, which produced 8.75 kg of glass, for an average glass production rate of 1530 kg m 2 d -1 . During the AP-101 waste melter feed charging, the pump used to move the feed reached a maximum and it is believed that if the pump had a greater capacity, a greater average glass production rate could have been achieved. A constituent of interest present in low quantities in the AP-101 waste is 99 Tc or its non-radioactive surrogate, Re, added to the AP-101 simulant. Analysis for the quantities of 99 Tc and Re in the AP-101 glass product resulted in an average single-pass retention from the melter feed during relative chemical steady state of 55 ± 2 % for 99 Tc and 45 ± 2 % for Re. Compared to the processing of other melter feeds, the retention of 99 Tc in the AP-101 glass was greater than in both AP-107 and AP-105 glass, while the retention of Re in the AP-101 was less than in the AP-107 glass, but greater than in the AP-105 glass. A spike of I was added into the AP-101 melter feed that could be detected above the analysis detection limits. However, the iodine was only detectable above the ~6 ppm limit in one glass pour: the pour immediately following the burn off of the cold cap, where the I level reached ~30 ppm. This event was significant because the glass was poured immediately after burn off and thus it is presumed that the iodine had yet to volatilize from the glass melt while idling. It is recommended to perform future tests with I spikes at greater levels so that it can be detected in additional glass pours to determine if the expected 50 % retention of I used in the Kim et al. glass models can be confirmed. Offgas liquid samples were analyzed for acetonitrile, which was present at greater concentrations in CLSM liquids than in other scaled melter systems. This result was expected based on unique conditions with the CLSM system including a small plenum space leading to low residence time for offgas and the rapidity of offgas cooling upon exiting the CLSM vessel due to the location and environment. About 90 % of the total acetonitrile captured during both the AP-101 simulant and waste CLSM runs was found in the offgas condensate and demister liquids, thus it is recommended that only those liquids be sent for analysis if future testing to study the presence of acetonitrile in offgas products is desired.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Crystallization Constraints for WTP LAW Operations: Assessment of Isothermal Treatments on Crystal Formation

Much work has been done to expand the glass composition region available for operation of the Hanford Waste Treatment and Immobilization Plant. This includes the development of updated glass property-composition models as well as constraints. This report supports this effort by suggesting constraints for avoiding excessive, and likely detrimental, crystallization during melter operation while processing advanced low-activity glass waste forms. The constraints target SnO 2 and ZrO 2 crystals that can form when melter temperatures drop below 1100 °C. These types of crystals were found to be potentially detrimental during processing as they are denser than low-activity waste glass melts. SnO 2 , density of 6.95 g/cm3, and ZrO 2 , density of 5.68 g/cm3, have the potential to form during melter idling and settle to the bottom of the less dense glass melt (approximate density 2.65 g/cm3). If the crystals are present in appreciable amounts, they can result in blockages of the pour-spout riser, which impacts glass pouring and melter operation. Using previously acquired results and results from testing during this effort, constraints were determined and are suggested as options to reduce the risk of forming crystals of the types and concentrations that are likely detrimental to melter operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of non‐framework cation mixing on the structure and crystallization behavior of model high‐level waste glasses

Abstract Spinel crystallization is known to be detrimental to the operation of Joule heated ceramic melters during the vitrification of iron‐rich high‐level nuclear wastes (HLW) into borosilicate glasses. The literature on this subject focuses on tackling the problem by developing empirical constraints to design compositions, which limit the fraction of spinels formed in the melter or by developing empirical models to predict the settling behavior of spinels in the melter as a function of the glass composition. While these empirical models can predict the behavior of most of the compositions, they are not failsafe as there are always some compositions, whose behavior is beyond the predictive ability of these models. This can lead to undesirable situations during the vitrification of the nuclear waste, and therefore an in‐depth investigation of the chemo‐structural descriptors controlling the crystallization behavior in these glasses is warranted. Accordingly, the present study aims to understand the impact of non‐framework cation mixing (i.e., Li + /Na + and Ca 2+ /Na + ) on the structure (through Raman spectroscopy and Mössbauer spectroscopy) and crystallization behavior (through XRD, SEM‐EDS, and vibrating sample magnetometry) of iron‐rich model HLW glasses in the system: (mol.%) x M y O–(25− x ) Na 2 O–9.12 B 2 O 3 –6.4 Al 2 O 3 –51.25 SiO 2 –7.22 Fe 2 O 3 –0.38 MnO–0.08 Cr 2 O 3 –0.55NiO (M y O = Li 2 O or CaO).

Balasubramanya, Nikhila↗

Physical and Flow Properties of Glass Forming Chemicals (V2O5, SnO, SnO2, Cr2O3, FeCr2O4, and ZrSiO4) and Mixtures

For a sustainable nuclear waste vitrification process at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), proper selection and consistent supply of glass-forming chemicals (GFCs) are crucial. Establishing rigorous acceptance criteria for the characterization of GFCs will be required to operate the vitrification facility and to mitigate any processing issues or failures. Low-activity wastes (LAW) are blended with GFCs to form slurry melter feeds and vitrified in a melter. To enhance properties of waste glasses, new chemicals are being introduced to the current GFC mixture (Vienna et al. 2016; Muller et al. 2017, 2019). In this study, three new GFCs were evaluated for enhanced LAW glass formulations: chromium oxide (Cr 2 O 3 ), vanadium oxide (V 2 O 5 ), and stannic oxide (SnO 2 ). These three oxide components are included in enhanced waste glass (EWG) formulations and GFCs with the appropriate physical and flow properties are needed. As a starting point, single metal oxide GFCs: Cr 2 O 3 , V 2 O 5 , and SnO 2 were sourced and tested. To characterize these new individual GFCs and mixtures of GFCs, the industrial bulk characterization consultant, Jenike and Johanson, was employed to measure physical and flow properties of individual GFCs and their mixtures. Pacific Northwest National Laboratory (PNNL) also measured several selected physical properties for data evaluation as a quality assurance step. In addition, PNNL measured physical and rheological properties of slurry melter feeds containing those GFCs. Subsequent data analyses and verification were conducted. The purpose of this report is to assess the applicability of these GFCs for LAW vitrification based on their properties. This report will help understand measured data and evaluate new GFCs for use. Moreover, this report may give useful insights to help troubleshoot any GFC and melter feed transport and mixing issues that arise during processing, leading to a successful cleanup mission at WTP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computational Fluid Dynamics Simulations of Glass Vitrification Refractory Coupon Tests

The Waste Treatment and Immobilization Plant (WTP) at the Hanford site is nearing the start of the Direct-Feed Low-Activity Waste (DFLAW) operations. DFLAW is destined to convert a pretreated low activity waste portion of the 56 million gallons of tank waste into a stable solid glass. In the subsequent decade completion of the high-level waste (HLW) facility is anticipated. Sustained operational missions of both LAW and HLW melter facilities are expected over multiple decades. In high-temperature glass melters, the refractory lining corrodes over time, which could potentially be an issue for longer term operations, this refractory corrosion is higher at the level of the glass-air interface due to surface tension driven flow. The glass viscosity, melt pool temperature, and glass chemical composition can impact the rate at which the refractory corrodes. This rate is important to quantify for the various waste glasses to be produced at the WTP since the integrity of the refractory should not be a limiting factor affecting the lifetime of the melter. To this end, a series of glasses representative of the first batches of waste glass produced by the WTP will be melted in small-scale crucibles with Monofrax® K-3 coupons inserted. The corrosion of the K-3 will be measured in the melt and at the meltline (or neckline). A model for the corrosion rate will be constructed and implemented into a previously developed framework for a computational fluid dynamics (CFD) model of the full-scale WTP. To assist with experimental design and validate the implementation of the model in the full-scale melter, CFD simulations of the small-scale crucible tests were performed. The bubbling that occurs in the small-scale crucible is initially validated here with a model that uses silicone oil at room temperature. The viscosity of the oil ranges from 1 to 100 Pa•s, which corresponds to operating glass pool temperatures near 1150 °C down to idling temperatures near 950 °C. The simulation results show good agreement with the bubble sizes that form during experiments. CFD modeling of the crucible setup was used to determine bubbling characteristics to match the range of near-wall velocities expected in the full-scale WTP. This study presents the initial CFD modeling results, corrosion testing plan, and some preliminary corrosion samples with an outline for the next steps for the development of the corrosion model.

Abboud, Alexander W. [Idaho National Lab]↗

Reduced-Order CFD Modeling to Support Waste Loading Optimization in Hanford WTP Vitrification

The U.S. DOE Hanford Site stores over 56 million gallons of radioactive liquid tank waste that must be treated and immobilized for long-term disposal The Waste Treatment and Immobilization Plant (WTP) will vitrify this waste by feeding it into Joule-heated melters, where it is incorporated into a stable borosilicate glass Computational fluid dynamics (CFD) simulations of glass melters can provide insight into the maximum achievable waste loading under varying melter operating conditions Fully resolved VOF multiphase simulations were used as the reference model to capture bubble-driven convection in the melter, including bubble formation, rise behavior, and induced glass melt circulation Effective bubble column diameter and rise velocity were extracted from the resolved simulations, compared with empirical correlations, and refit across relevant viscosity and gas flow rate conditions Explicit gas–liquid interface tracking was replaced with a single-phase momentum source term model, enabling faster steady-state CFD simulations while preserving the dominant hydrodynamic effects of bubbling New empirical correlations were developed for effective bubble column diameter and bubble rise velocity by fitting resolved simulation data across expected melter viscosity and gas flow rate ranges, providing improved inputs for the momentum source term model compared with existing literature correlations The momentum source term model reduced fluid-domain mesh size by 89% and achieved an 8.4× computational speedup relative to resolved bubbling simulations The validated momentum source term approach enables prediction of process-relevant heat transfer behavior in the integrated melter model, including heat transfer from the molten glass to the cold cap, plenum, refractory walls, and surrounding structural regions under varying melter operating conditions

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Optimization Efforts at DWPF to Ensure Waste Tank Closure by 2037 – 24404

At the Savannah River Site (SRS) in Aiken, South Carolina, the Defense Waste Processing Facility (DWPF) produces a glass-form product by processing high-level liquid waste (HLW) with borosilicate glass in a high-heated Melter, then putting the vitrified waste into stainless-steel canisters. Since 1996, DWPF has performed this vitrification process for the liquid waste mission at the SRS; the overall objective for this mission is to reduce the volume in the upstream waste tanks, so those tanks can be emptied and operationally closed. This mission seeks to eliminate the single biggest environmental risk in the state of South Carolina, which requires a robust processing strategy within the DWPF, along with optimal interface between the other facilities in the liquid waste organization (LWO). As of the end of July 2023, DWPF has safely remediated 63.7 MCi of HLW, and filled 4,319 canisters (We project that about 4,000 more canisters are needed to be filled to reach the closure goal.)

Armstead, III, Frank L.↗

Defense Waste Processing Facility Nitric-Glycolic Flowsheet Chemical Process Cell Chemistry: Part 2

The conversions of nitrite to nitrate, the destruction of glycolate, and the conversion of glycolate to formate and oxalate were modeled for the Nitric-Glycolic flowsheet using data from Chemical Process Cell (CPC) simulant runs conducted by Savannah River National Laboratory (SRNL) from 2011 to 2016. The goal of this work was to develop empirical correlation models to predict these values from measurable variables from the chemical process so that these quantities could be predicted a-priori from the sludge or simulant composition and measurable processing variables. The need for these predictions arises from the need to predict the REDuction/OXidation (REDOX) state of the glass from the Defense Waste Processing Facility (DWPF) melter. This report summarizes the work on these correlations based on the aforementioned data. Previous work on these correlations was documented in a technical report covering data from 2011-2015. This current report supersedes this previous report. Further refinement of the models as additional data are collected is recommended. The glass REDOX depends on the concentrations of nitrate and manganese (oxidants), and of glycolate, formate, oxalate, carbon, and antifoam (reductants) in the melter feed. The waste sludge contains nitrite, nitrate, manganese (Mn), and oxalate. Virtually all of the nitrite is converted to nitrate or NO+NO 2 +N 2 O gases in the CPC. The portion of the nitrite converted to nitrate increases the amount of nitrate in the sludge. The amount of glycolate in the final melter feed depends on the amount of the glycolic acid feed that is destroyed. Similarly, the amounts of formate and oxalate formed during the decomposition of glycolic acid are required. The material balance on carbon was found to not close in most cases. Generally, there was less carbon at the end of testing compared to the inputs. The most uncertain product variable was glycolate, so material balances were performed where the glycolate concentration was adjusted, usually upward, to close the balance. Correlation versus the original, as-measured, data was generally poor, but correlation against the material balance adjusted values was greatly improved. It was also shown that the correlation of the measured REDOX versus the predicted REDOX was much better when the material balance adjusted glycolate values were used. Three data series were primarily used during the regressions of the data; these series were 1) Sludge Batch 9 NG flowsheet simulant runs NG51-62 (SB9-NG); 2) Scaled Runs + Bounding Hydrogen Runs (SR+BH); and 3) Runs GN43-50 and 57 (43-50,57). The glycolate destruction was found to correlate with acid stoichiometry (AS), percent reducing acid (PRA), and for some data series, headspace to simulant volume ratio (HSV), mercury (Hg), and nitrate. Although glycolate destruction for pairs of data series (e.g., [SB9-NG] and [SR+BH]) were found to depend on HSV, the combination of all three data series was not found to have significant dependence on this variable. The best model for glycolate destruction depended on AS, nitrate, and Hg. This model predicted the product glycolate compositions of the data to within 92-106%. The conversion of glycolate to formate was high when noble metals and Hg were not present, with values up to 100%. When noble metals and Hg were present, this conversion ranged from zero to 7%, and was dependent on AS. Lower AS gave higher conversions to formate. The conversion to oxalate was found to depend on the AS and the initial concentration of nitrite. An alternative fit versus AS and the form of ruthenium (Ru) used is a possible alternative. This fit was somewhat less statistically significant. This second model predicts that more oxalate is formed when Ru-nitrosyl nitrate is used rather than Ru chloride. The conversion of glycolate to oxalate ranged from zero to 6%. The conversion of nitrite to nitrate depended primarily on AS and PRA, with HSV and Hg being significant when these variables were varied. For multiple series of data, nitrite was also needed to SRNL-STI-2017-00172 5HYLVLRQ viL distinguish between data series, and the effect of HSV became insignificant. The best model for nitrite to nitrate conversion depended on AS, PRA, nitrite, and Hg. The 95% confidence intervals on the predicted values of glycolate destruction, glycolate to oxalate conversion, and nitrite to nitrate conversion were used to determine the uncertainty in the predicted REDOX when starting with only the composition of the sludge, AS, and PRA. Using the 95% confidences on an individual value (that is the confidence in getting a particular value for one single test as opposed to what the mean would be for multiple tests), the uncertainty in the predicted REDOX was calculated. The uncertainty in the actual product composition glycolate, oxalate, formate, and nitrate concentrations translated to an uncertainty in the REDOX value of ±0.1,which is approximately the uncertainty claimed in the REDOX model itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phosphate and Fluoride Processing Options for Hanford Sludge

The Direct Feed High-Level Waste (DFHLW) strategy represents an alternative flowsheet to bypass the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration and should be considered in the new DFHLW flowsheet to maximize waste feed loading, minimize high-level waste (HLW) volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. The effectiveness and efficiency of sludge washing can have a substantial impact on DST space and mission duration. Two target species that benefit significantly from washing are phosphate and fluoride. Commonly present in many high-level wastes at Hanford, phosphate and fluoride are found predominately in the form of salt precipitates and can have adverse and detrimental effects on glass waste loading. Additionally, fluoride produces melter off-gas that creates corrosion risks in the off-gas system piping. Determining the solubilities of fluoride and phosphate salts, as well as the dissolution kinetics under potential HLW processing conditions will help to mitigate future operational risks and mature flowsheet technical bases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and Flow Properties of Glass-Forming Chemicals (V 2 O 5 , SnO, SnO 2 , Cr 2 O 3 , FeCr 2 O 4 , and ZrSiO 4 ) and Mixtures

For an efficient nuclear waste vitrification process at the Waste Treatment and Immobilization Plant (WTP) on the Hanford Site, proper selection and consistent supply of glass-forming chemicals (GFCs) are crucial. Thorough characterization of the GFCs is required to reduce risks in operation of the vitrification facility. Low-activity waste (LAW) will be blended with GFCs to form slurry feeds and then fed to melters and vitrified. To enhance properties of waste glasses, new chemicals are being introduced to the current GFC mixture. In this study, three new GFCs were evaluated for enhanced LAW glass formulations: chromium oxide (Cr 2 O 3 ), vanadium oxide (V 2 O 5 ), and stannic oxide (SnO 2 ). These three oxide components are included in enhanced waste glass formulations, and GFCs with the appropriate physical and flow properties are needed. As a starting point, single metal oxide GFCs, Cr 2 O 3 , V 2 O 5 , and SnO 2 , were sourced and tested. Then, alternative sources of Sn and Cr (SnO and FeCr 2 O 4 ) were tested along with an alternative zircon source (ZrSiO 4 ). This report documents the work performed to collect physical and flow property data on these new GFCs and melter feed slurries generated using these GFCs and simulated low-activity wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗