Search NASA⌕ Search

SEARCH · Search NASA

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UCNB_Analyzer

The purpose of this software is to interpret and analyze data taken using the NI PXIe-5171R digitizer based data acquisition system for the UCNB and Nab experiments. The detection and data acquisition systems are identical for the 2 experiments, with some differences in analysis requirements. The software converts raw binary files produced by the NI DAQ into ROOT TTree format, performs waveform analysis using trapezoidal filter algorithms, pulse fitting, and noise analysis routines, and applies variable criteria to identify valid events in the data stream. The software will be used to perform analysis of the events for multi-channel coincidences, timing and energy studies, and event rates under different experimental conditions.

Broussard, LeahJ↗

UCNB_Analyzer

The purpose of this software is to interpret and analyze data taken using the NI PXIe-5171R digitizer based data acquisition system for the UCNB and Nab experiments. The detection and data acquisition systems are identical for the 2 experiments, with some differences in analysis requirements. The software converts raw binary files produced by the NI DAQ into ROOT TTree format, performs waveform analysis using trapezoidal filter algorithms, pulse fitting, and noise analysis routines, and applies variable criteria to identify valid events in the data stream. The software will be used to perform analysis of the events for multi-channel coincidences, timing and energy studies, and event rates under different experimental conditions.

Broussard, Leah J↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Solving seismological problems using sgraph program: II-waveform modeling

One of the seismological programs to manipulate seismic data is SGRAPH program. It consists of integrated tools to perform advanced seismological techniques. SGRAPH is considered a new system for maintaining and analyze seismic waveform data in a stand-alone Windows-based application that manipulate a wide range of data formats. SGRAPH was described in detail in the first part of this paper. In this part, I discuss the advanced techniques including in the program and its applications in seismology. Because of the numerous tools included in the program, only SGRAPH is sufficient to perform the basic waveform analysis and to solve advanced seismological problems. In the first part of this paper, the application of the source parameters estimation and hypocentral location was given. Here, I discuss SGRAPH waveform modeling tools. This paper exhibits examples of how to apply the SGRAPH tools to perform waveform modeling for estimating the focal mechanism and crustal structure of local earthquakes.

58 GEOSCIENCES↗

Experimental Study of the Rare Neutral-Kaon Decays at J-PARC (Final Technical Report)

Understanding the origin of CP violation is currently one of the most forefront issues in elementary particle physics. Together with a better understanding of quark mixing and neutrino mixing phenomena, it is one of the central goals of particle physics, and has been pursued vigorously in many experiments. The very rare decay $K_L \to \pi ^0 v\bar{v}$ provides one of the best probes for understanding the original of CP violation in the quark sector. Particularly, theoretical uncertainties are very small in the Standard Model (SM) calculations, and the value therefore most suitable to be tested for beyond SM contributions. J-PARC E14 (also known as KOTO) aims to reach Standard Model sensitivity and beyond with Stage-1 and Stage-2. KOTO acquired 100 hours beam data in May 2013 and the result has been accepted for publication. From 2015-16, KOTO increased the data set by a factor of twenty, which will allow a limit to be set at the Grossman-Nir bound. This bound is valid in virtually any extension of the Standard Model. By comparing this model-independent bound and SM prediction, it is clear that there is considerable room for new physics. Analysis on these collected data sets shows neutron interactions which mimic the two-photon signal could become a potential background. To discriminate neutron background from the photon signal, one important tool, as shown in current data, is to perform detailed waveform analysis of the signal from the phototubes. To fully capture the calorimeter pulse shape with best fidelity from 100 out of the 2700 channels of CsI, we built the 500 MSPS (Mega Samples Per Second) with 14-bit digitizers. With KOTO Stage-2 currently in the planning stages, we started R&D work on a full width, but length scalable photon veto barrel detector with detailed layout of active detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat↗

Creation of a Robust and Generalizable Machine Learning Classifier for Patient Ventilator Asynchrony

Background: As healthcare increasingly digitizes, streaming waveform data is being made available from an variety of sources, but there still remains a paucity of performant clinical decision support systems. For example, in the intensive care unit (ICU) existing automated alarm systems typically rely on simple thresholding that result in frequent false positives. Recurrent false positive alerts create distrust of alarm mechanisms that can be directly detrimental to patient health. To improve patient care in the ICU, we need alert systems that are both pervasive, and accurate so as to be informative and trusted by providers. Objective: We aimed to develop a machine learning-based classifier to detect abnormal waveform events using the use case of mechanical ventilation waveform analysis, and the detection of harmful forms of ventilation delivery to patients. We specifically focused on detecting injurious subtypes of patient-ventilator asynchrony (PVA).Methods: Using a dataset of breaths recorded from 35 different patients, we used machine learning to create computational models to automatically detect, and classify two types of injurious PVA, double trigger asynchrony (DTA), breath stacking asynchrony (BSA). We examined the use of synthetic minority over-sampling technique (SMOTE) to overcome class imbalance problems, varied methods for feature selection, and use of ensemble methods to optimize the performance of our model. Results: We created an ensemble classifier that is able to accurately detect DTA at a sensitivity/specificity of 0.960/0.975, BSA at sensitivity/specificity of 0.944/0.987, and non-PVA events at sensitivity/specificity of .967/.980. Conclusions: Our results suggest that it is possible to create a high-performing machine learning-based model for detecting PVA in mechanical ventilator waveform data in spite of both intra-patient, and inter-patient variability in waveform patterns, and the presence of clinical artifacts like cough and suction procedures. Our work highlights the importance of addressing class imbalance in clinical data sets, and the combined use of statistical methods and expert knowledge in feature selection.

97 MATHEMATICS AND COMPUTING↗

Tectonic tremor characterized by principal-component analysis in the vicinity of central Chile and Argentina

No conclusive evidence has been presented to date for tectonic tremor (TT) in the vicinity of central Chile, where the Nazca Plate is subducting beneath the South American Plate. Subduction in our experimental location (roughly 35.5° S, 70.5° W) is steep and fairly unobstructed compared to the flattened and more seismogenic behavior to the north. We seek to identify TT in our experimental area, whose geodynamics are comparable to tremor-rich subduction zones such as Cascadia and the Nankai Trough. Our method combines time-series visual inspection, frequency-spectrum analysis, waveform cross-correlation, and 3-component (3C) signal covariance to explore the presence of TT in this region. We have identified TT using stations in central Chile and the Malargüe region, Argentina. The TT exhibits similar features to other TT observations worldwide. Waveform characteristics for the TT in our study, particularly dimension of the 3C signal covariance, vary as a function of apparent source location. The duration of one episode of identified TT was about 10 h, which may indicate that the plate interface where tremor generates is strongly coupled. Here, we conclude that our observations reflect features of the local propagation, rather than the tremor source itself.

58 GEOSCIENCES↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Temperature-programmed elimination of tritium in coal labeled by tritiated gaseous hydrogen

The hydrogen exchange of an Argonne Pocahontas No. 3 (POC) coal with tritiated gaseous hydrogen in the presence of a Pt/Al{sub 2}O{sub 3} catalyst was carried out using a fixed-bed reactor at a temperature range of 200-250{sup o}C. Then, the tritiated coal sample was re-exchanged with hydrogen in a gaseous hydrogen atmosphere at different raising temperature rates. The changes in radioactivity of tritium releasing from the tritium-labeled coal sample in the temperature-programmed elimination (TPE) of tritium was monitored by a radioanalyzer in situ. The release profile of tritium was fit using three Gaussian distribution functions in TPE. On the basis of the waveform analysis, the amounts and activation energies of the hydrogen exchange for every type of exchangeable hydrogen were estimated. The values of exchange activation energies are 8.8 {+-} 0.5, 10.7 {+-} 0.5, and 16.3 {+-} 0.5 kcal/mol for three types of exchangeable hydrogen, respectively. The amount of type-I hydrogen was independent of the exchange reaction temperature. In contrast to this, the amount of types II and III of exchangeable hydrogen increased with an increasing exchange temperature, suggesting that the amount of types II and III of hydrogen in the coal is dependent upon the exchange temperature. 35 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Petahertz electronics

Petahertz, or lightwave, electronics uses tailored optical waveforms to control charge carriers in an electronic circuit at petahertz frequencies. This may enable faster processing than conventional pulsed electronics, which cannot be scaled beyond gigahertz frequencies. In recent years, petahertz-scale currents driven by optical fields have been measured in solid-state systems and nanoscale structures, with several proof-of-principle demonstrations of sub-optical-cycle current generation and optical-field-resolved waveform detection at the sub-femtosecond to few-femtosecond scale. Recent work has taken the first steps towards digital and quantum operation by exploring optical-field-driven logic and memory functionality. Here, in this Review, we discuss the progress towards sub-cycle field-driven current injection, highlighting key theoretical concepts, experimental milestones, and questions remaining as we push towards realizing petahertz electronics for ultrafast optical waveform analysis, digital logic, communications, and quantum computation.

Heide, Christian↗

Solving seismological problems using SGRAPH program: I-source parameters and hypocentral location

SGRAPH program is considered one of the seismological programs that maintain seismic data. SGRAPH is considered unique for being able to read a wide range of data formats and manipulate complementary tools in different seismological subjects in a stand-alone Windows-based application. SGRAPH efficiently performs the basic waveform analysis and solves advanced seismological problems. The graphical user interface (GUI) utilities and the Windows facilities such as, dialog boxes, menus, and toolbars simplified the user interaction with data. SGRAPH supported the common data formats like, SAC, SEED, GSE, ASCII, and Nanometrics Y-format, and others. It provides the facilities to solve many seismological problems with the built-in inversion and modeling tools. In this paper, I discuss some of the inversion tools built-in SGRAPH related to source parameters and hypocentral location estimation. Firstly, a description of the SGRAPH program is given discussing some of its features. Secondly, the inversion tools are applied to some selected events of the Dahshour earthquakes as an example of estimating the spectral and source parameters of local earthquakes. In addition, the hypocentral location of these events are estimated using the Hypoinverse 2000 program operated by SGRAPH.

58 GEOSCIENCES↗

Improved x-ray detection and particle identification with avalanche photodiodes

Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work, we report on a fitting technique used to account for different detector responses resulting from photoabsorption in the various avalanche photodiode layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2 and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g., to distinguish between x-rays and MeV electrons in our experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient creep‐fatigue crack growth in creep‐brittle materials: Application to Alloy 718

Abstract This study presents incremental finite element computations of creep‐fatigue crack growth in Alloy 718 at in air. Alloy 718 is representative of creep‐brittle materials, in which viscoplastic deformation is restricted near the tip of a growing crack. The computations predict crack growth using a unique combination of an irreversible cohesive zone formulation and a strain gradient viscoplastic material model based on the Kocks–Mecking formulation. Cohesive zone damage parameters are estimated using sustained loading and constant‐amplitude cyclic loading experiments. Computations of crack extension under three different waveforms containing overloads all predict post‐overload retardation. The amount of retardation depends strongly on the overload ratio, consistent with experiments in the literature using similar waveforms. Analysis of the crack‐tip fields demonstrates retardation is associated with unloading in the highly deformed material near the advancing crack tip. Dynamic recovery and geometrically necessary dislocations are shown to significantly influence post‐overload crack extension.

36 MATERIALS SCIENCE↗

Automatic Waveform Quality Control for Surface Waves Using Machine Learning

Surface-wave seismograms are widely used by researchers to study Earth’s interior and earthquakes. To extract information reliably and robustly from a suite of surface waveforms, the signals require quality control screening to reduce artifacts from signal complexity and noise. This process has usually been completed by human experts labeling each waveform visually, which is time consuming and tedious for large data sets. We explore automated approaches to improve the efficiency of waveform quality control processing by investigating logistic regression, support vector machines, K-nearest neighbors, random forests (RF), and artificial neural networks (ANN) algorithms. To speed up signal quality assessment, we trained these five machine learning (ML) methods using nearly 400,000 human-labeled waveforms. The ANN and RF models outperformed other algorithms and achieved a test accuracy of 92%. We evaluated these two best-performing models using seismic events from geographic regions not used for training. The results show that the two trained models agree with labels from human analysts but required only 0.4% of the time. Although the original (human) quality assignments assessed general waveform signal-to-noise, the ANN or RF labels can help facilitate detailed waveform analysis. Our investigations demonstrate the capability of the automated processing using these two ML models to reduce outliers in surface-wave-related measurements without human quality control screening.

58 GEOSCIENCES↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗